• Title/Summary/Keyword: eye field

Search Result 350, Processing Time 0.031 seconds

During the COVID-19 pandemic, Relationship between smart device usage time, eye health status, and eye health awareness among health college students (COVID-19 판데믹 시기에 보건계열대학생의 스마트기기 사용시간, 눈건강 실태, 눈건강 의식 간의 관계)

  • Yoon, Hyeon Gyeong;Kim, So Yeong;Park, Min Ji;Park, Ji Eun;Jeon, Hye Jin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.187-195
    • /
    • 2022
  • This study was conducted to confirm the relationship between smart device usage time, eye health status, and eye management consciousness during the COVID-19 Pandemic period for college students in the health field. The study participants were 188 health-related university students, and data analysis was performed using descriptive statistics, independent t-test, Chi-square test, one-way ANOVA, and Pearson's correlation coefficients using the SPSS 26.0 program. As a result of the study, the average of the subjects' eye fatigue score was 15.23±13.71, the dry eye subjective symptom score was 21.87±12.02, and the eye health management consciousness score was 3.48±1.09. Eye care awareness, dry eye symptoms (r=.152, p=.005) and eye fatigue, dry eye symptoms (r=.650, p<.001) were statistically significant positive correlation in the group using smartphones for 2 hours or more per day on average. Based on the results of this study, it is necessary to find a way to prevent eye health due to the use of smart devices by college students, and repeated studies are needed to confirm the factors affecting eye health.

A clinical analysis on glaucoma, cataract and causing-blindness-diseases by oriental medical therapy (內障과 眼盲疾患의 韓方治驗에 關한 小考)

  • Kim, Gyung-Jun;Chae, Bhung-Yoon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.10 no.1
    • /
    • pp.340-348
    • /
    • 1997
  • The glaucoma, cataract and causing-blindness-diseases have high clinical importance by their severity of the symptoms and possibility of causing visual loss. Glaucoma is caused by an increase in the intraocular pressure, if severe enough, can cause field loss and eventually complete blindness. In cataract, the general clarity of vision is impaired due to a loss of transparency of the chrystalline lens of the eye. The causing-blindness-diseases can be divided to PokMaeng which cause sudden blindness and ChungMaeng, in which visual acuity is losed gradually. In glaucoma, cataract and causing-blindness-diseases, the visual acuity is affected and the patient may complain blurriness, fatigue of eye, visual field loss deficiency or scintillant feeling, vitreous floaters. In this study, 32 patients who have cataract, glaucoma or other causing-blindness-diseases was treated with oriental medicine or acupuncture from July, l996 to May. 1997, and was followed up by their symptoms and visual acuity. 1. In glaucoma patients, intraocular pressure decreased significantry and the symptoms improved positively. 2. In cataract patients, there was no improvement of visual acuity but $40\%$ of patients found their symptoms improved. 3. In causing-blindness-diseases, $57\%$ of patients reported improvement of their symptoms such as blurriness or fatigue of eye. 4. Through oriental medical treatment, the symptoms of glaucoma, cataract and causing-blindness-diseases can be treated effectively. Therefore oriental management seems to be possible to cure glaucoma, cataract and causing-blindness-diseases.

  • PDF

Eyes and Lenses: A Comparison and Differences

  • Egamberdiev, Khojiakbar
    • Journal of Multimedia Information System
    • /
    • v.3 no.2
    • /
    • pp.43-46
    • /
    • 2016
  • This article will compare the following visual categories: visual angle, distinguishable details, sensitivity, and dynamic range. These categories are often considered within the subject of the maximum deviation from the camera eye, an issue which has generated much controversy. Other characteristics such as depth of field, three-dimensional vision, white balance and color, are not considered in this article.

Development of compound eye image quality improvement based on ESRGAN (ESRGAN 기반의 복안영상 품질 향상 알고리즘 개발)

  • Taeyoon Lim;Yongjin Jo;Seokhaeng Heo;Jaekwan Ryu
    • Journal of the Korea Computer Graphics Society
    • /
    • v.30 no.2
    • /
    • pp.11-19
    • /
    • 2024
  • Demand for small biomimetic robots that can carry out reconnaissance missions without being exposed to the enemy in underground spaces and narrow passages is increasing in order to increase the fighting power and survivability of soldiers in wartime situations. A small compound eye image sensor for environmental recognition has advantages such as small size, low aberration, wide angle of view, depth estimation, and HDR that can be used in various ways in the field of vision. However, due to the small lens size, the resolution is low, and the problem of resolution in the fused image obtained from the actual compound eye image occurs. This paper proposes a compound eye image quality enhancement algorithm based on Image Enhancement and ESRGAN to overcome the problem of low resolution. If the proposed algorithm is applied to compound eye image fusion images, image resolution and image quality can be improved, so it is expected that performance improvement results can be obtained in various studies using compound eye cameras.

Extraction of Spatial Characteristics of Cadastral Land Category from RapidEye Satellite Images

  • La, Phu Hien;Huh, Yong;Eo, Yang Dam;Lee, Soo Bong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.6
    • /
    • pp.581-590
    • /
    • 2014
  • With rapid land development, land category should be updated on a regular basis. However, manual field surveys have certain limitations. In this study, attempts were made to extract a feature vector considering spectral signature by parcel, PIMP (Percent Imperviousness), texture, and VIs (Vegetation Indices) based on RapidEye satellite image and cadastral map. A total of nine land categories in which feature vectors were significantly extracted from the images were selected and classified using SVM (Support Vector Machine). According to accuracy assessment, by comparing the cadastral map and classification result, the overall accuracy was 0.74. In the paddy-field category, in particular, PO acc. (producer's accuracy) and US acc. (user's accuracy) were highest at 0.85 and 0.86, respectively.

Development and Design of the Optical System of a Night Scope (Night Scope 광학계의 설계 및 개발)

  • Lee, Dong-Hee;Lim, Yang-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.11-17
    • /
    • 2004
  • We tried to design and manufacture a night scope which is used in the leisure sports field. The whole system consists of an IR light source part, an objective lens part, an intensifier tube part and an eye_piece lens part. We designed an objective lens part to the infinite object imaging optical-system with 80mm focal-length, 40mm effective-aperture and 14mm image-field-size of which the chromatic aberration is reduced by using materials of BK7 and FD4. The resolution of this system is about 25lines/mm at the 40% MTF value criterion. The eye_piece lens is adopted goods to be used commercially to save cost of production. The design technique which gets in this development will be utilized greatly in good developments of the dot, the sight and the day/night riflescope system at the hereafter.

  • PDF

Biometric identification of Black Bengal goat: unique iris pattern matching system vs deep learning approach

  • Menalsh Laishram;Satyendra Nath Mandal;Avijit Haldar;Shubhajyoti Das;Santanu Bera;Rajarshi Samanta
    • Animal Bioscience
    • /
    • v.36 no.6
    • /
    • pp.980-989
    • /
    • 2023
  • Objective: Iris pattern recognition system is well developed and practiced in human, however, there is a scarcity of information on application of iris recognition system in animals at the field conditions where the major challenge is to capture a high-quality iris image from a constantly moving non-cooperative animal even when restrained properly. The aim of the study was to validate and identify Black Bengal goat biometrically to improve animal management in its traceability system. Methods: Forty-nine healthy, disease free, 3 months±6 days old female Black Bengal goats were randomly selected at the farmer's field. Eye images were captured from the left eye of an individual goat at 3, 6, 9, and 12 months of age using a specialized camera made for human iris scanning. iGoat software was used for matching the same individual goats at 3, 6, 9, and 12 months of ages. Resnet152V2 deep learning algorithm was further applied on same image sets to predict matching percentages using only captured eye images without extracting their iris features. Results: The matching threshold computed within and between goats was 55%. The accuracies of template matching of goats at 3, 6, 9, and 12 months of ages were recorded as 81.63%, 90.24%, 44.44%, and 16.66%, respectively. As the accuracies of matching the goats at 9 and 12 months of ages were low and below the minimum threshold matching percentage, this process of iris pattern matching was not acceptable. The validation accuracies of resnet152V2 deep learning model were found 82.49%, 92.68%, 77.17%, and 87.76% for identification of goat at 3, 6, 9, and 12 months of ages, respectively after training the model. Conclusion: This study strongly supported that deep learning method using eye images could be used as a signature for biometric identification of an individual goat.

Camera Calibration and Barrel Undistortion for Fisheye Lens (차량용 어안렌즈 카메라 캘리브레이션 및 왜곡 보정)

  • Heo, Joon-Young;Lee, Dong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1270-1275
    • /
    • 2013
  • A lot of research about camera calibration and lens distortion for wide-angle lens has been made. Especially, calibration for fish-eye lens which has 180 degree FOV(field of view) or above is more tricky, so existing research employed a huge calibration pattern or even 3D pattern. And it is important that calibration parameters (such as distortion coefficients) are suitably initialized to get accurate calibration results. It can be achieved by using manufacturer information or lease-square method for relatively narrow FOV(135, 150 degree) lens. In this paper, without any previous manufacturer information, camera calibration and barrel undistortion for fish-eye lens with over 180 degree FOV are achieved by only using one calibration pattern image. We applied QR decomposition for initialization and Regularization for optimization. With the result of experiment, we verified that our algorithm can achieve camera calibration and image undistortion successfully.

Optimization of optical design for Eye Glass Display

  • Moon, H.C.;Kim, T.H.;Park, K.B.;Park, Y.S.;Seok, J.M.;Kim, H.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1603-1606
    • /
    • 2005
  • Eye Glass Display (EGD) with microdisplay to realize the virtual display can make the large screen, so virtual image has been developed by using microdisplay panel. This paper shows study of low cost lens design and simulation for microdisplay system with 0.6" Liquid Crystal on Silicon (LCoS) panel. Lens design optimized consider to spherical aberration, astigmatism, distortion, and chromatic aberration. Code V is used and it designed an aspheric lens about exit pupil 6mm, eye relief 20mm and 35 degree of field of view (FOV). With the application this aspheric lens to LCOS type's microdisplay, virtual image showed 50 inch at 2m. One side of the aspheric lens was constituted from diffractive optical element (DOE) for the improvement in a performance. It had less than ${\pm}2%$ of distortion value and modulation transfer function in axial had 20% of resolution with 30 lp/mm spatial frequency. The optical system is suitable for display of 0.6"-diagonal with SVGA.

  • PDF

Prism lens design for Eye Glass Display to create virtual display (가상 디스플레이 구현을 위한 Eye Glass Display용 프리즘 렌즈 설계)

  • Kim, Tae-Ha;Mun, Hyeon-Chan;Park, Gwang-Beom;Choe, Seong-Ho;Han, Jin-U;Park, Yeong-Su;Kim, Hwi-Un
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.68-69
    • /
    • 2006
  • Eye Glass Display(EGD)의 광학계를 소형, 경량화 하기 위하여 OLED 마이크로 패널과 프리즘 렌즈를 사용하여 설계하였다. 광학계 설계에 사용된 OLED 마이크로 패널은 0.59"크기의 SVGA($800{\times}600$)급이며, 크기는 0.59"이며, 렌즈는 프리즘 렌즈로 설계되었다. 설계된 프리즘 렌즈는 3연으로 구성되었으며, 각 면은 각각 비회전대칭 비구면으로 tilt와 decenter를 사용하여 광학적 성능을 향상시켰다. 설계된 프리즘 렌즈의 화각(FOV)은 $28^{\circ}$, 왜곡수차는 4% 이내이며, 광학계의 해상도를 나타내는 MTF는 공간주파수 30lp/mm에서 full field가 40%이상의 성능을 나타내었다.

  • PDF