• Title/Summary/Keyword: extremely

Search Result 6,372, Processing Time 0.031 seconds

Review on the Association between Exposure to Extremely Low Frequency-Magnetic Fields (ELF-MF) and Childhood Leukemia (극저주파 자기장의 소아백혈병 발생 위험 고찰)

  • Dong-Uk Park
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.2
    • /
    • pp.57-65
    • /
    • 2023
  • Background: The association between exposure to extremely low frequency-magnetic fields (ELF-MF) and childhood leukemia has been controversial. There is a need to clarify this relationship by summarizing key conclusions from systematic review articles. Objectives: The major aim of this study is to summarize key conclusions from systematic review articles on the association between exposure to ELF-MF and childhood leukemia based on childhood exposure to ELF-MF, proximity from childhood household to high voltage cables, and parental occupational exposure to ELF-MF. Methods: This study was conducted through a brief literature review focusing on systematic, meta-analysis, and pooled analysis methods. We conducted a literature search in PubMed using the key words "ELF-MF" and "childhood leukemia" singly or combined. Results: In 2002, the World Health Organization (WHO)'s International Agency for Research on Cancer (IARC) reviewed two manuscripts to conduct pooled analysis and concluded that there is a significant association between exposure to >0.3 μT or 0.4 μT and childhood leukemia. We found a total of four manuscripts for systematic or pool analysis that have been published since the IARC's conclusion. They consistently concluded that there was a significant association between exposure to >0.4 μT and childhood leukemia compared to ELF-MF exposure to below 0.1 μT. The proximity of children's households to high voltage cable lines and occupational exposure by their parents to ELF-MF during certain periods prior to or during pregnancy were inconsistently associated with childhood leukemia. The study found that many EU countries have implemented precautionary policies to prevent potential childhood leukemia due to exposure to ELF-MF. Conclusions: This study recommends implementing a precautionary policy that includes legal exposure limits for ELF-MF to minimize exposure to ELF-MF.

Optimized QCA SRAM cell and array in nanoscale based on multiplexer with energy and cost analysis

  • Moein Kianpour;Reza Sabbaghi-Nadooshan;Majid Mohammadi;Behzad Ebrahimi
    • Advances in nano research
    • /
    • v.15 no.6
    • /
    • pp.521-531
    • /
    • 2023
  • Quantum-dot cellular automata (QCA) has shown great potential in the nanoscale regime as a replacement for CMOS technology. This work presents a specific approach to static random-access memory (SRAM) cell based on 2:1 multiplexer, 4-bit SRAM array, and 32-bit SRAM array in QCA. By utilizing the proposed SRAM array, a single-layer 16×32-bit SRAM with the read/write capability is presented using an optimized signal distribution network (SDN) crossover technique. In the present study, an extremely-optimized 2:1 multiplexer is proposed, which is used to implement an extremely-optimized SRAM cell. The results of simulation show the superiority of the proposed 2:1 multiplexer and SRAM cell. This study also provides a more efficient and accurate method for calculating QCA costs. The proposed extremely-optimized SRAM cell and SRAM arrays are advantageous in terms of complexity, delay, area, and QCA cost parameters in comparison with previous designs in QCA, CMOS, and FinFET technologies. Moreover, compared to previous designs in QCA and FinFET technologies, the proposed structure saves total energy consisting of overall energy consumption, switching energy dissipation, and leakage energy dissipation. The energy and structural analyses of the proposed scheme are performed in QCAPro and QCADesigner 2.0.3 tools. According to the simulation results and comparison with previous high-quality studies based on QCA and FinFET design approaches, the proposed SRAM reduces the overall energy consumption by 25%, occupies 33% smaller area, and requires 15% fewer cells. Moreover, the QCA cost is reduced by 35% compared to outstanding designs in the literature.

Dynamic Analysis of Underwater Test Collector on Extremely Soft Soil (해저연약지반 시험집광기의 동적거동 해석)

  • Kim, Hyung-Woo;Hong, Sup;Choi, Jong-Su;Yeu, Tae-Yeong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • We conducted a dynamic analysis of an underwater test collector, which operates on extremely soft soil of deep-seafloor. The underwater test collector consists of nodule pick-up device, vehicle tracks, nodule crusher, loading frame and electric-electronic system. The weight of underwater test collector is about 8600 kg. The average normal pressure, that the underwater test collector supports, is about 6.0 kPa. The dynamic analysis model of underwater test collector is developed using commercial software RecurDyn-LM and Visual Fortran 90. A terramechanics model of extremely soft soil is implemented to the software based on user-written subroutine and applied to the dynamic analysis of the underwater test collector model. The dynamic responses of test collector are studied with respect to track velocities, terrain conditions, and coefficients of added mass and drag.

Demand Strength Spectrums of Low-Rise Reinforced Concrete Buildings Consisted of Extremely Brittle, Shear and Flexural Failure Systems (극취성·전단·휨파괴형 수평저항시스템으로 구성된 저층 철근콘크리트 건물의 요구 내력 스펙트럼)

  • Lee, Kang-Seok;Kim, Jeong-Hee;Oh, Jae-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.529-537
    • /
    • 2007
  • The purpose of this study is to discuss how strength and ductility of each system in low-rise reinforced concrete buildings composed of extremely brittle, shear and flexural failure lateral-load resisting systems have influence on seismic capacities of the overall system, which is based on nonlinear seismic response analyses of single-degree-of-freedom structural systems. In order to simulate the triple lateral-load resisting system, structures are idealized as a parallel combination of two modified origin-oriented hysteretic models and a degrading trilinear hysteretic model that fail primarily in extremely brittle, shear and flexure, respectively. Stiffness properties of three models are varied in terms of story shear coefficients, and structures are subjected to various ground motion components. By analyzing these systems, interaction curves of demand strengths of the triple system for various levels of ductility factors are finally derived for practical purposes. The result indicates that demand strength levels derived can be used as a basic information for seismic evaluation and design criteria of low-rise reinforced concrete buildings having the triple lateral-load resisting system.

Physicochemical and Microbial Characteristics of Oiji Prepared with Dry Salting Methods during Low Temperature Storage (저염 건식절임법으로 제조한 오이지의 저온저장 중 이화학적$\cdot$미생물학적 품질특성)

  • Kwon Oh-Yun;Yang Yun-Hyoung;Park Wan Soo;Kim Mee Ree
    • Korean journal of food and cookery science
    • /
    • v.21 no.4 s.88
    • /
    • pp.545-555
    • /
    • 2005
  • The physicochemical and microbial characteristics of Oiji prepared with dry salting method, which has been used industrially for industry, were investigated. Low salting and low storage temperature were employed:extremely low salting extremely low temperature; ESET $(5\%,\;0^{\circ}C)$, very low salting extremely low temperature;VSET $(10\%,\;0^{\circ}C)$, extremely low salting very low temperature; ESVT$(5\%,\;5^{\circ}C)$, low salting very low temperature; VSVT$(10\%,\;5^{\circ}C)$ and high salting low temperature;HSLT$(30\%,\;10^{\circ}C)$ for control. Acidity was lower, and pH was higher in VSET, in of which the fermentation pattern was similar with that of HSLT The time required to reach the optimum acidity ($0.3\%$ lactic acid) was longer delayed for VSET (168 days), than for compared to ESVT (51 days). During storage of Oiji, greenness (-a) as measured with of the Hunter color system wasshowed the highest in VSET, and the lowest while in ESVT, the lowest. Total microbial and lactic acid bacteria counts number were the lowest in HSLT and VSET and were the lowest than in other groups, while the highest in ESVT. Yeast was not detected in HSLT, but was the highest while in VSVT. E coli coliform and listeria were detected in the $5\%$ salting groups, although Salmonella was not detected in any of the all groups. Texture profile analysis demonstrated exhibited that fracturability and hardness were highest in HSLT and VSET, compared to the other groups. Scores of over-all preference for ESVT and HSLT were higher atwith 6.3 and 6.2, respectively, compared to the other products. Based on these results, lower saltiness less than $10\%$ and lower storage temperature (less than $5^{\circ}C$) condition was optimum for maximizing the better for good quality of industrial Oiji preparation in industry.

Low Complexity Video Encoding Using Turbo Decoding Error Concealments for Sensor Network Application (센서네트워크상의 응용을 위한 터보 복호화 오류정정 기법을 이용한 경량화 비디오 부호화 방법)

  • Ko, Bong-Hyuck;Shim, Hyuk-Jae;Jeon, Byeung-Woo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.11-21
    • /
    • 2008
  • In conventional video coding, the complexity of encoder is much higher than that of decoder. However, as more needs arises for extremely simple encoder in environments having constrained energy such as sensor network, much investigation has been carried out for eliminating motion prediction/compensation claiming most complexity and energy in encoder. The Wyner-Ziv coding, one of the representative schemes for the problem, reconstructs video at decoder by correcting noise on side information using channel coding technique such as turbo code. Since the encoder generates only parity bits without performing any type of processes extracting correlation information between frames, it has an extremely simple structure. However, turbo decoding errors occur in noisy side information. When there are high-motion or occlusion between frames, more turbo decoding errors appear in reconstructed frame and look like Salt & Pepper noise. This severely deteriorates subjective video quality even though such noise rarely occurs. In this paper, we propose a computationally extremely light encoder based on symbol-level Wyner-Ziv coding technique and a new corresponding decoder which, based on a decision whether a pixel has error or not, applies median filter selectively in order to minimize loss of texture detail from filtering. The proposed method claims extremely low encoder complexity and shows improvements both in subjective quality and PSNR. Our experiments have verified average PSNR gain of up to 0.8dB.

Brief Review on Exposure Characteristics, Monitoring Instruments and Threshold Limit Values for Extremely Low Frequency-Magnetic Field (ELF-MF) (직업성 극저주파 자기장 노출평가와 노출 기준에 대한 쟁점 고찰)

  • Dong-Uk, Park;Seunghee, Lee;Kyung Ehi, Zoh
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.381-392
    • /
    • 2022
  • Objectives: Objective of this study is to review briefly exposure characteristics, monitoring instruments and threshold limit values for extremely low frequency-magnetic field (ELF-MF) methods. This study was undertaken through brief literature review. We performed a literature search in PubMed to identify ELF-MF studies conducted in workplaces. Initial search keywords such as 'extremely low frequency-magnetic field (ELF-MF)' and 'electromagnetic fields (EMF)' combined or singly. We limited our review to occupational rather than general nonworkplace environmental exposures. Methods: The contents we reviewed: key industry and occupations generating ELF-MF, several direct-reading instruments monitoring ELF-MF and threshold limit values (TLV) preventing health effects may be caused by the exposure to ELF-MF. Results: The industries related to the generation and supply of electricity, electrolytic installations, welding, and induction heating and more were regarded as high ELF-MF exposure industries. All jobs handling or employed performed in power cable lines, electrical wiring, and electrical equipment are found to be exposed to ELF-MF. Threshold or ceiling limit, 1,000 µT, is established to prevent acute effects of exposure to low-frequency EMFs on the nervous system: the direct stimulation of nerve and muscle tissues and the induction of retinal phosphenes. The International Agency for Research on Cancer (IARC) has classified ELF-MF as possibly carcinogenic to humans chiefly based on epidemiological studies on childhood leukemia. However, a causal relationship between magnetic fields and several types of cancer including childhood leukemia has not been established nor has any other long-term effects. Risk management using precautionary measures, has been initiated by the US and EU to prevent chronic health effects related to ELF-MF exposure in workplaces. Conclusion: This study recommends the implementation of various measures such as theestablishment of occupational exposure limit values for ELF-MF and precautionary principle to prevent potential chronic occupational health effects may be caused by ELF-MF in Korea.

Mucoepidermoid Tumor OF LUNG: Report Of A Case (폐에 발생한 점액성 상피종 1례 보고)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.11 no.3
    • /
    • pp.269-272
    • /
    • 1978
  • Mucoepidermoid tumors of lung are extremely uncommon, with fewer than 50 such cases having been reported. The degree of tumor malignancy has been discussed by some authors without any definite conclusion. This report describes a case of this, occurred in a 53-year-old female, having a highly malignant process and finally confirmed by postoperative histopathological evaluation.

  • PDF