• Title/Summary/Keyword: extraction type

Search Result 976, Processing Time 0.033 seconds

Stability Analysis of Multiple Thermal Energy Storage Caverns Using a Coupled Thermal-Mechanical Model (열-역학적 연계해석 모델을 이용한 다중 열저장공동 안정성 분석)

  • Kim, Hyunwoo;Park, Dohyun;Park, Eui-Seob;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.24 no.4
    • /
    • pp.297-307
    • /
    • 2014
  • Cavern Thermal Energy Storage system stores thermal energy in caverns to recover industrial waste heat or avoid the sporadic characteristics of renewable-energy resources, and its advantages include high injection-and-extraction powers and the flexibility in selecting a storage medium. In the present study, the structural stability of rock mass pillar between these silo-type storage caverns was assessed using a coupled thermal-mechanical model in $FLAC^{3D}$. The results of numerical simulations showed that thermal stresses due to long-term storage depended on pillar width and had significant effect on the pillar stability. A sensitivity analysis of main factors indicated that the influence on the pillar stability increased in the order cavern depth < pillar width < in situ condition. It was suggested that two identical caverns should be separated by at least one diameter of the cavern and small-diameter shaft neighboring the cavern should be separated by more than half of the cavern diameter. Meanwhile, when the line of centers of two caverns was parallel to the direction of maximum horizontal principal stress, the shielding effect of the caverns could minimize an adverse effect caused by a large horizontal stress.

The inhibitory effects of hot water and ethanol extract of Gamichungsangbohatang on cytokines related to ashtma (가미청상보하탕(加味淸上補下湯) 열수 및 에탄올 추출물이 천식 관련 cytokine 분비에 미치는 영향)

  • Jeong, Seung-Yeon;Lee, Sung-Hun;Hwang, Joon-Ho;Lee, Kun-Young;Kim, Jin-Ju;Jung, Hee-Jae;Rhee, Hyung-Koo;Jung, Sung-Ki
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.2
    • /
    • pp.521-532
    • /
    • 2006
  • Backgrounds and Objectives: A major goat in asthma therapy isto reduce or prevent the inflammatory response associated with bronchial hyperresponsiveness, reversible airway obstruction and airway remodelling. Many studies have shown that eosinophilic infiltration is a prominent feathure in the pathophysiology of asthma. The importance of the Presence of eosinophils in the airways of asthmatics has long been recognized, but the mechanism by which these cells are recruited and retained in the lung are only now being elucidated Production of chemotactic cytokines by bronchial epithelial cells may contribute to the local accumulation of eosinophils in Patients with bronchial asthma. This study was designed to investigate the inhibitory effect of extraction of herbal dicoction, Gamichungsangbohatang(GMCSBHT) on eosinophil chemotactic cytokines. Material and Methods:We used water and 70% ethanol extracts of GMCSBHT and pulmonary epithelial cell lines A549(human type II -like epithelial cells). We estimated cytotoxic effects of GMCSBHT, and estimated the effects of water and 70% ethanol extracts of GMCSBHT on chemokines from prestimulated A549 cells by sandwich ELISA. Results: Chemokines of eotaxin, IL-8 were inhibited by GMCSBHT in dose-dependent manner. And ethanol extract of GMCSBHT has more inhibitory effects on eotaxin, IL-8 than hot water extract. Conculusions: These findings indicate that the supression of the expression of chemokines can be accomplished by GMCSBHT treatment, so GMCSBHT may inhibit the iuflammatory process by eosinophils in asthma.

  • PDF

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

The Evaluation of Recovery Rate of Radioimmunoassay Using Certified Reference Material (CRM) (인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가)

  • Choi, Sung Hee;Shin, Sun Young;Lim, So Hee;Hong, Mee Kyung;Noh, Gyeong Woon;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.158-162
    • /
    • 2014
  • Purpose: Reference material (RM) is defined as material that is safe and homogeneous enough about specified characteristic that is made with a purpose of using test of measurement or nominal characteristic. Certified reference material (CRM), which is issued by authorized organization, is defined as reference material that provides characteristic value, link uncertainty and retroactivity. The purpose of this paper was to evaluate recovery of radioimmunoassay by Certified Reference Material enclosed with a certificate and therefore to enhance reliability of test. Materials and Methods: WHO certified reference material is purchased from NIBSC (National Institute for Biological Standard and Control, United Kingdom) and made of 3 levels that are C-1 (low concentration), C-2 (medium concentration) and C-3 (high concentration) and measured for kit at the Seoul National University Hospital. Recovery rate is evaluated after measurement at four different days. Results: Recovery rate results using WHO certified reference material are T4 90%, Ferritin 88%, PSA 94%, Prolactin 99%, AFP 94% and TSH 93%. Conclusion: A procedure that appropriate accuracy, precision, specificity, sensitivity, reproducibility, and validate on the subject of kit for radioimmunoassay is essential. Recovery rate assay as extraction efficiency of analysis process is percent about already measuring results of analysis result after all measuring process. This is very important assessment standards of performance evaluation of immunoassay kit. Recovery rate results of 6 type used WHO CRM are satisfactory to 88~99%. This demonstrates that the radioimmunoassay is a very accurate measurement, which is very effectively utilized in clinical practice.

  • PDF

A Study on Chloride Binding Capacity of Various Blended Concretes at Early Age (초기재령에서 각종 혼합콘크리트의 염소이온 고정화능력에 관한 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.133-142
    • /
    • 2008
  • This paper studies the early-aged chloride binding capacity of various blended concretes including OPC(ordinary Portland cement), PFA(pulversied fly ash), GGBFS(ground granulated blast furnace slag) and SF(silica fume) cement paste. Cement pastes with 0.4 of a free water/binder ratio were cast with chloride admixed in mixing water, which ranged from 0.1 to 3.0% by weight of cement and different replacement ratios for the PFA, GGBFS and SF were used. The content of chloride in each paste was measured using water extraction method after 7 days curing. It was found that the chloride binding capacity strongly depends on binder type, replacement ratio and total chloride content. An increase in total chloride results in a decrease in the chloride binding, because of the restriction of the binding capacity of cement matrix. For the pastes containing maximum level of PFA(30%) and GGBFS(60%) replacement in this study, the chloride binding capacity was lower than those of OPC paste, and an increase in SF resulted in decreased chloride binding, which are ascribed to a latent hydration of pozzolanic materials and a fall in the pH of the pore solution, respectively. The chloride binding capacity at 7 days shows that the order of the resistance to chloride-induced corrosion is 30%PFA > 10%SF > 60%GGBFS > OPC, when chlorides are internally intruded in concrete. In addition, it is found that the binding behaviour of all binders are well described by both the Langmuir and Freundlich isotherms.

Image Registration and Fusion between Passive Millimeter Wave Images and Visual Images (수동형 멀리미터파 영상과 가시 영상과의 정합 및 융합에 관한 연구)

  • Lee, Hyoung;Lee, Dong-Su;Yeom, Seok-Won;Son, Jung-Young;Guschin, Vladmir P.;Kim, Shin-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6C
    • /
    • pp.349-354
    • /
    • 2011
  • Passive millimeter wave imaging has the capability of detecting concealed objects under clothing. Also, passive millimeter imaging can obtain interpretable images under low visibility conditions like rain, fog, smoke, and dust. However, the image quality is often degraded due to low spatial resolution, low signal level, and low temperature resolution. This paper addresses image registration and fusion between passive millimeter images and visual images. The goal of this study is to combine and visualize two different types of information together: human subject's identity and concealed objects. The image registration process is composed of body boundary detection and an affine transform maximizing cross-correlation coefficients of two edge images. The image fusion process comprises three stages: discrete wavelet transform for image decomposition, a fusion rule for merging the coefficients, and the inverse transform for image synthesis. In the experiments, various types of metallic and non-metallic objects such as a knife, gel or liquid type beauty aids and a phone are detected by passive millimeter wave imaging. The registration and fusion process can visualize the meaningful information from two different types of sensors.

Sedation for Dental Treatment of Patients with Disabilities (장애인 환자의 치과치료를 위한 진정법)

  • Bing, Jung-Ho;Jeon, Jae-Yoon;Jung, Se-Hwa;Hwang, Kyung-Gyun;Park, Chang-Joo;Seo, Kwang-Suk;Kim, Hyun-Jeong;Yum, Kwang-Won;Shim, Kwang-Sup
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.7 no.2
    • /
    • pp.114-119
    • /
    • 2007
  • Background: Dental disabilities mean the poor cooperation for dental treatment because of patient's inherent disability, severe fear and anxiety, and communication problem. Sedation and general anesthesia are usually used for behavioral control in dentally disabled patients. In particular, sedation (conscious and deep) can help them to tolerate the proper dental treatment effectively and safely. Methods: From March 2002 to September 2007, total 35 sedation were carried out in 33 patients (male : female = 20 : 13) with dental disabilities at Seoul National University Dental Hospital and Hanyang University Medical Center. Patients' dental charts and sedation records were retrospectively reviewed. Results: Tooth extraction (19 cases) was the most common dental treatment performed under intravenous sedation (30 cases). Occasionally, inhalation sedation using Sevoflurane 1-2% was adapted (5 cases). Deep sedation (28 cases) was carried out using midazolam 2-3 mg bolus injection and propofol infusion via TCI (4.2 ${\pm}$ 0.9 mg/kg/h), and conscious sedation (7 cases) was carried out using midazolam bolus onlywithout severe complications. The duration of dental treatment was 25.5 ${\pm}$ 12.3 min and that of sedation was 43.2 ${\pm}$ 9.7 min. Conclusion: Sedation for dentally disabledpatients should be selected for effective behavioral control in conjunction with general anesthesia, considering the duration and pain-evoking potentials of dental treatment, the type and severity of patients' disabilities, and the experience of dental anesthesiologists altogether.

  • PDF

Isolation and Characterization of Pepsin-soluble Collagens from Bones, Skins, and Tendons in Duck Feet

  • Kim, Hyun-Wook;Yeo, In-Jun;Hwang, Ko-Eun;Song, Dong-Heon;Kim, Yong-Jae;Ham, Youn-Kyung;Jeong, Tae-Jun;Choi, Yun-Sang;Kim, Cheon-Jei
    • Food Science of Animal Resources
    • /
    • v.36 no.5
    • /
    • pp.665-670
    • /
    • 2016
  • The objectives of this study were conducted to characterize pepsin-soluble collagen (PSC) extracted from bones (PSC-B), skins (PSC-S), and tendons (PSC-T) of duck feet and to determine their thermal and structural properties, for better practical application of each part of duck feet as a novel source for collagen. PSC was extracted from each part of duck feet by using 0.5 M acetic acid containing 5% (w/w) pepsin. Electrophoretic patterns showed that the ratio between α1 and α2 chains, which are subunit polypeptides forming collagen triple helix, was approximately 1:1 in all PSCs of duck feet. PSC-B had slightly higher molecular weights for α1 and α2 chains than PSC-S and PSC-T. From the results of differential scanning calorimetry (DSC), higher onset (beginning point of melting) and peak temperatures (maximum point of curve) were found at PSC-B compared to PSC-S and PSC-T (p<0.05). Fourier transform infrared spectroscopy (FT-IR) presented that PSC-S and PSC-T had similar intermolecular structures and chemical bonds, whereas PSC-B exhibited slight difference in amide A region. Irregular dense sheet-like films linked by random-coiled filaments were observed similarly. Our findings indicate that PSCs of duck feet might be characterized similarly as a mixture of collagen type I and II and suggest that duck feet could be used for collagen extraction without deboning and/or separation processes.

Determination of Synthetic Food Colours by HPLC with Photodiode Array Detector (HPLC를 이용한 타르색소의 분리정량)

  • Yang, Ho-Chul;Heo, Nam-Chil
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.30-35
    • /
    • 1999
  • A simple, rapid, efficient method is for extraction of 13 synthetic water-soluble food colours (Tartrazine, Amarnth, Indigo carmine, New coccine, Sunset yellow FCF, Allura red AC, Eosine, Fast Green FCF, Brilliant Blue FCF, Erythrosine, Acid red, phloxine, Rose Bengal) by polyamide resin and for their quantitative by high performance liquid chromatography (HPLC). Colours (coal-tar dyes) were extracted with polyamide resin and then determinated by HPLC. The HPLC conditions using a reverse phase partition type column $(Nova-pak\;C_{18})$, photodiode array (PDA) detector and 1% Ammonium acetate / 60% acetonitrile in water as eluent, were acceptable for various kinds of colorants. By the use of the proposed method, a survey of coal-tar dyes was carried out on 20 samples and that were detected $4.76{\sim}133.47\;ppm$.

  • PDF

Processing Conditions of Dried Shellfish Condiments (패류를 이용한 분말조미료 가공조건)

  • BAE Tae-Jin;CHOI Ok-Soo;KANG Hoon-I
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.2
    • /
    • pp.175-179
    • /
    • 1999
  • Processing conditions for dried condiments with oyster, pen shell and cockle shell were investigated. The enzymatic hydrolysis for 3 hours was more profitable than hydrothermal extraction to develop flavoring matters from oyster, pen shell and cockle shell. As a result of omission tests, nucleotides were predominated in the taste compounds of shellfish hydrolysates rather than free amino acids, and the contribution of nucleotides and free amino acids to the taste of shellfish hydrolysates was remarkable. The major flavoring components of shellfish hydrolysates were free amino acids and oligopeptides below 500 dalton. When shellfish hydrolysates were separated with membrane (molecular weight cutoff 500 dalton) for recovering flayer, recovering yields of amino type nitrogen were $92.1\~92.8\%$. Moisture contents of dried shellfish condiments prepared with pretense hydrolyzed oyster, pen shell and cockle shell were $3.5\%,\;3.8\%$ and $3.7\%$, respectively. Contents of total nitrogen were $69.4\%,\;78.8\%$ and $74.2\%$, and those of amino nitrogen were $45.5\%,\;48.9\%$ and $45.4\%$, respectively. Drying yield, solubility and absorption rates at Aw 0.88 were $11.7\%,\;78.4\%$ and $6.8\%$ in oyster, $8.2\%,\;73.6\%$ and $6.1\%$ in pen shell, $9.8\%,\;76.9\%$ and $6.6\%$ in cockle shell, respectively.

  • PDF