• 제목/요약/키워드: extraction chromatographic resin

검색결과 8건 처리시간 0.02초

유도결합플라스마 질량분석을 위한 사용후핵연료 중 테크네튬-99의 추출크로마토그래피 분리 (Extraction Chromatographic Separation of Technetium-99 from Spent Nuclear Fuels for Its Determination by Inductively Coupled Plasma-Mass Spectrometry)

  • 서무열;이창헌;한선호;박영재;지광용;김원호
    • 분석과학
    • /
    • 제17권5호
    • /
    • pp.438-442
    • /
    • 2004
  • To determine the contents of $^{99}Tc$ in the spent PWR (pressurized water reactor) nuclear fuels by ICP-MS (inductively coupled plasma-mass spectrometry), a technetium separation method using an extraction chromatographic resin (TEVA Spec resin) has been established. $^{99}Tc$ was separated from a spent PWR nuclear fuel solution by this separation procedure and its concentration was determined by ICP-MS. The result agrees well with the value calculated by the program ORIGEN 2 and also the value measured by AG MP-1 resin/ICP-MS method described in our previous paper. It can be concluded that the present separation procedure is superior to the AG MP-1 resin procedure with respect to the time required for technetium separation as well as the efficiency of decontamination from other radioactive nuclides.

스트론튬 선택적이온교환수지$(Sr.\;Spec^{TM})$를 이용한 환경시료중의 방사성 스트론튬의 분리 (Separation of Radiostrontium from Environmental Sample Using Strontim Selective Chromatographic Resin$(Sr.\;Spec^{TM})$)

  • 홍광희;이창우;최용호;이명호
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.1-7
    • /
    • 1995
  • 스트론튬선택성을 갖는 크로마토그래피용 수지인 $Sr-Spec^{TM}$을 이용한 환경시료중 토양시료와 물시료에 대한 방사성 스트론들 분리를 고찰하였다. 이 수지는 질산수용액에서 스트론튬과 큰 결합능력을 가졌으며, 다량의 칼슘원소의 존재에서도 스트론튬분리를 할 수 있는 선택성을 가졌다. 그러나 K나 Ba와 같은 방해원소에 의해서는 스트론튬 추출능력이 감소하였고, 때문에 토양시료중의 스트론튬 분석시에는 이러한 방해원소의 제거단계가 필요하였다. 그러나 물시료증 스트론튬분석에서는 이 수지를 사용함으로써 간편하고 효율높게 분리할 수 있었다.

  • PDF

A rapid separation of Cs, Sr and Ba using gas pressurized extraction chromatography with inductively coupled plasma-mass spectrometry

  • Sojin Jeong;Jihye Kim;Hanul Cho;Hwakyeung Jeong;Byungman Kang;Sang Ho Lim
    • 분석과학
    • /
    • 제37권2호
    • /
    • pp.123-129
    • /
    • 2024
  • We present a rapid method for the determination of Cs, Sr, and Ba, heat generators found in highly active liquid wastes, by gas-pressurized extraction chromatography (GPEC) using a column containing a cation-exchange resin. GPEC is a microscale column chromatographic technique that uses a constant flow rate of solvent (0.07 mL/min) with pressurized nitrogen gas supplied through a valve. In particular, because this method uses a small sample volume (a few hundred microliters), it produces less chemical waste and allows for faster separation compared to traditional column chromatography. In this study, we evaluated the separation of Cs, Sr, and Ba using GPEC. The eluate from the column (GPEC or conventional column chromatography) was quantitatively analyzed using inductively coupled plasma-mass spectrometry to measure the column recovery and precision. The column reproducibility of the proposed GPEC system (RSDs of recoveries) ranged from 2.7 to 4.1 %, and the column recoveries for the three elements ranged from 72 to 98% when aqueous HCl was used as the eluent. The GPEC results are slightly different in efficiency and separation resolution compared to those of conventional column chromatography because of the differences in the eluent flow rate as well as the internal diameter and length of the column. However, the two methods had similar recoveries for Cs and Sr, and the precision of GPEC was improved by two-fold. Remarkably, the solvent volume required for GPEC analysis was five times lower than that of the conventional method, and the total analysis time was 11 times shorter.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • 제13권4호
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

P507 추출수지를 이용한 중희토류 원소(Gd, Tb, Dy)의 흡탈착 분리특성에 관한 연구 (Separation and Adsorption-Desorption Characteristics of Heavy Rare Earth Elements (Gd, Tb, Dy) using P507 Resin)

  • 이성은;김정운;전종혁;전홍명;이진영;한춘
    • 자원리싸이클링
    • /
    • 제25권4호
    • /
    • pp.60-67
    • /
    • 2016
  • 본 연구에서는 P507을 포함하고 있는 추출수지를 사용하여 중희토류 원소인 Gd, Tb, Dy의 흡 탈착 반응 메커니즘을 고찰하고 분리를 위한 최적 크로마토그래피법의 반응조건을 도출하였다. 흡 탈착 반응 메커니즘은 흡착등온식인 Langmuir, Freundlich 흡착등온식과, 흡착속도모델인 유사 1차, 2차 반응속도식을 적용하여 고찰하였다. 중희토류 원소의 흡착반응은 단분자층으로 일어난다고 가정하여 흡착등온식을 적용하였고, 잘 일치하여 흡착반응이 단분자층으로 이루어짐을 추측할 수 있었다. 시간별 실험을 진행하여 유사 1차, 2차 반응속도식에 적용한 결과 유사 2차 반응속도식이 추출수지의 중희토류 흡착 메커니즘을 더 잘 표현하였고, 평형흡착량의 실험값은 이론값에 부합하였다. 크로마토그래피법을 이용하여 용리액 HCl 0.25 M 농도조건에서 ${\alpha}^{Tb}_{Gd}=1.24$, ${\alpha}^{Dy}_{Tb}=1.03$으로 분리계수 1이상의 높은 분리조건을 확인하였다. HCl 용리액을 사용하였을 때, 용리액의 농도가 높을수록 분리도는 감소하고 용출구간은 줄어드는 경향을 확인하였다.

Gas Chromatography/Mass Spectrometry에 의한 우육 중의 잔류 Zeranol, Zearalenone 및 그 대사산물들의 동시 분석법에 대한 연구 (A Study on the Simultaneous Determination of Residual Zeranol, Zearalenone and Their Metabolites in Beef by Gas Chromatography/Mass Spectrometry)

  • 이은섭;이용욱
    • 한국식품위생안전성학회지
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 1994
  • A Simultaneous determination method was improved for the determination and confirmation of zeranol, zearalenone, as well as their isomers and metabolites, in beef. The analytes were extracted from tissue by CH3CN, hydrolyzed enzymatically(for glucuronide conjugates), cleaned up by a strong basic anion exchange resin combined with a liquid/liquid partitioning, derivatized using MSTFA and confirmed, quantified by GC/MS/SIM with a internal standard, zearalane. The results were as follows : (1) all the estrogens were separated on the GC/MS chromatogram under the extraction method and the chromatographic conditions improved, the retention times of zearalane-TMS2, zearalanone-TMS2, zearalenone-TMS2, zeranol-TMS3, taleranol-TMS3, and $\alpha$-zearalenol-TMS3, $\beta$-zearalenol-TMS3, were 18.49, 19.44, 19.63, 19.71, 19.79 and 19.99, 20.08 minutes, respectively. (2) The calibration curves of residual zeranol, zearalenone and their metabolites showed constantly linear(r=0.99) in the range of 5~20 ng. The minimum detection concentration of residual zeranol, zearalenone and their metabolites was 1 ppb. (3) The total average recovery of residual zeranol, zearalenone and their metabolites from spiked beef was 60.2%(CV=29.7%) at the 1 ppb and 63.5%(CV=26.5) at the 2 ppb, 72.9%(CV=18.2%) at the 4 ppb. (4) The preservation method for 6 estrogens was improved for the fast running time(21 min) and MSTFA was utilized for derivatizing 6 estrogens for improvement of recovery, for good resolution, for characteristic mass spectra unlike Jose's method and Tina's method. The utilization of zearalane as internal standard showed good quantification result for zeranol, zearalenone, as well as their isomers and metabolites, in beef.

  • PDF

$TBP/XAD-16/HNO_3$추출 크로마토그래피에 의한 모의 사용후핵연료 용해용액 중 미량 핵분열생성물 원소의 분리 (Separation of Fission Product Elements from Synthetic Dissolver Solutions of Spent Pressurized Water Reactor Fuels by $TBP/XAD-16/HNO_3$Extraction Chromatography)

  • 이창헌;최광순;김정석;최계천;지광용;김원호
    • 대한화학회지
    • /
    • 제45권4호
    • /
    • pp.304-311
    • /
    • 2001
  • 경수로 사용후 핵 연료에 미량 함유되어 있는 핵분열생성물을 유도 결합 플라스마 원자방출분광법(ICP-AES)으로 분석하기 위하여 우라늄으로부터 학분열생성물을 추출 크로마토그래피로 분리, 회수하는 방법을 검토하였다. 우라늄 분리 분야에서 잘 알려져 있는 tri-n-butyl phosphate(TBP)를 추출제로 사용하여 몇 가지 Amberlite XAD 다공성 수지들에 대한 침윤능을 비교한 후 TPB침윤양이 가장 큰 Amberlite XAD-16을 지지체로 선택하였다. 사용후핵연료 용해용액과 화학조성이 유사한 모의 사용후핵연료 용해용액을 사용하여 TBP 침윤수지에 대한 핵분열생성물 원소들의 흡착거동을 조사하고, 분리에 미치는 여러 변수들을 최적화 하였다. Pd 및 Ru을 제외한 대부분의 핵분열생성물 원소들을 정밀도 3.1% 이하의 범위에서 정량적으로 회수할 수 있었다.

  • PDF

환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축 (A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC)

  • 이대운;김진영;박영훈;문명희
    • 분석과학
    • /
    • 제7권1호
    • /
    • pp.33-39
    • /
    • 1994
  • 환경오염수에 미량 존재하는 페놀류를 정량하기 위한 분석법의 개발을 위하여 8가지 페놀류를 대상 시료로, 고체상 추출법을 이용한 전처리 방법을 연구하였다. XAD-4와 Dowex $1{\times}8$ 수지를 연결하여 HPLC로 분석하는 온 라인 시스템을 만들어 농축과 분리의 선택성을 높이며 자동화에 중점을 두었다. 시료를 XAD-4 컬럼에 용리시켜 페놀류를 분자흡착으로 농축시킨 후 염기성 아세토니트릴을 용리시켜 탈착시키고 계속해서 Dowex $1{\times}8$ 컬럼에 음이온교환으로 페놀류만을 선택적으로 재흡착시킨다. Dowex $1{\times}8$ 컬럼에 재흡착된 페놀류를 물로 세척한 후 HCl을 포함하는 메탄올 용액으로 재탈착시킨다. 전처리 단계는 switching 밸브에 의해 온 라인으로 연결하였고 탈착된 페놀류를 HPLC에 직접 주입하여 신속하고 신뢰성 있는 정량이 가능하였다. 각 페놀류는 90% 이상의 회수율을 나타내었다. 본 분석법의 활용성을 평가하기 위해 환경오염수에서 페놀류와 공존 가능한 유기 화합물들을 첨가시켜 조제한 실험실적 오염수를 만들어 방해 효과를 조사한 결과, 페놀류만을 선택적으로 농축-분석할 수 있었다.

  • PDF