• Title/Summary/Keyword: extraction chromatographic resin

Search Result 8, Processing Time 0.023 seconds

Extraction Chromatographic Separation of Technetium-99 from Spent Nuclear Fuels for Its Determination by Inductively Coupled Plasma-Mass Spectrometry (유도결합플라스마 질량분석을 위한 사용후핵연료 중 테크네튬-99의 추출크로마토그래피 분리)

  • Suh, Moo-Yul;Lee, Chang-Heon;Han, Sun-Ho;Park, Yeong-Jae;Jee, Kwang-Yong;Kim, Won-Ho
    • Analytical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.438-442
    • /
    • 2004
  • To determine the contents of $^{99}Tc$ in the spent PWR (pressurized water reactor) nuclear fuels by ICP-MS (inductively coupled plasma-mass spectrometry), a technetium separation method using an extraction chromatographic resin (TEVA Spec resin) has been established. $^{99}Tc$ was separated from a spent PWR nuclear fuel solution by this separation procedure and its concentration was determined by ICP-MS. The result agrees well with the value calculated by the program ORIGEN 2 and also the value measured by AG MP-1 resin/ICP-MS method described in our previous paper. It can be concluded that the present separation procedure is superior to the AG MP-1 resin procedure with respect to the time required for technetium separation as well as the efficiency of decontamination from other radioactive nuclides.

Separation of Radiostrontium from Environmental Sample Using Strontim Selective Chromatographic Resin$(Sr.\;Spec^{TM})$ (스트론튬 선택적이온교환수지$(Sr.\;Spec^{TM})$를 이용한 환경시료중의 방사성 스트론튬의 분리)

  • Hong, Kwang-Hee;Lee, Chang-Woo;Choi, Yong-Ho;Lee, Myung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • Strontium selective chromatographic material $(Sr-Spec^{TM})$ was investigated for separation of radiostrontium from environmental soil and water sample. This chromatographic material has great capacity of binding of strontium ion in nitric acid media, and has selectivity to permit the separation of stontium from bulk amount of calcium. But the extraction of strontium was reduced by the other interfering ions such as K and Ba. So, in order to apply this material to the soil sample, prior removal treatment of K and Ba was needed. But the Sr-Spec material could provides simple and effective methods for the separation and removal of radiostrontium from liquid sample.

  • PDF

A rapid separation of Cs, Sr and Ba using gas pressurized extraction chromatography with inductively coupled plasma-mass spectrometry

  • Sojin Jeong;Jihye Kim;Hanul Cho;Hwakyeung Jeong;Byungman Kang;Sang Ho Lim
    • Analytical Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.123-129
    • /
    • 2024
  • We present a rapid method for the determination of Cs, Sr, and Ba, heat generators found in highly active liquid wastes, by gas-pressurized extraction chromatography (GPEC) using a column containing a cation-exchange resin. GPEC is a microscale column chromatographic technique that uses a constant flow rate of solvent (0.07 mL/min) with pressurized nitrogen gas supplied through a valve. In particular, because this method uses a small sample volume (a few hundred microliters), it produces less chemical waste and allows for faster separation compared to traditional column chromatography. In this study, we evaluated the separation of Cs, Sr, and Ba using GPEC. The eluate from the column (GPEC or conventional column chromatography) was quantitatively analyzed using inductively coupled plasma-mass spectrometry to measure the column recovery and precision. The column reproducibility of the proposed GPEC system (RSDs of recoveries) ranged from 2.7 to 4.1 %, and the column recoveries for the three elements ranged from 72 to 98% when aqueous HCl was used as the eluent. The GPEC results are slightly different in efficiency and separation resolution compared to those of conventional column chromatography because of the differences in the eluent flow rate as well as the internal diameter and length of the column. However, the two methods had similar recoveries for Cs and Sr, and the precision of GPEC was improved by two-fold. Remarkably, the solvent volume required for GPEC analysis was five times lower than that of the conventional method, and the total analysis time was 11 times shorter.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Separation and Adsorption-Desorption Characteristics of Heavy Rare Earth Elements (Gd, Tb, Dy) using P507 Resin (P507 추출수지를 이용한 중희토류 원소(Gd, Tb, Dy)의 흡탈착 분리특성에 관한 연구)

  • Lee, Sungeun;Kim, Joung Woon;Jeon, Jong Hyuk;Jun, Hong Myeong;Lee, Jin Young;Han, Choon
    • Resources Recycling
    • /
    • v.25 no.4
    • /
    • pp.60-67
    • /
    • 2016
  • This study was conducted to establish the adsorption-desorption mechanism and the optimum condition of chromatographic operation for separations of heavy rare earth elements (Gd, Tb, Dy) using a p507-containing resin. By employing Langmuir and Freundlich isotherm together with pseudo first and second order kinetics, absorption-desorption reaction mechanism was investigated. Langmuir and Freundlich isotherm was applied under assumption that adsorption reaction occurs in form of monolayer, and because the result was identical to the assumption, now we know adsorption of heavy rare earth elements occurs in form of monolayer. Concerning the pseudo first and second order kinetic, the pseudo second order seemed to be more suitable to represent heavy rare earth element adsorption mechanism. By using the extraction chromatography to separate heavy rare earth elements, ${\alpha}^{Tb}_{Gd}=1.24$, and ${\alpha}^{Dy}_{Tb}=1.03$ were confirmed in eluent HCl 0.25 M which indicates almost perfect separations of three elements. Furthermore, as concentrations of eluent became higher, the resolution value decreased and the elution area got shortened.

A Study on the Simultaneous Determination of Residual Zeranol, Zearalenone and Their Metabolites in Beef by Gas Chromatography/Mass Spectrometry (Gas Chromatography/Mass Spectrometry에 의한 우육 중의 잔류 Zeranol, Zearalenone 및 그 대사산물들의 동시 분석법에 대한 연구)

  • 이은섭;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1994
  • A Simultaneous determination method was improved for the determination and confirmation of zeranol, zearalenone, as well as their isomers and metabolites, in beef. The analytes were extracted from tissue by CH3CN, hydrolyzed enzymatically(for glucuronide conjugates), cleaned up by a strong basic anion exchange resin combined with a liquid/liquid partitioning, derivatized using MSTFA and confirmed, quantified by GC/MS/SIM with a internal standard, zearalane. The results were as follows : (1) all the estrogens were separated on the GC/MS chromatogram under the extraction method and the chromatographic conditions improved, the retention times of zearalane-TMS2, zearalanone-TMS2, zearalenone-TMS2, zeranol-TMS3, taleranol-TMS3, and $\alpha$-zearalenol-TMS3, $\beta$-zearalenol-TMS3, were 18.49, 19.44, 19.63, 19.71, 19.79 and 19.99, 20.08 minutes, respectively. (2) The calibration curves of residual zeranol, zearalenone and their metabolites showed constantly linear(r=0.99) in the range of 5~20 ng. The minimum detection concentration of residual zeranol, zearalenone and their metabolites was 1 ppb. (3) The total average recovery of residual zeranol, zearalenone and their metabolites from spiked beef was 60.2%(CV=29.7%) at the 1 ppb and 63.5%(CV=26.5) at the 2 ppb, 72.9%(CV=18.2%) at the 4 ppb. (4) The preservation method for 6 estrogens was improved for the fast running time(21 min) and MSTFA was utilized for derivatizing 6 estrogens for improvement of recovery, for good resolution, for characteristic mass spectra unlike Jose's method and Tina's method. The utilization of zearalane as internal standard showed good quantification result for zeranol, zearalenone, as well as their isomers and metabolites, in beef.

  • PDF

Separation of Fission Product Elements from Synthetic Dissolver Solutions of Spent Pressurized Water Reactor Fuels by $TBP/XAD-16/HNO_3$Extraction Chromatography ($TBP/XAD-16/HNO_3$추출 크로마토그래피에 의한 모의 사용후핵연료 용해용액 중 미량 핵분열생성물 원소의 분리)

  • Lee, Chang Heon;Choi, Kwang Soon;Kim, Jung Suk;Choi, Ke Chon;Jee, Kwang Yong;Kim, Won Ho
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.4
    • /
    • pp.304-311
    • /
    • 2001
  • A study has been carried out on the extraction chromatographic separation of fission products from spent pressurized water reactor (PWR) fuels for inductively coupled plasma atomic emission spectrometric analysis. Impregnation capacity of tri-n-butyl phosphate (TBP), which is well known as an extractant in the field of uranium separation from various nuclear grade materials, on Amberlite XAD polymeric macroporous support materials was measured. Amberlite XAD-16 of which the surface area is the highest was selected as a support material because its TBP impregnation capacity was the largest in Amberlite XADs. Sorption behaviour of this TBP impregnated resin was investigated for the fission product elements using acidic solutions simulated for dissolver solutions of spent PWR fuels. The parameters affecting the performance of the separation system were optimized. The fission product elements studied excluding Pd and Ru were quantitatively recovered with the precision of less than 3.1%.

  • PDF

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF