• Title/Summary/Keyword: extinguishing ability

Search Result 22, Processing Time 0.025 seconds

A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas (질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구)

  • Lim, Woo-Sub;Jung, Jong-Jin;Nam, Dong-gun;SaKong, Seong-Ho;Kim, Jong-Won;Choi, Kenu-Joo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.

A Study on the Fire Extinguishing Ability Rating of Load Streams (강화액 소화성능평가에 관한 연구)

  • Kwon, Seong-Pil;Kim, Hyeong-Gweon;Yoon, Hun-Ju;SaKong, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.159-162
    • /
    • 2008
  • A standard fire extinguishing tester, with which we could conduct the fire extinguishing ability rating of a water-based fire extinguishing agent such as water and loaded stream, has been developed in this work. It could help us enhancing the efficiency and reliability of the fire extinguishing test of loaded streams, and at last increasing the productivity of fire protection related firms. Furthermore, our country could take the lead in making a new standard for the fire extinguishing test of loaded streams. As a result, it is expected that loaded streams could be improved by using it. In addition the standard fire extinguishing tester could be made moderately in our industry, and supplied at home and worldwide.

  • PDF

A Study on Measuring of Fire Extinguishing Concentration for Organic Material Using Novec (노벡을 이용한 유기물의 소화농도 측정에 관한 연구)

  • Lim, Woo-Sub;SaKong, Seong-Ho;Jung, Jong-Jin;Nam, Dong-Gun;Choi, Kenu-Joo;An, Sang-Su;Kim, Jong-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.456-460
    • /
    • 2008
  • This study was on basic step to develop a good clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using Novec which is inert gas. In study used to Cup Burner Test its made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test. The finding is that a new clean agent, Novec has a very efficient extinguishing ability in a state of gas.

  • PDF

Comparison of Fire Extinguishing Effects for Water Mist Additives (미분무수 첨가제의 소화효과 비교)

  • Kim, Seung Il;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.23-28
    • /
    • 2013
  • In order to improve extinguishing performance of water mist, many studies of additives have been conducted. In this study, viscosity agent which has the ability to improve extinguishing performance by adhering to the surface on fire was used and fluorine-free surfactant was also added to water to enhance water's wetting ability. This study aimed to verify optimal concentration of extinguishing of additives according to fire source and extinguishing performance by comparison with pure water. In case of wood crib fire, the results show that flame suppression and extinguishing time of sodium alginate 0.4 wt.% are 3.4 times and 2.2 times shorter than those of pure water in 0.2 MPa respectively. It seems that large amount of water adhere to surface on fire, thus cooling effect on surface was enhanced. Also water consumption of sodium alginate 0.4wt.% is up to 65% lower than that of pure water. In case of heptane fire, extinguishing time of cocobetaine 0.1 wt.% is 9.7 times shorter than that of pure water in 0.2 MPa. It is thought that because cocobetaine can block oxygen and suppress oil mist by making emulsion film on fire surface due to a low surface tension. On the other hand, water consumption of cocobetaine 0.1 wt.% is 92% lower than that of pure water.

Characteristics of Fixed Aerosol Auto Fire-Extinguishing Systems (고체에어로졸 자동소화장치 특성)

  • Choi, Byoung-O;Hong, Chang-Su;Kwon, Seong-Won;Park, Sun-Gyu
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.277-282
    • /
    • 2008
  • We developed fixed aerosol auto fire-extinguishing systems which are different from fire suppression systems like powder extinguisher or halon extinguishing system, etc. Fixed aerosol auto fire-extinguishing substances which are including solid alkali salts generated by combustion of solid composition. It represents high fire suppression ability due to particle friendly auto fire-extinguishing systems for the reason of excluding toxic substances in it's composition.

  • PDF

EXPERIMENTAL STUDY ON PEAK CONCENTRATIONS OF HALON ALTERNATIVES AT ELEVATED TEMPERATURE

  • Ohtani, Hideo;Washimi, Akiko;Uehara, Yoichi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.550-557
    • /
    • 1997
  • Production of so-called Halon fire extinguishing agents has been prohibited since January 1994 because of their ozone depletion potential, To replace them, several hydrofluorocarbons and fluorocarbons have been developed and utilized. A number of studies on flame extinguishing concentrations and flammability peak concentrations of them have been done. Although there was enough information for practical purpose, more knowledge on fire extinguishing characteristics of them should be attained for efficient use of them. In this study, peak concentrations of methane/air mixtures with gaseous halogenated hydrocarbons were measured at elevated temperature, because the former studies were done at room temperature and temperature of a fire room can be higher than usual. Measurement was done at $200^{\circ}C$, because measuring system could not endure higher temperature. This study revealed that peak concentrations of halogenated hydrocarbons differed little at elevated temperature. The halogenated hydrocarbons have almost the same fire extinguishing ability as Halon 1301.

  • PDF

Field working and Fire extinguishing performance of an Indoor Fire-fighting Robot (실내화재진압로봇의 현장운용 및 소화성능평가)

  • Kwark, Ji-Hyun;Kim, Jong-Kwon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.163-167
    • /
    • 2008
  • Fire-fighters are struggling against heat and dense smoke by fire when it occurs at the basement or the inner place of a building. An indoor fire-fighting robot with well heat-resistance, great searching cameras and good extinguishing ability has been developed. It never suffocate, coming into the fire district and extinguishes fire directly. In this study, several experiment was conducted to evaluate field working ability of the fire-fighting robot. As a result, a series of passing obstacles, finding fire place and fire suppression by the remote controlling with image information appeared satisfactory.

  • PDF

THE DEVELOPMENT OF FOAMING AGENTS USING SLES & DH-109EX

  • Hu Rui;Kim, Jeong-Hun;Kim, Min-Kyn;Kang, Young-Goo;Kim, Hong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.582-589
    • /
    • 1997
  • Experiments were conducted to develop foaming agents by using SLES and DH-l09EX as raw material. PG (Propylene glycol) and BC (Butyl cellusolve) were adopted as subsidiary material. The undiluted foam solution was produced with these materials. This solution determined the expansion ratio, viscosity, drainage time and extinguishing ability of the final product. The results indicate that the expansion ratio is over 16 and drainage time is over one minute. The extinguishing ability for SLES system was succeeded in the unit of B-0.5.

  • PDF

Fire Extinguishing Ability of Binary Gaseous Extinguishing Agents Evaluated by Cup Burner and Numerical Studies (이성분계 가스계소화약제 소화성능의 컵버너실험 및 이론적 고찰)

  • Kwon, Kyung-Ok;Won, Dong-Bin;Choi, Keun-Joo;Kim, Jong-Won;Shin, Dong-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.7-12
    • /
    • 2007
  • The search for a new fire-extinguishing agent with all the desirable properties of halon 1301 has not been successful. To study binary gaseous extinguishing agents instead, one has to determine the extinguishing concentrations for several compositions of a given chemical in an inert gas. This process is expensive and time consuming. The fire suppression efficiencies of gas mixtures of HFC 125 and HFC 227ea with nitrogen as total flooding agents were studied by cup burner method. It was shown that addition of small amounts of those extinguishants to nitrogen can enhance the suppression effectiveness of the inert gas. As expected, the degree of synergism was highest at low concentrations of the chemical. For each binary system, extinguishing concentrations of the pure compounds and one binary data were used to predict the extinguishing concentrations for the entire range of binary composition. The predicted values were very close to experimental data.

  • PDF

A Study of Fire Extinguishment Characteristic for the Real Scale Deap-Seated Fire (실규모 심부화재 소화특성에 관한 연구)

  • Kim, Nam-Kyun;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.13-19
    • /
    • 2015
  • Real scale fire tests was carried out for extinguishing performance evaluation of the wetting agent. The experiment was conducted in accordance with a Class A fire extinguishing test methods specified in the 'Type Approval of the Manual System Fire Extinguisher and Technical Standards of Test'. In addition, the subjects of this experiment were the wood flour and rice husk. Fire-fighting water, the three kinds of wetting agents used in the country and this study was used, was undertaken to determine a clear discrimination of the water and wetting agent. In the experimental results, it was confirmed that the internal temperature is maintained long time in the case of water. The internal temperature were rapidly lowered in the experiment of wetting agents. Therefore, the discrimination of extinguishing ability was confirmed by the temperature distribution in accordance with time. Based on the results of this experiment, this study is expected to be used as a underlying material on presenting a method of optimized performance evaluation of wetting extinguishing agent.