• Title/Summary/Keyword: external magnetic field

Search Result 448, Processing Time 0.049 seconds

Neural Network based Three Axis Satellite Attitude Control using only Magnetic Torquers

  • Sivaprakash, N.;Shanmugam, J.;Natarajan, P.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1641-1644
    • /
    • 2005
  • Magnetic actuation utilizes the mechanic torque that is the result of interaction of the current in a coil with an external magnetic field. A main obstacle is, however, that torques can only be produced perpendicular to the magnetic field. In addition, there is uncertainty in the Earth magnetic field models due to the complicated dynamic nature of the field. Also, the magnetic hardware and the spacecraft can interact, causing both to behave in undesirable ways. This actuation principle has been a topic of research since earliest satellites were launched. Earlier magnetic control has been applied for nutation damping for gravity gradient stabilized satellites, and for velocity decrease for satellites without appendages. The three axes of a micro-satellite can be stabilized by using an electromagnetic actuator which is rigidly mounted on the structure of the satellite. The actuator consists of three mutually-orthogonal air-cored coils on the skin of the satellite. The coils are excited so that the orbital frame magnetic field and body frame magnetic field coincides i.e. to make the Euler angles to zero. This can be done using a Neural Network controller trained by PD controller data and driven by the difference between the orbital and body frame magnetic fields.

  • PDF

A Study of the Characteristics on the Vacuum Interrupter with Axial Magnetic Field Type using 3 Dimension Finite Element Analysis (3차원 유한요소해석을 이용한 종자게형 진공 인터럽터의 특성고찰)

  • 하덕용;강형부
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.5
    • /
    • pp.460-467
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density on the vacuum interrupter with axial magnetic field type using 3 dimension finite element analysis. An axial magnetic field parallel to the current flow in the arc column can improve the current breaking capacity of vacuum interrupter by affecting the arc mode. The axial magnetic flux density on the contact electrode surface is analyzed by inputting external current as a function of the transient time for sine half wave. And it also is analyzed within the gap distance of the contact electrode. The peak value of current but is decreased with the descending current on the contact electrode surface and within the gap distance of the contact electrode. The residual magnetic field is generated on the contact electrode surface and within the gap distance in the instant of zero current, which is due to the influence of eddy currents. The phase shift due to eddy currents, defined as time difference between the maximum value of current and axial magnetic field, is about 1ms in the center point of gap distance.

Detection of Magnetic Nanoparticles in Tissue Using Magneto-Motive DP-OCT

  • Oh, Jung-Hwan;Lee, Ho;Kim, Jee-Hyun
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • We demonstrate the capability of differential-phase optical coherence tomography (DP-OCT) to detect superparamagnetic iron oxide (SPIO) nanoparticles taken up by liver parenchymeal macrophages (Kupffer cells). We apply an external time-varying high-intensity focused magnetic field. Our experiments demonstrate a novel diagnostic modality to detect macrophages that have taken up SPIO nanoparticles. Magnetic force acting on the nanoparticles was varied by applying a sinusoidal current to a solenoid containing a conical iron core that substantially increased and focused the magnetic field strength ($B_{max}$ = 2 Tesla). $ApoE^{-/-}$ mice were sacrificed 2 days post intravenous injections of different SPIO doses (1.0, and 0.1 mmol Fe/kg body weight). Livers of $ApoE^{-/-}$ mice with and without injection of SPIO nanoparticles were investigated using DP-OCT, which detects tissue movement with nanometer resolution. Frequency response of iron-laden liver movement was twice the stimulus frequency. Movement was not observed in livers of control mice. Results of our experiments indicate DP-OCT is a candidate methodology to detect tissue based macrophages containing SPIO nanoparticles excited by an external focused magnetic field.

Optimal Design of Magnetic Suspension Using Design of Experiment (실험계획법을 이용한 Magnetic suspension의 최적설계)

  • Jung, Jae-Woo;Kim, Sung-Ill;Ha, Seung-Hyoung;Hong, Jung-Pyo;Lee, Ju-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.769-770
    • /
    • 2006
  • This paper proposes the design method of a magnetic suspension that can control external vibration caused by low frequencies on the external vibrations by low frequencies. The magnetic suspension with individual controls is able to compensate the vibrations unlike a mechanical suspension. In the magnetic suspension, two characteristics are required. Firstly, magnetic motive force(MMF) by armature winding must be increased linearly. Secondly, identical magnitude of output force should be produced as direction of MMF. In this paper, axis-symmetric finite element analysis is used for magnetic field analysis. In order to optimize magnetic suspension, response surface methodology combined with experimental design is applied to investigate the characteristics and optimize the magnetic suspension for vibration -free table.

  • PDF

Effect of Vibrational Amplitude on Friction and Wear Properties of Magnetorheological Elastomer (진폭에 따른 자기유변탄성체의 마찰 특성 연구)

  • Lian, Chenglong;Lee, Kwang-Hee;Lee, Chul-Hee
    • Tribology and Lubricants
    • /
    • v.32 no.2
    • /
    • pp.39-43
    • /
    • 2016
  • Magnetorheological elastomers (MREs) are a type of “smart” material, and their properties can be controlled rapidly and reversibly under the influence of an external stimulus. The application of an external magnetic field can change the shear modulus, hardness, and friction coefficient of MREs. The friction can cause vibration; moreover, the vibration can affect friction. The change of friction depends on the relative motion, normal force, roughness of the rubbing surfaces, material type, temperature, lubrication, relative humidity, and vibration condition. As MREs are a type of “smart material,” their friction coefficient can be reduced by applying an external magnetic field—the applications of this feature in engineering have been widely studied. However, the friction properties of MREs under vibration have not been tested to date. In this study, MRE samples and a reciprocating friction tester were fabricated. The friction coefficient was measured to evaluate the friction properties under various vibration conditions; subsequently, the wear depth and wear surface profile of the MRE were observed in order to evaluate the wear properties. The results show that the friction coefficient of the MREs decreased when a magnetic field was applied. Moreover, the friction coefficient decreased when the vibrational amplitudes increased. The wear depth of the MRE also decreased as the vibrational amplitudes increased.

Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field (고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설)

  • Lim, Hyoung-Woo;Lee, Dong-Min;Yun, Ki-Hyun;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF

Fault Current Limiting Characteristic of Flux-Lock Type HTSC Fault Current Limiter (자속구속형 고온초전도 전류제한기 사고전류제한 특성)

  • Lim, Sung-Hun;Choi, Myung-Ho;Park, Bok-Kee;Song, Jee-Joo;Park, Dae-Hee;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.105-108
    • /
    • 2002
  • In this paper, we investigated the fault current limiting characteristic of flux-lock type High-Tc superconducting fault current limiter(HTSC-FCL), which is comprised of a flux-lock reactor and an external magnetic field coil covering the HTSC element In this HTSC-FCL, the initial limiting current level can be controlled by adjusting the inductance of the each coil. Furthermore, the fault current limiting characteristics of HTSC-FCL can be improved by applying 'the external magnetic field into the HTSC element We performed the computer simulation by numerical analysis about the flux-lock type HTSC-FCL and compared the results of experiment with simulation ones. We can obtain the same results from both the computer simulation and the experiment except for the time immediately after fault occurs.

  • PDF

Development of Auto-Tuning Geomagnetic Compass (자동 자기 왜곡보정 방위센서 개발)

  • Kim, Sang-Cheol;Lee, Yong-Beom;Han, Kil-Su;Im, Dong-Hyeok;Choi, Hong-Gi;Park, Woo-Pung;Lee, Woon-Yong
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.58-62
    • /
    • 2008
  • The need for position information in agriculture is gradually increasing for precise control farm vehicle and effective manage farm land. Though geomagnetic sensor has a lot of merits in estimating heading angle of vehicle because of low costs and sensing ability of magnetic north, it is easy that sensor outputs are distorted in electro magnetic field environment. This study was conducted to develop geomagnetic compass which could be available in measuring relative position from reference point correcting output distorted by external electro magnetic field in a small scale field. Magnetic inducing sensor (PNI's Vector2X) which wound enamel coated copper coil on ferrite core in order to measure and correct earth magnetic field. Magnetic azimuth was corrected using the algorithm which estimated amount of magnetic distortion from the difference between each outputs of magnetic sensors that located on the cross shaped base. Developed auto-tuning magnetic sensor was showed less then 5% as bearing accuracy in the strong magnetic field.

Critical current characteristic of various 2G HTS multi-stacked tapes depending on the low external magnetic field

  • Kim, J.;Lee, W.S.;Jin, H.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • 2G HTS tapes are widely used for various electric machines. In addition, stacked or parallel connected HTS tapes are essentially used to raise transport current level for large capacity electric machines. Therefore, critical current characteristic of stacked tapes need to be studied. Recently developed 2G HTS tapes are fabricated with various defects doping so that tapes possess pinning center to improve the critical current characteristic. During this process, the critical current is determined minimum value in not perpendicular magnetic field but a specific magnetic field angle according to the reported research. However, the effects of magnetic field angle to critical current of multi-stacked 2G HTS tapes have not been examined. In this paper, field coil which is a race-track coil wound by using an HTS tape with iron-core was fabricated to apply angle adjustable magnetic field to the 2G HTS tape samples. We measured critical current of single and multi-stacked two tapes that have different characteristic depending on various magnetic field angle and magnitude in liquid nitrogen environment. Furthermore, results of single and multi-stacked tapes were compared and analyzed.