• Title/Summary/Keyword: external heat

Search Result 864, Processing Time 0.024 seconds

Enhancement of Downward-Facing Saturated Boiling Heat Transfer by the Cold Spray Technique

  • Sohag, Faruk A.;Beck, Faith R.;Mohanta, Lokanath;Cheung, Fan-Bill;Segall, Albert E.;Eden, Timothy J.;Potter, John K.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.124-133
    • /
    • 2017
  • In-vessel retention by passive external reactor vessel cooling under severe accident conditions is a viable approach for retention of radioactive core melt within the reactor vessel. In this study, a new and versatile coating technique known as "cold spray" that can readily be applied to operating and advanced reactors was developed to form a microporous coating on the outer surface of a simulated reactor lower head. Quenching experiments were performed under simulated in-vessel retention by passive external reactor vessel cooling conditions using test vessels with and without cold spray coatings. Quantitative measurements show that for all angular locations on the vessel outer surface, the local critical heat flux (CHF) values for the coated vessel were consistently higher than the corresponding CHF values for the bare vessel. However, it was also observed for both coated and uncoated surfaces that the local rate of boiling and local CHF limit vary appreciably along the outer surface of the test vessel. Nonetheless, results of this intriguing study clearly show that the use of cold spray coatings could enhance the local CHF limit for downward-facing boiling by > 88%.

A Study on the Fire Hazards of Puzzle Mats in Group Day Care Home (놀이방 퍼즐매트의 화재위험성에 관한 연구)

  • Park, Hyung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.73-78
    • /
    • 2008
  • The fire hazards and combustion heat of puzzle mats in group day care home were analysed using variable external irradiation level. The fire hazards such as ignition time, ignition temperature, mass loss rate, and flame temperature profile were measured. Incident heat fluxes of $15kW/m^2$, $20kW/m^2$, $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $75kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminium foil. Each sample was nominally 20mm thick and 100mm square. Five samples of puzzle mat were tested in the study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. As results, Type E of FR-grade showed the best characteristics in safety of the early fire from ignition time, critical heat flux, and ignition and flame temperature data of this study. All specimen of G-grade(Type A, B and C), however, showed the weak in safety of fire.

Thermal Characteristics and Cooling Experiments and Analysis of Finite Elements in the Discharge of Lithium-Ion Batteries (리튬이온 배터리 방전 시 발열 특성 및 냉각 실험과 유한요소 해석)

  • Seokil Kim;Shin You Kang
    • Journal of Industrial Technology
    • /
    • v.43 no.1
    • /
    • pp.15-23
    • /
    • 2023
  • Lithium-ion batteries are predominantly employed in electric vehicles and energy storage devices, offering the advantage of high energy density. However, they are susceptible to efficiency degradation when operated at high temperatures due to their sensitivity to the external environment. In this study, we conducted experiments using an indirect cooling method to prevent thermal runaway and explosions in lithium-ion batteries. The results were validated by comparing them with heat transfer simulations conducted through a commercial finite element analysis program. The experiments included single-cell exothermic tests and cooling experiments on a battery pack with 10 cells connected in series, utilizing 21700 lithium-ion batteries. To block external temperature influences, the experimental environment featured an extrusion method insulation in the environmental chamber. The cooling system, suitable for indirect cooling, was constructed with copper tubes and pins. The heat transfer analysis began by presenting a single-cell heating model using commercial software, which was then employed to analyze the heating and cooling of the battery pack.

Characterization of a Thermal Interface Material with Heat Spreader (전자부품의 방열방향에 따른 접촉열전도 특성)

  • Kim, Jung-Kyun;Nakayama, Wataru;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.91-98
    • /
    • 2010
  • The increasing of power and processing speed and miniaturization of central processor unit (CPU) used in electronics equipment requires better performing thermal management systems. A typical thermal management package consists of thermal interfaces, heat dissipaters, and external cooling systems. There have been a number of experimental techniques and procedures for estimating thermal conductivity of thin, compressible thermal interface material (TIM). The TIM performance is affected by many factors and thus TIM should be evaluated under specified application conditions. In compact packaging of electronic equipment the chip is interfaced with a thin heat spreader. As the package is made thinner, the coupling between heat flow through TIM and that in the heat spreader becomes stronger. Thus, a TIM characterization system for considering the heat spreader effect is proposed and demonstrated in detail in this paper. The TIM test apparatus developed based on ASTM D-5470 standard for thermal interface resistance measurement of high performance TIM, including the precise measurement of changes in in-situ materials thickness. Thermal impedances are measured and compared for different directions of heat dissipation. The measurement of the TIM under the practical conditions can thus be used as the thermal criteria for the TIM selection.

Partial Insulation and Heating Tubes Configuration of Shell and Tube Steam Reformer at Medium Temperature (중온형 원통다관형 수증기 개질기의 부분단열 및 반경방향 분배 구조의 영향)

  • PARK, DAIN;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.618-626
    • /
    • 2017
  • Conventional high temperature reformers are not suitable for hybrid fuel cell systems that use waste heat as a heat source. So, development of a low temperature type reformer is needed. However, the analysis was conducted in two ways to increase the thermal efficiency, because of low reforming rate due to the low heat source. First, it is a way to ger thermal gain from the outside through partial insulation. In the case of one heat source tube and several heat source tubes, we analyzed the effect of partial heat insulation in some cases. Second, we found the most efficient arrangement of the heat source tubes by changing the location of the heat source tubes. The interpretation was carred out using the COMSOL Mutiphysics program.

Electronics Cooling Using the Porous Metallic Materials

  • Lucaci, Mariana;Orban, Radu L.;Lungu, Magdalena;Enescu, Elena;Gavriliu, Stefania
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.315-316
    • /
    • 2006
  • The paper presents some results regarding the obtaining of some copper heat pipes with a porous copper internal layer for electronic components cooling. The heat pipes were realized by sintering of spherical copper powders of $90{\div}125\;{\mu}m$ size directly on the internal side of a copper pipe of 18 mm in diameter. The obtained pipes were then brazed in order to obtain a heat pipe of 0.5 m in length. After that, the heat pipe was sealed and filled with a small quantity of distilled water as working fluid. To establish the total heat transport coefficient and the thermal flow transferred at the evaporator, some external devices were realized to allow the heating of the evaporator and the cooling of the condenser. Water heat pipes are explored in the intermediate temperature range of 303 up to 500 K. Test data are reported for copper water heat pipe, which was tested under different orientations. The obtained results show that the water heat pipe has a good thermal transfer performance in the temperatures range between 345 and 463 K.

  • PDF

A literatual studies on the chi-jil(痔疾). (肛門病 中 痔의 範疇와 原因 症狀 및 治療에 對한 文獻的 考察)

  • Lee, Sang-uk;Ko, Woo-shin
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.12 no.1
    • /
    • pp.313-337
    • /
    • 1999
  • In oriental medicine, 'chi(痔)' is 'the prolapsed nodule' in 'Ku-gyu(九竅)', but in this paper, I will write about prolapsed nodule only in anus or around it, chi-jil(痔疾), it called hemorrhoid in western medicine. So in the literatual studies on chi(痔) in anus or around it, the results are as follows. 1. The etiology and pathogenesis of ch.i-jil(痔疾) is wind, wetness, dryness, and heat caused by inrregular diet habit, severe drinking and sexual action, deficiency of ki(氣) and hyeol(血). 2. Characteristic symptoms of chi-jil(痔疾) is the prolapsed nodule in the anus or around it, and general symptoms are hematochezia, pain, hernia, swelling, abcess, and mucosal secretion. 3. Chi-jil(痔疾) is classified eight types by characteristic symptom, shape, etiology and pathogenesis. They are mac-chi(脈痔), jang-chi(腸痔), ki-chi(氣痔), hyeol-chi(血痔), joo-chi(酒痔), mo-chi(牡痔), bin-chi(牡痔), and loo-chi(屢痔)(or young-chi(영痔), choong-chi(蟲痔)). Additionally, they are divided into two parts, internal and external chi-jil(痔疾), as likely as classification of internal and external hemorrhoid in western medicine. 4. Treatment of chi-jil(痔疾) is two methods, internal treatment and external treatment. Internal treatment is per os herb-pharmacotheraphy, external treatment is surgical or the other external pharmacotheraphy. There are several external treatment, these are fumigation-theraphy(熏痔法). irrigation-theraphy(洗痔法), paint-theraphy(塗痔法). withering-theraphy(枯痔法), bending-therphy(結紮法) and incisal -theraphy(切開法).

  • PDF

An Architectural Study on the Improvement of Energy Efficiency of Public Institution - Focused on Public Office Buildings Remodeling of Passive Design Elements - (공공기관 에너지 효율등급 향상을 위한 적용 설계요소에 관한 연구 - 공공청사 리모델링시 패시브 디자인요소를 중심으로 -)

  • Cho, Jung-Chul;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.114-120
    • /
    • 2012
  • There are lots of buildings which were built before the Legislation on building energy rating system. Remodeling of the buildings would be required for an improvement of the building energy rating system was enforced by the government. In the Passive Building Design, Elements which will be used for the remodeling are Insulation, Window, External venetian blind, Heat exchanger. The Purpose of this study is to indicate a Method for the improvement of Energy saving by an analysis of Construction Cost, Cost Evaluation, Energy performance Efficiency in applied design elements. In this study, the remodeling of existing public buildings to improve energy efficiency rating was applied to extract the elements of design-specific energy performance, efficiency, and the application of the designs that has been analyzed. The results were as follows: applying the design-specific cost-effective investment that represents the economy (investment efficiency/%) surveyed the average insulation(7.0%), triple glazed windows(10.1%), double glazed windows(12.1%), external shading(24.5%), and Heat(77.2%) were analyzed in order to be more efficient. Analysis of the basis of information on the existing public buildings to improve energy efficiency rating for the remodeling depending on driving conditions at a degree of individual difference. The main effect, however, depending on economic investment, design elements, heat exchangers, external awning, double glazed windows, triple glazed windows, insulation, is recommended as review of the order shall be determined.

  • PDF

A Study on the Herb Medicine of Toothache (치통(齒痛)의 처방(處方)에 대한 문헌고찰(文獻考察))

  • Park, Young-Ho;Yu, Mi-Kyung;Kim, Dae-Soo;Kang, Moon-Yeo;Lee, Myung-Jin;Lee, Jun-Hun;Choi, Jung-Hwa
    • Herbal Formula Science
    • /
    • v.14 no.1
    • /
    • pp.52-73
    • /
    • 2006
  • Objective & Methods: Toothache is occurred frequently in daily life. Nevertheless, medical treatment of the toothache is almost dependent on western cure. So we chose the oriental medicine textbook that were dealing with the internal herb medicine and external treatment. we got this result. Result were as follows : 1. The internal medication of toothache was the most used 15times Chungwesan(淸胃散) and 8times Palmihwan(八味丸). 2. Chungwesan (淸胃散) was used to remove the stomach heat. the intestin stomach heat and the stomach blood heat. etc. 3. The pill and powder form in external treatment was much used. 4. The most many used herb were Asari herba cum Radice(細辛), Cimicifugae Rhizoma( 升麻) and Angelicae dahurcae Radix(白芷), etc. 5. The most herb used for external treatment were the spicy warm and the spicy hot medication.

  • PDF

Characteristics for Fluid Flow in Circulating Fluidized Heat Exchanger (순환유동층 열교환기의 유동특성)

  • 이병창;안수환;김원철;배명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1291-1297
    • /
    • 2001
  • The commercial viability of heat exchanger is mainly dependent on their long-term fouling characteristics because the feeling increases the pressure loss and degrades the thermal performance of a heat exchanger An experimental study was performed to investigate the characteristics of fluid flow in a fluidized bed heat exchanger with circulating various solid particles. The present work showed that the drag force coefficients of particles in the internal flow were higher than in the external flow, in addition, they were lower with the shapes of particles being closer to the spherical geometries.

  • PDF