• Title/Summary/Keyword: external evaluation

Search Result 1,403, Processing Time 0.025 seconds

A Basic Study on Evaluation Method and Performance of Membrane Waterproofing Layer (멤브레인 방수층 성능 및 평가방법에 관한 기초적 연구)

  • Oh, Mi-Hyun;Kwon, Shi-Won;Kang, Hyo-Jin;Jung, Hee-Won;Choi, In-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.17-21
    • /
    • 2003
  • This study is mainly acceptive for physical material performance than waterproofing layer performance on the external condition after construction. The reason are legalized only for material performance quality standard even though it is existed waterproofing materials for membrane. In actuality, waterproofing layer are greatly occurred in performance a decreased developing essential element that are human footprints as a result physical perimeter environment after construction and on the construction. As the result, this present paper purpose for evaluation and performance of the membrane waterproofing layer on the construction.

  • PDF

Current Status and Prospects for the Quality Evaluation of Medicinal Plants (약용식물의 품질평가 현황과 전망)

  • 김관수;류수노
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47
    • /
    • pp.186-199
    • /
    • 2002
  • This is a brief review and discussion for present status and prospects of quality evaluation in medicinal plants as oriental medicine materials (OMM). Quality in medicinal plants could be defined as the combination of origin, external appearance, effectiveness and safety, and be evaluated by plant taxonomic, morphological, physiochemical and biological methods. For high-quality improvement and standardization of OMM, medicinal plants should be produced through using proper species or good variety and standard cultivation method in suitable cultivation area. Standardizing of quality means to meet with minimum qualifying criteria of OMM in the market while improving of quality to be over standard quality of medicinal piano in production. For making new high quality and standardized products, we need to keep standard field plants, standard OMM, standard plant specimen, and standard compounds. Researchers and administration have to study and propose the quality factors and their evaluating techniques and criteria, so high-quality and standardized produce of medicinal plane could be produced and distributed under the control of the relevant regulations, and would be contributed to increasing of national health.

A Basic Study on Evaluation Method and Performance of Membrane Waterproofing Layer (멤브레인 방수층 성능 및 평가방법에 관한 기초적 연구)

  • 오미현;권시원;강효진;정희원;최인성;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.17-21
    • /
    • 2003
  • This study is mainly acceptive for physical material performance than waterproofing layer performance on the external condition after construction. The reason are legalized only for material performance duality standard even though it is existed waterproofing materials for membrane. In actuality, waterproofing layer are greatly occurred in performance a decreased developing essential element that are human footprints as a result physical perimeter environment after construction and on the construction. As the result, this present paper purpose for evaluation and performance of the membrane waterproofing layer on the construction.

  • PDF

Performance Evaluation of Window Ventilation System for Reducing Indoor particulate matter (실내 미세먼지 저감을 위한 창호형 환기시스템 성능평가)

  • Yang, Young Kwon;Park, Jin Chul
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2019
  • Indoor particulate matter(PM) is a carcinogen and needs to be removed and managed. It is generally reduced and removed through ventilation and filtration. Owing to the recent occurrence of high-concentration fine dust and yellow dust in the atmosphere, however, it is difficult to expect the purification of indoor air through the simple introduction of the outside air. For residential buildings, in particular, they are highly dependent on natural ventilation but the lack of natural ventilation is worsening because concerns over the inflow of external pollutants are increasing. Therefore, this study designed and manufactured a window ventilation system that does not require a duct to improve the maintenance and management problems of general ventilation system, and constructed indoor PM concentration change data through performance evaluation.

Establishment of strain measurement system for evaluation of strain effect in HTS tapes under magnetic field

  • Dedicatoria, Marlon J.;Shin, Hyung-Seop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.4
    • /
    • pp.14-17
    • /
    • 2011
  • The evaluation of the electromechanical properties of HTS CC tapes is one of the foremost procedures to be done to ensure the applicability of superconducting wires to electric devices. A precise measurement of the stress and strain is important in deriving the mechanical properties under operating environment. Up to now, there is no standard test method yet for the electromechanical property evaluation of HTS tapes under self field and external magnetic field although there are already reports on the different devices used to evaluate these properties. Strain can be measured by adopting a strain gauge or a high resolution double extensometer. In this study, strain effect on $I_c$ in HTS CC tapes under magnetic fields was evaluated. Comparison of advantages and setback of strain measuring devices were discussed. In addition, a dual strain measurement system using both the SG and extensometer may be practical to lessen the burden in case one of the measuring devices does not work well.

Evaluation of the Joint Design in Composite Truss Bridges (복부 트러스 복합교량 접합구조의 실험적 연구)

  • Shim, Chang-Su;Park, Jae-Sik;Kim, Kwang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.325-328
    • /
    • 2006
  • Joint structures of composite truss bridges can have the same details for the connection between diagonal members and upper concrete slab as the connection between diagonal members and lower concrete slab. Adequate connection details should be decided according to design codes, constructibility, and economical evaluation. It is necessary to clarify the design check items and load transferring mechanism because combined external loads on composite truss bridges are concentrated at the joints. Joints with gusset plates and stud connectors are applied and complicated joint details may arise some problems in construction. This paper deals with experimental evaluation of the joints in composite truss bridges and proper design provisions were investigated to enhance the details. Push-out test specimens with group studs were fabricated and the effects of grouping and bent studs were studied.

  • PDF

An Evaluation of the Effect of Internal Thinning Defect on the Failure Pressure of Elbow (곡관의 손상압력에 미치는 내부 감육결함의 영향 평가)

  • Kim, Jin-Weon;Kim, Tae-Soon;Park, Chi-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.28-34
    • /
    • 2003
  • In the present study, three-dimensional finite element analysis was performed to investigate the effects of internal wall thinning defect on the failure pressure of elbow in the piping system and to develop the failure pressure evaluation model. From the results of finite element analysis, the failure pressure was derived by employing local stress criteria, and the effects of thinning location, bend radius, and defect geometry on the failure pressure of internally wall thinned elbow were investigated. Also, based on these investigations and previous model developed to estimate the failure pressure of elbow with an external pitting defect, the failure pressure evaluation model to be applicable to the elbow containing an internal thinning defect was proposed and compared with the results of finite element analysis. The failure pressure calculated by the model agreed well with the results of finite element analysis.

A Study on the Evaluation of Durability of Fiber Reinforced Concrete According to the Change of External Conditions (외부조건의 변화에 따른 섬유보강콘크리트의 내구성능 정가에 관한 연구)

  • Kim, Nam-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.97-104
    • /
    • 2008
  • This study was intended to evaluate the permeable performance through a change of reinforcing materials, curing condition, durability evaluation and permeability test, and to select the reinforcing material which could reduce the durability and water tightness from it, as the study for considering how the change of the outside's environment factors that the concrete structure actually contacted with impacted the concrete's durability especially the permeability by referring to such the background of the study. Accordingly, it was judged that evaluating the permeability by considering the severe environment condition where the concrete structure was placed in was more reasonable than measuring the existing permeability coefficient conducted in the sound state for the permeability evaluation of actually-used concrete structure. In this study, it also could be known that the specimen of hybrid fiber reinforced concrete which mixed the long and short steel fiber was the most effective for water tightness enhancement in severe environmental conditions.

Tire and Vehicle Pull I-Experimental Results (타이어와 차량 쏠림 I-시험결과)

  • 이정환;이주완
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.194-201
    • /
    • 2000
  • It is called vehicle pull when a vehicle drifts in the lateral direction under the straight-ahead motion with no steering or external input. Recently vehicle pull draws attention as one of the critical evaluation items from the customers on the vehicle quality. It is generally recognized that the vehicle pull is complex phenomena due to internal and external factors. In this paper the relations between vehicle pull and ire were investigated through close survey on the road test results from the final inspection of car manufactures. Through this investigation the factors are identified which play an important role in causing vehicle pull problem.

  • PDF

An Investigation of Thermal Margin for External Reactor Vessel Cooling(ERVC) in Large Advanced Light Water Reactors(ALWR)

  • Park, Jong-Woon;Jerng, Dong-Wook
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.473-478
    • /
    • 1997
  • A severe accident management strategy, in-vessel retention corium through external reactor vessel cooling(ERVC) is being studied worldwide as a means to prevent reactor vessel failure following a core melt accident. An evaluation of feasibility of this ERVC for a large Advanced Light Water Reactor (ALWR) is presented. To account for the coolability of corium and metal in the reactor vessel, a thermal analysis is performed using an existing method. Results show that the peak heat flux along the inner surface of the reactor vessel lower head has a relatively smaller margin than a small capacity reactor such as AP600 in regards with the critical heat flux attainable at the outer surface of the reactor vessel lower head.

  • PDF