• Title/Summary/Keyword: external dose

Search Result 474, Processing Time 0.036 seconds

[ 137Cs] and 40K Activities of Foodstuffs Consumed in Jeju (제주지역에서 소비되는 식품 중 137Cs과 40K 방사능 농도)

  • Kang, Tae-Woo;Hong, Kyung-Ae;Park, Won-Pyo;U., Zang-Kual
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.1
    • /
    • pp.52-58
    • /
    • 2004
  • This work was conducted to provide the reference data of radioactivity in the foodstuffs at a radiological emergency situation in Jeju Island The sampled foodstuffs were agricultural (31), livestock (6), marine (12) and forest products (4), and processed foods (3) consumed by Jeju Islanders. $^{137}Cs$ and $^{40}K$ activities were determined by HPGe r-ray spectromety. The activity ranges of $^{137}Cs$ was ${\sim}650\;mBq/kg$ fresh in the agricultural products, ${\sim}131\;mBq/kg$. fresh in the livestock, ${\sim}834\;mBq/kg$ fresh in the forest, ${\sim}253\;mBq/kg$ fresh in the marine and $32.0{\sim}483\;mBq/kg$. fresh in the processed foods (tea). In case of $^{40}K$ the activity was $16.6{\sim}542\;Bq/kg$. fresh in the agricultural products, $39.1{\sim}294\;Bq/kg$ fresh in the livestock, $85.5{\sim}116\;Bq/kg$ fresh in the forest, $50.1{\sim}657\;Bq/kg$ fresh in the marine, and $33.6{\sim}1,065\;Bq/kg$ fresh in the processed foods (tea). The highest activity of $^{137}Cs$, 834mBq/kg fresh was observed in oak mushroom and $^{40}K$ 1,065 Bq/kg fresh in coffee. Annual effective doses of $^{137}Cs$ and $^{40}K$ by intake of foodstuffs per capita were the following order; agricultural products (66,543 nSv) > livestock products (19,311 nSv) > processed foods (6,648 nSv) > marine products (6,579 nSv) > forest products (860 nSv). Therefore, total annual effective dose was summed 99,941 nSv which is quite low level comparing to the annual effective dose by external exposure, 2,400,000 nSv. The data obtained in this study can be useful for monitoring whether the foodstuffs are contaminated or not at an emergency radiation accident, and showed that the foodstuffs consumed in Jeju are safe in terms of annual effective dose of $^{137}Cs$ and $^{40}K$

Interstitial Vaginal Needle Implantation in Gynecological Tumors : Design and Construction of Applicator (부인과암에서 조직내 삽입 방사선치료 - Applicator의 고안 및 제작-)

  • Kang, Seung-Hee;Chun, Mi-Son;Kang, Hae-Jin;Jung, Chil;Son, Jeong-Hyae
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.167-175
    • /
    • 1998
  • Purpose : It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or sing1e plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Materials and Methods : Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases) or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a sing1e plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to improve tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material$(Provil^{(R)})$. The applicators were customized individually according to the tumor size and its location Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Results : Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant procedure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal isodose coverage. We found an accurate needle arrangement and ideal dose distribution through the CT scan that was obtained in 3 cases after needle implant. Three patients with primary cervical and vaginal cancers were controlled locally at final follow up. But all recurrent cases failed to do so. Conclusion : The authors introduce inexpensive, simple interstitial vaginal templates which were self-designed and constructed using materials available from commercial vendors such as acrylanide and dental mold material $(Provil^{(R)})$.

  • PDF

Comparison of the Result of Radiation Alone and Radiation with Daily Low Dose Cisplatin in Management of Locally Advanced Cervical Cancer (국소적으로 진행된 자궁경부암에서 방사선 단독치료와 방사선 및 저용량 Cisplatin 항암화학요법 병용치료의 비교)

  • Kim Hun Jung;Kim Woo Chul;Lee Mee Jo;Kim Chul Su;Song Eun Seop;Loh John J K.
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.200-207
    • /
    • 2004
  • Purpose: An analysis was to compare the results of radiation alone with those of radiation with dally low dose cisplatin as a radiation sensitizer in locally advanced cervical cancer. Materials and Methods: A retrospective analysis of 59 patients diagnosed with locally advanced uterine cervix cancer between December 1996 and March 2001 was peformed. Thirty one patients received radiation alone and 28 patients received dally low dose cisplatin, as a radiation sensitizer, and radiation therapy. The median follow-up period was 34 months, ranging from 2.5 to 73 months. The radiation therapy consisted of 4500 cGy external beam irradiation to the whole pelvis (midline block after 3060 cGy), a 900$\~$l,000 cGy boost to the involved parametrium and high dose-rate intracavitary brachytherapy (a total dose of 3,000$\~$3,500 cGy/500 cGy per fraction to point A, twice per week). In the chemoradiation group, 10 mg of daily intravenous cisplatin was given daily from the 1st day of radiation therapy to the 20th day of radiation therapy. According to the FIGO classification, the patients were subdivided into 51 (86.4$\%$) and 8 (13.6$\%$) stages IIB and stage IIIB, respectively. Results: The overall 5 year survival rate was 65.65$\%$ and according to treatment modality were 56.75$\%$ and 73.42$\%$ in the radiation alone and chemoradiation groups, respectively (p=0.180). The 5 year disease-free survival rates were 49.39$\%$ and 63.34$\%$ in the radiation alone and chemoradiatoin groups, respectively (p=0.053), The 5 year locoregional control rates were 52.34$\%$ and 73.58$\%$ in the radiation alone and chemoradiation groups, respectively (p=0.013). The 5 year distant disease-free survival rates were 59.29$\%$ and 81.46$\%$ in the radiation alone and chemoradiation groups, respectively (p=0.477), Treatment related hematologic toxicity were prominent in the chemoradiation group. Leukopenia $\geq$grade) occurred in 3.2$\%$and 28.5$\%$ of the radiation alone and chemoradiation groups, respectively (p=0.02). There were no statistical differences in the incidences of vesical, rectal and small bowel complications between two groups. Conclusion: Radiation therapy with low dose cisplatin did not improve the rates of survival and response rates, but did improve the rate of disease free survival and locoregional control rates In locally advanced cervical cancer. The incidence of bone marrow suppression was higher in the chemoradiation group.

A Comparative Study of Christian Dior's and Martin Margiela's Fashion Works in Terms of Iconology (Christian Dior과 Martin Margiela 패션 작품 도상에 대한 비교 연구)

  • Yun, Ji-Young
    • Journal of the Korean Society of Costume
    • /
    • v.59 no.5
    • /
    • pp.115-134
    • /
    • 2009
  • This study is about Christian Dior's and Martin Margiela's fashion works that create 'New look' which leads the periodic ideology, philosophies, circumstances and the trend at that time. For the systematized interpretation, this study investigates the iconology of E. Panofsky, E. H. Gombrich and N. Goodman. Based on their theories, iconological analysis paradigm is made into four phases: I. Recognition of iconological form, II. Analysis of External Elements, III. Analysis of symbolic meanings and artistic will and IV. Aesthetic enjoyment and communication with a viewer. Christian Dior treats woman as a organic and architectural structure. He falls in love with himself such as narcissus and woman who wears his works. Dior's ego is visualized by woman and his works which are the symbol of narcissism and beauty. Martin Margiela makes form of clothes and at the same time destroys. Margiela deconstructs aura of clothes and tries to make it unfamiliar. Also he changes traditional idea of beauty and creates 'ugliness' which is a notion of dialectic. Margiela transforms elements of clothes which brings variation of thinking and makes it possible to create new look. Christian Dior and Martin Margiela are the creators of new look which visualizes the notion of habitus that is the space of self-exists. Fashion dose not have to be what people wears but it could be an image itself. It means that fashion is a part of ontology and it is a 'New look' which is based on economy, the standard of periodical beauty and ideal aspects. The creation of clothes is a work of embodiment of human being where it constructed or deconstructed.

Study on The Technical Improvement in Wireless Power Communication System with Low Power (무선전력통신 시스템의 저전력화를 위한 기술적 개선방안)

  • Chung, Sung-In;Lee, Seung-Min;Lee, Hyo-Sung;Lee, Hug-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.1
    • /
    • pp.53-57
    • /
    • 2010
  • This study proposes the algorithm which drives the powerless without battery. The exiting wire or RF type dosimeter, which is the computation of the real time with battery on the dose radiation exposure, In the Wired dosimeter, it is trouble to need the maintenance and management by periods. Besides, the case of the RF typed dosimeter with battery, it is requested to size bigger and to replace battery frequently and so on. Especially RF typed dosimeter has trouble to need for the embody with large power consumption on the contactless typed dosimeter. As the method for the low power, the study designed to be down the operating clock of the MPC, to improve the efficiency of the rectifier, to eliminate the external memory and the DC-DC converter for the simplification of the circuit We convince our research contributes not only to understand the simplified circuit and miniaturization, but also to help the design and application technology of the powerless dosimeter.

Radiation Exposure and Cancer Mortality Among Nuclear Power Plant Workers: a Meta-analysis (원전종사자의 방사선 노출과 암사망 위험도와의 관련성에 대한 메타분석)

  • Park, Eun-Sook;Moon, Ki-Eun;Kim, Han-Na;Lee, Won-Jin;Jin, Young-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.2
    • /
    • pp.185-192
    • /
    • 2010
  • Objectives: We conducted a meta-analysis to investigate the relationship between low external doses of ionizing radiation exposure and the risk of cancer mortality among nuclear power plant workers. Methods: We searched MEDLINE using key words related to low dose and cancer risk. The selected articles were restricted to those written in English from 1990 to January 2009. We excluded those studies with no fit to the selection criteria and we included the cited references in published articles to minimize publication bias. Through this process, a total of 11 epidemiologic studies were finally included. A publication bias was tested for using Egger's test. The homogeneity test was performed before the integration of each of the standardized mortality ratios (SMRs) and the result proved that the studies were heterogeneous. Results: We found significant decreased deaths from all cancers (SMR = 0.75, 95% CI = 0.62 - 0.90), all cancers excluding leukemia, solid cancer, mouth and pharynx, esophagus, stomach, rectum, liver and gallbladder, pancreas, lung, prostate, lymphopoietic and hematopoitic cancer. The findings of this meta-analysis were similar with those of the 15 Country Collaborative Study conducted by the International Agency for Research on Cancer. A publication bias was found only for liver and gallbladder cancer (p = 0.015). Heterogeneity was observed for all cancers, all cancers excluding leukemia, solid cancer, esophagus, colon and lung cancer. Conclusions: Our findings of low mortality for stomach, rectum, liver and gallbladder cancers may explained by the health worker effect. Yet further studies are needed to clarify the low SMR of cancers, for which there is no useful screening tool, in nuclear power plant workers.

Clinical Results of $Cyberknife^{(R)}$ Radiosurgery for Spinal Metastases

  • Chang, Ung-Kyu;Youn, Sang-Min;Park, Sukh-Que;Rhee, Chang-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.538-544
    • /
    • 2009
  • Objective : Primary treatment of spinal metastasis has been external beam radiotherapy. Recent advance of technology enables radiosurgery to be extended to extracranial lesions. The purpose of this study was to determine the clinical effectiveness and safety of stereotactic radiosurgery using Cyberknife in spinal metastasis. Methods : From June, 2002 to December, 2007, 129 patients with 167 spinal metastases were treated with Cyberknife. Most of the patients (94%) presented with pain and nine patients suffered from motor deficits. Twelve patients were asymptomatic. Fifty-three patients (32%) had previous radiation therapy. Using Cyberknife, 16-39 Gy in 1-5 fractions were delivered to spinal metastatic lesions. Radiation dose was not different regarding the tumor pathology or tumor volume. Results : After six months follow-up, patient evaluation was possible in 108 lesions. Among them, significant pain relief was seen in 98 lesions (91%). Radiological data were obtained in 83 lesions. The mass size was decreased or stable in 75 lesions and increased in eight lesions. Radiological control failure cases were hepatocellular carcinoma (5 cases), lung cancer (1 case), breast cancer (1 case) and renal cell carcinoma (1 case). Treatment-related radiation injury was not detected. Conclusion : Cyberknife radiosurgery is clinically effective and safe for spinal metastases. It is true even in previously irradiated patients. Compared to conventional radiation therapy, Cyberknife shows higher pain control rate and its treatment process is more convenient for patients. Thus, it can be regarded as a primary treatment modality for spinal metastases.

Combined chemotherapy and intra-arterial chemotherapy of retinoblastoma

  • Choi, Saerom;Han, Jung Woo;Kim, Hyosun;Kim, Beom Sik;Kim, Dong Joon;Lee, Sung Chul;Lyu, Chuhl Joo
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.6
    • /
    • pp.254-259
    • /
    • 2013
  • Purpose: Retinoblastoma (RB) is the most common primary malignant intraocular tumor in children. Although systemic chemotherapy has been the primary treatment, intra-arterial chemotherapy (IAC) represents a new treatment option. Here, we performed alternate systemic chemotherapy and IAC and retrospectively reviewed the efficacy and safety of this approach. Methods: Patients diagnosed with intraocular RB between January 2000 and December 2011 at Severance Children's Hospital, Yonsei University, were reviewed. Before February 2010, the primary treatment for RB was chemotherapy (non-IAC/CTX). Since February 2010, the primary treatment for RB has been IAC (IAC/CTX). External beam radiotherapy or high-dose chemotherapy were used as "last resort" treatments just prior to enucleation at the time of progression or recurrence during primary treatment. Enucleation-free survival (EFS) and progression-free survival were assessed. Results: We examined 19 patients (median age, 11.9 months; range, 1.4 to 75.6 months) with a sum of 25 eyes, of which, 60.0% were at advanced Reese Ellsworth (RE) stages. The enucleation rate was 33.3% at early RE stages and 81.8% at advanced RE stages (P=0.028). At 36 months, EFS was significantly higher in the IAC/CTX group than in the non-IAC/CTX group (100% vs. 40.0%, P=0.016). All 5 patients treated with IAC achieved eye preservation, although most patients were at advanced RE stages (IV-V). Conclusion: Despite the limitation of a small sample size, our work shows that an alternative combined approach using IAC and CTX may be safe and effective for eye preservation in advanced RB.

Calculation of Trajectory for High Energy Electrons in Water under Strong Magnetic Fields (강자기장이 인가된 물 속에서 고에너지 전자의 궤적 계산)

  • Kim Jeung Kee;Oh Young Kee;Shin Kyo Chul;Kim Ki Hwan;Kim Jhin Kee;Kim Sung Kyu;Ro Tae Ik;Kim Jin Young;Ji Young Hun;Jeong Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.121-127
    • /
    • 2004
  • The trajectories for high-energy electrons in water under magnetic fields were calculated approximately by numerical method. A differential equation for electrons under magnetic field was built and the calculation code was devised by Euler method. Using the code, the trajectories for electrons with energies of 3, 5, 10, and 15 MeV in water were calculated in the presence of magnetic fields parallel and perpendicular to the incident electrons. Since we considered only the energy loss and the directional change for primary electrons, there are errors in this calculation. However, based on the results we were able to explain the variation of dose distributions by the external magnetic fields in water.

  • PDF

A study on the Correlationship between Detergency of Commercial Detergents and Rolling-up (시판세제의 세정성과 Rolling-up의 상관성에 관한 연구)

  • Lee Kyung Mi;Cha Ok Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.3
    • /
    • pp.27-36
    • /
    • 1986
  • The purpose of this study was, to estimate the detergency of commercial detergent and to examine the interrelationship between detergency and detergent characteristics, detergent concentration, fiber characteristics, and Rolling-up phenomenon which is the major removal mechanism of oily soil. A mixture of oleic acid-olive oil was used as oily soil. The detergency was estimated by analysis of oleic acid on cotton ana polyester fabrics before and after washing by means of liquid scintillation counting. The Rolling-up of oily soil from PET film was observed and change of contact angle and removal time were measured. The results were as follows ; 1. In the case of soaps and powder synthetic detergents, the optimum concentrations we-re about $0.2\~0.3\%$. And detergencies of liquid synthetic detergents were considerably low, and the detergency was continually increased up with increasing concentration to $0.5\%$, which seemed to be caused by the lower pH than that of soap and powder synthetic deter-gent solutions. 2. As the effect of external or internal fiber structure; the detergency of cotton was lower than that of polyester. 3. In the observation of Rolling-up, the contact angle increased and the Rolling-up time became shorter with increasing detergent concentrations ($0.05\~0.5\%$). And it was confirmed that detergency was increased with Rolling-up effect. In addition, the study on the actual laundry condition was studied using the questionaire. From the results, about $76\%$ of households used the concentration of detergent roughly or excessively and housewives were highly concerned on the recommended dose, but grade of practice were very low.

  • PDF