• Title/Summary/Keyword: external ODD

Search Result 15, Processing Time 0.019 seconds

Narrator as Collective 'We': The Narrative Structure of "A Rose for Emily"

  • Kim, Ji-Won
    • English Language & Literature Teaching
    • /
    • v.17 no.4
    • /
    • pp.141-156
    • /
    • 2011
  • This study purposes to explore the narrative of fictional events complicated by a specific narrator, taking notice of his/her role as an internal focalizer as well as an external participant. In William Faulkner's "A Rose for Emily," the story of an eccentric spinster, Emily Grierson, is focalized and narrated by a townsperson, apparently an individual, but one who always speaks as 'we.' This tale-teller, as a first-hand witness of the events in the story, details the strange circumstances of Emily's life and her odd relationships with her father, her lover, the community, and even the horrible secret hidden to the climactic moment at the end. The narrative 'we' has surely watched Emily for many years with a considerable interest but also with a respectful distance. Being left unidentified on purpose, this narrative agent, in spite of his/her vagueness, definitely knows more than others do and acts undoubtedly as a pivotal role in this tale of grotesque love. Seamlessly juxtaposing the present and the past, the collective 'we' suggests an important subject that the distinction between the past and the present is blurred out for Emily, for whom the indiscernibleness of time flow proves to be her hamartia. The focalizer-narrator describes Miss Emily in the same manner as he/she describes the South whose old ways have passed on by time. Like the Old South, Emily is desperately trapped in the past, since she has not been able to adjust to the changes brought on by time. In the end, the tragic story of Emily Grierson which takes place in Jefferson plainly seems to serve as an introduction to mature Faulkner.

  • PDF

Gold Beads Implants for The Treatment of Canine Chronic Recurrent Otitis Externa

  • Sumano, Hector;Tapia-Perez, Graciela;Gutierrez, Lilia
    • Journal of Veterinary Clinics
    • /
    • v.30 no.2
    • /
    • pp.100-106
    • /
    • 2013
  • A clinical trial was performed to assess clinical efficacy and/or reduction in relapses by gold-bead implantation into acupuncture points in dogs with canine chronic recurrent otitis externa (CCROE). Forty dog-patients randomly divided into two groups were diagnosed as suffering CCROE, having intact tympanic membranes and a history of recurrences. Treatments were: control group (CG), treated with commercially available antimicrobial otic droplets, dosed twice daily for 7 days; and experimental group (GBI- gold bead implants), treated as for CG plus the insertion of 13 gold-bead implants under light anesthesia. Overall per cent assessment of composite clinical progression and progression of individual clinical signs were recorded. Bilateral chronic external otitis was diagnosed in 60% of the cases and left or right otitis in 20% of the cases each. Logistic model for repeated measures analysis showed that GBI induced a better clinical recovery as far as lesion score of some clinical signs is concerned. The overall percent cures of each group showed statistically significant difference. A McNemar analysis revealed that higher number of relapses was observed in CG patients as compared to the GBI (P < 0.05). In particular during these days, lesion on the pinna showed in odd ratios analysis a 7:1 ratio (recurrence CG:GBI) and ear wax/pus (4:1) from D42 to D365. It is concluded that gold-bead implantation into acupuncture points improves resolution of some clinical signs and greatly reduce relapses in CCROE affected dogs after 1 year follow-up (98.75%).

South Korean and Japanese intention to use automated external defibrillators in out-of-hospital cardiac arrest situations (일반인의 AED 사용에 관한 한·일 비교 연구)

  • Leem, Seung-Hwan
    • The Korean Journal of Emergency Medical Services
    • /
    • v.18 no.1
    • /
    • pp.17-27
    • /
    • 2014
  • Purpose : The purpose of the study is to investigate the factors influencing using AED use in South Korea and Japan. Methods : I conducted a questionnaire survey from February 25 to March 4, 2013, receiving responses from 517 people in Korea and 520 people in Japan. The questionnaire included sociodemographic factors, history of heart disease, AED knowledge, and other variables. A logistic regression analysis was conducted. Results : Among the 517 Korean respondents, 220 (42.6%) intended to use AEDs. Among the 520 Japanese respondents, 384 (74.4%) had similar intentions. Multiple logistic regression analysis found the following significant predictors of intent to use AEDs: gender (odds ratio [OR] = 0.419), household income (OR = 0.991), and AED knowledge (OR = 2.833) in Korea; and gender (OR = 0.582), age (OR = 0.968), cardiac disease history (OR = 2.099), and AED knowledge (OR = 2.984) in Japan. Conclusion : It would be helpful to teach AED use to encourage performing public access defibrillation. In addition, it is necessary to design AED education programs based on country-specific factors.

Durability and Crack Control of Concrete Using Fluosilicates Based Composite (규불화염계 복합 조성물을 혼입한 콘크리트의 균열제어 및 내구성)

  • Yun, Hyun-Do;Yang, Il-Seung;Kim, Do-Su;Khil, Bae-Su;Han, Seung-Gu
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.57-64
    • /
    • 2006
  • The crack presented in concrete structures causes a structural defect, the durability decrease, and external damages etc. Therefore, it is necessary to improve durability through the effort to control the crack. Fluosilicic acid($H_2SiF_6$) is recovered as aqueous solution which absorbs $SiF_4$ produced from the manufacturing of industrial-graded $H_3PO_4$ or HF. Generally, fluosilicates prepared by the reaction between $H_2SiF_6$ and metal salts. Addition of fluosilicates to cement endows odd properties through unique chemical reaction with the fresh and hardened cement. Mix proportions for experiment were modulated at 0.45 of water to cement ratio and $0.0{\sim}2.0%$ of adding ratio of fluosilicate salt based inorganic compound. To evaluate correlation of concrete strength and adding ratio of fluosilicate salt based inorganic compound, the tests were performed about design strength(21, 24, 27 MPa) with 0.5% of adding ratio of fluosilicate salt based inorganic compound. Applications of fluosilicate salt based inorganic compound to reduce cracks resulted from plastic and drying shrinkage, to improve durability are presented in this paper. Durability was evaluated as neutralization, chloride ion penetration depth, freezing thawing resistant tests and weight loss according reinforcement corrosion. It is ascertained that the concrete added fluosilicate salt based inorganic compound showed m ability to reduce the total area and maximum crack width significantly as compared non-added concrete. In addition, the durability of concrete improved because of resistance to crack and watertightness by packing role of fluosilicate salt based inorganic compound obtained and pozzolanic reaction of soluble $SiO_2$ than non-added concrete.

A 8b 1GS/s Fractional Folding-Interpolation ADC with a Novel Digital Encoding Technique (새로운 디지털 인코딩 기법을 적용한 8비트 1GS/s 프랙셔널 폴딩-인터폴레이션 ADC)

  • Choi, Donggwi;Kim, Daeyun;Song, Minkyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.137-147
    • /
    • 2013
  • In this paper, an 1.2V 8b 1GS/s A/D Converter(ADC) based on a folding architecture with a resistive interpolation technique is described. In order to overcome the asymmetrical boundary-condition error of conventional folding ADCs, a novel scheme with an odd number of folding blocks and a fractional folding rate are proposed. Further, a new digital encoding technique with an arithmetic adder is described to implement the proposed fractional folding technique. The proposed ADC employs an iterating offset self-calibration technique and a digital error correction circuit to minimize device mismatch and external noise The chip has been fabricated with a 1.2V 0.13um 1-poly 6-metal CMOS technology. The effective chip area is $2.1mm^2$ (ADC core : $1.4mm^2$, calibration engine : $0.7mm^2$) and the power dissipation is about 350mW including calibration engine at 1.2V power supply. The measured result of SNDR is 46.22dB, when Fin = 10MHz at Fs = 1GHz. Both the INL and DNL are within 1LSB with the self-calibration circuit.