• Title/Summary/Keyword: extension distance

Search Result 307, Processing Time 0.026 seconds

Estimation of environmental damage assessment in the shoreline after the NAKHODKA oil-spill using Geo-informatics

  • Kim, Sang-Woo;Goto, Shintaro;Matui, Kouji;Shikada, Masaaki;Shikida, Asami;Sawano, Nobuhiro
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.443-449
    • /
    • 1999
  • The investigation of the amount of the ecosystem damage on the shoreline due to the NAHODKA oil-spill accident, which occurred in the Sea of Japan, was attempted by using geoinformatics. At first, it was assumed that symbolical vegetation's distribution could be specified in the coast in Ishikawa Pref. where the heavy oil was washed, and surveyed the regional distribution. Then, the presumption result of those environmental capacities was arranged by GIS. In addition, the amount of the ecosystem damage was presumed as cost necessary though a symbolical living thing for the retreat because of the base line by the heavy oil drifting ashore was recovered. By comparing the vegetation line and the surveying data which shows environmental capacity, the retreat areas of the vegetation were 1100-1200 $m^2$. When the amount of damage on the ecosystem of the NAHODKA oil-spill accident was presumed based on the retreat area of this vegetation and the restoration cost, the amount of damage within Shioya beach which 150m in the surveying range became 2 to 2.5 million Yen. Because the extension distance from the Shioya beach to the Katano beach was about 3,500m, the amount of damage became about 46 to 65 million Yen. As a result of calculation for the amount of damage on the ecosystem of the NAHODKA oil-spill accident, it was estimated approximately 1,400 to 2,000 million Yen in the shoreline of Ishikawa Pref., because the total extension of beaches in Ishikawa Pref. is about 110km.

  • PDF

Classification of Korean Green Tea Products Based on Chemical Components

  • Chun Jong Un;Choi Jeong;Lim Keun-Cheol;Kim Yong-Gul
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.4
    • /
    • pp.295-299
    • /
    • 2004
  • The prices of domestic green tea products are relatively expensive and price differences within products of the same levels of quality are various. Also, there is no basic criteria on evaluation of green tea quality. To group 43 commercial green tea products into several parts by the principal component and cluster analyses, this work was done by use of 8 chemical constituents which were analyzed by NIR system. The principal component and cluster analyses revealed 8 groups. The first group included 16 products that had lower free amino acid and theanine contents. The second group included 5 products having higher free amino acid and theanine contents, but lower ash contents. The third group included 13 products showing medium values of 8 constituents. The IV group included 4 products having higher contents of moisture, free amino acids, and theanine. The V group included 1 product showing higher moisture but lower catechins contents. The VI group included 2 products that had higher moisture and catechins contents, but lower free amino acid and theanine contents. The VII group had higher moisture and catechins contents. The VIII group had higher ash and vitamin C contents. The free amino acid contents which were the most important in flavor evaluation of green tea quality did highly positively correlate with the contents of total nitrogen $(0.956^{**}),\;theanine\;(0.981^{**}),\;and\;caffeine\;(0.793^{**})$, but negatively with the contents of ash $(-0.884^{**})$. The catechins used as for functional ingredients did correlate with contents of caffeine(+) and vitamin C(-), respectively.

Kinematic Analyses of Women's Pole Vault in IAAF World Championships, Daegu 2011 (2011 대구 세계육상선수권대회 여자 장대높이뛰기경기 기술의 운동학적 분석)

  • Choi, Kyoo-Jeong;Yi, Kyung-Ok;Kim, Nam-Hee;Kang, Ji-Eun;Kim, Hye-Lim
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.561-571
    • /
    • 2011
  • The purpose of this study was to perform the kinematic analyses of the women's pole vault skills in IAAF World Championships Daegu 2011. Subjects were the 1st through 8th place finishers in the pole vault. The kinematic analyses were divided into four phases: two dimensional run up analysis, and three dimensional analyses for the remaining plant, swing up, and extension phases. Run-up variables consisted of run up distance, number of steps, average step length, ratio of step length to height, average velocity at the final 5~10 m, approach position. Three variables were analyzed during plant: pole angle, center of gravity (COG) velocity, and COG takeoff angle. Swing up phase variables included: pole flection angle, COG velocity (horizontal, vertical, resultant), COG trajectory and bar approach angle of COG. Compared to the 2009 World Championships in Berlin, the average vault height increased, while run up velocity and approach position were almost unchanged. However, horizontal velocity during the last two steps of the final approach decreased noticeably compared to speeds from 1990. These results reflect the change in both technique and physical fitness in pole vaulters. During extension, the peak height of COG surpassed the clearance height by an average of 0.11m. These specific results can help coaches and athletes modify training and improve performance.

Kinematic Analyses of Men's Pole Vault in IAAF World Championships, Daegu 2011 (2011 대구 세계육상선수권대회 남자 장대높이뛰기경기 기술의 운동학적 분석)

  • Choi, Kyoo-Jeong;Yi, Kyung-Ok;Kim, Nam-Hee;Kang, Ji-Eun;Kim, Hye-Lim
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.551-560
    • /
    • 2011
  • The purpose of this study was to perform the kinematic analyses of the men's pole vault skills in IAAF World Championships Daegu 2011. Subjects were the 1st through 8th place finishers in the pole vault. The kinematic analyses were divided into four phases: two dimensional run up analysis, and three dimensional analyses for the remaining plant, swing up, and extension phases. Run-up variables consisted of run up distance, number of steps, average step length, the ratio of step length to his height, average velocity at the final 6~11 m, approach position. Three variables were analyzed during plant: pole angle, center of gravity (COG) velocity, and takeoff angle of COG. Swing up phase variables included: pole flexion angle, COG velocity (horizontal, vertical, resultant), COG trajectory and bar approach angle of COG. Compared to the 2009 World Championships in Berlin, the average vault height, run up velocity and approach position increased. However, horizontal velocity during the last two steps of the final approach decreased dramatically compared to speeds from 1990. These results reflect the change in both technique and improved physical fitness in pole vaulters. During extension, the peak height of COG averaged 0.3m higher then COG height when the pole was released. These specific results can help coaches and athletes modify training and improve performance.

Analysis of the Macroscopic Traffic Flow Changes using the Two-Fluid Model by the Improvements of the Traffic Signal Control System (Two-Fluid Model을 이용한 교통신호제어시스템 개선에 따른 거시적 교통류 변화 분석)

  • Jeong, Yeong-Je;Kim, Yeong-Chan;Kim, Dae-Ho
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.1
    • /
    • pp.27-34
    • /
    • 2009
  • The operational effect of traffic signal control improvement was evaluated using the Two-Fluid Model. The parameters engaged in the Two-Fluid Model becomes food indicators to measure the quality of traffic flow due to the improvement of traffic signal operation. A series of experiment were conduced for the 31 signalized intersections in Uijeongbu City. To estimate the parameters in the Two-Fluid Model the trajectory informations of individual vehicles were collected using the CORSIM and Run Time Extension. The test results showed 35 percent decrease of average minimum trip time per unit distance. One of the parameters in the Two-Fluid Model is a measure of the resistance of the network to the degraded operation with the increased demand. The test result showed 28 percent decrease of this parameter. In spite of the simulation results of the arterial flow, it was concluded that the Two-Fluid Model is useful tool to evaluate the improvement of the traffic signal control system from the macroscopic aspect.

A Study on the Protection System on the Electric Railways (전철급전회로 보호시스템에 관한 연구)

  • Chang, Sang-Hoon;Lee, Chang-Moo;Han, Moon-Seob;Oh, Kwang-Hae;Shin, Han-Soon;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1166-1169
    • /
    • 1998
  • The Load characteristic of electric railway requires the power demand of the high capacity which amplitude is spacial-temporally fluctuated due to frequent starting and stopping with large tractive force. The conventional electric railway mainly consists of the resistance controlled and the thyristor controlled locomotives, are compensated for their bad characteristics of the power factor$(70\sim80%)$ with installation of another capacitor improving power factor at the substation. Since 1994, VVVF train car with good characteristics of power factor(100%) have been introduced and operated in Kwa-Chon Line. From the present technical tendency, it is judged that introduction of the locomotive with various controlled methods is necessary. The protective equipments installed at the substation are complicated and various aspects to detect faults and reduce their extension, so the universal countermeasures are required. Specially in the case of the fault occurrence it is difficult to calculate the fault location because of the change in the contactline constant according to modifying the characteristics of the contactline (the dualized catenary wire and extension, etc), so much time is required for the detection of fault location. In BT-fed method distance-relays and fault-locators are not installed, we have so many difficulties in the quick accident recovery.

  • PDF

The Motion Analysis of the Scaphoid, Capitate and Lunate During Dart-Throwing Motion Using 3D Images (3차원 영상을 이용한 다트 던지기 운동에서의 주상골, 유두골, 월상골의 움직임 분석)

  • Park, Chan-Soo;Kim, Kwang-Gi;Kim, Yu-Shin;Jeong, Chang-Bu;Jang, Ik-Gyu;Lee, Sang-Lim;Oh, Su-Chan;Yu, Do-Hyun;Baek, Goo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.144-150
    • /
    • 2011
  • The primary purpose of this study was to analyze the motion of the scaphoid, capitate, and lunate during dart-throwing motion by three-dimensional modeling. Five series of CT images of five normal right wrists were acquired from five motion steps from radial extension to ulnar flexion in the dart-throwing motion plane. Segmentation and three-dimensional modeling of bones from CT images was performed using Analyze. Distances among centroids of the scaphoid, capitate and lunate and angles between principal axes of three carpal bones were calculated to analyze the motion by using MATLAB. As the wrist motion changed from radial extension to ulnar flexion, the distance between two adjacent bones decreased. The scaphoid and lunate rotated less than the capitates during dart-throwing motion. This study reports the Three-dimensional in vivo measurement of carpal motion using CT images.

The Effect of the Resistance of Wedge Frame on the Clamping Force of the Rail Clamp (쐐기프레임의 저항력이 레일클램프의 압착력에 미치는 영향)

  • Han Dong-Seop;Shim Jae-Joon;Lee Kwon-Hee;Han Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.355-360
    • /
    • 2006
  • The damping force of a jaw pad is determined by the displacements of main part when two lockers are locked, after the damping angle of a locker was set up in the wedge type rail damp for a container crane. In this time, of the resistance of wedge frame generates due to several factors, the damping angle of a locker to display the initial clamping force will be changed because of the reduction of displacement of extension bar. This resistance is determined by the eccentric distance between the roller and the wedge, and by the gap between the wedge frame and outer frame. In this study we measured the tensile force of both extension bar through the performance test of the prototype rail damp in order to evaluate the effect of the resistance of wedge frame on the damping force of the wedge type rail clamp.

  • PDF

Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing (은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.

Effects of the Active Static Stretching and Eccentric Exercise of Hamstring Muscles on Flexibility, Strength, and Agility Performance

  • Kang, Ji-Hun;Kang, Eun-Hyo;Jeon, Jeongwoo;Hong, Jihoen;Yu, Jaeho;Kim, Jinseop;Kim, Seong-Gil;Lee, Dongyeop
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.2
    • /
    • pp.115-123
    • /
    • 2022
  • Purpose : The hamstring is a group of three muscles, biceps femoris, semitendinosus, and semimembranosus, placed behind the thigh. The hamstring is one of the most commonly injured muscles and usually occurs during high-speed, high-intensity exercise. The purpose of this study was to investigate the effect of static stretching and eccentric exercise of hamstrings on flexibility, strength, and functional performance. Methods : This study was conducted on 28 healthy adults. Subjects were divided into a static stretching group (n=15) and an eccentric exercise group (n=13). Subjects measured hamstring flexibility (active knee extension test), hamstring strength (concentric and eccentric peak torque), and functional performance (triple hop for distance and modified 20 m sprint). The intervention was conducted three times a week for six weeks. To compare the difference between values before and after the intervention, paired t-test was used, and an independent t-test was used to compare between groups. Results : In both groups, the active knee extension test, concentric peak torque, triple hop test, and 20 m sprint significantly increased after the intervention compared to before the intervention (p<.05). However, no significant difference was found in eccentric peak torque after intervention in both groups (p>.05). No significant difference was found between the two groups in the effect on the variables (p>.05). Conclusion : Both interventions were found to be effective for flexibility, concentric strength, and functional performance. Eccentric exercise and static stretching are recommended to improve the flexibility and functional performance of the hamstring. This study's results will be considered essential data on the effectiveness of static stretching and eccentric exercise.