• 제목/요약/키워드: extended depth of field

검색결과 68건 처리시간 0.028초

기름방울 형상 및 그 체적 분석법 (Droplet Geometry and Its Volume Analysis)

  • 윤문철
    • Tribology and Lubricants
    • /
    • 제24권6호
    • /
    • pp.320-325
    • /
    • 2008
  • The recent industrial application requires technical methods to get the cutting fluid droplet surfaces in particular from the viewpoint of topography and micro texture. To characterize the surface topography of droplet, the combination of the confocal laser scanning microscope (CLSM) and wavelet filtering is well suited for obtaining the droplet geometry encountered in tribological research. This technique indicates a better agreement in obtaining an appropriate droplet surface obtained by the CLSM over a detail range of surface accuracy (resolution: $2{\mu}m$). And the results allow an excellent accuracy in a measurement of a droplet surface. The combination of extended focal depth measurement configured and multi-scale wavelet filtering has proven that it can construct a droplet surface in a successive and accurate way. A multi-scale approach of wavelet filtering was developed based on the decomposition and reconstruction of droplet surface by 2D wavelet transform using db9 (a mother wavelet of daubechies). Also this technique can be extended to characterize the quantification of droplet properties and other field in a wide range of scales. Finally this method is verified to be a better droplet surface modeling in a micro scale arising in a mist machining.

An Amorphous Silicon Local Interconnection (ASLI) CMOS with Self-Aligned Source/Drain and Its Electrical Characteristics

  • Yoon, Yong-Sun;Baek, Kyu-Ha;Park, Jong-Moon;Nam, Kee-Soo
    • ETRI Journal
    • /
    • 제19권4호
    • /
    • pp.402-413
    • /
    • 1997
  • A CMOS device which has an extended heavily-doped amorphous silicon source/drain layer on the field oxide and an amorphous silicon local interconnection (ASLI) layer in the self-aligned source/drain region has been studied. The ASLI layer has some important roles of the local interconnections from the extended source/drain to the bulk source/drain and the path of the dopant diffusion sources to the bulk. The junction depth and the area of the source/drain can be controlled easily by the ASLI layer thickness. The device in this paper not only has very small area of source/drain junctions, but has very shallow junction depths than those of the conventional CMOS device. An operating speed, however, is enhanced significantly compared with the conventional ones, because the junction capacitance of the source/drain is reduced remarkably due to the very small area of source/drain junctions. For a 71-stage unloaded CMOS ring oscillator, 128 ps/gate has been obtained at power supply voltage of 3.3V. Utilizing this proposed structure, a buried channel PMOS device for the deep submicron regime, known to be difficult to implement, can be fabricated easily.

  • PDF

고속전철 PSC 박스거더교 합성거동의 현장 계측에 관한 연구 (Field Investigation of Composite Behavior in High-speed Railway PSC Box Girder Bridge)

  • 김영진;김병석;강재윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.995-1000
    • /
    • 2000
  • Segmentally erected prestressed concrete box girder bridges have been widely used in Korean high speed railway. Segmental erection has been accomplished along the longitudinal direction and across the depth of cross section. The cross section is similar to a composite cross section, composed of old and new segments. Because these segments have different time-dependent creep and shrinkage properties, a stress redistribution takes place during the construction period. It is the main objective in this research to investigate this behavior. An actual bridge was instrumented with 96 vibrating wire embedded type strain gauges, 6 electronic type steel strain gauges, and 75 thermocouples. Two span continuous high speed railway bridge was selected. Two points of importance, such as the midpoint of the first span and the point of interior support, along the span of the girder were chosen to monitor the time dependent behaviors for an extended period of time. The data collection was starting just after concrete girder were cast and is still going on. According to the measured results, the strain distributions across the depth of the section at midspan and interior support were not continuous and the important redistribution of stresses takes place. Thus, rational design of prestressed concrete composite box girder bridges need.

흡수 선량 분포의 수송방정식을 이용한 10 MV X-선의 모델 (High Energy Photon Beam Modeling Using Transport Theory for Calculation of Absorbed Dose Distribution)

  • 최동락;전하정;이명자
    • Radiation Oncology Journal
    • /
    • 제10권1호
    • /
    • pp.115-120
    • /
    • 1992
  • 물팬톰내에 조사된 10 MV X-선의 심부율을 입자의 수송이론을 근거로 한 1차원적인 모델을 이용하여 계산하였다. 계산된 이론식의 매개상수는 9개로 줄일 수 있었으며 실측치를 이용하여 비선형 회귀분석 방법으로 얻을 수 있다. 조사면과 선원간의 거리 및 깊이에따른 3차원적인 흡수선량분포의 계산식은 고에너지 광자선이 조사된 물팬톰내에서의 Beam Profile에 대한 시도함수를 이용하여 수송이론에의한 심부율계산을 3차원적으로 확장하였으며 흡수 선량 분포는 3차원적 위치의 함수로 널리 계산할 수 있다. 이 모델을 사용하여 계산된 이론값은 실험값과 $\pm12\%$ 이내의 만족할만큼 잘 일치하였다.

  • PDF

CONDUCTIVITIES OF SEA-BOTTOM SEDIMENTS

  • HoWoongShon
    • 지구물리
    • /
    • 제6권2호
    • /
    • pp.79-87
    • /
    • 2003
  • An in-situ four-electrode contact resistivity probe system was designed, and field-tested in submarine sediments. Seismic survey was also performed to support and compare the results of electric survey. The probe was designed to be driven to selected depths below the seafloor using a Vibracore system. The four insulated electrodes were, spaced equidistant across the wedge, were extended beyond the probe tip to minimize effects of sediment disturbance by the wedge insertion. In-situ measurements of resistivity were recorded on board by precision electronic equipment consisting of signal generators and processors, and by temperature- monitoring systems. Overall limits of uncertainty at respective depths below the seafloor are up to ±10% of the measured values. Best estimates of conductivity are considered to be ±3 percent of the reported values. Resistivity measurements were made at six sites in carbonate sediments to a maximum depth of penetration of about 5 m. Average values of conductivity range between 0.88 and 1.21 mho/m. The results show the seabed is composed of alternating layers of relatively high-conductivity material (0.8 to 1.4 mho/m) in thicknesses of more or less one meter and layers about 30 cm thick having relatively low conductivities (0.4 to 0.8 mho/m).

  • PDF

교호효과를 고려한 향상된 의사결정나무 알고리듬에 관한 연구 (Improved Decision Tree Algorithms by Considering Variables Interaction)

  • 권근섭;최경현
    • 대한산업공학회지
    • /
    • 제30권4호
    • /
    • pp.267-276
    • /
    • 2004
  • Much of previous attention on researches of the decision tree focuses on the splitting criteria and optimization of tree size. Nowadays the quantity of the data increase and relation of variables becomes very complex. And hence, this comes to have plenty number of unnecessary node and leaf. Consequently the confidence of the explanation and forecasting of the decision tree falls off. In this research report, we propose some decision tree algorithms considering the interaction of predictor variables. A generic algorithm, the k-1 Algorithm, dealing with the interaction with a combination of all predictor variable is presented. And then, the extended version k-k Algorithm which considers with the interaction every k-depth with a combination of some predictor variables. Also, we present an improved algorithm by introducing control parameter to the algorithms. The algorithms are tested by real field credit card data, census data, bank data, etc.

선형가속기의 6MV X선에 대한 소형조사면의 선량측정 (Dose Characteristics of Small Radiation Fields for 6MV X-ray of Linear Accelerator)

  • 최태진;김옥배;김영훈;손은익;김인홍
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.287-291
    • /
    • 1989
  • Radiation dosimetry has been extended to small fields less than $4\times4cm^2$ which may be suitable for irradiation of small intracranial tumors. Special consideration was given to the percentage depth dose and scatter correction factors with 0.14ml ion chamber, film dosimetry and TLD measurement. Calculated dose distributions were compared with measured data.

  • PDF

방사선치료시 물리학적 반음영의 검토 (Study on Physical Penumbra of Radiation Therapy)

  • 김영범;황웅구;김유현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.81-86
    • /
    • 1993
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing energy level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

방사선치료시 물리학적 반음영의 검토 (Study on Physical Penumbra of Radiation Therapy)

  • 김영범;황웅구;김유현
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.84-88
    • /
    • 1994
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing enery level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

Realistic Visual Simulation of Water Effects in Response to Human Motion using a Depth Camera

  • Kim, Jong-Hyun;Lee, Jung;Kim, Chang-Hun;Kim, Sun-Jeong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권2호
    • /
    • pp.1019-1031
    • /
    • 2017
  • In this study, we propose a new method for simulating water responding to human motion. Motion data obtained from motion-capture devices are represented as a jointed skeleton, which interacts with the velocity field in the water simulation. To integrate the motion data into the water simulation space, it is necessary to establish a mapping relationship between two fields with different properties. However, there can be severe numerical instability if the mapping breaks down, with the realism of the human-water interaction being adversely affected. To address this problem, our method extends the joint velocity mapped to each grid point to neighboring nodes. We refine these extended velocities to enable increased robustness in the water solver. Our experimental results demonstrate that water animation can be made to respond to human motions such as walking and jumping.