A Case Study on Health Impact Assessment from Petroleum Refinery Plant Operation - Human Risk Assessment due to Chemicals Inhalation - (석유정제시설 운영에 대한 건강영향평가 사례 연구 - 화학물질 흡입에 따른 인체 위해도 평가 -)

  • Myung, Nho-Il;Lee, Young-Soo;Shin, Dae-Yewn
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.259-270
    • /
    • 2010
  • We conducted human risk assessment for exposure to inhalation of chemical substances emitted from the storage tanks of petroleum refineries. To assess human risk, this study calculated chemical emissions from the external floating roofs on storage tank at petroleum refineries, as well as concentrations thereof in the ambient air using the K-SCREEN model, and then determined risk in accordance with the Reference Concentration (RfC) values and Inhalation Unit Risk criteria developed by the US Environmental Protection Agency. The results indicated that non-carcinogenic chemicals have a hazard quotient of less than 1, meaning they have an insignificant effect on human health for residential areas near the storage tanks. Among the known carcinogens, the hazard risk for benzene slightly exceeded $10^{-6}$, indicating the need for corrective reduction measures. The methodology for health impact assessment devised herein provides findings useful in decision making for policy makers and the general public with respect to construction of industrial complexes. However, the methodology proposed herein does have limitations, including discrepancy in results induced by use of U.S. data (due to the lack of usable domestic data). More systematic studies from related researchers will be needed to address these issues and produce more reliable outcomes.

A Methodology for Assessing Risk from Released Hydrocarbon (탄화수소 누출로 인한 위험분석 평가 방법론 연구)

  • Keun-Won Lee
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.170-180
    • /
    • 1998
  • This study presents a method for calculating the concentration of hydrocarbon releases in enclosed areas using empirical equations of evaporation rate. The approach of the method is to estimate the hydrocarbon exposure concentration in the air under conditions assumed. A methodology for assessing risk was suggested to individual risk assessment to exposed workers or others by probit expressions. The toxicity criteria and available human exposure data were examined and guidelines for risk assessment suggested for benzene-air and toluene-air systems. The value of probit constants with mole fractions of lethal concentrations in a mixture of hydrocarbons and a non-toxic substance was predicted. The probit values calculated with mole fractions can be used to estimate guidelines to prevent toxicity within enclosed working areas.

  • PDF

A Study on the Design of Pop Art Applied to T-Shirt (티셔츠에 표현된 팝아트 디자인 연구)

  • Kim, Eun-Ha;Cho, Jean-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.3
    • /
    • pp.409-424
    • /
    • 2008
  • This study intends to analyze T-shirt designs, particularly in connection with pop art. 444 pieces of T-shirts which conveyed the pop art spirits of well-known designers were selected for five years from 2001 to 2005, through fashion magazines(Collection: Dong-ah TV, Collezioni: Italy). The findings are as follows. As for formative characteristics of pop art in T-shirts, previous studies were analyzed to set classifications criteria such as popularization of images, eroticism, lettering and graffiti, assemblage. The design factor of the image popularization includes everyday images, cartoon, celebrities, and caricature. Everyday images ranked first followed by cartoon, caricature and celebrities. The design factor of eroticism ranges from the see-through look, partial exposure of human body, symbolization of underwear, and to printing of sexy images. The see-through look was ranked first, followed by partial exposure of human body, symbolization of underwear, and printing of sexy images. The design factor of lettering and graffiti encompasses letters, numbers, symbols and logos. Adoption of letters, numbers or symbols was ranked first, followed by brand logos and graffiti. The design factor of Assemblage is closely related to a three-dimensional effect. Varied expressions are possible: combination of two different textiles and fusion of textile and non-textile. Combination of two different textiles are higher than fusion of textile and non-textile.

  • PDF

Direction for the management of air pollutants based on health risk in Korea (위해성을 고려한 대기오염물질의 관리 방향)

  • Kim, Young Ju;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.43-52
    • /
    • 2017
  • Policy direction for the management of air quality in Korea has been on the reduction of the average concentrations of the criteria air pollutants such as sulfur dioxide and fine particles. However, recently, risk based management of air pollutants becomes an important issue. In this study, to develop an effective air quality management policy direction in Korea, (1) the fourth Multiple Air Toxics Exposure Study (MATES IV) carried out in the South Coast Air Quality Management District (SQAQMD) in the USA is reviewed and (2) the results are compared with in these in Seoul and (3) policy directions are suggested. It was found that (1) systematic integrated study comprising of measurement, modeling, emission inventory estimation, and risk assessment was essential to estimate the health risk of air pollutants reliably, (2) cancer risk of diesel particle was dominant over other air pollutants, and (3) health risk based emissions were different from amount based emissions. It was suggested that (1) reducing the exposure from hot spots might important to reduce health risk from air pollutants and (2) an integrated air quality management administration system is important for the efficient management of air pollution.

Rationale and Definition of The Criteria of The Efficiency of The Biological Activity of Optical Radiation on Animal Organism.

  • Chervinsky, Leonid S.
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.3
    • /
    • pp.1-5
    • /
    • 2018
  • In today's technological development of human society more and more influence on the lives of biological organisms different electromagnetic radiation. Therefore, the study and analysis of the mechanisms of their effects is an urgent task. The purpose of research - the study of the primary mechanisms of interaction of photons of optical radiation with the structures of biological objects, using the laws of quantum mechanics and biophysics. Photobiological basis of the mechanism of action of EMR optical range is the energy absorption of light quanta (photons) by atoms and molecules of biological structures (law Grotgus-Draper), which resulted in the formation of electronically excited states of these molecules with the transfer of photon energy (internal photoeffect). This is accompanied by electrolytic dissociation and ionization of biological molecules. The degree of manifestation of photobiological effects in the body depends on the intensity of the optical radiation, which is inversely proportional to the square of the distance from the source to the irradiated surface. Accordingly, in practice, determine not the intensity and irradiation dose at a certain distance from the source of exposure by the exposure time.

Transport Risk Assessment for On-Road/Sea Transport of Decommissioning Waste of Kori Unit 1

  • Woo Yong Kim;Hyun Woo Song;Jisoo Yoon;Moon Oh Kim
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.2
    • /
    • pp.255-269
    • /
    • 2023
  • Compared to operational wastes, nuclear power plant (NPP) decommissioning wastes are generated in larger quantities within a short time and include diverse types with a wider range of radiation characteristics. Currently used 200 L drums and IP-2 type transport containers are inefficient and restrictive in packaging and transporting decommissioning wastes. Therefore, new packaging and transport containers with greater size, loading weight, and shielding performance have been developed. When transporting radioactive materials, radiological safety should be assessed by reflecting parameters such as the type and quantity of the package, transport route, and transport environment. Thus far, safety evaluations of radioactive waste transport have mainly targeted operational wastes, that have less radioactivity and a smaller amount per transport than decommissioning wastes. Therefore, in this study, the possible radiation effects during the transport from NPP to disposal facilities were evaluated to reflect the characteristics of the newly developed containers and decommissioning wastes. According to the evaluation results, the exposure dose to transport workers, handling workers, and the public was lower than the domestic regulatory limit. In addition, all exposure dose results were confirmed, through sensitivity analysis, to satisfy the evaluation criteria even under circumstances when radioactive materials were released 100% from the container.

Outpatient Radioablation Therapy for Thyroid Cancer Patients with Minimal Radiation Exposure to the Family Members (갑상선암 환자의 방사선옥소 외래치료시 가족 구성원의 방사선량 측정)

  • Park, Hee-Myung;Jang, Jung-Woong;Yang, Hee-Chul;Kim, Young-Gook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.218-225
    • /
    • 2007
  • Purpose: Postoperative thyroid remnant radioablation therapy is necessary to reduce the recurrence and mortality rates as well as to prepare the patients for a proper long term surveillance of well-differentiated thyroid cancers. The radiation safety rules of the government require the patient to be isolated in a hospital if the expected radiation exposure to the family members would be greater than 5 mSv (500 mRem). The purpose was to measure the radiation received by the family members of patients who received large doses of NaI-131. Material and Methods: We have administered 12 therapy doses ranging from 3.70-5.55 GBq (100 to 150 mCi) to 11 patients, and released them immediately if they met the radiation safety criteria. Informed consent was obtained from the subjects prior to the therapy, and each of them agreed to follow written radiation safety instructions. TLD badges were used to measure the radiation dose received by the family members and the room adjacent to the patient's bed room during the first 72 hours. Results: The average dose received by the family members who spent the most time in the closest distance with the patients was 0.04 mSv with a range of 0.01-0.17 mSv. Even the highest dose was only about 3% of the limit set by the government. The average radiation dose to the outer wall of the patient's room was 0.15 mSv. Conclusion: It is concluded that I-131 ablation therapy can be administered to outpatients safely to thyroid cancer patients who meet the established radiation safety criteria and follow the instructions.

Vulnerability Assessment for Ocean to Climate Change Using Spatial Information Based on GIS (GIS 기반 공간정보를 이용한 해양부문의 기후변화 취약성 평가)

  • Park, Sun-Min;Lee, Woo-Kyun;Kwon, Tae-Hyub;Lee, Beo-Dul;Son, Yo-Whan;Cho, Yong-Sung
    • Spatial Information Research
    • /
    • v.19 no.3
    • /
    • pp.1-9
    • /
    • 2011
  • The vulnerability of ocean should be assessed to establish the climate change adaptation policy in field of the ocean, which has big effect on human and natural system. In this study, the criteria for assessing vulnerability of ocean to climate change were employed in terms of sensitivity, adaptative capacity and exposure. And suitable indicators for the criteria were selected and spatial data set for the indicators was prepared. In the ocean sector, the data for indicators were divided into two types, such as the inland and ocean data. The inland data were extrapolated and integrated to the coordinate of ocean data for the vulnerability assessment to climate change. As a result, the spatially diverse distribution of vulnerability on the ocean could be derived from the integration of two types of data. The results showed that southwestern ocean is much more sensitive than west and east ocean. Also southwestern ocean of exposure ratio of change is higher than the other part of ocean. On the other hand the adaptative capacity found that the highest in east ocean. The vulnerability assessment result showed southwestern ocean is more vulnerable than the other part of ocean.

Dose Reduction According to the Exposure Condition in Intervention Procedure : Focus on the Change of Dose Area and Image Quality (인터벤션 시 방사선조사 조건에 따른 선량감소 : 면적선량과 영상화질 변화를 중심으로)

  • Hwang, Jun-Ho;Jung, Ku-Min;Kim, Hyun-Soo;Kang, Byung-Sam;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.393-400
    • /
    • 2017
  • The purpose of this study is to suggest a method to reduce the dose by Analyzing the dose area product (DAP) and image quality according to the change of tube current using NEMA Phantom. The spatial resolution and low contrast resolution were used as evaluation criteria in addition to signal to noise ratio (SNR) and contrast to noise ratio (CNR), which are important image quality parameters of intervention. Tube voltage was fixed at 80 kVp and the amount of tube current was changed to 20, 30, 40, and 50 mAs, and the dose area product and image quality were compared and analyzed. As a result, the dose area product increased from $1066mGycm^2$ to $6160mGycm^2$ to 6 times as the condition increased, while the spatial resolution and low contrast resolution were higher than 20 mAs and 30 mAs, Spatial resolution and low contrast resolution were observed below the evaluation criteria. In addition, the SNR and CNR increased up to 30 mAs, slightly increased at 40 mAs, but not significantly different from the previous one, and decreased at 50 mAs. As a result, the exposure dose significantly increased due to overexposure of the test conditions and the image quality deteriorated in all areas of spatial resolution, low contrast resolution, SNR and CNR.

The Comparison of Noise-induced Hearing Loss Evaluation Criteria for Management (소음성난청 관리를 위한 판정기준간의 비교)

  • 남궁원자;원정일
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.123-134
    • /
    • 1998
  • The study was performed to investigate the differences among various evaluation criteria for noise-induced hearing loss(NIHL). The subjects were 100 workers who had received detailed audiometric examinations after the periodic annual examination for hearing loss. The evaluation criteria included were as follows: The criterion I was NIHL of 50dB or greater at 4,000Hz in either ear which is one of the legal requirements for determining occupational hearing loss in Korea. The criterion II was NIHL of 40dB or greater by 4-divided classification(a+b+c+d/4 at 500Hz(a), 1,000Hz(b), 2,000Hz(c), 4,000Hz(d)) which is also one of the legal requirements for determining occupational hearing loss in Korea. The criterion III was NIHL of 31dB of greater by 6-divided classification(a+2b+2c+d/6) which is the workers' compensation standard. The criterion IV was NIHL of 40dB or greater by 6-divided classification(a+2b+2c+d/6), the criterion used to prohibite workers to be employed in the noisy workplace. The criterion V was NIHL of 40dB or greater by 3-divided classification(a+b+c/3) which is the guideline of the Japanes Labour Department. The results were as follows; 1. The percentage of workers with NIHL by the criterion I was the highest(96%) and covered all workers with NIHL diagnosed by other criteria. Therefore, this criterion was the most sensitive one for early detection of NIHL among various evaluation criteria. 2. The percentage of workers with NIHL by the criterion II was 29% of the subjects, but all of them could be diagnosed as having NIHL by the criterion I and 33.1% of the NIHL by the criterion III could not be covered by the criterion II. Thus, this criterion was not considered suitable as an initial step for determining occupational hearing loss. 3. The percentage of workers with NIHL by the criterion III was 45% of the subjects. This percentage was 46.9% of the NIHL by the criterion I and was estimated to cover 3.6% of all noise exposed workers. 4. The percentage of workers with NIHL by the criterion IV was 28% of the subjects, but 37.8% of the NIHL by the criterion III and 70.8% of the NIHL by the criterion I were not covered by the criterion. Therefore, these workers could have been employed in the noisy workplaces. 5. Employed relocation which was one of the post management methods was an option in the criterion I in Korea and in the criterion V in Japan. The number of NIHL by the criterion I was 6.7times greater than that by the criterion V. Thus, although employee relocation was not used exclusively, many more workers with NIHL could have been relocated. In conclusion, this study revealed that the criteria being used for managing occupational hearing loss showed a lack uniformity among them. In addition, since these criteria are all relied on the total threshold shifts caused by the noise exposure at the time of hearing test with no consideration given to the past noise exposure history nor age, it can be said that they are not an effective tool for occupational hearing loss management. Since legal requirements are usually followed after being diagnosed as having NIHL, it is recommended that a uniform diagnostic criterion should be used to minimize confusion. Pre-employment hearing tests should also be utilized so as to managing occupational hearing loss after employment rather than being used as a legal roadblock of prohibiting workers with mild hearing loss from being employed. Thus, what is needed is an establishment of a rational criterion for occupational hearing loss management rather than for legal requirements.

  • PDF