• 제목/요약/키워드: exposure characteristics

검색결과 1,667건 처리시간 0.024초

사고대비물질 개인보호구 선정에 관한 연구(1): 물질유해성 및 작업위해성 분석 (A Study on Selecting Personal Protective Equipment for Listed Hazardous Chemicals (1): Analysis of Hazard Ranks and Workplace Exposure Risks)

  • 한돈희;정상태;김종일;조용성;이청수
    • 한국환경보건학회지
    • /
    • 제42권6호
    • /
    • pp.419-429
    • /
    • 2016
  • Objectives: According to the new Chemical Control Act from the Korean Ministry of Environment (2014-259), workers handling hazardous chemicals should wear personal protective equipment (PPE). However the act simply states in basic phrases that every worker handling one or more of the 69 listed chemicals should wear PPE and does not consider the unique hazard characteristics of chemicals and work types. The main purpose of this study is to provide basic data to revise the act to suit particular work processes and situations. Methods: The hazard rank of the substances was classified based on hazardous characteristics such as LC50 and vapor pressure using matrix analysis. The workplace exposure risk of the substances was also determined through a matrix analysis based on the previously determined hazard ranks and the demands of manual handling together with the likelihood of accident frequency of the operation combined with the exposure of workers during spill accidents. Results: To meet the demands for developing subsequent guidelines for the risk-based application of PPE in hazardous workplaces, this study sorted the 69 listed chemicals into five hazardous categories based on their LC50 and vapor pressures, and also assigned exposure categories according to exposure vulnerability for various types of work which are frequently performed throughout the life cycle of the chemicals. Conclusion: In the next study, an exposure risk matrix will be produced using the hazard rank of chemicals and workplace exposure risk, and then PPE will be selected to suit the categories of the exposure risk matrix.

Occupational Exposure to Refractory Ceramic Fibers in the Semiconductor Scrubber Manufacturing Industry

  • Song, Seungwhan;Kim, Sunju;Kim, Donghyeon;Yoon, Chungsik
    • Safety and Health at Work
    • /
    • 제13권3호
    • /
    • pp.357-363
    • /
    • 2022
  • Background: Refractory ceramic fibers (RCFs) are a suspected carcinogen but have been widely used as insulations. Depending on the temperature, RCFs can transform into crystalline SiO2, which is a carcinogen that can be present in the air during bulk RCF handling. This study analyzed the physicochemical and morphological characteristics of RCFs at high temperatures and determined the exposure levels during the semiconductor scrubber maintenance. Methods: Sampling was conducted at a company that manufactures semiconductor scrubbers using RCFs as insulation. Bulk RCF samples were collected both before and after exposure to a scrubber temperature of 700℃. Airborne RCFs were collected during scrubber maintenance, and their characteristics were analyzed using microscopes. Results: The components of bulk RCFs were SiO2 and Al2O3, having an amorphous structure. Airborne RCFs were morphologically different from bulk RCFs in size, which could negatively affect maintenance workers' health. 58% of airborne RCFs correspond to the size of thoracic and respirable fibers. RCFs did not crystallize at high temperatures. The exposure caused by airborne RCFs during the scrubber frame assembly and insulation replacement was higher than the occupational exposure limit. Conclusion: Workers conducting insulation replacement are likely exposed to airborne RCFs above safe exposure limits. As RCFs are suspected carcinogens, this exposure should be minimized through prevention and precautionary procedures.

Alignment Effects for Nematic Liquid Crystal on a New Diamond-like Carbon Layer

  • Seo, Dae-Shik;Jo, Yong-Min;Hwang, Jeoung-Yeon;Lee, Sang-Keuk
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권2호
    • /
    • pp.1-5
    • /
    • 2002
  • Alignment effects for nematic liquid crystal (NLC) and electro-optical (EO) characteristics of the ion beam (IB) aligned twisted nematic (TN)-liquid crystal display (LCD) with oblique ion beam exposure on the diamond-like carbon (DLC) thin film surface were studied. A high pretilt angle of 3.5$^{\circ}$ in NLC by ion beam exposure on the DLC thin film layer can be measured. An excellent voltage-transmittance (V-T) curve of the ion beam aligned TN-LCD was observed with oblique ion beam exposure on the DLC thin film surface for 1 min. Also, a faster response time for the ion beam aligned TN-LCD with oblique ion beam exposure on the DLC thin film surface for 1 min can be achieved.

흡입 노출 모델 알고리즘의 구성과 시나리오 노출량 비교 (Model Algorithms for Estimates of Inhalation Exposure and Comparison between Exposure Estimates from Each Model)

  • 박지훈;윤충식
    • 한국산업보건학회지
    • /
    • 제29권3호
    • /
    • pp.358-367
    • /
    • 2019
  • Objectives: This study aimed to review model algorithms and input parameters applied to some exposure models and to compare the simulated estimates using an exposure scenario from each model. Methods: A total of five exposure models which can estimate inhalation exposure were selected; the Korea Ministry of Environment(KMOE) exposure model, European Centre for Ecotoxicology and Toxicology of Chemicals Targeted Risk Assessment(ECETOC TRA), SprayExpo, and ConsExpo model. Algorithms and input parameters for exposure estimation were reviewed and the exposure scenario was used for comparing the modeled estimates. Results: Algorithms in each model commonly consist of the function combining physicochemical properties, use characteristics, user exposure factors, and environmental factors. The outputs including air concentration ($mg/m^3$) and inhaled dose(mg/kg/day) are estimated applying input parameters with the common factors to the algorithm. In particular, the input parameters needed to estimate are complicated among the models and models need more individual input parameters in addition to common factors. In case of CEM, it can be obtained more detailed exposure estimates separating user's breathing zone(near-field) and those at influencing zone(far-field) by two-box model. The modeled exposure estimates using the exposure scenario were similar between the models; they were ranged from 0.82 to $1.38mg/m^3$ for concentration and from 0.015 to 0.180 mg/kg/day for inhaled dose, respectively. Conclusions: Modeling technique can be used for a useful tool in the process of exposure assessment if the exposure data are scarce, but it is necessary to consider proper input parameters and exposure scenario which can affect the real exposure conditions.

Health Effects of Chronic Arsenic Exposure

  • Hong, Young-Seoub;Song, Ki-Hoon;Chung, Jin-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • 제47권5호
    • /
    • pp.245-252
    • /
    • 2014
  • Arsenic is a unique element with distinct physical characteristics and toxicity whose importance in public health is well recognized. The toxicity of arsenic varies across its different forms. While the carcinogenicity of arsenic has been confirmed, the mechanisms behind the diseases occurring after acute or chronic exposure to arsenic are not well understood. Inorganic arsenic has been confirmed as a human carcinogen that can induce skin, lung, and bladder cancer. There are also reports of its significant association to liver, prostate, and bladder cancer. Recent studies have also suggested a relationship with diabetes, neurological effects, cardiac disorders, and reproductive organs, but further studies are required to confirm these associations. The majority of research to date has examined cancer incidence after a high exposure to high concentrations of arsenic. However, numerous studies have reported various health effects caused by chronic exposure to low concentrations of arsenic. An assessment of the health effects to arsenic exposure has never been performed in the South Korean population; thus, objective estimates of exposure levels are needed. Data should be collected on the biological exposure level for the total arsenic concentration, and individual arsenic concentration by species. In South Korea, we believe that biological exposure assessment should be the first step, followed by regular health effect assessments.

Poly[N-(phenyl)maleimide]계 광폴리머를 이용한 액정배향효과 (Effects of Liquid Crystal Alignment on the Photopolymer based Poly[N-(phenyl)maleimide])

  • 황정연;서대식;김준영;이재호;김태호
    • 한국전기전자재료학회논문지
    • /
    • 제14권10호
    • /
    • pp.845-849
    • /
    • 2001
  • The new phto-alignment material PMI5CA, poly{N-(phenyl)maleimide-co-3-[4-(pentyloxy) cinamate]porpyl-2-hydroxy-1-methacrylate}, was synthesized and the electro-optical (EO)characteristics in the vertical-aligned(VA) liquid crystal display (LCD) photo-aligned on the photopolymer surface were studied. Excellent Voltage-transmittance(V-T) characteristics in the VA-LCD photoaligned with polarized UV exposure of oblique direction on the pohotopolymer surface for 1 min can be achieve. The transmittance of the VA-LCD photoaligned on the photopolymer surface decreased with increasing UV exposure time. We suggest that decrease of transmittance in the VA-LCD photoaligned on the photopolymer surface is attributed to the dissociation of the ester linkage in the photodimerized cinnamate structure with increasing UV exposure time.

  • PDF

패션 의경선도자에 관한 연구 - 주부들의 사회참여도와 대중매체 노출도를 중심으로 - (The study on fashion opinion leader -Concerning the degree of mass media exposure and social paticipation-)

  • 전혜정
    • 대한가정학회지
    • /
    • 제23권3호
    • /
    • pp.39-48
    • /
    • 1985
  • The purpose of this study was to analyze the characteristics of Women's clothing fashion opinion leaders. The fundamental conceptualization for this study was based on the theories of fashion and opinion leader. Data for the study was obtained through questionnaires from 385 houswives of Gang Nam Gu. The measure of fashion opinion leadership applied in this project was the modification of Rogers' six question self-designating method. Operationally, the characteristic under investigation categoried into three sets of variable ; demographic and socialogical variables, and mass media exposure. As to the data analyses for this study, two-way crosstabs analyses were applied in comparing the characteristics of fashion opinion leader with followers. X\sup 2\ test was used to examine the correlation of several variables. RESULTS : 1. Fashion opinion leaders are not differ from followers in demographic characteristics. 2. Compared with followers, fashion opinion leaders are more active in the participation in concerts, movies and plays. 3. In mass media exposure, fashion opinion leaders differ little from followers regarding T.V, radio, newspaper, literarly magazine, general magazine, culture magazine.

  • PDF

경사 증착된 비정질 칼코게나이드 박막에 평광-광유기된 이색성의 이완 및 소거 특성 (The Relaxation and Elimination Characteristics of Polarization-Photoinduced Dichrosim in Obliquely Deposited Amorphous Chalcogenide Thin Films)

  • 박수호;전진영;이현용;정홍배
    • 한국전기전자재료학회논문지
    • /
    • 제11권10호
    • /
    • pp.891-896
    • /
    • 1998
  • The relaxation and elimination characteristics of polarization-photoinduced dichroism have been investigated in amorphous chalcogenide thin films deposited having normal(0。) and obique (80。) vapor incident angles. The dark relaxation kinetics of dichroism from a saturation point(D\ulcorner\ulcorner) to a certain relaxation point(D\ulcorner\ulcorner) grew to be longer on subsequent cycles of switching on and off of the inducing light, and these decays are changed from simple exponential decay to stretched exponential decay. The dichroism induced by a long time(~3.3 hrs) exposure exhibited the characteristics of longer time maintenance and smaller decreasing rate, in contrast with that by a short time (~min) exposure. In addition, the dichroism was eliminated by the exposure of non-polarized He-Ne laser.

  • PDF

Maleimide계 폴리머를 이용한 액정배향특성 (Liquid Crystal Aligning Capabilities on the Photopolymer Based Maleimide)

  • 이윤건;황정연;서대식;김준영;이재호;김태호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.358-361
    • /
    • 2001
  • A new photoalignment material PM15CA, poly{N-(phenyl)maleimide-co-3-[4-(pentyloxy) cinnamate]propyl-2-hydroxy-1-methacrylate}, was synthesized and the electro-optical (EO) characteristics in the vertical-aligned (VA) liquid crystal display (LCD) photo-aligned on the photopolymer surface were studied. Excellent voltage-transmittance(V-T) characteristics in the VA-LCD photoaligned with polarized UV exposure of oblique direction on the pohotopolymer surfaces for 1 min can be achieved. The transmittance of the VA-LCD photoaligned on the photopolymer surface decreased with increasing UV exposure time. We suggest that the decrease of transmittance in the VA-LCD photoaligned on the photopolymer surface is attributed to the dissociation of the ester linkage in the photodimerized cinnamate structure with increasing UV exposure time

  • PDF

소방공무원의 직업적 방사선노출에 대한 지식, 자각 및 건강피해 우려 (Knowledge, Awareness and Health Risk Concerns on Occupational Exposure to Radiation among Firefighters in Korea)

  • 이현경;윤형완;박정임
    • 한국산업보건학회지
    • /
    • 제25권4호
    • /
    • pp.516-524
    • /
    • 2015
  • Objectives: This study aims to investigate the current status of knowledge, awareness and health risk concerns on occupational radiation exposures among firefighters in Korea. The results will provide basic information for developing a prevention program to minimize adverse health effects relating to radiation exposure among firefighters. Methods: A questionnaire was composed of general characteristics of participants, and their knowledge, awareness, health risk concerns relating to occupational radiation exposure. It was distributed by email to all of 307 firefighters in Jeollabukdo in April 2014 and 259 of them (response rate 84.3%) were responded. Answers were analyzed for descriptive statistics including frequencies and percentages. SPSS/WIN 18.0 program was utilized for statistical analysis of t-test, ANOVA and Pearson's correlation. Results: The average score of radiation protection knowledge was $5.83{\pm}1.77$ ($average{\pm}SD$) out of 10. The score of awareness and health risk concerns on radiation exposure were 4.27, 3.94 out of 5, respectively. The results indicated that the knowledge on the characteristics of radiation was marginal among the firefighters, while the awareness and health risk concerns relating to radiation exposures were relatively higher comparing to other professions. Conclusions: Knowing the characteristics of potential risks is the first step for minimizing the adverse health effects relating to the risks. Therefore, it is necessary to provide adequate training and information on radiation and exposure protection methods for firefighters.