• 제목/요약/키워드: exposed aggregate

검색결과 110건 처리시간 0.02초

A Study on the Application of Recycled Fine Aggregate under Sulfate Environment

  • Lee, Seung-Tae
    • 자원리싸이클링
    • /
    • 제16권2호
    • /
    • pp.17-22
    • /
    • 2007
  • The report of an investigation into the performance of mortar specimens made with recycled fine aggregate (RA) exposed to sodium sulfate solution for 360 days is presented in this paper. Mechanical properties of mortar specimens such as visual examination, compressive strength, expansion and mass loss were periodically monitored. From the test results, it was found that mortar specimens with higher replacement levels of Rh exhibited poor performance in sodium sulfate solution. However, compared to mortar specimens without RA, those with lower replacement levels of RA (up to 50% by mass) was more resistant to sulfate attack. Through the x-ray diffraction analysis, it was confirmed that the main products causing sulfate deterioration in RA mortar specimens were the formation of gypsum and thaumasite.

재생골재를 사용한 콘크리트의 초기재령 수축에 관한 연구 (A Study on Early Age Shrinkage of Concrete using Recycled Aggregate)

  • 구봉근;서상구;라재웅;박재성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.159-167
    • /
    • 2003
  • Cracks in reinforced concrete structures reduce overall durability by allowing the penetration of water and aggressive agents, thereby accelerating the deterioration of the reinforcing steel. Highway pavement and bridge decks are especially susceptible to this type of deterioration since these structures exhibit high rates of shrinkage and are frequently exposed to aggressive environmental conditions. The objectives of this investigation included the development of experimental procedures for assessing shrinkage cracking potential of recycled aggregate concrete, the evaluation of mix composition on shrinkage cracking potential, and the development of theoretical models to simulate early-age cracking behavior. Specifically, the influences of shrinkage-reducing admixture(SRA) and recycled aggregate concrete were investigated. The shrinkage-reducing admixture substantially reduces free shrinkage and restrains shrinkage cracking while providing similar mechanical properties. A fracture mechanics modeling approach was developed to predict the behavior of a variety of restrained concrete specimens. This modeling approach was used to successfully explain experimental results from a variety of mixture compositions. The model was used to demonstrate the influence of material and structural properties on the potential for cracking.

3성분계 포졸란재를 이용한 반응성 분체 콘크리트(RPC)의 고온특성 (The mechanical properties of Reactive Powder Concrete using Ternary Pozzolanic Materials exposed to high Temperature)

  • 장칩도르지;소형석;이제방;소승영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.68-71
    • /
    • 2013
  • Reactive Powder Concrete (RPC) is an ultra high strength and high ductility cement-based composite material and has shown some promise as a new generation concrete in construction field. It is characterized by a silica fume-cement mixture with very low water-binder (w/b) ratio and very dense microstructure, which is formed using various powders such as cement, silica fume and very fine quartz sand (0.15~0.4mm) instead of ordinary coarse aggregate. However, the unit weight of cement in RPC is as high as 900~1,000 kg/㎥ due to the use of very fine sand instead of coarse aggregate, and a large volume of relatively expensive silica fume as a high reactivity pozzolan is also used, which is not produced in Korea and thus must be imported. Since the density of RPC has a heavy weight at 2.5~3.0 g/㎤. In this study, the modified RPC was made by the combination of ternary pozzolanic materials such as blast furnace slag and fly ash, silica fume in order to economically and practically feasible for Korea's situation. The fire resistance and structural behavior of the modified RPC exposed to high temperature were investigated.

  • PDF

고온을 받은 콘크리트의 공학적 특성 (The Engineering Properties of Concrete Exposed at High Temperature)

  • 권영진;김용로;장재봉;김무한
    • 한국화재소방학회논문지
    • /
    • 제18권1호
    • /
    • pp.31-36
    • /
    • 2004
  • 본 연구는 잔골재 및 혼화재 종류, W/C에 따른 콘크리트의 폭열성상 및 압축강도 초음파속도 등의 공학적 특성을 검토함으로서 폭열 방지 및 화재 피해를 입은 콘크리트 구조물의 재사용과 보수보강, 안전도평가 등에 기초적인 자료를 제시하고자 한다. 폭열성상을 살펴보면, 잔골재에 따라서는 바다모래를 사용한 경우 폭열이 발생하지 않았거나 약간의 폭열이 나타나는 정도이나 재생잔골재나 부순모래를 사용한 경우에는 폭열이 심하게 나타났다. 또한 혼화재 종류에 따라서는 대체로 유사한 폭열성상을 나타내었다. 한편, W/C 30.5%의 고강도 영역에서는 대부분 폭열하였으나 W/C 55%의 보통강도 영역에서는 대부분 폭열하지 않았다. 잔존 압축강도는 W/C 55%의 경우 평균 45%로 나타났으며, W/C 30.5%의 경우에는 평균 64%로 나타났다. 초음파속도는 잔골재 종류 및 W/C, 가열시간에 따라 다르게 나타났으며, 가열 후 3개월이 가열 후 1개월보다 약 1.3∼8.4%의 초음파속도 회복을 보였다.

Surface microhardness of three thicknesses of mineral trioxide aggregate in different setting conditions

  • Shokouhinejad, Noushin;Jafargholizadeh, Leila;Khoshkhounejad, Mehrfam;Nekoofar, Mohammad Hossein;Raoof, Maryam
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.253-257
    • /
    • 2014
  • Objectives: This study aimed to compare the surface microhardness of mineral trioxide aggregate (MTA) samples having different thicknesses and exposed to human blood from one side and with or without a moist cotton pellet on the other side. Materials and Methods: Ninety cylindrical molds with three heights of 2, 4, and 6 mm were fabricated. In group 1 (dry condition), molds with heights of 2, 4, and 6 mm (10 molds of each) were filled with ProRoot MTA (Dentsply Tulsa Dental), and the upper surface of the material was not exposed to any additional moisture. In groups 2 and 3, a distilled water- or phosphate-buffered saline (PBS)-moistened cotton pellet was placed on the upper side of MTA, respectively. The lower side of the molds in all the groups was in contact with human blood-wetted foams. After 4 day, the Vickers microhardness of the upper surface of MTA was measured. Results: In the dry condition, the 4 and 6 mm-thick MTA samples showed significantly lower microhardness than the 2 mm-thick samples (p = 0.003 and p = 0.001, respectively). However, when a distilled water- or PBS-moistened cotton pellet was placed over the MTA, no significant difference was found between the surface microhardness of samples having the abovementioned three thicknesses of the material (p = 0.210 and p = 0.112, respectively). Conclusions: It could be concluded that a moist cotton pellet must be placed over the 4 to 6 mm-thick MTA for better hydration of the material. However, this might not be necessary when 2 mm-thick MTA is used.

Effect of polypropylene and glass fiber on properties of lightweight concrete exposed to high temperature

  • Abdulnour Ali Jazem Ghanim;Mohamed Amin;Abdullah M. Zeyad;Bassam A. Tayeh;Ibrahim Saad Agwa;Yara Elsakhawy
    • Advances in concrete construction
    • /
    • 제15권3호
    • /
    • pp.179-190
    • /
    • 2023
  • The effect of glass fibres (GF) and polypropylene fibres (PPF) on the fresh properties and mechanical properties of lightweight concrete (LWC) exposed to high temperatures is investigated in this study. In this study, fifteen LWC mixtures were carried out in three different groups reinforced with PPF or GF fibers by 0%, 0.2%, and 0.4% by volume of concrete. The first group included aluminum powder (AP) as an air agent at 0.03% with the normal weight coarse aggregate (NWCA) by 100% of the weight of coarse aggregate. In the second group, 33% of the NWCA weight was replaced by lightweight coarse aggregate (LWCA). In the third group, 67% of the NWCA weight was replaced by LWCA. The slump, unit weight, Compressive strength (CS), tensile strength (TS), and flexural strength (FS) were examined. For two hours, the CS and FS were subjected to elevated temperatures of 200℃, 400℃, and 600℃, in addition to microstructure analysis of concrete. In comparison to the reference mixture, the fresh properties and bulk density of LWC decreased with the use of the air agent or the replacement of 67% of the NWCA with LWCA. As a result of the fiber addition, both the slump test and the bulk density decreased. The addition of fibers increased the CS; the highest CS was 38.5 MPa when 0.4% GF was added, compared to 28.9 MPa for the reference mixture at the test age of 28 days. In addition, flexural and TS increased by 53% and 38%, respectively, for 0.4% GF mixes. As well as, adding 0.4% GF to LWC maintained a higher CS than other mixtures.

Flexural behavior of reinforced recycled aggregates concrete beam after exposed to high temperatures

  • Longshou Qin;Xian Li;Ji Zhou;Ying Liang;Wangsheng Ou;Zongping Chen
    • Structural Engineering and Mechanics
    • /
    • 제87권3호
    • /
    • pp.201-210
    • /
    • 2023
  • This paper investigates the flexural behavior of reinforced recycled aggregates concrete (RRAC) beams after exposed to high temperatures. The experimental results from 17 specimens were present and compared with temperatures, recycled coarse aggregate (RCA) replacement percentages, and concrete strength as variables. It was found that the high temperature would not cause an observable change in the failure pattern. However, high temperature can significantly reduce the stiffness and ductility, and accelerate the damage degradation of specimens. After exposure to 600℃, the ultimate bearing capacity of the specimens decreased by 20%-30% The mechanical properties of RRAC beams after high temperatures were barely impacted by the replacement percentages. Increasing the concrete strength of RCA could effectively improve the bearing capacity and peak deflection of RRAC beams after exposed to high temperatures. Furthermore, the calculation method of the bending bearing capacity and deflection of RRAC beams was also discussed.

GFRP로 보강된 순환골재콘크리트 블록의 성능평가 (Performance Evaluation of Recycled Aggregate Concrete Block Reinforced with GFRP)

  • 김용재;이현기;박철우;심종성
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6565-6574
    • /
    • 2013
  • 세굴방지, 하천사면보호, 하상구조물보호 등을 위해 국내에서는 프리캐스트 콘크리트 블록이 주로 사용되고 있다. 그러나 이러한 콘크리트 블록은 항상 물 또는 습윤한 환경에 접하게 되므로 내부보강재로 사용된 철근에 부식이 발생될 확률이 높으며 이로 인해 블록의 성능과 내구성이 크게 감소될 수 있다. 따라서 본 연구에서는 내부보강재를 GFRP 보강근으로 대체하여 철근부식에 따른 성능저하문제를 근본적으로 해결하고자 하였으며, 콘크리트 블록에 사용되는 콘크리트에는 순환골재와 조강시멘트를 적용하여 현장적용성을 높이고자 하였다. 실험결과 조강시멘트를 사용한 순환골재콘크리트는 기존 콘크리트에 비해 작업성과 탈형강도는 유사하였으며, 재령 28일 압축강도는 약 18% 증가되었다. 하중저항성능을 측정한 결과, GFRP 보강근이 적용된 순환골재콘크리트 블록은 기존 콘크리트 블록에 비해 약 10~30%의 하중저항성능이 향상되는 것으로 측정되었다.

재생잔골재를 활용한 화재피해를 입은 콘크리트의 공학적 특성에 관한 실험적 연구 (An Experimental Study on the Engineering Properties of Deteriorated Concrete using Recycled Fine Aggregate by Fire Damage)

  • 권영진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.190-196
    • /
    • 2006
  • 기존 연구에서 살펴보면, 철근콘크리트구조물에 발생한 화재로 인해 경화된 시멘트 페이스트와 골재의 수축과 팽창의 차이에 따라 조직이 와해되고, 열응력에 의해 균열이 발생하여 내구성이 저하한다. 그래서 성능저하의 정확한 진단은 일반적인 콘크리트구조물에서 방화성능저하의 매커니즘에 관한 기초가 요구되며, 고온에 노출된 콘크리트의 특성에 대한 기초 정보와 데이터는 성능저하의 정확한 진단을 위해 필요하다. 따라서, 본 연구는 다양한 콘크리트 시험체를 제작하여, 고온 환경에서 노출시켜, 폭열을 관찰하고, 공학적인 특성을 평가함으로서 화재피해를 입은 콘크리트구조물 성능저하의 빠르고 정확한 진단을 위한 기초적인 데이터를 제공하고자 한다.