• Title/Summary/Keyword: expose dose

Search Result 33, Processing Time 0.024 seconds

A Comparision of the Radiation dose by Distance and the Direction according to a Tube Position of the C-arm Unit (C-arm의 Tube 위치에 따른 거리 및 방향별 피폭선량 비교)

  • Kim, Jin-Su;Woo, Bong-Cheol;Kim, Sung-Jin;Lee, Kwan-Sup;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • In operation room, the use of the C-arm unit is increasing. So, the radiation dose of the person who work in operation room was even more increased than before. Thus, this study is shown the measurement of expose dose and the way for decrease of the radiation dose by using the C-arm unit. The experiment was performed with the C-arm unit and used a phantom which is similar to tissue of the human body and fluoro-glass dosimeter for dose measurement. The expose dose were measured by the tube position(over tube, under tube) of the C-arm unit, distance(50, 100$\sim$200cm), direction(I, II, III, IV), runtime(1min, 3min), wearing of the apron. The radiation dose was decreased twice and three times at under tube rather than over tube. The I direction was measured 20$\sim$30% more than the others. The biggest expose dose is 50cm from center on distance. The expose dose is decreased to far from center. In case of Wearing of the apron, the radiation dose was decreased 60$\sim$90% by the distance. But there weren't change of the radiation dose by C-arm tube position. In present, by increasing the usage of the C-arm unit, the radiation dose is inevitable. So, this study recommends us to use the under tube of the C-arm unit. Also, Wearing of the apron is required for minimum of the radiation exposure.

  • PDF

Research about the absorbed dose with speculum material-related in Hysterosalpingography (자궁난관 조영술 검사 시 Speculum 재질에 따른 흡수선량의 변화에 관한 연구)

  • Kim, Yun-Min
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • The purpose of our study was to determine the entrance surface dose and absorbed dose in ovary when using the metal speculum and plastic speculum in hysterosalpingography respectively. The examinations was performed in anthropomorphic phantom into which calibrated photoluminescence glass dosimeter were placed on symphysis pubis level surface and ovary area. We checked average fluoroscopy time and spot expose times during the hysterosalpingography. It was average fluoroscopy time 58 sec, spot expose 5 times. We divided the subjects into two different groups to used metal and plastic speculum. We measured 10 times of absorbed dose in the same condition of the anthropomorphic phantom. We compared two groups adsorbed dose on ovary with speculum material-related. The entrance surface dose on of plastic Speculum using group was average 17.23 mGy, absorbed dose on ovary was average 3.51 mGy. The entrance surface dose on ovary of metal Speculum using group was average 19.95 mGy, absorbed dose on ovary was average 4.14 mGy. Plastic speculum using group shows a decrease absorbed dose(17.9%) as compared with metal speculum using group. The method of plastic speculum using in hysterosalpingography. might provide us with lower radiation dose, especially in patients with childbearing stage.

  • PDF

The Evaluation of External Radiation Exposure dose rate for Radium-223 Dichloride (Radium-223 Dichloride의 외부 방사선량의 평가)

  • Cho, Seong Wook;Yoon, Seok Hwan;Seung, Jong Min;Kim, Tae Yub;Im, Jeong Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.28-31
    • /
    • 2016
  • Purpose $^{223}Ra-Dichloride$ is used for the medicine of castration-resistant prostate cancer (CRPC) and which emits ${\alpha}-ray$ of 28 Mev that is used for therapy. However $^{223}Ra-Dichloride$ emits ${\beta}-ray$ of 3.6% and ${\gamma}-ray$ of 1.1%(80,156,270 keV) aside from ${\alpha}-ray$ in decay. Therefore we would like to evaluate external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$. Materials and Methods We calculated external radiation expose dose rate using ${\gamma}-constant$ of $^{223}Ra-Dichloride$, $^{99m}Tc$ based on Health physics(2012). $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq were applied. external radiation expose dose rate 15 times from 1m by survey meter. Results ${\gamma}-contant$ of $^{223}Ra$, $^{99m}Tc-MDP$ from 1m distance based on Health physics(2012) is 0.0469, 0.0215. calculated value of external radiation expose dose rate was $16{\mu}Sy$, $34{\mu}Sy$ which activity is $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq from 1 m and measured mean value of 1 m was $0.7{\mu}Sy/h$, $18{\mu}Sy/h$. Conclusion ${\gamma}-constant$ of $^{223}Ra$ is higher than $^{99m}Tc$ based on Health physics(2012). however calculated maximum external radiation expose dose rate of $^{223}Ra-Dichloride$ is lower than $^{99m}Tc$ due to actually used quantity of activity of $^{223}Ra-Dichloride$ is small. measured value of $^{223}Ra-Dichloride$ is also lower than $^{99m}Tc-MDP$. Therefore external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$ is very low.

  • PDF

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

Inhalation Toxicity Study of H Menthol (Nicotine Free-Tobacco Free) Herbal Cigarettes (H Menthol (Nicotine Free-Tobacco Free) Herbal Cigarette의 흡입독성시험)

  • 강경선;조성대;조종호;김경배;이지해;안남식;정지원;양세란;박준석
    • Environmental Mutagens and Carcinogens
    • /
    • v.22 no.2
    • /
    • pp.97-105
    • /
    • 2002
  • Nowadays a huge variety of products that aim to assist to quit smoking or reduce addictive symptoms are developed and manufactured with safety evaluation, but the safety of the most recent products of interest which do not contain tobacco and nicotine, and shape cigarettes is not evaluated and guaranteed relatively. This study was carried out to evaluate the single and repeated dose inhalation toxicity and genotoxicity of H menthol (Nicotine free-tobacco free) herbal cigarettes provided by Cigastop Ltd. in ICR mice. In this study, doses which we determined to expose to mice were 40 cigarettes for 6 hours a day to mice in single dose and 20 (high dose), 10 (middle dose) and 5 cigarettes (low dose) a day for 28 days in repeated dose inhalation toxicity, in vivo chromosome aberration test and micronucleus test. The particulate substances from H menthol herbal cigarettes also were gathered and used in the Salmonella typhimurium/microsome assay (Salmonella test; Ames test). We could find neither significant changes between control and treatment groups nor dose-response effects of test material at all except serum Ca level of female middle dose treatment group in repeated dose inhalation toxicity test. In conclusion, H menthol herbal cigarettes, when applied clinically intended dose we used, might not show any toxic and/or mutagenic effect.

  • PDF

Research on the Actual Condition of Mammograpgy and Space Scattered Dose in Mammography Room (유방촬영의 실태와 유방촬영실의 공간산란선량에 관한 조사 연구)

  • Lee, In-Ja;Park, Kye-Yeon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • I made inquires about mammographic equipments and circumstances of mammography rooms in the 64 medical facilities in areas of Seoul and Kyong Gi Do. Moreover I had experments about exposure dose with patients and radiologic technologists. so there is the data indicated follows. 1. There are inclined to improve in quality and function of mammographic equipments, it has been proven that s/f system exchanged to DR system. 2. It is certain that the number of examinations are becoming increasingly significant. 3. The Space Scattered Dose of mammography rooms are much more larger than portable equipments. 4. I worry about the affection of expose dose about Space Scattered Dose of mammography room. 5. There is need of study how to cope with the situation about increasing exposure dose of radiologic technologists in small space and numeruous number of examinations.

  • PDF

Novel polyvinyl alcohol film dosimeter containing 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide dye for high dose application

  • Khalid A. Rabaeh;Ahmed A. Basfar;Issra' M.E. Hammoudeh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3383-3387
    • /
    • 2023
  • A new dyed polyvinyl alcohol (PVA) film dosimeter based on 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MMT) tetrazolium dye is proposed in this study for measuring high gamma radiation dose. Gamma cell irradiator that contains Co-60 gamma-ray source was used to expose the novel MMT-PVA films to different doses up to 25 kGy. The changed in optical property of irradiated and unirradiated films were characterized by UV-Vis spectrophotometer. The results show that the dose sensitive and the linear range of irradiated films were increased considerably with increase of MMT concentration from 1 to 5 mM. The dose response of dyed PVA film changed substantially with changing relative humidity (12-74%) as well as irradiation temperature (10-40 ℃). The absorbance of the unirradiated films does not change up to 10 days in dark while a significant increase in their absorbance was reported for similar films under fluorescent light. The irradiated dosimeters that kept in dark showed a perfect stability for 54 days. It was found that no obvious impact of dose rate on the irradiated MMT-PVA film dosimeters.

Patient Exposure Dose Reduction in Coronary Angiography & Intervention (심혈관조영술 및 중재술 시 환자 선량 감소방안)

  • Lim, Do-Hyung;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.69-76
    • /
    • 2022
  • This study, the method of reducing the exposure dose by changing the geometrical requirements among the preceding studies and the method of directly wearing a protector on the patient were used to expose the patient. A comparative experiment was conducted on the method of reducing the dose and the most effective method for reducing the exposure dose was investigated. Using the phantom, the dose of the lens, thyroid gland, and gonad gland in the 5 views most used in coronary angiography and intervention accumulated 5 times for 10 seconds at 60~70 kV, 200~250 mA as an automatic controller of the angiography system, and measured by Optically Stimulated Luminescent Dosimeter(OSLD). SID 100 cm and Cine 15 f/s as a control group the experiment was conducted by dividing the experimental group into 3 groups: a group lowered to Cine 7.5 f/s, a phantom protector, and a group lowered to 95 cm SID. As a result of the experiment, showing decrease in exposure dose compared to the control group. Lowering the cine frame may be the simplest and most effective method to reduce the exposure dose, but there is a limit that it cannot be applied if the operator judges that the diagnostic value is small or feels uncomfortable with the procedure. Conclusion as fallow reducing the exposure dose by directly wearing protector is the next best solution, and it is hoped that the conclusions obtained through this study will help reduce the exposure dose to unnecessary organ.

Effect of Each Constituent-Herb of Sagoonja-Tang on the Change of Corticosterone Level induced by Cold Stress in Mice (Cold Stress로 유발된 생쥐의 혈중 corticosterone 농도변화에 대한 사군자탕(四君子湯) 구성약물의 효능)

  • Kwon Yong-Uk;Lee Tae-Hee
    • Herbal Formula Science
    • /
    • v.11 no.2
    • /
    • pp.83-94
    • /
    • 2003
  • This study aimed to investigate the effects of each constituent-herb of Sagoonja- Tang on the plasma corticosterone level in mice exposed to cold stress. Sagoonja-Tang is composed of Ginseng Radix, Atractylodis Radix, Poria, and Glycyrrhizae Radix. Each constisuent-herb(0.5g/kg, 1.0g/kg) was administered intragastrically to mice 1hr prior to expose to forced cold water swimming($4{\circ}C$, 3min) before measuring the change of plasma corticosterone level of mice. The results were as follows: 1. At 30 minutes after the cold stress for 3 minutes the most significant increase of corticosterone level was shown. 2. Ginseng group(PGR group) didn't show any significant changes. 3. Atractylodis group(AR group) showed significant decrease at 0.5g/kg dose (P<0.01). But it didn't show significant changes at 1.0g/kg dose. 4. Poria group(P group) didn't show significant changes. But it showed slightly increase at 1.0g/kg dose. 5. Glycyrrhizae group(GR group) didn't show significant changes. These data revealed that Atractylodis macrocephalae Rhizoma might have the anti-stress effect through the control of plasma corticosterone level and the dose of herbs had a different effect on the plasma corticosterone level in mice exposed to cold stress.

  • PDF

Exposure dose Reduction using Pb Banding of own manufacturing (자체제작 Pb 밴딩을 이용한 피폭선량 감소)

  • Kim, Chang-Gyu
    • Journal of Digital Convergence
    • /
    • v.11 no.6
    • /
    • pp.269-273
    • /
    • 2013
  • Exposure dose to the examinee was measured using glass dosimeter in the test using panorama device at the time of dental treatment. As a result of measuring expose dose to lens according to the different sizes of Pb banding of own manufacturing to reduce exposure dose to lens especially sensitive to radiation, it was verified that exposure dose to lens varied depending on the size of the Pb banding. With the size of Pb banding of $3{\times}20{\times}0.2cm$, exposure dose tended to increase higher than normal value, and with the size of or more than $5{\times}20{\times}0.2cm$, it decreased. And also, the obtained image with the size of $7{\times}20{\times}0.2cm$ was not suitable for diagnosis. Therefore, it is expected that exposure dose would be reduced by using Pb banding of the size of not less than $5{\times}20{\times}0.2cm$ and not more than $6{\times}20{\times}0.2cm$ in the test, to minimize exposure dose and conduct panorama test efficiently.