• Title/Summary/Keyword: exponential constant wave (iExp)

Search Result 1, Processing Time 0.017 seconds

A Study on the Telescopic Cascode Comparator in SET Situation (SET 상황에서 텔레스코픽 캐스코드 비교기에 관한 연구)

  • Jang, Jae-Seok;Chung, Jae-Pil;Park, Jung-Cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.4
    • /
    • pp.277-282
    • /
    • 2020
  • This study was initiated to find a way to resolve electronic equipment as it could be affected by multiple environments. The effect of setting the exponential constant wave (iExp) in the telescopic cascade comparator to the SET (Single Event Transient) environment was tested. In this paper, the radio wave delay was measured at 0.46 ㎲ and the gain at 0.713 in the telescopic cascade comparator without setting the SET situation. FET T0 (M6) was measured to have a large spike at 11㎲ to 15㎲ in the telescopic cascade comparator entering the SET situation. FET T1 (M5) has shorted output signals from 10 ㎲ to 16 ㎲. FET T2 (M3) represented a shorted output signal, and FET T3 (M4) measured the output waveform in the form of a large spike waveform. The FET T4 (M1) and FET T5 (M2) are spiky signals. And at all FETs, the propagation delay was changed from 0.45㎲ to 0.54㎲. In summary, The FET element in the telescopic cascade comparator in SET situation was measured to be greatly affected.