• Title/Summary/Keyword: experimental test

Search Result 18,740, Processing Time 0.057 seconds

Establishment of Choline Analysis in Infant Formulas and Follow-up Formulas by Ion Chromatograph (이온크로마토그래프를 이용한 조제유류 및 영아용·성장기용 조제식 중 콜린 함량 분석법 연구)

  • Hwang, Kyung Mi;Ham, Hyeon Suk;Lee, Hwa Jung;Kang, Yoon Jung;Yoon, Hae Seong;Hong, Jin Hwan;Lee, Hyoun Young;Kim, Cheon Hoe;Oh, Keum Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.411-417
    • /
    • 2017
  • This study was conducted to establish the analysis method for the contents of choline in infant formulas and follow-up formulas by ion chromatograph (IC). To optimize the method, we compared several conditions for extraction, purification and instrumental measurement using spiked samples and certified reference material (CRM; NIST SRM 1849a) as test materials. IC method for choline was established using Ion Pac CG column and 18 mM $H_2SO_4$ mobile phase. The parameters of validation were specificity, linearity, LOD, LOQ, recovery, accuracy, precision and repeatability. The specificity was confirmed by the retention time and the linearity, $R_2$ was over 0.999 in range of 0.5~10 mg/L. The detection limit and quantification limit were 0.14, 0.43 mg/L. The accuracy and precision of this method using CRM were 95%, 2.1% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested products were acceptable contents of choline compared with component specification for nutrition labeling. The standard operating procedures were prepared for choline to provide experimental information and to strengthen the management of nutrient in infant formula and follow-up formula.

The Design of Wireless Underwater Telephone -Analysis of Underwater Background Noise for Wireless Underwater Telephone Design - (수중 무선 전화기의 설계 - 수중무선전화기 설계를 위한 수중소음분석을 중심으로-)

  • 박문갑;윤갑동;김석제;윤종락
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.302-307
    • /
    • 2001
  • The underwater background noise measured in Geoje and Tongyoung diving fishing ground from May to December, 2000 and analyzed to get optimum carrier frequency and transmitter power level for underwater wireless telephone design. The results obtained are summarized as follows: 1. At the Geoje and Tongyoung diving fishing ground, the lowest ambient noise band was 25~30kHz with 57dB and 52dB re 1$\mu$Pa, respectively. 2. At the Geoje and Tongyoung diving fishing ground, the lowest noise band during fishing activity was 67dB and 62dB re 1$\mu$Pa, respectively. 3. At the Geoje diving fishing ground, the noise of water jetter which is a digging machine for subbottom shells was 102dB re 1$\mu$Pa. 4. Considering the design parameters of underwater wireless telephone, it is found that the optimum carrier frequency band is around 30kHz and the transmitter source level should be at least 131dB re 1$\mu$Pa for 500m range telephone.

  • PDF

MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING (Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교)

  • Kang, Suk-Ho;Kim, Oh-Young;Oh, Myung-Hwan;Cho, Byeong-Hoon;Um, Chung-Moon;Kwon, Hyuk-Choon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).

ANTIMICROBIAL EFFECT OF ANTIBIOTICS AND ROOT CANAL CEMENTS ON THE PREDOMINANT PATHOGENIC ANAEROBIC MICROFLORA IN ROOT CANALS (근관내 주요 혐기성 병인균에 대한 수종 항생제와 근관충전용 세멘트의 항균효과에 관한 연구)

  • Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.515-525
    • /
    • 1993
  • The purpose of this study was to evaluate the susceptibility of anaerobic microorganisms to certain antibiotics and root canal cements. Prevotella intermedia(Bacteroides intermedius) ATCC 25611(serotype A), Fusobacterium nucleatum ATCC 25586, Actinomyces viscosus ATCC 15987 which are the predominant pathogenic anaerobes in dental root canals were cultured in BHI for 48 hours(Fig.1). After each $200{\mu}l$ of those broths with microorganisms was streaked on each surface of blood agar plate, 2 to 5 antibiotic discs which are impregnated with Tetrncycline, Erythromycin, Ampicillin, Clindamycin, or Vancomycin were applied on each surface of blood agar plate and cultured for 5 days anaerobically in the anaerobic chamber (Fig.2). 15 antibiotic discs for each kind of antibiotics and each species of microorganisms were tested. Also each kind of root canal cement tubes which include Zinc oxide eugenol cement, Zinc phosphate cement, Calcium hydroxide powder+DD.W., Calcium hydroxide paste(Pulpdent Tempcanal), or Vitapex(Table 1) were applied on the inoculated BAPs after $200{\mu}l$ of each experimental species of microorganisms was streaked on the surface of blood agar plates, and they were cultured for 5 days anaerobically in the anaerobic chamber(Fig.3). The sensitivity(antimicrobial effect) was determined by the diameter of the inhibition zone. The results are as follows: 1. The results of antibiotic susceptibility test(Table 2) 1) All of the tested antibiotics had antimicrobial activity with various degrees. 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Erythromycin($37.87mm{\pm}2.20$) was largest, those to Tetracycline($26.20mm{\pm}2.96$), Vancomycin($21.53mm{\pm}1.96$), Clindamycin($18.73mm{\pm}0.96$) was smaller than former orderly, and That to Ampicillin ($7.87mm{\pm}0.83$) was smallest. 3) In Actinomyces viscosus, the diameter of inhibition zone to Erythromycin($28.73mm{\pm}1.22$) was largest, those to Ampicillin($21.73mm{\pm}1.03$), Clindamycin($21.33mm{\pm}1.59$) was similarly next order, that to Vancomycin($19.00mm{\pm}1.96$) was smaller than Clindamycin, and that to Tetracycline($11.93mm{\pm}0.70$) was smallest. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Ampicillin($31.07mm{\pm}1.91$) was largest, that to Erythromycin($28.87mm{\pm}0.92$), Clindamycin($20.47mm{\pm}1.51$), Vancomycin ($16.73mm{\pm}0.96$), Tetracycline ($12.13mm{\pm}1.06$) are smaller than former orderly. 2. The results of root canal cements and pastes(Table 3) 1) The external diameter of tube is 4mm, so 4mm of the inhibition zone diameter means non-susceptable. Prevotella intermedia (old Bacteroides intermedius) was non-susceptable to Calcium hydroxide powder+D.D.W., Calcium hydroxide paste(pulpdent Tempcanal), and Actinomyces viscosus was non-susceptable to Zinc phosphate cement, Calcium hydroxide powder + D.D.W., Calcium hydroxide paste(pulpdent Tempcanal). 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Zinc oxide eugenol cement($13.67mm{\pm}3.30$) was largest, that to Vitapex($9.20mm{\pm}2.96$), Zinc phosphate cement($6.13mm{\pm}2.07$) was smaller than former. 3) In Actinomyces viscosus, the diameter of inhibition zone to Zinc oxide eugenol cement($17.40mm{\pm}5.20$) was largest and that to Vitapex($8.80mm{\pm}1.70$) was next order. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Vitapex($42.33mm{\pm}17.2$) was largest and those to Calcium hydroxide paste(Pulpdent Tempcanal)($14.47mm{\pm}3.72$) and Zinc oxide eugenol cement($8.93mm{\pm}2.71$), Zinc phosphate cement($8.20mm{\pm}2.27$), Calcium hydroxide powder+D.D.W.($5.53mm{\pm}2.10$)was next orderly. And then In Zinc oxide eugenol cement and Zinc phosphate cement group, two of fifteen samples showed no inhibition zone, in Calcium hydroxide powder + D.D.W. group, 8 of 15 samples showed no inhibition zone.

  • PDF

The Effect of Surface Defects on the Cyclic Fatigue Fracture of HEROShaper Ni-Ti rotary files in a Dynamic Model: A Fractographic Analysis (Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할)

  • Lee, Jung-Kyu;Kim, Eui-Sung;Kang, Myoung-Whai;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • This in vitro study examined the effect of surface defects on cutting blades on the extent of the cyclic fatigue fracture of HEROShaper Ni-Ti rotary files using fractographic analysis of the fractured surfaces. A total of 45 HEROShaper (MicroMega) Ni-Ti rotary flies with a #30/.04 taper were divided into three groups of 15 each. Group 1 contained new HEROShapers without any surface defects. Group 2 contained HEROShapers with manufacturing defects such as metal rollover and machining marks. Croup 3 contained HEROShapers that had been clinically used for the canal preparation of 4-6 molars A fatigue-testing device was designed to allow cyclic tension and compressive stress on the tip of the instrument whilst maintaining similar conditions to those experienced in a clinic. The level of fatigue fracture time was measured using a computer connected the system. Statistical analysis was performed using a Tukey's test. Scanning electron microscopy (SEM) was used for fractographic analysis of the fractured surfaces. The fatigue fracture time between groups 1 and 2, and between groups 1 and 3 was significantly different (p<0.05) but there was no significant difference between groups 2 and 3 (p>0.05). A low magnification SEM views show brittle fracture as the main initial failure mode At higher magnification, the brittle fracture region showed clusters of fatigue striations and a large number of secondary cracks. These fractures typically led to a central region of catastrophic ductile failure. Qualitatively, the ductile fracture region was characterized by the formation of microvoids and dimpling. The fractured surfaces of the HEROShapers in groups 2 and 3 were always associated with pre-existing surface defects. Typically, the fractured surface in the brittle fracture region showed evidence of cleavage (transgranular) facets across the grains, as well as intergranular facets along the grain boundaries. These results show that surface defects on cutting blades of Ni-Ti rotary files might be the preferred sites for the origin of fatigue fracture under experimental conditions. Furthermore this work demonstrates the utility of fractography in evaluating the failure of Ni-Ti rotary flies.

Data Mining Approaches for DDoS Attack Detection (분산 서비스거부 공격 탐지를 위한 데이터 마이닝 기법)

  • Kim, Mi-Hui;Na, Hyun-Jung;Chae, Ki-Joon;Bang, Hyo-Chan;Na, Jung-Chan
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.3
    • /
    • pp.279-290
    • /
    • 2005
  • Recently, as the serious damage caused by DDoS attacks increases, the rapid detection and the proper response mechanisms are urgent. However, existing security mechanisms do not effectively defend against these attacks, or the defense capability of some mechanisms is only limited to specific DDoS attacks. In this paper, we propose a detection architecture against DDoS attack using data mining technology that can classify the latest types of DDoS attack, and can detect the modification of existing attacks as well as the novel attacks. This architecture consists of a Misuse Detection Module modeling to classify the existing attacks, and an Anomaly Detection Module modeling to detect the novel attacks. And it utilizes the off-line generated models in order to detect the DDoS attack using the real-time traffic. We gathered the NetFlow data generated at an access router of our network in order to model the real network traffic and test it. The NetFlow provides the useful flow-based statistical information without tremendous preprocessing. Also, we mounted the well-known DDoS attack tools to gather the attack traffic. And then, our experimental results show that our approach can provide the outstanding performance against existing attacks, and provide the possibility of detection against the novel attack.

Varietal Differences in Days Required to Leaf Expansion, Leaf Number on Main Culm, and Days to Heading of Rice under Cold Water Flow System (찬물 흘려대기 논의 수온 분포에 따른 벼의 엽 전개 일수 및 주간엽수와 출수일수의 품종간 차이)

  • 윤성호;윤종선;유길림;박창기;정근식
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.36 no.3
    • /
    • pp.214-219
    • /
    • 1991
  • To clarify the relationship between ambient water temperature and heading characteristics of rice (Oryza sativa L.), twelve of varieties rice were grown in a cold tolerance screening field where water temperature was controlled by continuous cold water irrigation system to test the cold tolerance of rice. When cold water was continuously irrigated with 5 cm of water depth, the water had stagnated for about three hours, and the water temperature increased gradually from inlet toward outlet in the experimental plot. The fluctuation of water temperature was well synchronized with that of ambient air temperature, and the water temperature near outlet became higher than the air temperature at the vegetative phase, while became lower at the reproductive phase of rice plant community. The leaf development rates on main culm increased by increased water temperature. The rice varities, Fukuhikari, Sangpungbyeo and YR3486-16-2 were more sensitive than the others in the response of leaf development to water temperature. However, Janack and Milyang 42 were comparatively less sensitive to water temperature in leaf development. Janack and Paro -white rices required longer days to develop one leaf on main culm at reproductive phase than at vegetative phase. Varietal difference in days required to develop one leaf on main culm of rice plant was more distinctive at the reproductive phase when water temperature was relatively lower than at the vegetative phase with relatively higher water temperature condition. No difference was found between the growth phases, vegetative and reproductive, in the response of average leaf developmental rates to water temperature under the similar air temperature condition. The estimated average days required to develop one leaf on main culm decreased by 1.3 day by 1$^{\circ}C$ increase in water temperature. Varietal differences in the total number of leaves on main culm depended upon the water temperature, in which the varieties such as Fukuhikari, Gwangmyeon-gbyeo, China 988, and YR3486-16-2 showed increased one leaf by increased water temperature, while Sobaekbyeo, Paro-white, Sangpungbyeo, Pungsanbyeo, Samgangbyeo, and Milyang 42 were kept at the same leaf number regardless of water temperature. However, the total leaf number on main culm and days to heading of Janack increased by increased water temperature. The other varieties showed the shortened days to heading by the increase in water temperature with noticeable varietal differences regardless of the variation in the total number of leaves on main culm.

  • PDF

The Electrochemical Chlorination for Marine Plankton Community Disinfection (해양 플랑크톤 군집의 전기분해 염소소독 효과)

  • Kang, Jung-Hoon;Shin, Kyoung-Soon;Hyun, Bong-Gil;Jang, Min-Chul;Kim, Eun-Chan;Chang, Man
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.127-137
    • /
    • 2007
  • To confirm whether or not the Electrochemical Disinfection System (EDS) meet with the D-2 regulation established by IMO (International Maritime Organization), the biological treatment efficacy of the EDS was assessed using three groups of natural marine plankton (bacteria, $10-50\;{\mu}m$ and $>50\;{\mu}m$ sized organisms). Influent water was passed through the EDS under the flow velocity ($23.8\;m^3/hr$) and test design was consisted of control (no treatment) and experimental (10 ppm and 30 ppm) condition for total residual chlorine (TRC). And the biological condition of the influent water followed the standards established by the guidelines for the approval of ballast water management systems. The disinfection efficacy of the $10-50\;{\mu}m$ sized organisms (phytoplankton) was assessed by three kinds of measurements using photomicroscope, epifluorescence microscope and fluorometer (fumer Designs 10-AU). After being passed through the EDS, all motile phytoplankton lost their motility under photomicroscope, the colour of chlorophyll fluorescence fumed from red into green under epifluorescence, and the high chlorophyll fluorescence (Expt. 1: 6.95, Expt. 2: 7.11) detected by fluorometer decreased into value not detected. These results indicated phytoplankton community was totally killed after electrochemical disinfection treatment. Survivorship of the larger organisms than $50\;{\mu}m$ was determined based on the appendage's movement under a stereomicroscope. Natural assemblage collected from ambient seawater was killed shortly after being passed through the EDS, whereas some Artemia remained alive. However, no live Artemia was found after 24 hour further exposure to each TRC concentration (10 and 30 ppm) under darkness. After electrochemical treatment, the target bacteria such as aerobes, coliform and Escherichia coli were completely killed on the basis of CFU (colony forming unit) on Petrifilm plate ($3\;M^{TM}$) after 48 hr incubation. Moreover, no regrowth was found in the three groups of plankton during five days under additional exposure to the treated water. These results indicated that the disinfection efficiency of the EDS on the three groups of plankton satisfy D-2 regulation.

  • PDF

Effect of Feeding Cordyceps with Fly Pupa on Growth Performance in Broiler Chickens (브로일러의 성장에 관한 파리번데기 동충하초 급여효과)

  • Park, Byung-Sung
    • Journal of Life Science
    • /
    • v.21 no.11
    • /
    • pp.1541-1548
    • /
    • 2011
  • This study was carried out to evaluate the effects of the addition of different levels of CFP (Cordyceps with fly pupa) on growth performance in broiler chickens. 400 broiler chicks (Ross 308, 1 day old) were sorted randomly into 4 treatment groups and fed experimental diets for 35 days. The treatment groups were divided into a control group not fed with CFP (T1), and treatment groups fed with CFP 2.0% (T2), CFP 3.5% (T3), and CFP 5.0% (T4). Although the broilers' weight gain and feed efficiency were significantly higher (p<0.05) in the T3 group throughout the entirety of the test period, no statistically significant differences were noted among the T1 and T2, T4 groups. Triglyceride in the blood, total cholesterol, and LDL-C were significantly lower in the CFP treatment groups than in the control group (p<0.05). The blood lipid reduction rate ranged from 5.32 to 10.63% for triglycerides, from 9.23 to 12.62% for total cholesterol, and from 44.67 to 53.81% for LDL-C in the CFP treatment groups relative to the control group. The abdominal fat weight ratio was reduced significantly in the CFP treatment groups (p<0.05) compared with the control group, with a reduction rate range of 17.67-21.68%. Broiler carcass weight, carcass rate, and ratios of breast muscle, skin and thigh muscle weights to carcass weight were significantly higher in the T3 group, and statistically significant differences were noted among the T1 and T2, T4 groups (p<0.05). Enteropathogenic E.coli and Salmonella were lower in the CFP treatment groups than in the control group, whereas the beneficial bacteria Bifidobacteria were significantly higher in the CFP treatment groups than in the control group (p<0.05). These findings suggest that the Cordyceps with fly pupa can improve the carcass characteristics and body weight gain in broiler chickens.

An experimental study of the strength and internal structure of solder joint of fixed partial denture (가공의치(架工義齒) 납착부(蠟着部)의 강도(强度)와 내부구조(內部構造)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Sang-Nam;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.39-59
    • /
    • 1985
  • The purpose of this study was to investigate how gap distances of 0.13mm, 0.15mm, 0.20mm, and 0.30mm affects solder joint strength from gold alloys and nickel-chromium base alloys and to examine the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys. The tensile test specimens were prepared in the split stainless steel mold with a half dumbbell shape 2.5mm in diameter and l2mm in length. 6 pairs of specimens of each gap distance group of gold alloys and nickel-chromium base alloys were made and 48 pairs of all specimens were soldered with solder gold of 666 fineness. All soldered specimens were machined to a uniform diameter and then a tensile load was applied at a cross-head speed of 0.10mm/min using Instron Universal Testing Machine, Model 1115. The fractured specimens at solder gold of solder joint fracture with each gap distance of 0.13mm, 0.15mm, 0.20mm, and 0.30mm were examined under the Scanning Electron Microscope, JSM-35c and the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys was analyzed by Electron Probe Micro Analyzer. The results of this study were obtained as follows: 1. In case of soldering of gold alloys, the tensile strength between gold alloys showed $37.33{\pm}2.52kg/mm^2$ at 0.13, $39.14{\pm}3.35kg/mm^2$ at 0.15mm, $43.76{\pm}2.97kg/mm^2$ at 0.20mm, and $49.18{\pm}4.60kg/mm^2$ at 0.30mm. There was statistically significant difference at each gap distance, and so the greater increase of gap distance showed the greater tensile strength. 2. In case of soldering of nickel-chromium base alloys, the tensile strength between nickel-chromium base alloys showed $34.84{\pm}4.26kg/mm^2$ at 0.13mm, $37.25{\pm}2.49kg/mm^2$ at 0.15mm, $42.91{\pm}4.32kg/mm^2$ at 0.20mm, and $46.93{\pm}4.21kg/mm^2$ at 0.30mm. There was not statistically significant difference only between 0.13mm and 0.15mm and bet ween 0.20 mm and 0.30mm, but generally the greater increase of gap distance showed the greater tensile strength. 3. The greater increase of gap distance shoed less porosities in solder gold at solder joint fracture. 4. In solder gold Au, Cu, Ag, Zn, and Sn were composed and Au and Cu were mostly distributed uniformly. 5. In solder joints of solder gold and gold alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Au, Cu, Ag, Pt, and Pd were composed in gold alloys. Au and Cu of solder gold and gold alloys were mostly distributed uniformly and the diffusion of other elements except Pt and Pd around the solder joint was not almost found. In solder joints of solder gold and nickel-chromium base alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Ni, Cr, and Al were composed in nickel-chromium base alloys. Au and Cu of solder gold and Ni and Cr of nickel-chromium base alloys were mostly distributed uniformly and the diffusion of other elements except Cr around the solder joint was not almost found.

  • PDF