• 제목/요약/키워드: experiment study

검색결과 27,875건 처리시간 0.059초

탁주(濁酒) 양조(釀造)에 관(關)한 미생물학적(微生物學的) 및 효소학적(酵素學的) 연구(硏究) (Microbiological and Enzymological Studies on Takju Brewing)

  • 김찬조
    • Applied Biological Chemistry
    • /
    • 제10권
    • /
    • pp.69-100
    • /
    • 1968
  • 1 : 탁주양조(濁酒釀造)에 가장 큰 미생물원(微生物源)이 되는 누룩중(中)의 미생물군(微生物群)과 효소(酵素)를 조사하기 위(爲)하여 충남대학교(忠南大學校) 농과대학(農科大學)에서 제조(製造)한 누룩(S)와 시판(市販) 누룩(T)을 공시(供試)하여 사상균(絲狀菌), 호기성세균(好氣性細菌), 유산균(乳酸菌) 및 효모(酵母)를 검색(檢索) 계수(計數)하고 특(特)히 효모(酵母)는 TTC-agar 처리(處理)로서 그 정색별(呈色別)에 따라 유별(類別)하였으며 또한 Amylase 및 Protease 역가(力價)를 측정(測定)하여 얻은 결과(結果)는 다음과 같다. (a) S 누룩 1gm. 중(中)에는 Aspergilles eryzae group: $240{\times}10^5$, Black aspergilli: $163{\times}10^5$, Rhizopus: $20{\times}10^5$, Penicillia: $134{\times}10^5$, 호기성(好氣性) 세균(細菌): $9{\times}10^6{\sim}2{\times}10^7$, 유산균(乳酸菌): $3{\times}10^4$개(個)이였으며 T 누룩 1gm.중(中)에는 Aspergilles oryzae group: $836{\times}10^5$, Black aspergilli: $268{\times}10^5$, Rhizopus: $623{\times}10^5$, Penicillia: $264{\times}10^5$, 호기성(好氣性) 세균(細菌): $5{\times}10^6{\sim}9{\times}10^6$, 유산균(乳酸菌): $3{\times}10^4$개(個)이였다. (b) S 누룩중(中) 호기성세균(好氣性細菌)은 $80{\sim}90%$가 Bacillus subtilis 계(系)인것 같았으며 T 누룩의 것은 70%내외(內外)가 구균(球菌)이었고 유산균(乳酸菌)은 양(兩)누룩이 다 약(約) 80%가 구상유산균(球狀乳酸菌)이였다. (c) S 누룩 1gm.중(中)의 효모(酵母)는 약(約) $6{\times}10^4$개(個)로서 이 중(中) TTC Pink 효모(酵母)가 56.5%, Red pink 효모(酵母): 16%, Red 효모(酵母): 8%, White 효모(酵母): 19.5%이었으며 T 누룩 1gm.중(中)의 효모(酵母)는 약(約) 개(個)로서 이 중(中) Pink: 42%, Red Pink: 21%, Red: 28%, White: 9%이였다. (d) S 누룩 1gm.중(中)의 효소력(酵素力)은 액화형(液化型) amylase: $D^{40}^{\circ}_{30}^'=32\;W.V.$, 당화형(糖化型) amylase: 43.32 A.U., Acid protease 181 C.F.U., Alkaline pretease: 240 C.F.U.이였으며 T 누룩 1gm.의 효소력(酵素力)은 액화형(液化型) amylase: $D^{40}^{\circ}_{30}^'=32\;W.V.$, 당화형(糖化型) amylase: 34.92 A.U., Acid protease 138 C.F.U., Alkaline pretease: 31 C.F.U.이였다. 2 : S, T 누룩으로서 탁주(濁酒)를 담금하여 전양조(全釀造) 기간중(期間中) 매(每) 12시간(時間)의 미생물군(微生物群) 및 효소력(酵素力)의 소장(消長)을 측정(測定)하고 주효모(主酵母)라고 인정(認定)한 Pink와 Red 효모(酵母)를 분리배양(分離培養)하여 유산첨가(乳酸添加)로 pH를 4.2로 조절(調節)한 S, T 각구(各區)술덧에 $1{\times}10^6ml$개(個)를 첨가(添加) 양조(釀造)한 각(各)술덧중(中)의 미생물군(微生物群)의 소장(消長)을 측정(測定)하여 얻은 결과(結果)는 다음과 같으며 이 실험에서도 효모(酵母)는 TTC 정색별(呈色別)로 유별(類別) 계수(計數)하였다. (a) 각시료구(各試料區)에서 사상균(絲狀菌)은 담금후(後) $2{\sim}3$일경(日頃)부터 검출(檢出)되지 않았으며 호기성(好氣性) 세균(細菌)은 담금 직후(直後) 술덧 매(每) ml 당(當) S 누룩 사용(使用)의 3구(區)에서 $15{\times}10^7{\sim}35{\times}10^7$개(個), T 누룩 사용(使用)의 3 구(區)에서 $8.2{\times}10^7{\sim}12{\times}10^7$개(個)가 검출(檢出)되어 이중(中) 구균(球菌)은 유산(乳酸) 무첨가(無添加)로 담금한 S 및 T구(區)에서는 36시간경(時間頃)까지 많은 증식(增殖)을 하다가 기후(其後) 급속(急速)히 감소(減少)되고 유산(乳酸) 첨가(添加)로 담금한 SP, SR, TP, 및 TR 구(區)에서는 처음부터 거의 검출(檢出)되지 않고 Bacillus는 각구(各區)에서 다 같이 많은 기복(起伏)이 있는 소장(消長)을 하였으나 말기(末期)에는 초기(初期)의 약(約) $1/5{\sim}1/10$ 수(數)로 감소(減少)되었다. (b) 유산균(乳酸菌)은 담금후(後) 24시간경(時間頃)에 S 구(區)에서는 술덧 매(每) ml 당(當) 약(約) $7.4{\times}10^7$ 개(個)가 검출(檢出)되어 $3{\sim}4$일경(日頃)까지 약(約) $2{\times}10^8$ 개(個)로 증식(增殖)하고 그후(後) 급속(急速)히 감소(減少)되어 말경(末頃)에는 약(約) $4{\times}10^5$ 개(個)가 존재(存在)하였으며 T 구(區)에서는 24시간경(時間頃)에 검출(檢出)되었으며 3일경(日頃)에는 약(約) $3{\times}10^7$ 개(個), 말경(末頃)에는 약(約) $2{\times}10^5$ 개(個)가 존재(存在)하였다. 한편 SP, SR, TP, 및 TR 구(區)에서는 각구(各區)마다 24시간경(時間頃)에 약(約) $4{\times}10^5$ 개(個)로 현저(顯著)히 적은 수(數)가 검출(檢出)되었으며 기후(其後) 별(別) 변동(變動)없는 소장(消長)을 하거나 사멸(死滅)되어 거의 검출(檢出)되지 않았다. (c) 각구(各區)술덧에서 검출(檢出)된 유산균(乳酸菌)은 대부분(大部分) 구상균(球狀菌)이였으며 또한 유산균(乳酸菌)의 소장(消長)은 술덧중(中)에 생성(生成)되는 유산(乳酸) 및 Alcohol 함량(含量)과 부합(符合)되는 경향(傾向)이였다. (d) 효모(酵母)는 24시간경(時間頃)부터 증식(增殖)이 뚜렷하여 술덧 매(每) ml당(當) S 구(區)에서는 약(約) $2{\times}10^8$ 개(個)가 되고 48시간경(時間頃)에는 약(約) $4{\times}10^8$ 개(個)가 되어 계속(繼續)하다가 후기(後期)에 다시 증가(增加)되어 $5{\sim}7{\times}10^8$ 개(個)가 되었으며 T 구(區)에서는 24시간경(時間頃)에 $4{\times}10^8$ 개(個)가 되었고 기후(其後) 기복(起伏)을 보이면서 $2{\sim}5{\times}10^8$ 개(個)로 계속(繼續)하였다. (e) S, T 양구(兩區)술덧중(中)에서 소장(消長)한 효모(酵母)는 TTC Pink 효모(酵母)가 90%이상(以上)을 차지하고 Red pink 및 Red 효모(酵母)는 전양조기간(全釀造期間)을 통(通)하여 $2{\times}10^6{\sim}3{\times}10^7$ 개(個) 사이에서 소장(消長)하였다. (f) SP 에서는 효모(酵母)는 24시간경(時間頃)에 S 구(區)보다 2배(倍)가 되는 약(約) $5{\times}10^8$ 개(個)의 Pink 효모(酵母)가 검출(檢出)되었으며 중기말경(中期末頃)까지는 S 구(區)보다 많은 수(數)이였으나 후기(後期)에는 별차(別差)없는 수(數)가 되었다. (g) SR 구(區)에서 소장(消長)하는 총효모수(總酵母數)는 SP 구(區)와 대차(大差)는 없었으나, 첨가(添加)해준 Red 효모(酵母)는 초기(初期)에 다소(多少) 많이 검출(檢出)되고 3일후(日後)부터는 S 구(區)와 별차(別差)없는 수(數)로 소장(消長)하였으며 TR구(區)에서도 Red 효모(酵母)가 초기(初期)에는 T 구(區)에 비(比)해서 많았으나 중기이후(中期以後)부터는 T 구(區)와 별차(別差)없는 경향(傾向)이어서 Red 효모(酵母)를 가(加)한 구(區)에서도 Pink 효모(酵母)가 훨씬 우세(優勢)함을 보여 본실험(本實驗)에서 검출(檢出)된 Red 효모(酵母)는 탁주양조(濁酒釀造)에서 후기(後期)까지 계속(繼續) 생육(生育)은 하나 많은 증식(增殖)은 하지 않았다. (h) TP 구(區)에서 Pink 효모(酵母)는 2일경(日頃)에 약(約) $5{\times}10^8$ 개(個)가 되어 T 구(區)에 비(比)해서 많고 기후(其後) 감소(減少)되는 경향(傾向)이나 T 구(區)보다는 많으며 후기(後期)에서는 역시(亦是) T 구(區)와 별차(別差)없는 수(數)가 되었다. (i) 술덧중(中)의 효모(酵母) 소장(消長)과 동시(同時)에 Alcohol 생성량(生成量)을 측정(測定)한 결과(結果) Pink 효모(酵母)를 첨가(添加)한 구(區)에서 초기(初期)에 다소(多少) 많은 생성량(生成量)을 보였으나 중기(中期) 이후(以後)는 효모(酵母) 무첨가구(無添加區)와의 차이(差異)를 인정(認定)할 수 없었고 또 Alcohol생성(生成)은 효모(酵母) 총수(總數)와 비례(比例)하지 않았다. (j) 액화형(液化型) Amylase는 담금 후(後) 12시간경(時間頃)까지 가장 강(强)하고 24시간경(時間頃)에 일단(一旦) 감소(減少)되었다가 시간경(時間頃)에 최고(最高)로 증가(增加)된 후(後) 74시간경(時間頃)까지 서서(徐徐)히 감소(減少)되고 기후(其後)는 급(急)히 감소(減少)를 보였다. (k) 술덧발효중(醱酵中) Alkaline protease는 불규칙적(不規則的)이기는 하나 계속(繼續) 감소(減少)되는 소장(消長)이었고 Acid protease는 24시간경(時間頃)에 최고(最高)로 증가(增加)하였다가 급(急)히 감소(減少)된 후(後) 다시 증가(增加)하는 불규칙적(不規則的)인 소장(消長)을 보였으나 Alkaline protease 보다는 계속(繼續) 강(强)하였었다. 3 : 본실험(本實驗)에서 가장 많이 검출(檢出)된 TTC Pink 효모(酵母)와 계속(繼續) 나타난 2주(株)의 Red Pink 효모(酵母) 및 1주(株)의 를 동정(同定)하고 이들의 생리적성질(生理的性質)을 검사(檢査)한 결과(結果)는 다음과 같다. (a) TTC Pink 효모(酵母)(B-50P)와 2주(株)의 Red Pink 효모(酵母)(B-54RP 및 B-60RP)는 Saccharomyces cerevisiae 형(型)이였고 Red 효모(酵母)(B-53P)는 Hansenula subpelliculosa 형(型)이였다. (b) 분리동정(分離同定)한 발효력(醱酵力)을 측정(測定)한 결과(結果) 2주(株)의 TTC Red Pink 효모(酵母)가 가장 강(强)하고 Pink 효모(酵母)가 다소(多少) 떨어지며 Red효모(酵母)는 현저(顯著)히 약(弱)함을 보였고 특(特)히 Pink 및 2주(株)의 Red Pink 효모(酵母)는 초발효력(初醱酵力)이 강(强)하여 탁주양조(濁酒釀造)에 적합(適合)함을 알았으며 Red효모(酵母)는 발효력(醱酵力)은 약(弱)하나 Ester생성력(生成力)이 강(强)하여 탁주양조(濁酒釀造)에 중요(重要)한 역할(役割)를 하는것을 알았다. 따라 탁주양조(濁酒釀造)에는 TTC Red Pink 및 Pink로 정색(呈色)되는 Saccharomyces cerevisiae 형(型)이 우량(優良)함을 추정(推定) 할 수 있었다. (c) 분리동정(分離同定)한 4주(株)효모(酵母) 아초산내성(亞硝酸耐性)은 강(强)하였으며 유산내성(乳酸耐性)은 국즙(麴汁) 배지(培地)에서 3%정도(程度)이었으나 Red효모(酵母)는 더 강(强)하였고 Alcohol 내성(耐性)은 Hayduck배지(培地)에서 Pink 및 Red Pink 효모(酵母)는 3%정도(程度)이고 맥아즙(麥芽汁) 배지(培地)에서는 13%정도(程度)이었으나 Red 효모(酵母)는 이들보다 훨씬 약(弱)하였으며 Gelatin 액화(液化)는 2주(株)가 다 40일(日)까지 (-)이였다. 4 : 탁주양조중(濁酒釀造中)의 발효도(醱酵度)는 2일경(日頃)에 총발효율(總醱酵率)의 $70{\sim}80%$가 이루어지고 $3{\sim}4$일경(日頃)까지 90%내외(內外)가 진행(進行)되어 주발효(主醱酵)는 이 시기(時期)에 종료(終了)됨을 보였으며 또한 탁주양조(濁酒釀造)에 있어서 담금한 총전분량(總澱粉量)에 대(對)한 주정(酒精) 발효율(醱酵率)은 65%내외(內外)가 됨을 알 수 있었다. 5 : 제등(齊藤)가 탁주(濁酒)술덧에서 분리(分離)한 Saccharomyces coreanus가 본실험(本實驗)에서 전연(全然) 검출(檢出)되지 않은 이유(理由)는 1930년경(年頃)부터 누룩제조(製造)에 국균(麴菌)을 종균(種菌)으로 접종(接種)하였으며 또한 탁주양조(濁酒釀造)에 일본국(日本麴)도 혼합사용(混合使用)하여서 탁주양조(濁酒釀造)에 있어서 미생물상(微生物相)이 완전(完全)히 달라진 탓이 아닌가 생각되며 이것을 뒷받침 하는 것으로 과거의 약탁주(藥濁酒) 고유미(固有味)가 달라진 것을 들 수 있다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

시뮬레이션 모형에 의한 온실의 열환경 분석 (Analysis of Greenhouse Thermal Environment by Model Simulation)

  • 서원명;윤용철
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.215-235
    • /
    • 1996
  • 본 연구에서 수행한 Model 시뮬레이션에 의한 열환경 분석 기법은 지역별로 다양한 기상여건 하에서 대상온실의 난방 및 냉방부하를 보다 합리적으로 예측할 수 있을 뿐만 아니라 냉방이나 난방용 시스템의 결정을 비롯한 난방대책을 수립하고, 에너지 이용 전략의 수립이나 계절적인 작부계획 수립, 온실산업용 적지선정 등에 유익하게 활용될 수 있을 것이라 판단된다. 본 연구에서는 온실의 적극적인 환경조절 유형을 난방과 냉방의 두 가지로 대별하고, 난방 소요열량 산정을 비롯하여 야간의 보온 커튼효과, Heating Degree-Hour 산정 등 난방과 관련된 시뮬레이션은 동적 모형을 이용하여 시간별, 일별 및 월별로 검토하였으며, 환기를 비롯한 차광, 증발냉각시스템의 효과 분석은 정적모형을 이용하여 검토하였다. 특히 하절기 지하수와 같은 저온수를 직접 이용하거나 Heat Pump를 통하여 확보될 수 있는 저온수를 이용하여 온실의 피복면에 살수함으로서 확보할 수 있는 온실냉방효과를 검토하는 데는 1.2m$\times$2.4m 크기의 모형온실을 제작하여 기초실험을 수행함으로서 동절기의 수막시스템의 보온효과와 마찬가지로 하절기 냉방 효과를 거둘 수 있다는 가능성을 확인하였다. 본 연구에 활용된 온실의 수치 환경모형 중 난방관련 시뮬레이션용 동적 수치모형은 소기의 목적을 달성하는데 충분히 응용될 수 있는 이론모형이다. 이 이론모형이 범용성이 높은 것은 온실 내ㆍ외의 미기상 변화, 특히 난방이나 냉방이 본격적으로 요구되는 기간동안에 온도, 습도, 일사, 풍속 등의 미기상 인자들을 면밀하게 관찰하여 실측된 자료를 바탕으로 개발되었고, 다양한 자료에 의해 충분히 검정되었기 때문이다. 본 연구에서는 경남 진주지역의 어느 특정 기간(1987년)의 시간별 기상자료를 중심으로 온실의 열적 환경변화에 대한 수치모형 시뮬레이션을 실시하였으며, 아직 수치모형에 의한 시뮬레이션이 불가능한 일부 냉방효과를 검토하는 데는 모형 실험을 실시하였으며, 그 결과를 요약하면 다음과 같다. 1. 주간과 야간의 설정온도를 달리하고 다단계 변온조절방식으로 시뮬레이션을 행한 결과 난방 소요열량은 난방 설정온도에 따라 현저한 차이를 보였다. 특히 주간 설정온도에 비하여 야간 설정온도가 난방 소요열량에 예민하게 영향을 미치므로 야간의 설정온도 결정에 신중을 기해야 할 것으로 판단된다. 2. 기존의 Heating Degree-Hour 자료는 평균 외기온을 중심으로 임의의 설정온도에 대하여 산정된 값이므로 난방 소요열량에 대한 상대적인 비교수단은 되나 고려되는 기상인자의 제한과 설정온도의 임의성 때문에 실용성이 부족하다. 따라서 본 연구에서 제시된 것처럼 온실 주변의 제반 미기상 인자나 경계조건이 반영됨은 물론 작물의 생육상태 및 구체적인 설정온도까지도 고려하는 동적 수치모형으로 시시각각으로 예측된 실내기온을 중심으로 재배기간 동안의 난방열량을 적산함이 합리적이라 판단된다. 기존의 MDH 자료로 난방 설계를 할 경우에는 지나치게 과잉설계 될 가능성이 있다. 3. 산정된 난방 소요열량은 물론 커튼의 보온성능도 월별 기상여건에 따라 현저한 차이를 보이며, 시뮬레이션에 이용된 커튼의 경우 높은 보온효과를 보임으로서 년 평균 50% 이상의 난방 에너지를 절감할 수 있으며, 동절기 3-4개월의 집중 난방기에 에너지가 크게 절감됨을 발견할 수 있다. 4. 고온기 환기성능은 온실의 구조, 기상조건, 작물의 생육상태 등에 따라 다소의 차이가 있으나 환기율에 의해 크게 좌우되며, 시뮬레이션에 이용된 두 가지 농가보급형 온실 모두 환기율의 증가에 따른 실내기온의 강하 효과가 환기율이 1회/min 정도를 넘어서면서 급격히 둔화되는 현상을 보인다. 이는 기존에 권장되고 있는 적정 환기율인 1회/min 전후의 환기 시스템을 갖추는 것이 합리적임을 확인해 준다. 5. 작물이 성숙된 유리온실에서 외기의 상대습도가 50%인 쾌청한 주간동안 연속적으로 1회/min로 환기를 시킬 경우 실내기온 36.5$^{\circ}C$의 대조구에 비한 온도강하는 50% 차광만 했을 시 2.6$^{\circ}C$이고 효율 80%의 Pad & Fan 시스템만 작동시 6.1$^{\circ}C$ 정도이며, 차광과 냉각시스템을 동시에 작동시는 약 8.6$^{\circ}C$로서 외기온보다 3.3$^{\circ}C$가 낮은 28$^{\circ}C$까지 실내온도를 낮출 수 있으나, 동일 조건하에서 외기의 상대습도가 80%로 높은 경우에는 Pad & Fan시스템에 의한 온도강하가 2.4$^{\circ}C$에 불과하여 50% 차광하에서도 외기온 이하로 실내온도를 낮출 수 없음을 알 수 있다. 6. 하절기 3개월(6/1-8/31)동안 Pad & Fan 시스템의 냉방효과($\Delta$T)는 설정된 작동 온도에 따라 다소 차이를 보일 것으로 예상되나 본 시뮬레이션에서 설정한 시스템의 작동 온도 27$^{\circ}C$에서 상대습도와의 상관관계는 대략 다음과 같았다: $\Delta$T= -0.077RH+7.7 7. 전형적인 하절기 주간기상 하에서 경시적 냉방효과를 분석한 결과 환기만으로는 실내기온을 외기온 보다 5$^{\circ}C$ 높게 유지하는 정도가 고작이고, 차광이나 증발식 냉방시스템 만으로는 작물이 성숙한 단계에서조차도 외기온 이하로 떨어뜨리기가 어려우나 차광과 아울러 증발식 냉방을 병행할 경우에는 작물상태에 따라 다소 차이는 있지만 실내기온을 외기온보다 2.0-2.3$^{\circ}C$ 낮게 유지할 수 있음을 발견할 수 있다. 8. 일사가 차단된 27.5-28.5$^{\circ}C$의 외기온하에서 6.5-8.5$^{\circ}C$의 냉수를 온실 바닥면적 1$m^2$당 1.3 liter/min의 유량으로 온실표면에 살수했을 때 실내기온을 외기온보다 1$0^{\circ}C$ 낮은 16.5-18.$0^{\circ}C$ 정도로 낮출 수 있었다. 앞으로 살수 수온(T$_{w}$ )이나 외기온(T$_{o}$ ) 뿐만아니라 살수율(Q)에 따라 온실기온 (T$_{g}$ )에 미치는 상관 관계 T$_{g}$ = f(T$_{w}$ , Q, T$_{o}$ )를 구명하여 지하수 자체 또는 Heat Pump를 이용한 지하수온 이하의 냉수로 온실냉방의 가능성을 구명하는 것이 앞으로의 과제이다.

  • PDF

진령탕가감방의 항종양효과(抗腫瘍效果)에 관(關)한 실험적(實驗的) 연구(硏究) (Experimental Studies on the Antitumor Effects of Jinryungtang Gagambang Extract)

  • 정준택;문구;문석재
    • 대한한방종양학회지
    • /
    • 제4권1호
    • /
    • pp.37-53
    • /
    • 1998
  • 과학기술(科學技術)의 발전(發展)에 따른 생활(生活) 및 의료(醫療) 수준의 향상(向上)에도 불구하고 산업발전(産業發展)에 따른 환경오염(環境汚染), 스트레스 증가(增加) 등 그 역기능(逆機能) 때문에 발암물질(發癌物質) 또는 자극(刺戟)에의 노출(露出) 등으로 인해서 전세계적(全世界的)으로 암(癌)으로 인(因)한 사망율(死亡率)이 증가(增加)되고 있다. 암(癌)은 현재(現在) 인류(人類)의 건강(健康)을 위협하는 주요(主要)한 질환(疾患)의 하나로, 오늘날 우리 나라에서 질환(疾患)으로 인(因)한 사망원인중(死亡原因中) 수위(首位)를 차지하고 있다. 이러한 암(癌)의 발생(發生)은 80%-90%가 환경적(環境的) 인자(因子)에 기인(起因)한다고 보고(報告)되고 있는데 앞으로 환경성(環境性) 발암물질(發癌物質)이 점차 증가(增加)됨에 따라 암환자(癌患者)의 발생(發生)도 더욱 증가(增加)될 것으로 예상(豫想)된다. 암(癌)의 서의학적(西醫學的) 치료(治療)는 주로 수술요법(手術療法), 방사선요법(放射線療法), 화학요법(化學療法) 및 면역요법(免疫療法) 등이 활용(活用)되고 있다. 이중 수술요법(手術療法)과 방사선요법(放射線療法)은 암(癌)이 전신(全身)에 전이(轉移) 증식(增殖)되기 전에 실시(實施)함으로써 효과(效果)를 거둘 수는 있으나, 암(癌)이 원발병소(原發病巢) 이외(以外)에까지 전이(轉移) 증식(增殖)되었을 경우에는 이 두가지 방법(方法)의 국소요법(局所療法)만으로서는 좋은 치료효과(治療效果)를 거두기 어렵다. 따라서 최근 항암제(抗癌劑)에 의한 화학요법(化學療法)이 다른 방법(方法)보다 유효(有效)하다고 인정(認定)이 되어 가장 많이 활용(活用)되고 있으나, 암종(癌種)에 대한 감수성차이(感受性差異), 치료후(治療後)의 부작용(副作用), 재발(再發) 및 합병증(合倂症) 등의 문제점(問題點)때문에 부작용(副作用)을 감소(減少)시키면서 항암효과(抗癌效果)를 높이는 치료법(治療法)이 계속 연구(硏究)되고 있다. 이에 1972년(年) 미국(美國) 국립암연구소(國立癌硏究所)에서 실시(實施)한 항암제(抗癌劑) 개발연구(開發硏究)에 있어서 항종양성(抗腫瘍性) Screening test에 이용(利用)된 물질중(物質中) 약 47%가 천연물질(天然物質)이었다는 사실은 주목(注目)할만 하다. 한의학적(韓醫學的) 치료법(治療法)은 최근(最近)에 변증시치(辨證施治)를 근간(根幹)으로 하여 건비익기(健脾益氣)를 위주(爲主)로한 부정거사법(扶正祛邪法)과 부정배본법(扶正培本法)이 많이 활용(活用)되고 있으며 부정법(扶正法)으로는 익기건비(益氣健脾), 자음보혈(滋陰補血), 온보비신(溫補裨腎) 등이, 거사법(祛邪法)으로는 활혈거어법(活血祛瘀法), 청열해독법(淸熱解毒法), 연견화담법(軟堅化痰法) 등이 활용(活用)되고 있는데, 이를 근거(根據)로 하여 한약(韓藥)의 복방(複方).단미(單味).단미추출물(單味抽出物) 등의 투여(投與)와 침(鍼) 구(灸) 수침(水鍼) 전침(電鍼) laser침(鍼)등의 치료방법(治療方法)을 수술(手術) 후(後) 혹(或)은 화학요법(化學療法)이나 방사선요법(放射線療法)와 병행(幷行)하여 치료효과(治療效果)가 향상(向上)되었다고 보고(報告)하고 있다. 항암제(抗癌劑)의 항암효과(抗癌效果) 정도(程度)를 검사(檢査)하는 방법(方法)은 크게 5가지로 분류(分類)되는데, 하나는 세포(細胞)를 약제(藥劑)에 노출(露出)시킨 후 현미경(顯微鏡)을 통하여 나타난 형태학적(形態學的) 변화(變化)를 가지고 약제(藥劑)의 효과정도(效果程度)를 결정(決定)하는 방법(方法)이고, 둘째는 Dye exclusion assay방법(方法)으로 살아있는 세포(細胞)가 trypan blue, eosin, nigrosin과 같은 염색액(染色液)에 염색(染色)되지 않는 점을 이용(利用)한 것이며, 세번째는 항암제(抗癌劑)의 항암효과(抗癌效果)를 알아보는 지표(指標)로 사용(使用)되는 Crrelease assay가 있으나, 세가지 방법(方法) 모두 현재(現在) 사용(使用)되고 있지 않다. 넷째로는 세포(細胞) 대사(代謝)의 방해정도(妨害程度)를 측정(測定)하거나 세포내(細胞內) 방사성(放射性) 동위원소(同位元素)의 유입방해(流入妨害) 정도(程度)를 측정(測定)하는 방법(方法)이 있고, 다섯째로는 본(本) 실험(實驗)에서 사용(使用)한 방법(方法)으로 stem cell assay라고도 하는 clonogenetic assay가 있는데, 이는 세포(細胞)를 약제(藥劑)에 노출(露出) 시킨 후 soft agar에 single cell suspension으로 배양(培養)하여 그 세포(細胞)의 분열(分裂).증식능력(增殖能力)을 측정(測定)하는 방법(方法)이다. 이 방법(方法)은 특히 성장(成長) 특성(特性)이 다른 종양세포(腫瘍細胞)의 경우 개개(個個) 세포(細胞)에 대한 약제효과(藥劑效果)를 반영(反映)할 수 있어서 종양세포(腫瘍細胞)의 이질성(異質性)에 따른 차이점(差異點)을 보정(補整)할 수 있는 방법(方法)이며, 1971년(年) Park 등이 마우스 골수종(骨髓腫) 세포(細胞)에 대한 stem cell assay를 시행(施行)해 본 결과(結果) in vivo에서의 결과(結果)와 잘 일치(一致)하여 그 이후로는 종양세포(腫瘍細胞)에 대한 항암제(抗癌劑)의 약제(藥劑) 감수성검사(感受性檢査)에 많이 사용(使用)되고 있다. 진령탕가감방은 담습응결(痰濕凝結)을 치료(治療)하는 효능(效能)을 가진 처방(處方)으로 거담작용(祛痰作用)을 가진 반하(半夏), 패모(貝母), 거습작용(祛濕作用)을 가진 의이인(薏苡仁), 백복령, 이기(理氣) 하기작용(下氣作用)을 가진 진피(陳皮), 대자석, 정향(丁香), 비파엽(枇杷葉), 항암작용(抗癌作用)을 가진 용규(龍葵), 반지련(半枝蓮), 모려(牡蠣), 하고초(夏枯草), 저령 등(等)의 약물(藥物)로 구성되어 있다. 근래(近來) 단일약물(單一藥物)의 항암효과(抗癌效果)에 대한 실험적(實驗的) 연구(硏究)로는 금(金) 등에 의한 인삼(人蔘), 녹용(鹿茸)의 항체생산(抗體生産) 억제(抑制) 완화효과(緩和效果) 및 임(任)에 의한 어성초(魚腥草), 녹혈(鹿血), 저령, 천산갑(穿山甲) 등이 정상(正常) 면역세포(免役細胞)에는 거의 독작용(毒作用)을 일으키지 않으면서 강력(强力)한 항암효과(抗癌效果)가 있다는 보고(報告), 금(金) 등에 의한 자완, 동풍채(東風菜), 영지(靈芝), 선학초(仙鶴草), 파두(巴豆) 등이 항암작용(抗癌作用) 및 면역반응(免疫反應)에 효과(效果)를 미친다는 보고(報告) 등이 있고, 복합제제(複合製劑) 약물(藥物)의 항암효과(抗癌效果)에 대한 연구(硏究)로는 강(姜) 등에 의한 식분환(息賁丸), 비기환(肥氣丸) 및 비기환이 백혈병(白血病)과 임파종환자(淋巴腫患者)에서 추출(抽出)한 암세포(癌細胞)에 항암효과(抗癌效果)가 있다는 보고(報告) 및 금(金) 등에 의한 복량환(伏梁丸), 비기환 및 소적정원산(消積正元散)이 각종(各種) 암세포주(癌細胞柱)이 성장저애(成長沮碍) 효과(效果), 윤(尹) 등에 의한 육군자탕(六君子湯), 소시호탕(小柴胡湯), 사묘탕(四妙湯), 대시호탕(大柴胡湯), 방독탕(防毒湯), 반하백출천마탕(半夏白朮天麻湯), 파두(巴豆)를 가미(加味)한 사군자탕(四君子湯) 및 사물탕(四物湯) 등이 항암작용(抗癌作用) 및 면역반응(免疫反應)에 효과(效果)를 보인다는 보고(報告) 등이 있었으나, 아직까지 진령탕가감방의 항암효과(抗癌效果)에 대한 실험연구(實驗硏究)는 없었다. 이에 저자(著者)는 항암효과(抗癌效果)가 있을 것으로 추정(推定)되는 진령탕가감방의 항종양효과(抗種瘍效果)를 알아보기 위하여, 수용성(水溶性) 추출액(抽出液)을 얻은 후 현대(現代) 병리학적(病理學的)으로 다용(多用)하는 colony형성억제실험(形成抑制實驗), SRB assay에 의한 항종양효과(抗種瘍效果), 생명연장율(生命延長率), 화학적(化學的)인 방법(方法)과 암종세포(癌腫細胞) 이식(移植)에 의한 종양(腫瘍) 유발(誘發)을 통하여 암(癌) 발생(發生) 및 그 경과(經過)에 미치는 영향(影響) 및 NK세포활성(細胞活性)에 미치는 영향(影響) 등을 관찰(觀察)하였다. 본(本) 실험(實驗)에서는 진령탕가감방의 종양세포(腫瘍細胞)에 대한 증식억제작용(增殖抑制作用)을 관찰(觀察)하고자 in vitro test인 colony형성억제실험(形成抑制實驗)과 SRB assay를 이용(利用)하였는데, 진령탕가감방의 추출액(抽出液)이 종양세포(腫瘍細胞)의 성장(成長)을 억제(抑制)하는 효과(效果)가 농도의존적(濃度依存的)으로 증가(增加)하는 결과(結果)를 보여 항종양(抗腫瘍)의 효과(效果)가 있음을 나타냈고(Table 3, 4), in vivo assay로서 sarcoma 180 복수암세포를 이식(移植)한 마우스의 평균생존일수(平均生存日數)를 관찰(觀察)하여 NCI protocol에 의하여 검정(檢定)한 결과(結果), 진령탕가감방 추출액(抽出液)을 투여(投與)한 마우스의 평균생존기간(平均生存期間) 및 생명연장율(生命延長率)이 뚜렷하게 증가(增加)되었다(Table 5). 또한 진령탕가감방 추출액(抽出液)을 마우스에 투여(投與)하면 MCA로 유도(誘導)한 종양(腫瘍) 및 3LL 세포(細胞) 이식(移植)에 의한 종양(腫瘍)의 발생율(發生率) 및 발생(發生)된 종양(腫瘍)의 크기가 현저히 감소(減少)되었다(Table 6, 7). 이러한 효과(效果)는 진령탕가감방이 감수성(感受性) 암종세포(癌腫細胞)에 직접적으로 영향(影響)을 미쳐 그 증식(增殖)이 억제(抑制)되었을 가능성(可能性)을 생각할 수 있다. 그렇지만 본(本) 연구(硏究)에서는 암종특이성(癌腫特異性)에 관한 결론(結論)을 내릴 수는 없으므로 암종특이성(癌腫特異性)에 관한 연구(硏究)는 진행(進行)해야 할 것으로 생각된다. 또 다른 가능(可能)한 진령탕가감방 추출액(抽出液)의 항종양(抗腫瘍) 작용기전(作用機轉)은 진령탕가감방 추출액(抽出液)이 NK세포(細胞)의 활성(活性)을 항진(亢進)시킨 실험결과(實驗結果)로 유추(類推)하여, 진령탕가감방 추출액(抽出液)이 종양(腫瘍)마우스에 비특이적(非特異的)인 면역활성(免疫活性)을 촉진(促進)시킴으로써 진령탕가감방 추출액(抽出液)의 항종양작용(抗腫瘍作用)이 발현될 가능성(可能性)도 생각할 수 있다. 따라서 앞으로 여러 암종세포(癌腫細胞)에 대한 진령탕가감방 추출액(抽出液)의 항종양작용(抗腫瘍作用)과 종양동물(腫瘍動物)에서의 진령탕가감방 추출액(抽出液) 투여(投與)에 의한 생체생리현상(生體生理現象)의 변화(變化), 생리활성물질(生理活性物質)의 본능(本能) 등을 밝히기 위한 보다 구체적(具體的)이고 광범위(廣範圍)한 연구(硏究)가 수행(隨行)되어져야 되리라고 사료(思料)된다. 세포성(細胞性) 면역반응중(免疫反應中) 중요(重要)한 역할(役割)을 하는 작동세포중 NK세포(細胞)는 여러 종양(腫瘍)에 대해 자연살해능(自然殺害能)을 보여 소위 T비의존성(非依存性) 면역감시기전(免疫監視機轉)에 관하여는 바이러스 및 세균(細菌)에 감염(感染)된 세포(細胞)를 파괴(破壞)하는 활성(活性)을 가지며, IL-2 및 Interferon 등에 의하여 활성(活性)이 증가(增加)된다. NK세포(細胞)가 표적세포를 파괴(破壞)하는 기전(機轉)에 관해서는 아직 확실히 알려져 있지 않으나, 첫째로 표적세포를 인식(認識)하는 시기(時期), 둘째로 융해기전(融解機轉)을 활성화(活性化)시키는 시기(時期), 셋째로 NK lymphotoxin이 유리(遊離)되는 시기(時期), 넷째로 표적세포의 사멸기(死滅期)로 나눌 수 있다. 본(本) 실험(實驗)에서 진령탕가감방 추출액(抽出液)으로 전처리(前處理)시 NK세포(細胞)의 표적세포와의 결합능(結合能)은 물론 결합(結合)된 표적세포의 융해능(融解能)이 촉진(促進)된 결과(結果)를 보이는데(Table 8), 이와 같은 결과(結果)는 진령탕가감방 추출액(抽出液)이 NK세포(細胞)의 표적세포 파괴 4단계 전체를 항진(亢進)시킨 결과(結果)로 인정(認定)된다. 이상에서 다음과 같은 결론을 얻었다. 1. 진령탕가감방 추출액(抽出液)을 폐암세포주인 A549와 간암세포주인 hep3B 및 신장암 유래의 종양세포주인 Caki-1 cell에 투여(投與)한 결과, in vitro test인 colony형성억제실험(形成抑制實驗)과 SRB assay에서 모두 농도의존적(濃度依存的)으로 암세포주 성장(成長)을 억제(抑制)하였다. 2. Strcoma 180세포(細胞)를 마우스에 이식(移植)하여 평균생존기간(平均生存期間) 및 생명연장율(生命延長率)을 측정(測定)하는 in vivo test에서는 진령탕가감방 추출액(抽出液)이 마우스의 평균생존기간(平均生存期間) 및 생명연장율(生命延長率)을 증가(增加)시키는 결과(結果)를 보였다. 3. 진령탕가감방 추출액(抽出液)은 MCA로 유도(誘導)한 종양(腫瘍)의 발생율(發生率) 및 발생종양(發生腫瘍)의 크기를 현저히 감소(減少)시켰으며, 3LL세포(細胞) 이식(移植)에 의한 종양발생(腫瘍發生) 또한 현저히 감소(減少)시켰다. 4. 진령탕가감방 추출액(抽出液)은 NK세포(細胞)의 활성도(活性度)를 증가(增加)시켰다. 특히 $10{\mu}g/ml$ 농도 에서 NK세포(細胞) 활성도(活性度)가 가장 현저히 증가(增加)되었다. 이상(以上)의 결과(結果)로 보아 진령탕가감방은 암종세포(癌腫細胞)에 대한 직접적(直接的)인 성장억제(成長抑制) 및 세포(細胞)의 활성(活性)을 통한 면역증진(免疫增進)에 의해 다양(多樣)한 항종양효과(抗腫瘍效果)를 보인 것으로 사료(思料)된다.

  • PDF