• Title/Summary/Keyword: experiment scenario

Search Result 203, Processing Time 0.026 seconds

Experimental Study on Temporary Overvoltage Characteristics of MOV Based Surge Protective Devices (MOV 기반 서지보호기의 일시과전압 특성에 대한 실험적 연구)

  • Shim, Hae-Sup;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.71-77
    • /
    • 2010
  • Protection against lightning surge is an essential part of almost any electrical and electronic equipment today. Metal Oxide Varistor(MOV) is the single most important component in the overwhelming majority of the Surge Protective Devices(SPD) designated to provide such protection. In this paperr various types of MOV based SPD are inspected and experiments are carried out on the side effects of the low Measured Limiting Voltage(MLV) characteristics. Experiment results show that a lower MLV could cause a higher Temporary Overvoltage(TOV)-induced SPD failure rate in the field, and SPD are more likely to be victims rather than protectors in a TOV scenario. This means that from a safety perspective, the SPD should be specified with higher TOV withstand capability(UT) and faster SPD disconnector.

Real-Time Monitoring Agent for Ubiquitous System (유비쿼터스 시스템을 위한 실시간 모니터링 에이전트)

  • Kwon, Sung-Hyun;Lee, Byoung-Hoon;Kim, Jai-Hoon;Cho, We-Duke
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.8
    • /
    • pp.803-807
    • /
    • 2008
  • The ubiquitous middleware configurated an aggregation of the various services. The services are made in different languages and the various services that are dynamically changing environment are carried out in collaboration service. The ubiquitous system that services in the these environment is required appropriate response to real-time system and reliability. In this paper, we suggest the monitoring agent that a monitoring system added or removed the services in real-time is made continuous monitoring in run-time environment and guaranteed performance and reliability of a application by maximally reducing overhead that combined with applications is occurred. The suggested scheme shows the demonstration to fit the scenario situation and verifies function and performance of monitoring about the service applications through the experiment.

A Role-based Storage Encryption for the Electronic Approval System of Battle Management Systems (전장관리체계 전자결재시스템을 위한 역할기반 스토리지 암호화 기법)

  • Her, Kyoung-Soon;Lee, Soo-Jin
    • Journal of the military operations research society of Korea
    • /
    • v.37 no.1
    • /
    • pp.71-85
    • /
    • 2011
  • The most important factors of Electronic approval system of battle management system are availability and reliability. Therefore, the electronic approval system uses a SAN(storage area network) to construct the reliable server and storage. In this paper, we analyze the security vulnerabilities of the SAN storage that stores the critical military information in the electronic approval system of battle management system. Based on the analysis, we verify the possibility of information leakage by the inside attackers through the scenario-based experiment. And we finally propose a new storage encryption algorithm on the basis of user's role that can prevent the leakage of information by the inside attackers.

Marine Ecosystem Response to Nutrient Input Reduction in Jinhae Bay, South Korea

  • Oh, Hyun-Taik;Lee, Won-Chan;Koo, Jun-Ho;Park, Sung-Eun;Hong, Sok-Jin;Jung, Rae-Hong;Park, Jong-Soo
    • Journal of Environmental Science International
    • /
    • v.15 no.9
    • /
    • pp.819-827
    • /
    • 2006
  • We study on the dynamic interaction with a simulated physical-biological coupled model response to nutrient reduction scenario in Jinhae Bay. According to the low relative errors, high regression coefficients of COD and DIN, and realistic distribution in comparison to the observation, our coupled model could be applicable for assessing the marine ecosystem response to nutrient input reduction in Jinhae Bay. Due to the new construction and expansion of sewage treatment plant from our government, we reduce 50% nutrient inputs near Masan Bay and sewage treatment plant. COD achieves Level II in Korea standard of the water quality from the middle of the Masan Bay to all around Jinhae Bay except the inner Masan Bay remaining at Level III. When our experiment reduces 50% nutrient inputs near Masan Bay and Dukdong sewage treatment plant simultaneously, COD decreases to about 0.1-1.2 mg/L $(128^{\circ}30'{\sim}128^{\circ}40'\;E,\;35^{\circ}05'{\sim}35^{\circ}11'\;N)$. The COD from the middle of the Masan Bay to Jinhae Bay achieves Level II.

Theoretical Limits Analysis of Indoor Positioning System Using Visible Light and Image Sensor

  • Zhao, Xiang;Lin, Jiming
    • ETRI Journal
    • /
    • v.38 no.3
    • /
    • pp.560-567
    • /
    • 2016
  • To solve the problem of parameter optimization in image sensor-based visible light positioning systems, theoretical limits for both the location and the azimuth angle of the image sensor receiver (ISR) are calculated. In the case of a typical indoor scenario, maximum likelihood estimations for both the location and the azimuth angle of the ISR are first deduced. The Cramer-Rao Lower Bound (CRLB) is then derived, under the condition that the observation values of the image points are affected by white Gaussian noise. For typical parameters of LEDs and image sensors, simulation results show that accurate estimates for both the location and azimuth angle can be achieved, with positioning errors usually on the order of centimeters and azimuth angle errors being less than $1^{\circ}$. The estimation accuracy depends on the focal length of the lens and on the pixel size and frame rate of the ISR, as well as on the number of transmitters used.

An Experimental Study on Smoke Spread Using a Reduced-scale Subway Building Model (지하역사 축소모델을 이용한 연기확산에 대한 실험적 연구)

  • Kim, Myung-Bae;Choi, Byung-Il
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.49-56
    • /
    • 2008
  • Smoke propagation for the Daegu Metro fire is reproduced by a reduced-scale model experiment. The three-story station building was modeled with 1/20-scale, and the tunnel connected to the platform was not completely modeled because of its length. To include the flow resistance the tunnel provides the mesh screens were used in the model. The fire scenario was selected based on the fire growth rate of the metro car seat where the fire initiated. The time when smoke arrived at each compartment in the station building was measured by thermocouples and visualization. Regarding fire ventilation, the air supply that has been accepted as conventional design in a subway metro building intensifies smoke spread. The results show that the whole building was filled with smoke in about 10 minutes in case of no ventilation.

The Effects of Consumers' Delight on the Loyalty in Service Encounter Situation (서비스인카운트 상황에서 소비자의 감동이 충성도에 미치는 영향)

  • Ko, Jae-Jung;Suh, Yong-Han
    • Management & Information Systems Review
    • /
    • v.31 no.2
    • /
    • pp.231-251
    • /
    • 2012
  • Customer delight is critical to firm's success in today's competitive environment. This importance has led marketing scholars and practitioners to recommend that firms improve their customers' delight because it is a key to customer loyalty. However, researchers and practitioners have also begun to express concern on the process that underlies customers' delight-loyalty relationship. The purpose of this paper is to investigate this question: 'Does it really matter that firms delight to their customers to achieve greater customer loyalty?' The results from one experiment using a scenario method and the data collected by questionnaire real that delighted customers(offered an unexpected gift) were significantly more warmth, joy and loyalty than satisfied respondents(offered a free gift). The warmth dimension of delight influenced positively on loyalty in satisfied customer group. In delighted customer group, both warmth and joy influenced positively on loyalty.

  • PDF

Adaptive Pre-/Post-Filters for NRT-Based Stereoscopic Video Coding

  • Lee, Byung-Tak;Lee, BongHo;Choi, Haechul;Kim, Jin-Soo;Yun, Kugjin;Cheong, Won-Sik;Kim, Jae-Gon
    • ETRI Journal
    • /
    • v.34 no.5
    • /
    • pp.666-673
    • /
    • 2012
  • Non-real-time delivery of stereoscopic video has been considered as a service scenario for 3DTV to overcome the limited bandwidth in the terrestrial digital television system. A hybrid codec combining MPEG-2 and H.264/AVC has been suggested for the compression of stereoscopic video for 3DTV. In this paper, we propose a stereoscopic video coding scheme using adaptive pre-/post-filters (APPF) to improve the quality of 3D video while retaining compatibility with legacy video coding standards. The APPF are applied adaptively to blocks of various sizes determined by the macroblock coding mode and reference frame index. Experiment results show that the proposed method achieves up to 24.86% bit rate savings relative to a hybrid codec of MPEG-2 and H.264/AVC including the inter-view prediction.

Job Allocation and Operation Scenario of Automated Material Handling for Cluster-Type Production System (클러스터 제조 라인의 작업할당 및 물류 운영 시나리오)

  • Yoon, Hyun-Joong;Kim, Jin-Gon;Kim, Jung-Yun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.33 no.3
    • /
    • pp.169-175
    • /
    • 2010
  • Recently, to improve operating efficiency with the higher in-line rate in automated production lines, a lot of cases of grouping machines and material handling system together to form a cluster has shown frequently. This article addresses the job allocation and operation method of automated material handling for cluster-type production systems. First of all, the control problems of the automated material handling systems are classified into the control problem of inter-cluster material handling system and that of intra-cluster material handling system. Then, a distributed agent-based control scheme is proposed for the former, and an operational control procedure for the latter. Simulation experiment shows that the proposed method is efficient in reducing cycle times and improving utilization of material handling vehicles.

ANALYSIS OF THE ISP-50 DIRECT VESSEL INJECTION SBLOCA IN THE ATLAS FACILITY WITH THE RELAP5/MOD3.3 CODE

  • Sharabi, Medhat;Freixa, Jordi
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.709-718
    • /
    • 2012
  • The pressurized water reactor APR1400 adopts DVI (Direct Vessel Injection) for the emergency cooling water in the upper downcomer annulus. The International Standard Problem number 50 (ISP-50) was launched with the aim to investigate thermal hydraulic phenomena during a 50% DVI line break scenario with best estimate codes making use of the experimental data available from the ATLAS facility located at KAERI. The present work describes the calculation results obtained for the ISP-50 using the RELAP5/MOD3.3 system code. The work aims at validation and assessment of the code to reproduce the observed phenomena and investigate about its limitations to predict complicated mixing phenomena between the subcooled emergency cooling water and the two-phase flow in the downcomer. The obtained results show that the overall trends of the main test variables are well reproduced by the calculations. In particular, the pressure in the primary system show excellent agreement with the experiment. The loop seal clearance phenomenon was observed in the calculation and it was found to have an important influence on the transient progression. Moreover, the collapsed water levels in the core are accurately reproduced in the simulations. However, the drop in the downcomer level before the activation of the DVI from safety injection tanks was underestimated due to multi-dimensional phenomena in the downcomer that are not properly captured by one-dimensional simulations.