• Title/Summary/Keyword: expected frequency

Search Result 2,002, Processing Time 0.033 seconds

Superconducting Low-frequency Gravitational-wave Telescope (SLGT): pilot study status report

  • Kim, Chunglee;Ahn, Sang-Hyeon;Bae, Yeong-Bok;Kang, Gungwon;Kim, Whansun;Oh, John J.;Oh, Sang Hoon;Park, Chan;Son, Edwin J.;Lee, Yong Ho;Paik, Ho Jung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.52.1-52.1
    • /
    • 2017
  • The discovery of GW150914, black hole - black hole merger via gravitational waves (GWs) opened a new window to observe the Universe. GW frequencies from heavenly bodies and early Universe are expected to span between sub-nHz up to kHz. At present, GW detectors on Earth (LIGO, Virgo, KAGRA, LIGO-India) aims frequency ranges between 10-2000 Hz. The space-borne GW detector and Pulsar Timing Array targets mHz and nHz sources. Starting in March 2017, the KKN (KASI-KISTI-NIMS) collaboration launched a pilot study of SLGT (Superconducting Low-frequency Gravitational-wave Telescope). This project is funded by NST (Korea Institute of Science and Technology). The main detection bands expected for SLGT ranges between 0.1-10Hz, which is complementary of LIGO-type detectors and LISA for multi-band GW observation. We will present an overview of the SLGT project and report the status of the NST pilot study. We will also present prospective of GW astronomy with SLGT.

  • PDF

Experimental Study on Frequency Support of Variable Speed Wind Turbine Based on Electromagnetic Coupler

  • You, Rui;Chai, Jianyun;Sun, Xudong;Bi, Daqiang;Wu, Xinzhen
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.195-203
    • /
    • 2018
  • In the variable speed Wind Turbine based on ElectroMagnetic Coupler (WT-EMC), a synchronous generator is coupled directly to the grid. Therefore, like conventional power plants, WT-EMC is able to inherently support grid frequency. However, due to the reduced inertia of the synchronous generator, WT-EMC is expected to be controlled to increase its output power in response to a grid frequency drop to support grid frequency. Similar to the grid frequency support control of Type 3 or Type 4 wind turbine, inertial control and droop control can be used to calculate the WT-EMC additional output power reference according to the synchronous generator speed. In this paper, an experimental platform is built to study the grid frequency support from WT-EMC with inertial control and droop control. Two synchronous generators, driven by two induction motors controlled by two converters, are used to emulate the synchronous generators in conventional power plants and in WT-EMCs respectively. The effectiveness of the grid frequency support from WT-EMC with inertial control and droop control responding to a grid frequency drop is validated by experimental results. The selection of the grid frequency support controller and its gain for WT-EMC is analyzed briefly.

Realtime Measurement of Impedance Locus using Impedance Spectroscopy: How Many and How Low Frequencies Are Required \ulcorner

  • T., Fukumoto;G. M., Eom;S., Ohba;N., Hoshimiya
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1194-1197
    • /
    • 2004
  • High temporal-resolution and accurate measurement of skin impedance locus provides useful data for the identification of the physiological/psychological changes and also the identification of acupuncture point. An impedance spectroscopy method using digitally constructed current waveform consisting of many frequency components (multiples of 1Hz) was reported3. The time resolution of the method depends on the lowest frequency used in the waveform construction, and therefore, the measurement would be faster if the lowest frequency is the higher. However, it was not clear that how many and how low frequencies must be used for the estimation of the skin impedance parameters from which the impedance locus can be drawn. This study shows the relationship between the estimation error of the impedance parameters and the frequency coverage of the spectroscopy. The results of this study are expected to serve as the reference of the frequency selection in the impedance spectroscopy.

  • PDF

A study on Inductance calculation in Interior Permanent Magnet Synchronous Motor (IPMSM의 인덕턴스 산정에 관한 연구)

  • Lee, Jin-Gyu;Kwon, Soon-O;Sun, Tao;Kim, Hae-Joong;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.880_881
    • /
    • 2009
  • This paper improves the calculating method about the inductance with the high order frequency coreloss. It is different in which the analyzed inductance for calculating IPMSM and the measured thing for experiment. Due to this phenomenon, the expected input voltage differs from the inquired input voltage for operating the motor. This results from the coreloss margin which have both the 1st order and high order frequency value. For reducing the inductance error, after calculating the equivalence coreloss resistance with having the 1st order frequency Back_EMF and coreloss, designing the inductance with the high order frequency which occurred by the coreloss of high order frequency, and comparing the renovated inductance analysis value with the measured thing.

  • PDF

Development of a Method to Analyze Voltage Sag Monitoring Data (순간전압강하 모니터링 데이터 분석 방법)

  • Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.16-22
    • /
    • 2013
  • This paper presents a method to analyze the voltage sag data obtained from monitoring systems. In order to establish effective countermeasures against voltage sag problems, an assessment of the system performance with respect to voltage sags is needed. Generally, the average annual sag frequency can be estimated by using the recorded voltage sag events for several years. However, the simple average value can not give the information about the errors of estimation. Such an average estimation is not useful for establishing effective solutions for voltage sag problems. Therefore, this paper proposes an effective method based on the Interval Estimation method. The estimation of voltage sag frequency is performed by using the average frequency and Poisson probability model. The proposed method can give the expected annual sag frequency and upper one-sided bound frequency.

Comparative Study on the Acoustic Characteristics of the Korean Vowel /a/ before and after LMS (후두미세수술 전후 /아/의 음향적 특성 비교)

  • Hwang, Yeon-Sin;Seong, Cheol-Jae
    • MALSORI
    • /
    • no.67
    • /
    • pp.33-60
    • /
    • 2008
  • The aim of this study is to show the differences in acoustic parameters between a pathological voice /a/ caused by vocal polyp and a normal voice /a/ produced after LMS (Laryngeal Microscopic Surgery). It was expected that voices of two kinds could be analyzed effectively in terms of HNR in specific frequency bands than in all frequency bands. For this study, 10 patients' voice were recorded before and after LMS and then were manipulated in terms of four acoustic parameter. It was found out that (a) frequency bands of 500Hz in the range of 1,000Hz to 4,000Hz were very useful to obtain HNR values; (b) frequency bands in the range of 1,248Hz to 5,500Hz on a log scale were very useful to obtain HNR values; (c) F0 dropped after LMS but not significantly; (d) the bandwidth of the second formant (B2) decreased significantly after LMS, while that of the first formant (B1) decreased after LMS but not significantly.

  • PDF

Study on Radio Frequency to Secure Private Use in Railroad (철도전용무선주파수 확보방안연구)

  • Quan, Zhong-Hua;Park, Duk-Kyu;Park, Gie-Soo;Ryou, Myung-Seon;Kim, Jae-Sik;Choi, Seung-Gap
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.2030-2037
    • /
    • 2009
  • In this paper, the study on the allocation of dedicated radio frequency for the radio communication based CBTC system is performed. The dedicated bandwidth for the the private use in railroad is figured out and the allocatable frequency band, which should be investigated hereafter, is proposed. The result of this study provides the basis to present the requirement of dedicated railroad radio frequency and can be used as an important material for the frequency allocation. Furthermore, it is expected that the result can be contributed to the development on railroad radio communication.

  • PDF

High Frequency Jet Ventilation via Cricothyroid Membrane Puncture under Microlaryngoscopic Surgery (미세 후두현미경술시 윤상갑상막천자를 통한 고빈도 제트환기법)

  • 양훈식;김용주;김춘길
    • Korean Journal of Bronchoesophagology
    • /
    • v.1 no.1
    • /
    • pp.109-115
    • /
    • 1995
  • High frequency Jet ventilation (HFJV) via cricothyroid membrane puncture contols frequency of ventilation as 20-200/min and persuits adequate gas exchange. HFJV was known to have advantages such as improvement of PaO$_2$, lesser barotrauma, stable hemodynamic effects, good operative field and lesser movement of head. The purpose of this study was to clarify the advantages of HFJV in cases of microlaryngeal surgery which operating time was expected even within 30 minutes. Twenty-eight patients were divided two groups : 1)control group : general endotracheal Intubation anesthesia. 2)experimental group : HFJV via cricothyroid membrane puncture with intravenous anesthesia, frequency 40/min, I/E ratio 40%, driving pressure 40 psi. We analyzed blood pressure, arterial blood gas, score of general condition and recovery time after operation. In conclusion, HFJV via cricothyroid membrane puncture had a good score of general condition and rapid recovery of consciousness, although some accumulation of P$CO_2$and elevation of blood pressure.

  • PDF

Evaluation of AGC Characteristics and a Novel AGC Control Strategy for Independent Power Systems (단독계통의 주파수 제어를 위한 자동발전제어(AGC) 특성 분석 및 새로운 제어전략)

  • Choi, Seung-Ho;Hwang, Kyo-Ik;Chun, Yeonghan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.11
    • /
    • pp.540-547
    • /
    • 2005
  • One of the roles of AGC is to regulate the frequency of power systems. AGC is also used to control the frequency of Korean Power System. AGC control strategies depend on system characteristics and the requirements of the systems to which those are applied. Korean Power System consists of one control area and does not have tie-lines. In this research, an AGC control strategy is suggested to avoid conflict with governor dynamics and to enhance frequency recovery It shows good performance for regulation and frequency recovery. This control strategy is expected to be applied to New EMS in KPX to get reasonable AGC regulation and frequency recovery performance.

The Response Properties of Organic Gas for the Palmitic Acid LB films by the Effect of pH (pH변화에 대한 Palmitic Acid LB막의 유기가스 반응특성)

  • 강기호;김정명;장정수;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.317-319
    • /
    • 2000
  • We fabricated the QCM with Langmuir-Blodgett(LB) film deposited at the different subphase pH and investigated the resonant frequency response by the injection of organic gas response. In the $\pi$-A isotherms, the monolayer on the air/water interface had different limiting area per molecule and showed more condensed status as increasing the subphase pH. When palmitic acid LB film was deposited on the QCM, the resonant frequency shift was proportional to the deposited layer and had more resonant frequency shift in the case of the higher pH range as expected. In the resonant frequency for the injection of organic gas, it has been improved in the case of LB film fabricated at the lower subphase pH range and dependant upon the molecular weight of organic gas.

  • PDF