• Title/Summary/Keyword: exhaust ventilation facilities

Search Result 28, Processing Time 0.024 seconds

Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station (소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안)

  • Park, Je-Seop;Han, Dong-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

A Study on the Indoor Air Quality of Public Entertainment Facilities. (공공위락 시설의 실내 공기환경에 관한 연구)

  • 정재국
    • Journal of the Korean housing association
    • /
    • v.9 no.1
    • /
    • pp.143-152
    • /
    • 1998
  • This study aims to suggest ventilation design data for Public Entertainment Facilities in relation to Indoor Air Quality. The concentration of indoor air pollution such as CO, CO2, RH, Radon, HCHO, TSP was investigate, and the reguired ventilation rate of Public Rooms was calculated. As resuits of this study, the following conclusion could be obtained. Field measurement of P.E.F reveals that the concentration of CO2 was mist polluted and higher than IAQ standard, while that of other pollutats did not exceed the standard. In underground the concentration of CO2 increased 1130ppm(2 persons) 2170ppm(4 persons) 1970ppm(6 persons). The CO2 pollution was serions problem in underground more than second floor, in only exhaust ventilation system more than exhaust and supply system.

  • PDF

Comparison of Two Different Smoke Extraction Schemes of Transversely Ventilated Tunnel Fire

  • Rie, Dong-Ho;Kim, Hyung-Taek;Yoo, Ji-Oh;Shin, Hyun-Jun;Yoon, Sung-Wook
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.30-35
    • /
    • 2005
  • In case of tunnel fire, one of the most effective facilities to save lives is the smoke control system. In this study, two different smoke extraction schemes of transversely ventilated tunnel were compared. One is the smoke extraction using the fixed exhaust ports on the false ceiling to achieve the uniform and distributed smoke extraction (uniform exhaust). The other is that using the remote controlled smoke extraction where only vents close to the fire is opened whereas the others are closed to enhance the limitation of the smoke spread (localized exhaust). A number of numerical simulations were performed to find out the optimal smoke extraction rate at each smoke extraction scheme to allow the tunnel users to escape to the safe area without endangering their lives by smoke.

Application Plan of Exhaust Systems in Strengthening Evacuation Safety in Apartment Houses (공동주택의 피난안전성 강화를 위한 배기시스템 활용 방안 연구)

  • Lee, Hyun-Sang;Yoon, Myung-Oh;Lee, Young-Ju;Kim, Jeong-Joon
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.49-57
    • /
    • 2020
  • Apartment buildings are becoming taller and more densely populated with the advancements in science and the development of cities, Consequently, various amenities and safety facilities are being developed to improve the quality of life for residents. However, according to statistics, the number of casualties in apartments accounts for a high proportion of accidents, and the leading cause of the casualties is smoke emitted from fires while sleeping at night. Although it is best to install separate indoor facilities in apartments to minimize smoke damages to occupants, it is useful to minimize the smoke damages by utilizing the installed facilities while reducing the financial burden of occupants. Based on the review, the heat exchanger ventilation system and the kitchen collective exhaust system were selected, and the feasibility of these systems was verified through fire simulation. From the verification results, the available safe egress time improved by 27, 30, and 35 s on the 25th, 35th, 50th floors, respectively.

Environmental Survey to a Ventilation System on the Enclosed Farrowing-nursery Pig House in Winter (무창 분만ㆍ자돈사내에서 환기시스템별 혹한기 환경 조사)

  • 유용희;송준익;정종원;김태일;최희철;양창범;이영윤
    • Journal of Animal Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 2004
  • This study was conducted to improve a ventilation system on the enclosed farrowing-nursery pig house in Korean swine facilities. This survey ventilation system types four major structures. The first structure has planer slot inlet, where air comes in, and these are placed outside the wall under the eave. Then the air from the pig house flows out through the chimney outlet operated by an exhaust fan(V1). The second structure has an air input through the perforated ceiling inlet, then the air from the pig house flows out through the chimney outlet operated by an exhaust fan(V2). Through the circular duct inlet placed inside the juncture of the entry wall, air also comes in(third structure). Then, air from the pig house flows out through the chimney outlet operated by an exhaust fan(V3), Similarly, air comes in through the circular duct inlet placed inside the juncture of the entry wall, but air from the pig house flows out through the side wall by an exhaust fan(V4). Temperature, relative humidity, air velocity and ammonia concentration(NH$_3$) were measured in the interior farrowing-nursery pig house during winter. The results were as follows; Interior temperature at the pig house was not remarkably different in all ventilation systems. The V4 system had low area air velocity, and this was better than other systems. It also had a lower ammonia concentration than other systems. V3 and V4 systems had stable airflow patterns, better than other systems. Therefore, it is suggested that the V3 and V4 ventilation system be applied in the enclosed farrowing-nursery pig house in winter.

  • PDF

A Study of the Indoor Air Quality Improvement for Large Scale Assembly Facilities (건축물의 대공간 집회시설의 실내공기질 개선방안에 관한 연구)

  • Lim, Tae-Sub;Kang, Seung-Mo
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.4
    • /
    • pp.183-190
    • /
    • 2011
  • Lately majority of churches have preferred to enlarge their worship area to both horizontal and vertical axis. According to expand their area which brings more devotees to the limited service area. Transform from a small church into a large church is no longer unprecedented issue in South Korea. As the size of church getting bigger, many unexpected issues become matters. One of the significant problem is that the number of people have experienced either fall a sleep or feel a doziness during their service period. Due to the limited condition for the specific building type such as religion facility(church), IAQ improvements is seriously concerned. Therefore, we are going to examine by using simulation tool, CF, a difference of ventilation efficiency about the location and number of windows, and find the best way of the ventilation efficiency in a multi-stories type church by changing the exhaust pipes location and size. Furthermore, in this thesis, by changing a ceiling height from the existing building to confirm that $CO_2$ have been satisfied for both the ventilation efficiency and IAQ.

A Study of Smoke Exhaust Facility Operation of Subway Platform with Installation of Platform Screen Door (승강장 스크린도어 설치에 따른 배연설비운영에 대한 연구)

  • Rie, Dong-Ho;Ko, Jae-Woong;Kim, Ha-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.35-40
    • /
    • 2006
  • A study on fire phenomena in a subway transit mass station has been carried out as a part of disaster prevention plan at the subway station. The ventilation facilities installed in both the platform and the trackway are designed to convert into a smoke exhaust system in emergency situation, creating such an environment as necessary for evacuation. 3 dimensional Numerical Simulations based on the CFD are carried out using a simulation tool, Fire Dynamic Simulator. Additionally, four different vent modes are made and performances are compared with the original design mode and each other to find better operation of vents at both the platform and the trackway in case of fire. From the result, an vent operational characteristics under the condition of installed PSD is clarified for the effective smoke and heat removal from the platform area compared with non installed PSD.

Assessment of Occupational Health Risks for Maintenance Work in Fabrication Facilities: Brief Review and Recommendations

  • Dong-Uk Park;Kyung Ehi Zoh;Eun Kyo Jeong;Dong-Hee Koh;Kyong-Hui Lee;Naroo Lee;Kwonchul Ha
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.87-95
    • /
    • 2024
  • Background: This study focuses on assessing occupational risk for the health hazards encountered during maintenance works (MW) in semiconductor fabrication (FAB) facilities. Objectives: The objectives of this study include: 1) identifying the primary health hazards during MW in semiconductor FAB facilities; 2) reviewing the methods used in evaluating the likelihood and severity of health hazards through occupational health risk assessment (OHRA); and 3) suggesting variables for the categorization of likelihood of exposures to health hazards and the severity of health effects associated with MW in FAB facilities. Methods: A literature review was undertaken on OHRA methodology and health hazards resulting from MW in FAB facilities. Based on this review, approaches for categorizing the exposure to health hazards and the severity of health effects related to MW were recommended. Results: Maintenance workers in FAB facilities face exposure to hazards such as debris, machinery entanglement, and airborne particles laden with various chemical components. The level of engineering and administrative control measures is suggested to assess the likelihood of simultaneous chemical and dust exposure. Qualitative key factors for mixed exposure estimation during MW include the presence of safe operational protocols, the use of air-jet machines, the presence and effectiveness of local exhaust ventilation system, chamber post-purge and cooling, and proper respirator use. Using the risk (R) and hazard (H) codes of the Globally Harmonized System alongside carcinogenic, mutagenic, or reprotoxic classifications aid in categorizing health effect severity for OHRA. Conclusion: Further research is needed to apply our proposed variables in OHRA for MW in FAB facilities and subsequently validate the findings.

Study on Disaster Prevention in Case of Fire at Subway Platform with Platform Screen Door

  • Rie, Dong-Ho;Yoon, Sung-Wook;Ko, Jae-Woong;Lee, Keun-Oh
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.36-42
    • /
    • 2005
  • A study on fire phenomena in a subway transit mass station has been carried out as a part of disaster prevention plan at the subway station. The ventilation facilities installed in both the platform and the trackway are designed to convert into a smoke exhaust system in emergency situation, creating an environment necessary for evacuation. 3 dimensional Numerical Simulations based on the CFD are carried out using a simulation tool, Fire Dynamic Simulator. Total of six different cases are made and performances are compared each other to find optimal vents operation to ensure safer environment for evacuation at the platform area considering the installation of platform screen door.

Investigation of toxic organic solvent exposure in work places (작업장에서의 유해 유기용제 폭로에 관한 연구)

  • Jo, Young Min;Kang, Sang Wan;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.75-86
    • /
    • 2000
  • The purpose of this work was to document the conditions regarding organic solvent exposure to the workers in paint industry. Air concentrations of organic solvents were measured by passive personal samplers and analyzed by a gas chromatography. Urine samples for hippuric test were also taken from 330 workers who have worked at seven domestic factories for more than two years. Amongst 25 organic elements detected in the indoor environment of working places, toluene was the most common element, and methanol showed the highest mean concentration(18.2ppm). A few elements including methylethyl ketone and toluene partially exceeded the Korean Permissible Exposure Limit. A lack of environmental facilities such as exhaust ventilation, automatic cleaning system, and personal safety devices at present work plaus brings about various occupational diseases.

  • PDF