• 제목/요약/키워드: excitation system

검색결과 1,551건 처리시간 0.03초

DSP를 사용한 중소형 발전기 자동전압 조정기 개발 (The Development of Automatic Voltage Regulation Using DSP for the Small and Middle Generator)

  • 임익헌;류호선;이주현;이재도;송성일
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.305-309
    • /
    • 2003
  • In recent large power plants, the excitation system has the static type, which is characterized by the fast response to increase the transient stability. The high capacity excitation systems developed in KEPRI is either a hot back-up, hybrid hot back-up (analog + digital) or triple modular redundant digital type, both well proven by actual tests and applied in commercial operation. The large excitation systems have been developed taking into consideration the parameters of large scale power plants, resulting in high costs and subsequently are supplied at higher prices. When used at small sized power plants, the cost impact is relatively high. As a countermeasure to such a situation, KEPRI has recently developed a reliable, miniature digital excitation system, which is one-board type, convenient and adequate for low-price, small-sized (0.5MW∼200MW) power plants.

  • PDF

태안 5호기 발전기 여자시스템 분석 및 개체 (Analysis of Tae-an TPP #5 Generator Excitation System and Retrofit)

  • 신만수;이주현;류호선;정태원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1822-1823
    • /
    • 2011
  • If one system were retrofited in complexed several systems, the system has closely analyzed in its function. And, so the system is operating stable after retrofit. Especially, the system is analyzed considerate in not retrofitting totally but retrofitting partially. Now, generator excitation system will be retrofitted partially(that is, retrofitting controller) and the contents is described in this paper.

  • PDF

자기베어링을 이용한 플라이휠 에너지 저장 시스템의 불평형 질량에 의한 베어링의 동적 부하 용량 (A magnetic bearing capacity due to unbalance mass in a flywheel energy storage system)

  • 김봉수;배용채;이욱륜;김희수;이두영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.176-181
    • /
    • 2009
  • In this article, excitation forces due to unbalance mass in a flywheel energy storage system will be discussed, which mainly consists of a composite flywheel and active magnetic bearings and a motor/generator. Unbalance mass causes moments as well as centrifugal forces to the center of the flywheel when the flywheel rotates. The moment excites the flywheel to revolve in the shape of conical revolution and in real operation, the flywheel shows an aspect that conical revolution is a main mode when system failure occurs. Although there are several excitation sources to the flywheel including unbalance mass, an excitation from motor and control issues of the magnetic bearings, we could infer unbalance mass is the main cause of the failure from a comparison between a composite flywheel and a steel flywheel in the same condition. In this of view, excitation forces and moments induced by unbalance mass should be carefully considered in dynamics of the flywheel so that the energy storage system can be operated in more stable conditions.

  • PDF

Optimum location for the belt truss system for minimum roof displacement of steel buildings subjected to critical excitation

  • Kamgar, Reza;Rahgozar, Peyman
    • Steel and Composite Structures
    • /
    • 제37권4호
    • /
    • pp.463-479
    • /
    • 2020
  • Currently, there are many lateral resisting systems utilized in resisting lateral loads being produced in an earthquake. Such systems can significantly reduce the roof's displacement when placed at an optimum location. Since in the design of tall buildings, the minimum distance between adjacent buildings is important. In this paper, the critical excitation method is used to determine the best location of the belt truss system while calculating the minimum required distance between two adjacent buildings. For this purpose, the belt truss system is placed at a specific story. Then the critical earthquakes are computed so that the considered constraints are satisfied, and the value of roof displacement is maximized. This procedure is repeated for all stories; i.e., for each, a critical acceleration is computed. From this set of computed roof displacement values, the story with the least displacement is selected as the best location for the belt truss system. Numerical studies demonstrate that absolute roof displacements induced through critical accelerations range between 5.36 to 1.95 times of the San Fernando earthquake for the first example and 7.67 to 1.22 times of the San Fernando earthquake for the second example. This method can also be used to determine the minimum required distance between two adjacent buildings to eliminate the pounding effects. For this purpose, this value is computed based on different standard codes and compared with the results of the critical excitation method to show the ability of the proposed method.

2차원 정현파 가진을 받는 강체블록의 록킹진동에 있어서의 카오스 (미끄럼이 없는 경우에 대하여) (Chaos on the Rocking Vibration of Rigid Block Under Two Dimensional Sinusodial Excitation (In the Case of No Sliding Occurrence))

  • 정만용;김정호;김지훈;양광영;양인영
    • 한국안전학회지
    • /
    • 제14권2호
    • /
    • pp.42-51
    • /
    • 1999
  • This research deals with the non-linearities associated with impact and sliding for the rocking behavior of rigid block subjected to two dimensional excitation of horizontal and vertical direction. The non-linearities examined of impact between block and base: The transition of two governing rocking equations, the abrupt reduction in kinetic energy associated with impact. In this study, the rocking vibration system of two types are considered for several friction condition. One is the undamped rocking vibration system, disregarding energy dissipation at impact and the other is the damped rocking system, including energy dissipation at impact. The response analysis by non-dimensional rocking equation is carried out for the change of excitation amplitude. The chaos responses were discovered in the wide response region, particularly, in the case of high vertical excitation and their chaos characteristics are examined by Poincare map, power spectra and Lyapunov Exponent. The complex behavior of chaos response, in the phase space, were illustrated by Poincare map. Therefore, Poincare map will be a significant material in order to understand chaos of rocking system.

  • PDF

엑사이머 레이저 여기용 고반복 펄스압축 시스템 개발에 관한 연구 (Development of multi-repetitive Pulse Compression System for excimer laser excitation)

  • 전상영
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.36-38
    • /
    • 1989
  • We have developed Magnetic Pulse Compression System to realize repetitive excimer laser excitation. The principle of this system is to use the large change in permiability owing to the nolinear characteristics of ferro-magnetic material (Metglas2605s-2 metal ribon). Prior to the laser operation, the MPC system was tested with a dummy load (5$\Omega$) and laser head. Laser head has a discharge volume of 1.0 (w) x 2.0 (h) x 20.0(1) cm. This MPC system compressed a 6.2us (FWHM), 80 A pulse into a 0.4us(FWHM), 1.3kA pulse.

  • PDF

선삭에서 공작물 지지조건이 채터진동발생에 미치는 영향 (Influence of Chucking Conditions on the Chatter Vibration Commencing Point in Turning)

  • 신승춘
    • 한국생산제조학회지
    • /
    • 제7권1호
    • /
    • pp.89-94
    • /
    • 1998
  • With increasing demands on automatic and high-capability manufacturing, the dynamic performance of machine tools becomes more and more important. In this paper, the correlation between dynamic compliance of the cutting system and the commencing point of chatter vibration in turning is checked by impulse excitation method and cutting tests for some cutting system. The correlation between chucking conditions of workpiece and the commencing point of chatter vibration is clarified, and it is proven that there is a mutual relations between them. Chatter vibration commenced at certain level of dynamic compliance of the cutting system regardless of the kind of the system. It shows the possibility of dynamic performance test of a lathe by means of impulse excitation method.

  • PDF

Effect of excitation type on dynamic system parameters of a reinforced concrete bridge

  • Wahab, M.M. Abdel;De Roeck, G.
    • Structural Engineering and Mechanics
    • /
    • 제7권4호
    • /
    • pp.387-400
    • /
    • 1999
  • Damage detection in civil engineering structures using the change in dynamic system parameters has gained a lot of scientific interest during the last decade. By repeating a dynamic test on a structure after a certain time of use, the change in modal parameters can be used to quantify and qualify damages. To be able to use the modal parameters confidentially for damage evaluation, the effect of other parameters such as excitation type, ambient conditions,... should be considered. In this paper, the influence of excitation type on the dynamic system parameters of a highway prestressed concrete bridge is investigated. The bridge, B13, lies between the villages Vilvoorde and Melsbroek and crosses the highway E19 between Brussels and Antwerpen in Belgium. A drop weight and ambient vibration are used to excite the bridge and the response at selected points is recorded. A finite element model is constructed to support and verify the dynamic measurements. It is found that the difference between the natural frequencies measured using impact weight and ambient vibration is in general less than 1%.

고속 SRM 구동시스템 설계 (Design of High Speed Drive)

  • 김태형;안영주;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.95-98
    • /
    • 2006
  • This paper proposes high speed SRM drive system for blower with a new 4-level inverter and precise excitation position generator. For the high speed blower, a proper inverter and control method are proposed and the output characteristics are analyzed. In order to get a fast build-up and demagnetization of excitation a current, 4-level inverter system is proposed. The proposed 4-level inverter has additional charge capacitor, power switch and diode in the conventional asymmetric converter. The charged high voltage is supplied to the phase winding for fast current build-up, and demagnetization current is charged to additional capacitor of 4-level inverter. In addition, a precise excitation position generator can reduce turn-on and turn-off angle error according to sampling period of digital control system. The proposed high speed SRM drive system is verified by computer simulation and experimental result.

  • PDF

Robust 제어기를 이용한 발전 여자 시스템 전력 안정도 개선 (PSS Improvement of Generator Excitation System using Robust Controller)

  • 홍현문;최재호;류홍우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.364-367
    • /
    • 1996
  • This paper deals with the design and evaluation of the robust controller for generator excitation system to improve the steady state and transient stabilities. The nonlinear characteristics of the system is treated as model uncertainties, and then the robust control techniques are introduced into the PSS design to take into account these uncertainties at the controller design stage. The performance of the designed controller is examined by extensive non-linear time domain simulation. It is shown that the performance of the robust controller is superior to that of the conventional PSS in all cases studied.

  • PDF