• 제목/요약/키워드: excitation spectrum

검색결과 320건 처리시간 0.029초

평탄화된 여기 스펙트럼에서 켑스트럼 피치 변경법에 관한 연구 (On a Pitch Alteration Technique by Cepstrum Analysis of Flattened Excitation Spectrum)

  • 조왕래
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1998년도 학술발표대회 논문집 제17권 1호
    • /
    • pp.159-162
    • /
    • 1998
  • Speech synthesis coding is classified into three categories: waveform coding, source coding and hybrid coding. To obtain the synthetic speech with high quality, the synthesis by waveform coding is desired. However, it is difficult to apply waveform coding to synthesis by syllable or phoneme unit, because it does not divide the speech into excitation and formant component. Thus it is required to alter the excitation in waveform coding for applying waveform coding to synthesis by rule. In this paper we propose a new pitch alteration method that minimizes the spectrum distortion by using the behavior of cepstrum. This method splits the spectrum of speech signal into excitation spectrum and formant spectrum and transforms the excitation spectrum into cepstrum domain. The pitch of excitation cepstrum is altered by zero insertion or zero deletion and the pitch altered spectrum is reconstructed in spectrum domain. As a result of performance test, the average spectrum distortion was below 2.29%.

  • PDF

이광자현미경 여기 광 파장에 따른 Arabidopsis thaliana 촬영 깊이 및 엽록체 형광 스펙트럼의 변화 (Variations of imaging depth and chloroplast emission spectrum of Arabidopsis thaliana with excitation wavelength in two-photon microscopy)

  • 주용준;손시형;김기현
    • 한국가시화정보학회지
    • /
    • 제12권3호
    • /
    • pp.9-14
    • /
    • 2014
  • Two-photon microscopy (TPM) has been used in plant research as a high-resolution high-depth 3D imaging modality. However, TPM is known to induce photo-damage to the plant in case of long time exposure, and optimal excitation wavelength for plant imaging has not been investigated. Longer excitation wavelength may be appropriate for in vivo two-photon imaging of Arabidopsis thaliana leaves, and effects of longer excitation wavelength were investigated in terms of imaging depth, emission spectrum. Changes of emission spectrum as a function of exposure time at longer excitation wavelength were measured for in vivo longitudinal imaging. Imaging depth was not changed much probably because photon scattering at the cell wall was a limiting factor. Chloroplast emission spectrum showed its intensity peak shift by 20 nm with transition of excitation wavelength from 849 nm or below to 850 nm or higher. Emission spectrum showed different change patterns with excitation wavelengths in longitudinal imaging. Longer excitation wavelengths appeared to interact with chloroplasts differently in comparison with 780 nm excitation wavelength, and may be good for in vivo imaging.

구리 산화물 계열 초전도체에서의 스핀 요동에 의한 자체 에너지의 엘리아시버그 계산 (Eliashberg Calculation of the Momentum-Resolved Self-Energy for the Cuprate Superconductors Induced by the Spin Fluctuations)

  • 홍승환;최한용
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.146-150
    • /
    • 2012
  • We solve the momentum resolved d-wave Eliashberg equation employing the magnetic excitation spectrum from the inelastic neutron scattering on the LSCO superconductors reported by Vignolle et al. The magnetic excitation spectrum exhibits 2 peaks: a sharp incommensurate peak at 18 meV at momentum (${\pi}$, ${\pi}{\pm}{\delta}$) and (${\pi}{\pm}{\delta}$, ${\pi}$) and another broad peak near 40~70 meV at momentum (${\pi}$, ${\pi}$). Above 70 meV, the magnetic excitation spectrum has a long tail that is shaped into a circle centered at (${\pi}$, ${\pi}$) with ${\delta}$. The sign of the real part of the self-energy is determined by the momentum position of the peaks of the magnetic excitation spectrum and bare dispersion. We will discuss the effects of the each component of the magnetic excitation spectrum on the self-energy, the pairing self-energy.

Fluorescence Spectroscopic and Time-Dependent Density-Functional Theory Studies of Diphenylsilane

  • Boo, Bong-Hyun;Lee, Jae-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권3호
    • /
    • pp.993-996
    • /
    • 2012
  • We investigated fluorescence and fluorescence excitation of diphenylsilane (DPS) in a solution and molecular beams in combination with the aid of the DFT method. When the molecule was photoexcited at 250 nm in a cyclohexane solution, normal and excimer fluorescences were observed in the ranges of 260-320 and 330-450 nm, respectively. The fluorescence excitation spectrum indicates that the channel leading to the intramolecular excimer formation is not efficient in comparison with the normal fluorescence. Vibrationally resolved fluorescence excitation spectra were measured for the DPS molecules cooled in pulsed supersonic expansion of He in the range 262.2-271.7 nm, in which we can see several electronic excitation spectra exhibiting the electronic band origins. We found that the simulated absorption spectrum based on the time-dependent densityfunctional theory calculations accords well with the absorption spectrum.

Spectroscopic Evidence for Aggregation of Stilbene Derivatives in Solution

  • Aguiar, M.;Akcelrud, L.;Pinto, M.R.;Atvars, T.D.Z.;Karasz, F.E.;Saltiel, Jack
    • Journal of Photoscience
    • /
    • 제10권1호
    • /
    • pp.149-155
    • /
    • 2003
  • The absorption, fluorescence and fluorescence-excitation spectra of concentrated toluene solutions of selected para substituted trans-stilbene derivatives provide strong evidence for aggregation. A red-shifted fluorescence spectrum peaking at 420 nm gains in intensity as the stilbene concentration is increased. The excitation spectrum of this new emission is well to the red of the normal stilbene absorption spectrum, consistent with the appearance of a red shifted shoulder in the UV spectrum. Formation of a fluorescent ground state dimer (or higher aggregate) is proposed to account for these observations. The presence of polar substituents is crucial to the formation of this ground state complex.

  • PDF

Nonstationary Random Process를 이용한 인공지진파 발생 -설계응답스펙트럼에 의한 파워스펙트럼의 조정- (Generation of Artificial Earthquake Ground Motions using Nonstationary Random Process-Modification of Power Spectrum Compatible with Design Response Spectrum-)

  • 김승훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.61-68
    • /
    • 1999
  • In the nonlinear dynamic structural analysis the given ground excitation as an input should be well defined. Because of the lack of recorded accelerograms in Korea it is required to generate an artificial earthquake by a stochastic model of ground excitation with various dynamic properties rather than recorded accelerograms. It is well known that earthquake motions are generally non-stationary with time-varying intensity and frequency content. Many researchers have proposed non-stationary random process models. Yeh and Wen (1990) proposed a non-stationary modulation function and a power spectral density function to describe such non-stationary characteristics. Satio and Wen(1994) proposed a non-stationary stochastic process model to generate earthquake ground motions which are compatible with design reponse spectrum at sites in Japan. this paper shows the process to modify power spectrum compatible with target design response spectrum for generating of nonstationary artificial earthquake ground motions. Target reponse spectrum is chosen by ATC14 to calibrate the response spectrum according to a give recurrence period.

  • PDF

A STUDY ON THE SPEECH SYNTHESIS-BY-RULE SYSTEM APPLIED MULTIBAND EXCITATION SIGNAL

  • Kyung, Younjeong;Kim, Geesoon;Lee, Hwangsoo;Lee, Yanghee
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.1098-1103
    • /
    • 1994
  • In this paper, we design and implement the Korean speech synthesis by rule system. This system is applied the multiband excitation signal on voiced sounds. The multiband excitation signal is obtained by mixing impluse spectrum and which noise spectrum. We find that the quality of synthesized speech is improved using this application. Also, we classify the voiced sounds by cepstral euclidian distance measure for reducing overhead memory. The representative excitation signal of the same group's voiced sounds is used as excitation signal on synthesis. This method does not affect the quality of synthesized speech. As the result of experiment, this method eliminates the "buzziness" of synthesized speech and reduces the spectral distortion of synthesized speech.ed speech.

  • PDF

Probabilistic study of the influence of ground motion variables on response spectra

  • Yazdani, Azad;Takada, Tsuyoshi
    • Structural Engineering and Mechanics
    • /
    • 제39권6호
    • /
    • pp.877-893
    • /
    • 2011
  • Response spectra of earthquake ground motions are important in the earthquake-resistant design and reliability analysis of structures. The formulation of the response spectrum in the frequency domain efficiently computes and evaluates the stochastic response spectrum. The frequency information of the excitation can be described using different functional forms. The shapes of the calculated response spectra of the excitation show strong magnitude and site dependency, but weak distance dependency. In this paper, to compare the effect of the earthquake ground motion variables, the contribution of these sources of variability to the response spectrum's uncertainty is calculated by using a stochastic analysis. The analytical results show that earthquake source factors and soil condition variables are the main sources of uncertainty in the response spectra, while path variables, such as distance, anelastic attenuation and upper crust attenuation, have relatively little effect. The presented formulation of dynamic structural response in frequency domain based only on the frequency information of the excitation can provide an important basis for the structural analysis in some location that lacks strong motion records.

복합 광원을 갖는 형광 내시경 개발 (Development of the Fluorescence Endoscope System with Dual Light Source Apparatus)

  • 배수진;강욱
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.222-226
    • /
    • 2007
  • We suggest the fluorescence endoscope system that has light source apparatus providing selectable white or excitation light. White light source generates normal color images and is easily switched over to excitation light with the wide spectrum range from 380 nm to 580 nm. 5-ALA is deposited selectively in the abnormal tissue like cancer and causes fluorescence in the red spectrum range when excited by blue spectrum range. In addition, the others of excitation light make the color background image by reflected light to allow accurate orientation and visualization of the abnormal tissue and around. According to clinical studies, the fluorescence intensity contrast that defines the fluorescence intensity of lesion over the fluorescence intensity of around has more than 2 in tumour. Proposed system is useful and objective way in early diagnosis. Furthermore, it can be used in the biopsy for tumour classification at the highest fluorescence intensity point.