• Title/Summary/Keyword: exchange

Search Result 12,891, Processing Time 0.036 seconds

Study on the Preparation of Polyvinyl Chloride Anion Exchange Membrane as a Separator in the Alkaline Water Electrolysis (알칼리 수전해용 격막으로서 폴리염화비닐(polyvinyl chloride) 음이온교환막의 제조에 관한 연구)

  • Park, Jong-Ho;Bong, Soo-Yeon;Ryu, Cheol-Hwi;Hwang, Gab-Jin
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.469-474
    • /
    • 2013
  • An anion exchange membrane was prepared for a separator in the alkaline water electrolysis. An anion exchange membrane was prepared by the chloromethylation and amination of polyvinyl chloride (PVC) used as a base polymer. The membrane properties of the prepared anion exchange membrane such as the membrane resistance and ion exchange capacity were measured. The minimum membrane resistance of the prepared anion exchange membrane was $2.9{\Omega}{\cdot}cm^2$ in 1M NaOH aq. solution. This membrane had 2.17 meq./g-dry-membrane and 43.4% for the ion exchange capacity and water content, respectively. The membrane properties of the prepared anion exchange membrane was compared with that of the commercial anion exchange membrane. The membrane resistance decreased in the order; AHT>IOMAC> Homemade membrane> AHA>APS=AFN. The ion exchange capacity decreased in the order; Homemade membrane>AFN>APS>AHT>AHA>IOMAC.

A Study on the Impact of Real Exchange Rate Volatility of RMB on China's Foreign Direct Investment to Japan

  • He, Yugang
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.6 no.3
    • /
    • pp.24-36
    • /
    • 2018
  • Purpose - From establishing China-Japan diplomatic relations in 1972, the relations between two states has improved a lot, from which makes the government and the people reap much benefit. Owing to this reason, this paper aims at exploiting the impact of exchange rate volatility of RMB on China's foreign direct investment to Japan. Research design and methodology - The quarterly time series data from 2003 to 2016 will be employed to conduct an empirical analysis under the vector error correction model. Meanwhile, a menu of estimated methods such the Johansen co-integration test and the Granger Causality test will be also used to explore the impact of exchange rate volatility of RMB on China's foreign direct investment to Japan. Results - The empirical analysis results exhibit that the real exchange rate has a positive effect on China's foreign direct investment to Japan in the long run. Conversely, the real exchange rate volatility of RMB, the trade openness and the real GDP have a negative effect on China's foreign direct investment to Japan in the long run. However, in the short run, the China's foreign direct investment to Japan, the real exchange rate, the trade openness and the real GDP in period have a negative effect on China's foreign direct investment to Japan in period. Oppositely, the real exchange rate volatility of RMB in period has a positive effect on China's foreign direct investment to Japan in period. Conclusions - From the empirical evidences in this paper provided, it can be concluded that an increase in the exchange rate volatility of RMB can result in a decrease in the China's foreign direct investment to Japan in the long run. However, an increase in the exchange rate volatility of RMB can lead to an increase in the China's foreign direct investment to Japan in the short run. Therefore, the China's government should have a best control of the real exchange rate volatility of RMB so as to improve China's foreign direct investment to Japan.

The Study of Awareness and Practice of Korean Dietitians in Food Exchange Lists , Serving Size and Dietary Guidelines (우리 나라의 식품교환표 , 식품의 서어빙 분량 , 식사지침에 대한 영양사들의 인지도 및 실천에 관한 조사 연구)

  • Lee, Yeong-Nam;No, Seong-Yun
    • Journal of the Korean Dietetic Association
    • /
    • v.7 no.1
    • /
    • pp.9-18
    • /
    • 2001
  • Dietitians in various fields have used food exchange lists for food preparations. However it seems that the present food exchange lists are complicated, thus they cause many problems for dietitians to use in the fields. Therefore this study evaluated to the extent of awareness and utilizations of KDA food exchange lists in dietitians and also collected dietitian's opinions for revising food exchange lists such as serving size, serving calories, and for unifying food guidelines and dietary and dietary guidelines for Korean to one simple guideline. 192 dietitians who presently work in urban and rural areas were recruited and data based on survey were collected. As results, most of dietitians(87.5%) knew well about food exchange lists, but only 7.8% of them always would use food exchange lists for menu planning, 56.3% of dietitians did not use it at all and 34.4% occasionally use it. And 88.0% of dietitians wanted to revise food exchange lists totally or partially, 69.8% of dietitians hoped to amend various calories per one serving in food exchange lists to one serving calorie. The desirable on serving calorie was selected as 100kcal(51%) or 50kcal(38%) by dietitians. The dietitians in this study understood very well dietary guidelines(86.5%) and food guidelines(88.5%) for Korean, and 66.1% dietitians wanted to unify both guidelines. In case of unification of guidelines, dietitians answered that 7-8 items(30%) or 5-6 items(27%) should be included in guideline. In the question about reference value for daily allowance, most dietitians(56%) satisfied with the present various reference values for various generation while 28% of dietitians wanted to change to have one reference value (standard with 2000kcal, adult female). This study will provide basic informations for revising or adjustment of food exchange list and dietary or food guidelines for Korean.

  • PDF

Synthesis of High Loading PONF-g-GMA Anion Exchange Fiber Containing Ion Exchange Resin and Their Adsorption Properties of Vanadium (이온교환 수지를 함유한 PONF-g-GMA High Loading 음이온교환 섬유의 합성 및 바나듐 흡착 특성)

  • Baek, Ki-Wan;Park, Seung-Wook;Nho, Young-Chang;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.4
    • /
    • pp.315-321
    • /
    • 2007
  • Aminated PONF-9-GMA ion exchange fabrics were synthesized by radiation induced graft copolymerization. Hybrid ion exchange fabrics combined with aminated PONF-g-GMA fabrics and anionic ion exchange resin were also fabricated by hot melt adhesion method and then their adsorption properties were investigated. Ion exchange capacity of the hybrid ion exchange fabrics was higher than ion exchange fabric and was lower than bead resin. The maximum value was 4.18 meq/g. Adsorption breakthrough time for vanadium of the hybrid ion exchange fabric was 550 min, which was faster than bead resin but slower than fibrous ion exchanger. The Breakthrough time of the hybrid ion exchange fabrics gets longer with increasing pH. The initial breakthrough time occurred around 400 min with increasing vanadium concentration.

Effect of Partition within Opening on Helium-Air Exchange Flow (개구부에 삽입한 수직평판이 헬륨.공기치환류에 미치는 영향)

  • Tae-il Kang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.797-805
    • /
    • 2003
  • This paper describes experimental investigations of helium-air exchange flow through single opening and partitioned opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a small opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with the opening, for partition ratios H_p/H$_1$$ in the range 0 to 1. where H_p$ and H$_1$ are partition length and height of the opening. respectively. In the case of H_p/H$_1$$ of 0, flow passages of upward flow of the helium and downward flow of the air within the opening are unseparated (bidirectional), and the two flows interfere within the opening. The unseparated flow increases strength of flow resistance and therefore, the exchange flow rate is minimum through range of the partition ratios. Two flow zones, i.e., separated (unidirectional) flow zone and unseparated (bidirectional) flow zone, exist with increasing the partition length. The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at H_p/H$_1$$ of 1. As a result of comparison of the exchange flow rates by changing the partition ratio, the fluids Interference in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

A Study on Ion Exchange Characteristics with Composition and Concentration of Electrolyte, Ratio of Ion Exchange Resin (전해질 성분 및 농도, 이온교환 수지 비율에 따른 이온교환 특성 연구)

  • Ahn Hyun-Kyoung;Rhee In-Hyoung;Yoon Hyoung-Jun;Jeong Hyun-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.727-732
    • /
    • 2006
  • The object of this study was to investigate the influence of composition and concentration of electrolyte, ratio of cation to anion exchange resin of mixed ion exchange column in the performance of ion exchange. Also this work examined the removal capability of suspended solids by ion exchange resin and the effect of particule on the characteristics of ion exchange. Breakthrough time was extended as the amount of ions and particles present in liquid was decreased. The case of anion, the breakthrough sequence is $Cl^{-}, but the case of cation, the breakthrough sequence is $Na^{+}. As for the ratio of cation to anion exchange resin of 1:2, the breakthrough time was prolonged compared with that of 1:1 and 1:3. For the electrolyte of equal concentration containing suspended solid, breakthrough time was contracted less than 20%. It results in the increase in the removal capacity of cation exchange resin. For the higher ratio of cation exchange resin, suspended solids are shorten the cation's breakthrough time so that the runtime of ion exchange resin tower is increased.

  • PDF

Experimental study on water exchange between crack and clay matrix

  • Song, Lei;Li, Jinhui;Garg, Ankit;Mei, Guoxiong
    • Geomechanics and Engineering
    • /
    • v.14 no.3
    • /
    • pp.283-291
    • /
    • 2018
  • Cracks in soil provide significant preferential pathways for contaminant transport and rainfall infiltration. Water exchange between the soil matrix and crack is crucial to characterize the preferential flow, which is often quantitatively described by a water exchange ratio. The water exchange ratio is defined as the amount of water flowing from the crack into the clay matrix per unit time. Most of the previous studies on the water exchange ratio mainly focused on cracked sandy soils. The water exchange between cracks and clay matrix were rarely studied mainly due to two reasons: (1) Cracks open upon drying and close upon wetting. The deformable cracks lead to a dynamic change in the water exchange ratio. (2) The aperture of desiccation crack in clay is narrow (generally 0.5 mm to 5 mm) which is difficult to model in experiments. This study will investigate the water exchange between a deformable crack and the clay matrix using a newly developed experimental apparatus. An artificial crack with small aperture was first fabricated in clay without disturbing the clay matrix. Water content sensors and suction sensors were instrumented at different places of the cracked clay to monitor the water content and suction changes. Results showed that the water exchange ratio was relatively large at the initial stage and decreased with the increasing water content in clay matrix. The water exchange ratio increased with increasing crack apertures and approached the largest value when the clay was compacted at the water content to the optimal water content. The effective hydraulic conductivity of the crack-clay matrix interface was about one order of magnitude larger than that of saturated soil matrix.

Korean Exchange Rate Regime Change and Its Impact on Inflation in Comparison to Japan and Australia (한국 환율제도의 변화가 국내물가상승에 미치는 영향: 일본 및 호주와의 비교분석)

  • Lee, Byung-Joo
    • KDI Journal of Economic Policy
    • /
    • v.28 no.1
    • /
    • pp.193-218
    • /
    • 2006
  • This paper examines the macroeconomic structural differences of the free floating exchange rate regime and the managed float exchange rate regime focusing on the Korean economy, and compares it to the two benchmark economies, Japan and Australia. Korea's shift to the free floating exchange rate regime from the managed float exchange rate regime came after the 1997 economic crisis. Korea's exchange rate policy provides a unique opportunity to study the different behaviors or roles, if any, of managed float and free floating exchange rate regimes. Based on a simple monetary model, we find that the exchange rates of Korea are more sensitive to the economic fundamentals under the free floating regime than under the managed float regime. Impulse response analysis shows that exchange rate pass-through into domestic variables, especially inflation rate, has a bigger short-term impact under the floating regime than under the managed regime. This finding is consistent with the view that the managed (or fixed) regime provides the domestic price stability necessary for the economic growth for the developing countries.

  • PDF

A Study on the Standard for Automatic Exchange of Financial Account Information (정기 금융정보교환을 위한 조세조약 이행규정 고찰)

  • Ryu, Hae-Young;Chae, Soo-Joon
    • Asia-Pacific Journal of Business
    • /
    • v.8 no.2
    • /
    • pp.31-39
    • /
    • 2017
  • Countries around the world have been engaging in automatic exchange of information to tackle tax evasion. The same goal became the basis of the enactment of the Foreign Account Tax Compliance Act (FATCA) by the United States Congress. In order to establish a common approach to counter tax evasion among different countries, the Organization of Economic Cooperation and Development (OECD) released the Standard for Automatic Exchange of Financial Account Information in Tax Matters which consists of the Competent Authority Agreement (CAA) and the Common Reporting Standard (CRS). Specifically, the automatic exchange of information is the exchange of financial account information between Tax Authorities in relevant countries. The law requires this information to be collected by financial institutions around the world for reporting to Tax Authorities. Automatic exchange of Information is made up of two information sharing frameworks: The Foreign Account Tax Compliance Act (FATCA) and The Common Reporting Standard (CRS). Under the automatic exchange of information, all financial institutions must identify accounts held by customers who are foreign tax residents or entities connected to foreign tax residents. Financial institutions must report these to the relevant Tax Authority who will then automatically exchange the account information with the relevant foreign Tax Authorities. Korean government has enacted domestic laws to require financial institutions to collect and report this information and has entered into international agreements to exchange the information with other governments. This paper analyzed the FATCA and CRS rules overall and proposed solutions for the legal and practical issues. This paper contributes to the existing literature on the automatic exchange of information by considering two information sharing frameworks.

  • PDF

Effect of Opening Partition Length on Helium-Air Exchange Flow (개구부 삽입부의 길이가 헬륨 및 공기의 치환류에 미치는 영향)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.192-200
    • /
    • 1999
  • This paper describes experimental investigations of helium-air exchange flow through parti-tioned opening. Such exchange flow may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with partitioned opening for parti-tion rations $H_p/H_1$ in the range 0 to 1 where $H_p$ and $H_1$ are partition length and height of the open-ing respecticely. In the case of $H_p/H_1$ of 0 flow passages of upward flow of the helium and down-ward flow of the air within the opening are unseparated (bidirectional) and the two flows interact exchange flow rate is minimum through range of the partition ratios, Two flow zones i.e. separat-ed(unidirectional)flow zone and unseparated(bidirectional) flow zone exist with increasing the partition. length, The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at $H_p/H_1$ of 1. As a result fo comparison of the exchange flow rates by changing the partition ration the fluids interaction in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

  • PDF