• Title/Summary/Keyword: excess rate

Search Result 699, Processing Time 0.025 seconds

An Experimental Study on the Consolidation Characteristics with Loading Rate (재하속도에 따른 압밀특성에 관한 실험적 고찰)

  • Chae, Jum-Sik;So, Chung-Sup;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1070-1077
    • /
    • 2005
  • The purpose of this study is to establish a proper criterion for the constant rate of loading consolidation(CRLC) test which is a kind of the continuous loading consolidation(CLC) and widely used as alternative methods to the incremental loading consolidation(ILC)test. With those results, the preconsolidation pressure estimated by the CRLC test turned out to be comparatively larger than that of the ILC test, and it is increased in proportion to the applied loading rates. However, the compression index in the CRLC test is less influenced on by the loading rates. The coefficient of consolidation and permeability in the CRLC test are dependent on excess pore pressure ratio mainly. In other words, if the pore pressure ratios are too low, the coefficient of consolidation and permeability become smaller than those of the ILC test. On the other hand, if the excess pore pressure ratios are too high, the coefficient of consolidation and permeability become so larger than those of the ILC test. Therefore, loading rates should be carefully determined to generate proper excess pore pressure ratio inside the soil specimen. From this study, good results are obtained from the CRLC test if the excess pore pressure ratios were in the range of 2.5 to 6.0 %, performed with loading rates between 0.0015 and 0.005 $kgf/cm^2/min$.

  • PDF

A Study on the CdTe Single Crystal Growth by Vertical Bridgman Method (수직 Bridgman 법에 의한 CdTe 단결정 성장에 관한 연구)

  • Lee, Jong-Ki;Kim, Wook;Baik, Hong-Koo
    • Journal of Korea Foundry Society
    • /
    • v.10 no.4
    • /
    • pp.324-331
    • /
    • 1990
  • The single crystal of CdTe was grown by modified 6 zone Bridgman method under the conditions of excess Te and excess Cd. To prevent the constitutional supercooling, the crystal growth was done under the temperature gradient of $17^{\circ}C/cm$ in front of the solid /liquid interface and the growth rate was 3mm/hr. The grain morphologies and the growth mechanism were investigated in excess Te and excess Cd conditions. The grain size of excess Te crystal was increased with an increase of the distance from the tip but, in the case of excess Cd crystal, single crystal was not obtained because of the cavities due to the excess Cd vapors so that the grain size was not increased with an increase of the distance from the tip. In addition, the growth of single crystal of CdTe was done with repeated necking ampoule. It was found that the necking had no effects on the grain selection because the cavities trapped in the necking portion acted as heterogeneous nucleation sites.

  • PDF

Mortality analysis of subtypes in acute ischemic stroke (허혈성 뇌졸중의 유형별 사망률 분석)

  • Ahn, Hyeyun;Park, Kwang-il;Lee, Sinhyung
    • The Journal of the Korean life insurance medical association
    • /
    • v.33 no.2
    • /
    • pp.12-14
    • /
    • 2014
  • Worldwide, stroke is the 2nd or 3rd leading cause of death and a major health problem. Recent advances in medical technology have significantly improved diagnosis and treatment strategies of ischemic stroke. The ischemic stroke subtype is an important determinant of mortality and long-term prognosis of patients. To estimate excess-risks of the ischemic stroke subtype, recently published article, Korean cohort study of stroke, was used as a source article. According to mortality analysis methodology from American academy of insurance medicine, the overall mortality ratio and excess death rate was the highest in patients with SOD, followed by those with CE. Calculated mortality ratio and excess death rate for subtype in this review are SOD, 920%/34‰; CE 267%/34‰; UI 209%/25‰; UM 190%/23‰; UN 188%/15‰; LAA 162%/15‰; LAC 117%/3‰.

  • PDF

NOx Emission Characteristics of 100kW Gas Burner by FGR (100kW용량가스 연소기의 FGR에 의한 Nox발생 특성 연구)

  • Kim, K.L.;Kim, H.J.;Park, B.S.;Kim, J.J.
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.1-7
    • /
    • 2001
  • FGR is one of the most widely used methods of NOx reduction in the combustion process. It was investigated the effect of FGR, excess air ratio, peak temperature and firing rate on NOx emission in this study. 100kW burner and LNG were adopted in this experiment. NOx emission was notably decreased with the increase of FGR, however CO emission was also drastically increased in the 25% FGR. And excess air ratio, peak temperature and firing rate did not affect the NOx emission appreciably in the normal operating condition.

  • PDF

Study on the control of fuel-air ratio ofgas swirl burner (가스 스월버너의 공연비 제어에 관한 연구)

  • Kim, I.K.;Kim, Y.S.;Kim, Y.H.;Kim, K.S.;Kim, J.W.
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.129-138
    • /
    • 1999
  • In this paper, our main issue is that establishing the control procedure of continuous gas flow rate according to combustion fan RPM. For this, first, we decide the optimum operating condition of gas swirl burner through analysis of combustion characteristics - thermal efficiency, combustion efficiency and exhaust gases such as CO, $CO_{2}$, $O_{2}$, $NO_{x}$ and THC. Second, fuel gas flow rate of gas valve is decided with considering excess air ratio and combustion fan RPM is decided by the target of combustion air flow rate. Finally, experimental operating equation is acquired by regression for gas valve and combustion fan. This equation is the control equation of continuous gas flow rate and always gas flow rate is decided by combustion fan operating RPM.

  • PDF

A Survey on Annual Exceedance Trends for the Domestic Permissible Exposure Limit for Benzene (벤젠의 국내 허용기준에 대한 연도별 초과 경향 연구)

  • Lee, Kyunghwa;Kim, Ki-Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.2
    • /
    • pp.144-150
    • /
    • 2018
  • Objectives: The purpose of this study is to analyze the trend for exceedance of the domestic permissible exposure limit of benzene based on a review of the previous literature. Materials and methods: From among 13 chemical substances regulated through a PEL (Permissible Exposure Limit) in the Occupational Safety and Health Act, the research object of this study is benzene. The information utilized is work environment measurement data from 2004 to 2013. The highest level among the concentration data measured at various workplaces was selected as a representative value through the data process. N.D. (Not Detected) data was considered as 1/2 of the LOD (limit of detection). Results: Among the work environment measurement data between 2004 and 2013, the highest number of exceeding workplaces and the excess rate (12 sites and 5.4%) was observed in the 2006 data when applying the current PEL for benzene. When compared with the action level, which means a level one-half of the PEL, 2005's data showed the highest number of exceeding workplaces and greatest excess rate (89 sites & 13.3%). The number of exceeding workplaces and excess rate relative to the PEL for benzene showed an increasing trend in 2004, but tended to decrease after 2007. Conclusions: Based on the results obtained from this study, the exposure level for benzene among domestic workers is not considered to be in a safe phase regardless of the year of work environment measurement. Thus, strict preventive management in workplaces should be provided for reducing exposure to benzene.

Effects of the Co-treatment of Municipal Wastewater with Microwave-Irradiated Excess Sludge on the Performance of the Activated Sludge Process (초단파조사 처리된 잉여슬러지와 하수의 병합처리가 활성슬러지공법의 성능에 미치는 영향)

  • Kim, Nam-Chul;Jang, Myung-Bae;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.304-310
    • /
    • 2007
  • The purpose of this research was to investigate the effects of the co-treatment of municipal wastewater with microwave-irradiated excess sludge on the treatment efficiency and excess sludge production of the activated sludge process. When 250 mL of excess sludge with a MLSS concentration of approximately 2,000 mg/L was microwave-irradiated at $20^{\circ}C$ for $40\sim300$ sec by a microwave oven (2,450 MHz, 700 W), the temperature of the sludge increased at a rate of approximately $20^{\circ}C/min$ and the SCOD, TKN and T-P concentrations of the sludge showed the highest increase in the irradiation time of $40\sim130$ sec. And, the oxygen uptake rate measurement of the sludge microorganism suggested most of the microorganisms in the sludge were destroyed at an irradiation time above 130 sec(above $65^{\circ}C$). When the municipal wastewater and microwave-irradiated excess sludge was co-treated by the activated sludge process, almost no effect was observed in the pH and alkalinity of both the influent and effluent, but the influent concentrations of SS, COD, T-N and T-P increased. Even though the effluent SS, BOD and T-P concentrations showed almost no effect, the COD and TKN concentrations increased. The microbial yield coefficient decreased at a rate of 0.91 g SS/g COD removed as the irradiation ratio increased at a rate of 1 g SS/g SS-day.

A Study on the Environmental Hazard Factors within Children's Play Facilities in Gyeonggi-do Province (경기도 내 어린이놀이터 환경유해인자 오염실태 연구)

  • Won, Jong-Moo;Byun, Joo-Hyeong;Kim, Woong-Soo;Kim, Eun-Ah;Kim, Mun-Jeong;Choi, Yun-Ho;Jo, Ui-Ho;Kim, Jong-Su
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.340-347
    • /
    • 2018
  • Objectives: This study was performed to determine environmental hazard factors and provide more eco-friendly child activity spaces within children's playgrounds installed in Gyeonggi-do Province. Methods: Basic (XRF) and precise (ICP, UV) inspections were conducted. The test items examined were heavy metals and parasite eggs. As a sampling point, painted finish materials (180), synthetic rubber (50), and sand (50) were selected. Results: The total excess rate of heavy metals in the XRF was found to be 7.4% (17/230 points). In a comparison between the basic and precise inspections with 17 excess points, the concentration deviation between the two tests was found to be from 0.01 to 7.7 times, resulting in a large difference. Furthermore, all the excess samples were dual samples. However, the contribution rates of Pb and $Cr^{6+}$ to combined concentration were found to be 85.1 and 14.9% for basic inspection and 91.9 and 8.1% for precise inspections, so there is a similar tendency between the two tests. The excess rate of parasite eggs in sand was expressed at 6%. The excess rate of heavy metals in synthetic rubber was found to be 0%. Conclusion: The reliability of the XRF is low. However, considering the contribution rate of Pb and $Cr^{6+}$ between the two tests, it is likely to be applicable for screening. Dual samples provided high concentrations and excess samples and care should be taken when managing them.

COMBUSTION CHARACTERISTICS OF INHOMOGENEOUS METHANE-AIR MIXTURE IN A CONSTANT VOLUME COMBUSTION CHAMBER

  • Choi, S.H.;Jeon, C.H.;Chang, Y.J.
    • International Journal of Automotive Technology
    • /
    • v.5 no.3
    • /
    • pp.181-188
    • /
    • 2004
  • A cylindrical constant-volume combustion chamber was used to investigate the flow characteristics at the spark electrode gap and the combustion characteristics of an inhomogeneous charge methane-air mixture under several parameters such as stratified pattern, initial charge pressure, ignition time and the excess air ratio of the initial charge mixture. Flow characteristics including mean velocity and turbulence intensity were analyzed by a hot-wire anemometer. The combustion pressure development, measured by a piezo-electric pressure transducer, was used to investigate the effect of initial charge pressure, excess air ratio and ignition times on combustion pressure and combustion duration. It was found that the mean velocity and turbulence intensity had the maximum value around 200-300 ms and then decreased gradually to near-zero value at 3000 ms. For the stratified patterns, the combustion rate under the rich injection (RI) condition was the fastest. Under the initial charge conditions, the second mixture was accompanied by an increase in the combustion rate, and that the higher the mass which is added in the second stage injection, the faster the combustion rate.

The Comparative studies on Diagnostic Results of Yangdorack and EAV -on the 18 Cases of stroke patients- (양도락과 EAV 진단결과(診斷結果)에 대(對)한 상호비교(相互比較) 연구(硏究) -중풍(中風) 환자(患者) 18예(例)를 중심(中心)으로-)

  • Park Kyoung-Jin;Cho Myung-Rae;Yun Yeo-Chung
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.199-209
    • /
    • 1998
  • We compared and studied the results on two diagnostic machines called Yangdorack and EAV on 18 recovering paralytic patients. The results were as folIows ; 1. Patients with weak motor ability showed an average of 25% fewer units of Yangdorack and an average of 49% fewer units of EAV. 2. Deficiency/excess diagnostic results on meridian and internal organs showed 58.5% deficiency and 41.5% excess on the Yangdorack ; 67.9% of decline-degenerative activity and 32.1% of stimulus-inflarrunation activity on the EAV. 3. In the attack of meridian and internal organs in view of the five elements(五行), in rate of deficiency, decline and degeneration of the fire meridian(火經) in view of the highest rate accounts showed 19.5% on the Yangdorack and 20.4% on the EAV. 4. In comparing deficiency/excess results on the Yangdorack with results of decline-degenerative value and stimulus-inflammation value on the EAV, they both showes a 39% rate. 5. In comparing clinical syndromes on the Yangdorack and common diseases on the EAV, they showed a 72% agreement.

  • PDF