• 제목/요약/키워드: evoked potentials

검색결과 187건 처리시간 0.029초

Development of An Apparatus to Control Odorous Stimuli for Olfactory Evoked Responses

  • Min, Byung-Chan;Chung, S.C.;Min, S.W.;Kim, S.K.;Park, S.J.;Kim, C.J.;Shin, J.S.;Kim, J.S.;Lee, D.H.;Sakamoto, K.
    • 산업경영시스템학회지
    • /
    • 제22권53호
    • /
    • pp.69-78
    • /
    • 1999
  • We developed an apparatus for odorous stimuli control to record olfactory evoked potentials from human scalp. The characteristics of the apparatus were as follows. 1. Translating the subjects respiration into electric signals with a sensor attached to the nose. The period and timing of odorous stimuli could be adjusted, so that stimuli could be synchronous with respiration. 2. The respirations translated into electric signals were made constant in amplitude by using an auto gain control circuit. 3. The interstimulus interval of odorous could be arbitrarily selected once every 1 to 9 respirations so that adaptation could be prevented. We obtained olfactory - evoked potentials (OEPs) to odorous stimuli using this apparatus from the site of Cz, whose positive peak latencies were approximately $180{\pm}23ms$. Such response were not recorded if oxygen stimuli were used instead of odorous or with click sounds produced by the switching electromagnetic valve.

  • PDF

유발전위를 이용한 뇌의 시감각 및 체성감각 인지영역 추정기술 (Estimating Neuro-Pathway from Visual and Somatosensory Evoked Potential)

  • 배병훈;김동우
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권4호
    • /
    • pp.481-488
    • /
    • 1994
  • 시각 및 손가락의 전기자극에 의해 머리표면에서 발생하는 유발전위를 검출하여 Source Tracing Method를 이용하여 뇌의 시각인지영역 및 손가락 감각인지영역을 추정하였다. 본 과정에서 유발전위 검출방식은 average method를 이용하였고, 흥분뉴런군에 대한 물리적 모델로 Single Current Dipole Model을 이용하고, 머리기하에 대한 3중구각모델을 이용하여 Forward Problem을 풀었다. Inverse Problem은 current dipole의 6개의 parameter에 대한 Least Square Error Method를 이용하여 신견흥분의 위치를 추정하였다. 이러한 결과와 생리학적으로 밝혀진 시각 및 체성감각 신경로와의 비교결과 유사성이 확인되었다.

  • PDF

개에서 Somatosensory Evoked Potentials (SEPs)을 이용한 척수기능장애의 평가 (Evaluation of Experimentally Induced Lumbar Spinal Cord Injury by Somatosensory Evoked Potentials(SEPs) in Dogs)

  • Lee, Joo-Myoung;Jeong, Seong-Mok;Kweon, Oh-Kyeong;Nam, Tchi-Chou
    • 한국임상수의학회지
    • /
    • 제18권4호
    • /
    • pp.315-323
    • /
    • 2001
  • 본 실험에서는 인공적으로 척수관의 20-50%를 차지하는 이물을 척수관내에 삽입한 후 이물제거 시기에 따라 somatosensory evoked potentials (SEPs) 변화상을 임상증상과 척수조영술을 이용하여 비교 관찰하였다. 실험군은 척수관의 50%를 차지하는 이물을 삽입하여 1주일 후에 제거한 군(II군), 2일 수에 제거한 군(III군), 또 척수관의 20%를 차지하는 이물을 삽입하여 1주일 후에 제거한 군(IV군), 2일 후에 제거한 군(V군), 8주 계속 유지한 군(VI군) 그리고 대조군으로 laminectomy만을 실시한 군(I군)으로 나누었다. 척수관 직경의 50%를 차지하는 큰 이물을 삽입하여 2일간 유지하였다가 제거한 후 관찰한 군(III군), 척수관 직경의 20%를 차지하는 작은 이물을 삽입하여 1주일간 유지하였다가 제거한 후 관찰한 군(IV군), 작은 이물을 삽입하여 2일간 유지하였다가 제거한 후 관찰한 군(V군)에서는 SEPs latency와 임상증상에서 거의 이상이 나타나지 않았다. 작은 이물을 8주간 계속 유지한 군(VI군)에서는 SEPs latency에서는 약간의 이상을 보였으나 임상증상에서 거의 이상이 나타나지 않았다. 척수압박 후 제거한 각각의 군에서 SEPs latency와 임상증상은 비슷한 회복추이를 보였다. 그러나 척수관 직경의 50%를 차지하는 큰 이물을 삽입하여 1주일간 유지하였다가 제거한 후 관찰한 군(II군)에서는 TN1의 SEPs latency는 기록되지 않았으며, 임상적으로 신경증상을 나타내었다. III, Iv 및 V 군에서 TP1과 TN1(T11과 T12사이)은 이물 삽입 직후에는 비정상적으로 기록되었고 처음으로 TP1과 TN1 값이 기록된 날은 이물을 삽입하였다가 제거한 후 각각 6일, 9.5일 및 3.5일째였다. VI군에서 TN1의 유발전위는 이물삽입 후 7.7일째부터 기록되었고 34일째에 정상적인 파형을 보였다. II군에서 TN1의 유발전위는 이물을 삽입하였다가 제거한 후 8주째 까지 기록되지 않았다. I군에서 TN1 값은 laminectomy 후 1일째에 처음으로 기록되었다.

  • PDF

환경자극에 따른 식물의 엽표면 전위포텐셜의 변화 (Changest in Electric Potentials of Leaf Surface Induced by Environmental Stimuli)

  • 손기철;류명화;길미정
    • 생물환경조절학회지
    • /
    • 제9권2호
    • /
    • pp.94-100
    • /
    • 2000
  • 자극 종류(광질, 촛불, 바람, 수온)에 따른 식물의 엽표면 전위 포텐셜의 변화가 조사되었다. 광자극시 광질 및 점.멸간격(5초, 15초, 30초)에 따른 전위포텐셜의 변화는 다르게 나타났으며, 동일한 자극일지라도 아침, 점심, 저녁시간에 따라 그 반응이 달랐다. 또한, 촛불대기, 바람, 5$^{\circ}C$의 저온수 분무 등의 자극도 엽표면 전위포텐셜의 변화를 발생시켰으며, 식물에 따라 반응 패턴이 서로 다르게 나타났다. 결국 같은 자극일지라도 식물종에 따라 엽표면 전위포텐셜의 변화가 다르게 나타났으며, 동일한 식물일지라도 자극의 종류에 따라 서로 다른 반응패턴을 보였다. 한편, 전위포텐셜의 주파수 분석에 따르면, 대부분의 자극에 대해서 10Hz 대역이 다른 주파수 대역보다 높은 값을 나타내었다.

  • PDF

청각 자극용 전기자극기 개발 (Development of Electrical Stimulator for Auditory Stimulation)

  • 허승덕;정동근;김리석;김광년;강명구;김재룡;김기련
    • 음성과학
    • /
    • 제11권3호
    • /
    • pp.201-211
    • /
    • 2004
  • This paper introduces a development of an electrical stimulator for auditory stimulation. The electrical stimulator is useful in neurotological diagnosis, audiological evaluation, candidate selection for cochlear implantation, optimal device selection and decision making of MAP strategy for severe-to-profound hearing impaired persons. The development was based on sound parameters of auditory brainstem responses and auditory electrophysiological characteristic such as effective firing of auditory nerve and recording evoked potentials during refractory period of neuron. Besides pulse parameter could adjustable by programming for more varied electrical stimulation evoked response audiometry. Using the electrical stimulator, electrical square pulse was applied to promontory, and electrically evoked auditory brainstem response and electrically middle latency response were successfully recorded in cats.

  • PDF

Motor and Somato Sensory Evoked Potentials During Intraoperative Surveillance Testing in Patients with Diabetes

  • Lee, Kyuhyun;Kim, Jaekyung
    • International journal of advanced smart convergence
    • /
    • 제9권1호
    • /
    • pp.37-46
    • /
    • 2020
  • Cerebral vascular surgery can damage patients' motor and sensory nerves; therefore, neuromonitoring is performed intraoperatively. Patients with diabetes often have peripheral neuropathy and may be prone to nerve damage during surgery. This study aimed to identify factors that should be considered when diabetic patients undergo intraoperative neuromonitoring during brain vascular surgery and to present new criteria. Methods: In patients with and without diabetes who underwent cerebrovascular surgery (n = 30/group), we compared the intraoperative stimulation intensity, postoperative motor power and sensory, glycated hemoglobin (HbA1c) and glucose levels, and imaging findings. Results: Fasting glucose, blood glucose, and HbA1c levels were 10%, 12.1%, and 9.7%, respectively; they were higher in patients with than in patients without diabetes. Two patients with diabetes had weakness, and 10 required increased Somato sensory evoked potential (SSEP) stimulation, while in 16, motor power recovered over time rather than immediately. The non-diabetic group had no weakness after surgery, but 10 patients required more increased SSEP stimulation. The diabetic group showed significantly more abnormal test results than the non-diabetic group. Conclusion: For patients with diabetes undergoing surgery with intraoperative neuromonitoring, whether diabetic peripheral neuropathy is present, their blood glucose level and the anesthetic used should be considered.

흰쥐의 운동유발전위에 대한 전정신경핵과 연수망상핵의 역할 (Role of the Vestibular and Medullary Reticular Neuclei for the Motor Evoked Potentials in Rats)

  • 이문영;이성호;김재효;박병림;김민선
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제1권6호
    • /
    • pp.603-611
    • /
    • 1997
  • The motor evoked potentials (MEPs) have been advocated as a method of monitoring the integrity of spinal efferent pathways in various injury models of the central nervous system. However, there were many disputes about origin sites of MEPs generated by transcranial electrical stimulation. The purpose of present study was to investigate the effect of major extrapyramidal motor nuclei such as lateral vestibular nucleus (VN) and medullary reticular nucleus (mRTN) on any components of the MEPs in adult Sprague-Dalwey rats. MEPs were evoked by electrical stimulation of the right sensorimotor cortex through a stainless steel screw with 0.5mm in diameter, and recorded epidurally at T9 - T10 spinal cord levels by using a pair of teflon-coated stainless steel wire electrodes with 1mm exposed tip. In order to inject lidocaine and make a lesion, insulated long dental needle with noninsulated tips were placed stareotoxically in VN and mRTN. Lidocaine of $2{\sim}3\;{\mu}l$ was injected into either VN or mRTN. The normal MEPs were composed of typical four reproducible waves; P1, P2, P3, P4. The first wave (P1) was shown at a mean latency of 1.2 ms, corresponding to a conduction velocity of 67.5 m/sec. The latencies of MEPs were shortened and the amplitudes were increased as stimulus intensity was increased. The amplitudes of P1 and P2 were more decreased among 4 waves of MEPs after lidocaine microinjection into mRTN. Especially, the amplitude of P1 was decreased by 50% after lidocaine microinjection into bilateral mRTN. On the other hand, lidocaine microinjection into VN reduced the amplitudes of P3 and P4 than other MEP waves. However, the latencies of MEPs were not changed by lidocaine microinjection into either VN or mRTN. These results suggest that the vestibular and reticular nuclei contribute to partially different role in generation of MEPs elicited by transcranial electrical stimulation.

  • PDF

체감각 자극이 뇌손상 후 체성감각경로의 통합성 회복에 미치는 효과 (The Effect of Somatosensory Stimulation on Recovery of the Integrity of the Somatosensory Pathway after Brain Damage)

  • 김대란
    • 대한간호학회지
    • /
    • 제34권7호
    • /
    • pp.1255-1264
    • /
    • 2004
  • Purpose: The purpose of this study was to determine the effect of a 3-week somatosensory stimulation program on the integrity of the somatosensory pathway of patients with brain damage. Method: The sample consisted of two groups of patients with brain damage matched by Glasgow Coma Scale (GCS) scores and age:8 patients with a mean age of 56.75 years who were treated with somatosensory stimulation, and 8 patients with a mean age of 58.88 years, who were not treated with sensory intervention program. A repeated measures matched-control group design was used to assess functional recovery of the brain. The instrument used in this study was SSEP (somatosensory evoked potentials), a neurophysiological parameter, for the integrity of the somatosensory pathway. Results: The hypothesis that patients with brain damage who were treated with the somatosensory stimulation program will show higher SSEP wave form scores than the non-treatment group was supported (3rd week.: U=13.000, p=.014). Additional repeated measures analysis showed that there were no significant differences in recovery trends between the groups (F=1.945, p=.159). Conclusion: This study demonstrates that a somatosensory stimulation program is effective in promoting recovery of the integrity of the somatosensory pathway of patients with brain damage.

입체 TV 영상(3D) 주시시의 유발전위 (Change of electroencephalograph during 3-dimensional image load)

  • 조암
    • 대한인간공학회지
    • /
    • 제9권2호
    • /
    • pp.29-35
    • /
    • 1990
  • To investigate and analyze of the human brain-wave changes during 3-dimenslonal image load were expected to take not only an important basic information of 3-dimensional TV usage but also 3-dimensional image design. In this experiment, to analyze the difference of visual analyze handing system for which we present the 2- dimensional image having no parallex and 3-dimensional image by visual evoked potentials(VEP). 2-dimensional image and 3-dimensional image displayed on the screen through video. In the test, the time interval was one sec for presentation of stimulus considering united time of visual information of right eye and left eye during watching the 3-dimensional image also display time interval was 200 mesc for each stimulus image. Results are as follow, (1) N190 appears faster 16msec-20msec in the point of Fz, Cz, Pz, Oz when loaded 3D4 angle than 2D3 angle. (2) About of the P300, 3D4 angle(Otherwise, Oz point was reverse) and in the case of no equipment of liquid crystal shutter, there appeared PEAK near the P250. (3) There were 5% significant difference when the liquid crystal shutter was equiped and didn't, Therefore, this phenomenon show the possibility that Liquid crystal shutter influences on Visual Evoked Potentials.

  • PDF