• 제목/요약/키워드: evaporator

검색결과 1,049건 처리시간 0.021초

밀집형 자연냉매 증발기의 열성능에 미치는 불균일 공기유동분포의 영향 (Effects of Air Flow Nonuniformity on the Thermal Performance of a Compact Evaporator for Natural Working Fluids)

  • 박병규;김근오;김무근
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1114-1124
    • /
    • 2001
  • The application of carbon dioxide as an attractive natural working fluid in air cooling and heating system is increasingly important in view of the CFC substitution problem. The thermal performance of compact evaporator was analyzed using section-by-section method. The effects of the two-dimensional nonuniformity of air flow through the evaporator is presented. The detrimental effect of the aid flaw nonuniformity on the thermal performance of the evaporator is found to be significant for many typical applications. It is shown that total heat transfer rate of evaporator using $CO_2$ is higher than that using R134a at the simulation conditions.

  • PDF

Experimental Study on the Performance of Refrigeration System with an Ejector

  • Lee, Won-Hee;Kim, Yoon-Jo;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.201-210
    • /
    • 2002
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were peformed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one of the evaporators) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flow rate ratio of suction fluid to motive fluid increases. The COP of dual-evapo-rator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

착상조건에서 R134a와 R1234yf를 적용한 핀-관 형태의 증발기 성능 비교 (Performance Comparison of Fin-Tube Type Evaporator using R134a and R1234yf under the Frost Condition)

  • 신윤찬;김진현;조홍현
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.5795-5801
    • /
    • 2015
  • 식생활의 향상 및 다양화로 신선한 제품에 대한 요구가 증가하고 있으며, 이에 따라 냉장 및 냉동식품의 저온유통 또한 점차 증가되고 있다. 현재 냉동산업에는 주로 R134a 냉매가 사용되고 있으며 GWP(Global Warming Potential)가 1300으로써 매우 높아 지구온난화에 영향을 미친다. 이를 대체하기 위한 냉매로써 R1234yf 냉매가 있으며, GWP는 4로써 매우 낮다. 냉동탑차 냉장시스템에 사용되는 증발기는 저온조건에서 작동되기 때문에 서리가 형성되어 시스템의 성능을 급격히 감소시킨다. 따라서, 본 연구에서 R134a와 R1234yf 냉매를 작동유체로 사용한 증발기의 성능을 착상조건 하에서 다양한 운전조건으로 분석하였다. 해석결과, 서리성장 조건에서 공기측 입구온도, 상대습도, 증발온도 변화에 대하여 R134a 증발기의 성능이 R1234yf 증발기보다 더욱 민감하게 나타났으며 서리의 성장 또한 R134a 증발기가 더 크게 나타났다.

500 PS SCR 반응기 혼합증발관 길이와 각도 변화에 따른 유동균일도에 대한 수치해석적 연구 (A Study on Numerical Analysis of Flow Uniformity According to Length and Degree Change of Mixed-Evaporator in 500 PS SCR Reactor)

  • 성홍석;이충호;서정세
    • 설비공학논문집
    • /
    • 제28권8호
    • /
    • pp.337-342
    • /
    • 2016
  • A marine SCR System is emerging as an alternative to comply with NOx Tier III Emission standards, a restriction on greenhouse gas from vessels implemented by the International Maritime Organization. The system is greatly affected by the uniformity of the fluid flowing into the catalyst, so the performance of the catalyst of an SCR system needs to be guaranteed. This study conducted research on a mixed evaporator of an SCR system, which is one of the factors affecting the uniformity of the fluid. When the angle of the mixed evaporator is set to $90^{\circ}$, the fluid uniformity is at its highest at 83%, under the condition that the length of the mixed evaporator be 3.5 D. When the length was 3.5 D and less, the fluid uniformity had a tendency to improve relative to the case without a bent pipe. However, a longer mixed evaporator results in a more perfect liquidity development in the pipe with a liquidity distribution similar to the case where no curved pipe is formed in front of the catalyst. A lower angle for the mixed evaporator results in a lower flow uniformity, and a longer length of the mixed evaporator results in a lower difference in the flow uniformity caused by the angle. The flow uniformity can be improved by 6% with a mixed evaporator, which confirmed that all factors applied to an SCR system have a close relationship with the efficiency.

SUDS증발기를 사용한 2중열원 열펌프의 성능해석 (Performance analysis of dual source heat pump system with single unit dual source evaporator)

  • 우정선;이세균;이재효;박효순
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF

히트펌프 건조기용 PF 증발기의 능력과 제습량 실험 연구 (Experimental Study on the Heat Transfer Capacity and Dehumidification Performance of a Parallel Flow Evaporator for a Heat Pump Dryer)

  • 권영철;김기영;이석현;권정태
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.516-521
    • /
    • 2013
  • In the present study, the performances of a fin-tube evaporator and three PF evaporators for a heat pump dryer were experimentally investigated. Among the tested evaporators, the PF3 type evaporator showed the highest values of heat transfer capacity and dehumidification performance, while the fin-tube evaporator had the lowest values. PF3 showed better performance compared to PF1 and PF2, due to the large pin pitch, which leads to more draining for dehumidified water. Also, the $45^{\circ}$ inclined PF evaporator presented better performance than that of the $90^{\circ}$ inclined PF evaporator, owing to its easier draining characteristics. The effect of air velocity was revealed to be quite large. When the air velocity increased by 20%, the heat transfer capacity and dehumidification performance increased 43%/11%, 48%/13% and 54%/23% for PF1, PF2 and PF3, respectively.

홈이 파진 원판증발기를 가진 회전형 히트파이프에 대한 실험적 연구 (An Experimental Study on the Rotating Heat Pipe with a Grooved Disc Evaporator)

  • 권순석;장영석;유병욱
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.122-129
    • /
    • 1993
  • The heat transfer characteristics of the rotating heat pipe with a disc evaporator and a grooved condenser have been investigated by measuring temperature distributions of wall and vapor for various thermal inputs and revolutions per minute. The results showed that the heat transfer coefficients of all types are increased with thermal input and revolutions per minute. The heat transfer coefficient of evaporator with groove (pitch=2.5mm depth=1.5mm) is 25.8% higher than that of evaporator without groove at 500RPM, 150W.

  • PDF

직접접촉식 액화천연가스 기화기의 특성에 관한 연구 (A Study on Characteristics of Direct Contact LNG Evaporator)

  • 한승탁;김종보
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.903-911
    • /
    • 1994
  • This study addresses the phenomena of bubbling, icing, eruption, component varieties of the evaporated natural gas, and volumetric heat transfer coefficients obtained during the operation of a proposed LNG evaporator between LNG and water in direct contact. In the present investigation, the explosive and eruption phenomena within the water column were not observed during the entire operation of the heat exchanger. Compared with the natural gas produced by conventional LNG evaporator, the analysis of the gas produced by the direct contact LNG evaporator shows that nitrogen, methane, and ethane components were reduced by 0.002~0.007mol%(4~14%), 1.6~1.92mol%(1.9~2.3%) and 0.17~1.28mol%(1.1~8.4%) respectively, while the moisture content was rather increased by 0.51~0.76mol%. The maximum volumetric heat transfer coefficient of the direct contact heat exchanger was found to be $21, 800kW/m^3\cdotK$.

멀티형 공조/냉동시스템의 증발기 과열도 제어 (Evaporator Superheat Control of a Multi-type Air-conditioning/Refrigeration System)

  • 김태섭;홍금식;손현철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.712-717
    • /
    • 2001
  • This paper investigates the control problem of evaporator superheat, i.e., the difference between the temperature of the refrigerant at the entrance region of an evaporator and that at the exit region, for multi-type air-conditioning/refrigeration systems. Mathematical equations describing the characteristics of compressor, condenser, evaporator, and electronic expansion valve are first derived. Then, the transfer functions from the current input of the electronic expansion valve to wall temperatures of evaporator tube at two-phase region and superheated region, respectively, are derived. The stability and performance of the closed loop system with a PI controller are analyzed by Nyquist stability criterion. Simulation results are provided.

  • PDF

플레이트 휜 코일형 증발기의 착상에 관한 기초 실험 (Basic Experiment on Frost of Plate Fin Coil Evaporator)

  • 백승문;김창영;한인근;김재돌;윤정인
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.211-216
    • /
    • 1999
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. In this report, a prediction taking into account the change of the fin efficiency due to the growth of the frost layer.

  • PDF