• 제목/요약/키워드: evaporation rates

검색결과 160건 처리시간 0.023초

금속박막의 물리적 성질(I)(증착속도에 따르는 구조변화) (-Physical Properties of Metal Thin Film-(Changes of Structure with Evaporation Rates))

  • 백수현;조현춘
    • 대한전자공학회논문지
    • /
    • 제24권6호
    • /
    • pp.980-985
    • /
    • 1987
  • The thin metal films of Cr, Al, Mn and were made in various evaporation rates with 100\ulcornerthickness under 2x10**-9 bar vacuum level. We analized and discussed the relationships between changes of structure, morphology and sheet resistance, light transmittance for the corresponding evaporation rates. As the evaporation rates were decreased at higher rates, grain sizes of all film were decreased, however both of the sheet resistance and light transmittance were increased. At lower evaporation rate, films of Cr and Cu porduced non-stoi-chiometric oxides but Al an Mn showed up amorphous structures.

  • PDF

증발량 산정을 위한 입사태양복사식 비교 (Comparison of incoming solar radiation equations for evaporation estimation)

  • 임창수
    • 농업과학연구
    • /
    • 제38권1호
    • /
    • pp.129-143
    • /
    • 2011
  • In this study, to select the incoming solar radiation equation which is most suitable for the estimation of Penman evaporation, 12 incoming solar radiation equations were selected. The Penman evaporation rates were estimated using 12 selected incoming solar radiation equations, and the estimated Penman evaporation rates were compared with measured pan evaporation rates. The monthly average daily meteorological data measured from 17 meteorological stations (춘천, 강능, 서울, 인천, 수원, 서산, 청주, 대전, 추풍령, 포항, 대구, 전주, 광주, 부산, 목포, 제주, 진주) were used for this study. To evaluate the reliability of estimated evaporation rates, mean absolute bias error(MABE), root mean square error(RMSE), mean percentage error(MPE) and Nash-Sutcliffe equation were applied. The study results indicate that to estimate pan evaporation using Penman evaporation equation, incoming solar radiation equation using meteorological data such as precipitation, minimum air temperature, sunshine duration, possible duration of sunshine, and extraterrestrial radiation are most suitable for 11 study stations out of 17 study stations.

오리사 바닥재의 수분 증발량 평가 (Assessment of Evaporation Rates from Litter of Duck House)

  • 이상연;이인복;김락우;여욱현;데카노 크리스티나;김준규;최영배;박유미;정효혁
    • 한국농공학회논문집
    • /
    • 제61권5호
    • /
    • pp.101-108
    • /
    • 2019
  • The domestic duck industry is the sixth-largest among the livestock industries. However, 34.3% of duck houses were the duck houses arbitrarily converted from plastic greenhouses. This type of duck house was difficult to properly manage internal air temperature and humidity environment. Humidity environment inside duck houses is an important factor that directly affects the productivity and disease occurrence of the duck. Although the humidity environments of litters (bedding materials) affect directly the inside environment of duck houses, there are only few studies related to humidity environment of litters. In this study, evaporation rates from litters were evaluated according to air temperature, relative humidity, water contents of litters, and wind speed. The experimental chamber was made to measure evaporation rates from litters. Temperature and humidity controlled chamber was utilized during the conduct of the laboratory experiments. Using the measured data, a multi linear regression analysis was carried out to derive the calculation formula of evaporation rates from litters. In order to improve the accuracy of the multi linear regression model, the partial vapor pressure directly related to evaporation was also considered. Variance inflation factors of air temperature, relative humidity, partial vapor pressure, water contents of litters, and wind speed were calculated to identify multicollinearity problem. The Multiple $R^2$ and adjusted-$R^2$ of regression model were calculated at 0.76 and 0.71, respectively. Therefore, the regression models were developed in this study can be used to estimate evaporation rates from the litter of duck houses.

Doping control of Belt Source Evaporation Techniques for Large Size AMOLED

  • Hwang, Chang-Hun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.930-932
    • /
    • 2007
  • In order to understand the doping control for the belt source evaporation, the Alq3 and NPB were codeposited on the Ta plate to re-sublimate. The very slow heating $(0.1^{\circ}C/s)$ of the Ta plate shows the separated rate signals of Alq3 and NPB sublimated from the Alq3-mixed NPB organic film on Ta plate. The ratio of the vapor rates of Alq3 and NPB was measured as same as that of each sublimation rates. Therefore, the doping control of the belt source evaporation is of the ratio of the vaporization rates of host and dopants.

  • PDF

친수성 표면처리가 수평관 외벽의 증발열전달에 미치는 영향 (Effects of Hydrophilic Surface Treatment on Evaporation Heat Transfer at the Outside Wall of Horizontal Tubes)

  • 박노성;황규대;강병하;정진택
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.525-532
    • /
    • 2000
  • Evaporation heat transfer characteristics have been investigated experimentally when distilled water is sprayed on the outside wall of horizontal tubes in a evaporator. This problem is of particular interest in the design of evaporator of an absorption system. Hydrophilic surface treatment was employed to increase the wettability on copper tubes. The results indicate that evaporation heat transfer with hydrophilic tubes is shown to be 25-44% higher than that with bare tubes at evaporation pressure of 31.8 Torr(evaporation temperature$ 30^{\circ}C). Evaporation heat transfer rates of hydrophilic treatment tubes are improved substantially, comparing with those of conventional copper tubes in the wide range of operating parameters, such as water inlet temperatures, water mass flow rates and evaporation pressures.

  • PDF

액체수소 저장용기의 와류 구조 억제 및 증발률 저감을 위한 측벽 rib 설계 (Design of Sidewall Ribs for Suppressing Vortex Structures and Reducing Evaporation Rate in Liquid Hydrogen Storage Tank)

  • 김병건;김현기;박윤정;임민규;박성우;황진율
    • 한국가시화정보학회지
    • /
    • 제22권2호
    • /
    • pp.11-19
    • /
    • 2024
  • We performed numerical simulations on a C-type liquid hydrogen (LH2) storage tank for commercial vehicles to reduce evaporation rates by manipulating vortical structures. Owing to external heat, natural convection occurs inside the tank, leading to the enhanced evaporation of LH2. We observed that the regions of high magnitude vorticity correlate with those of high evaporation rates. Specifically, vortical structures in the side section area show higher vorticity magnitude and evaporation rates compared to those in the midsection area. To suppress these vortical motions, we installed an array of ribs at intervals corresponding to the mean diameter of the vortical structures. As a result, the area occupied by vortical structures in the side section area decreased, leading to a reduction in evaporation speed by approximately 2.3 times. This study elucidates the internal evaporation mechanism in storage tanks from the perspective of flow structures and potentially contributes to minimizing the boil-off rate in cryogenic storage tanks.

Measurement of Evaporation Rates for Lanthanum and Neodymium Chlorides

  • Kwon, S.W.;Lee, Y.S.;Jung, J.H.;Chang, J.H.;Kim, S.H.;Lee, S.J.
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2017년도 추계학술논문요약집
    • /
    • pp.74-74
    • /
    • 2017
  • Electrorefining is a key step in pyroprocessing. The electrorefining process is generally composed of two recovery steps - the deposit of uranium onto a solid cathode and the recovery of the remaining uranium and TRU elements simultaneously by a liquid cadmium cathode. Uranium deposit recovered from the solid cathode is a dendritic powder. It is necessary to separate the adhered salt from the deposits prior to the consolidation of uranium deposit. The adhered salt is composed of lithium, potassium, uranium, and rare earth chlorides. Distillation process was employed for the cathode processing. One of the operation methods is distillation of the salt at low temperature ($900^{\circ}C$), and then melting of the deposit at high temperature to avoid a backward reaction. For the development of the salt distiller, the distillation behavior of the low vapor pressure chlorides should be studied. Rare earth chlorides in the adhered salt of uranium deposits have relatively low vapor pressures compared to the process salt (LiCl-KCl). In this study, the evaporation rates of the lanthanum and neodymium chlorides were measured for the salt separation from electrorefiner uranium deposits in the temperature range of $825{\sim}910^{\circ}C$. The evaporation rate of both chlorides increased with an increasing templerature. The evaporation rate of lanthanum chloride varied from 0.12 to $1.68g/cm^2/h$. Neodymium chloride was more volatile than lanthanum chloride. The evaporation rate of neodymium chloride varied from 0.20 to $4.55g/cm^2/h$. The evaporation rate of both chlorides are more than $1g/cm^2/h$ at $900^{\circ}C$. Even though the evaporation rates of both chlorides were less than that of the process salt, the contents of the lanthanide chlorides were small in the adhered salt. Therefore it can be concluded that $900^{\circ}C$ is suitable for the operation temperature of the salt distiller.

  • PDF

소형저장탱크의 가스발생능력에 관한 연구 (A Study on the Prediction of the Maximum Evaporation Rates from LPG Storage Tanks)

  • 이경식;유광수;조영도;박교식
    • 한국가스학회지
    • /
    • 제10권1호
    • /
    • pp.7-12
    • /
    • 2006
  • 소형저장탱크를 이용한 벌크공급시스템은 LP가스의 공급이 중단되거나 공급량이 부족하지 않도록 LP가스 사용가구의 최대가스소비량을 초과하는 가스량을 발생시켜 공급할 수 있어야 한다. 이때 벌크공급시스템에서 공급할 수 있는 가스량은 소형저장탱크의 가스발생능력이 되며, 소형저장탱크의 선정기준이 된다. 현재 우리나라는 소형저장탱크의 충전량, 연속사용시간 등에 따른 가스발생능력 산정기준이 없어 LP가스 사용가구수에 대하여 적합한 소형저장탱크의 선정이 어려운 상태로서 소형저장탱크의 원활한 보급에 문제가 되고 있다. 본 연구는 소형저장탱크의 선정기준이 되는 가스발생능력을 충전량, 외기온도, 연속사용시간 및 충전조성 등에 따라 산정하여 제시하고자 한다.

  • PDF

대형증발계 증발량의 일 변화 (Short-term Variation in Class A Pan Evaporation)

  • 이부용
    • 한국농림기상학회지
    • /
    • 제4권4호
    • /
    • pp.197-202
    • /
    • 2002
  • A new method is used to estimate the amount of water evaporation from Class A Pan with higher precision and accuracy. The principle of method is to detect the weight change of a buoyant sinker resulting from a change in water level of Class A Pan. A strain-gauge load cell is used to measure the weight change. Field observation of evaporation was done at Pohang Meteorological Station from June 24 to August 4, 2002. By using this new method, it is possible to measure hourly evaporation accurately even under a strong solar radiation and wind disturbance, enabling a direct comparison of evaporation with other meteorological elements. At night, under low humidity and high wind speed conditions, more evaporation was recorded than during daytime. Maximum evaporation rates observed during this period exceed 1.0 mm/hour under the sunny and windy conditions with low humidity. To understand relationships between meteorological elements and latent heat flux at ground level, we suggest intensive held experiments using high accuracy evaporation recording instruments with hourly time interval.

미세폭발을 가진 혼화 이성분 연료 액적의 증발 현상 (Microexplosive Vaporization of Miscible Binary Fuel Droplets)

  • 호잿가세미;백승욱;카심살월칸
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.120-131
    • /
    • 2005
  • The evaporation characteristics of single and multicomponent droplets hanging at the tip of a quartz fiber are studied experimentally at the different environmental conditions under normal gravity. Heptane and Hexadecane are selected as two fuels with different evaporation rates and boiling temperatures. At the first step, the evaporation of single component droplet of both fuels has been examined separately. At the next step the evaporation of several blends of these two fuels, as a binary component droplet, has been studied. The temperature and pressure range is selected between 400 and 700 $^{\circ}C$, and 0.1 and 2.5 MPa, respectively. High temperature environment has been provided by a falling electrical furnace. The initial diameter of droplet was in range of 1.1 and 1.3 mm. The evaporation process was recorded by a high speed CCD camera. The results of binary droplet evaporation show the three staged evaporation. In the the first stage the more volatile component evaporates. The droplet temperature rises after an almost non evaporating period and in the third stage a quasi linear evaporation takes place. The evaporation of the binary droplet at low pressure is accompanied with bubble formation and droplet fragmentation and leads to incomplete microexplosion. The component concentration affects the evaporation behavior of the first two stages. The bubble formation and droplet distortion does not appear at high environment pressure. Nomenclature

  • PDF