• 제목/요약/키워드: evaporation loss

검색결과 163건 처리시간 0.027초

결정질 실리콘 태양전지에 적용하기 위한 도금법으로 형성환 Ni/Cu 전극에 관한 연구 (Investigation of Ni/Cu Contact for Crystalline Silicon Solar Cells)

  • 김범호;최준영;이은주;이수홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.250-253
    • /
    • 2007
  • An evaporated Ti/Pd/Ag contact system is most widely used to make high-efficiency silicon solar cells, however, the system is not cost effective due to expensive materials and vacuum techniques. Commercial solar cells with screen-printed contacts formed by using Ag paste suffer from a low fill factor and a high shading loss because of high contact resistance and low aspect ratio. Low-cost Ni and Cu metal contacts have been formed by using electroless plating and electroplating techniques to replace the Ti/Pd/Ag and screen-printed Ag contacts. Ni/Cu alloy is plated on a silicon substrate by electro-deposition of the alloy from an acetate electrolyte solution, and nickel-silicide formation at the interface between the silicon and the nickel enhances stability and reduces the contact resistance. It was, therefore, found that nickel-silicide was suitable for high-efficiency solar cell applications. The Ni contact was formed on the front grid pattern by electroless plating followed by anneal ing at $380{\sim}400^{\circ}C$ for $15{\sim}30$ min at $N_{2}$ gas to allow formation of a nickel-silicide in a tube furnace or a rapid thermal processing(RTP) chamber because nickel is transformed to NiSi at $380{\sim}400^{\circ}C$. The Ni plating solution is composed of a mixture of $NiCl_{2}$ as a main nickel source. Cu was electroplated on the Ni layer by using a light induced plating method. The Cu electroplating solution was made up of a commercially available acid sulfate bath and additives to reduce the stress of the copper layer. The Ni/Cu contact was found to be well suited for high-efficiency solar cells and was successfully formed by using electroless plating and electroplating, which are more cost effective than vacuum evaporation. In this paper, we investigated low-cost Ni/Cu contact formation by electroless and electroplating for crystalline silicon solar cells.

  • PDF

진공증착중합법을 이용한 6FDA/4-4'DDE 폴리이미드 박막의 제조와 전기적 특성 (Electrical Properties and Preparation of 6FDA/4-4'DDE Polyimide Thin films by Bapor Deposition Polymerization method)

  • 이붕주;김형권;이덕출
    • 한국진공학회지
    • /
    • 제7권3호
    • /
    • pp.229-236
    • /
    • 1998
  • 본 논문에서는 건식중합법에 속하는 진공증착 중합법을 이용하여 내열 절연성 박막 을 제작하고 열경화 온도에 따른 박막의 물성과 전기적 특성에 대해 연구하였다. hexafluoroisopropyliden-2,2-bis[phthalicanhydride](6FDA)와 4,4'-diamino diphenyl ether (DDE) 단량체를 화학량론적으로 최적의 온도인 $214^{\circ}C$, $137^{\circ}C$부분에서 같은 증발율을 보일 때 폴리이미드를 형성하였다. 진공증착 중합된 박막은 열경화에 의해 이미드특성 피이크가 증가되며, 폴리아믹산의 형태에서 폴리이미드 형태로 축중합되어짐을 알 수 있었다. 열경화 온도가 증가함에 따라 박막의 두께는 감소되고 굴절율은 증가된다. 열경화 온도가 $300^{\circ}C$인 경우 최적임을 알았고, 이 온도에서 열경화 시킨 폴리이미드의 전기적 특성에서 100Hz~ 200kHz주파수에서는 3.7의 비유전율을 나타내었고, 유전정접은 0.008의 낮은 값을 보였다. 또한, 30~에서 약1.05$\times$1015$\Omega$cm의 저항율을 보였다.

  • PDF

초음파분무 MOCVD법에 의한 PLZT 박막의 제조 및 전기적 특성 (Electrical properties and preparation of PLZT thin film by MOCVD using ultrasonic spraying)

  • 김기현;이진홍;박병옥
    • 한국결정성장학회지
    • /
    • 제12권4호
    • /
    • pp.184-189
    • /
    • 2002
  • 초음파 분무 MOCVD법에 의한 $(Pb_{0.91}La_{0.09})(Zr_{0.65}Ti_{0.35})O_3$(PLZT) 박막의 제조와 광학적, 전기적 특성을 조사하였다. Pb의 휘발성을 고려하여 0.2M의 precursor에 Pb를 5 wt%, 10 wt%과잉 첨가하였다. ITO-coated glass 기판 위에 산소분위기에서 30분 동안 증착한 후 in-situ 상태의 RTA (rapid thermal annealing) 방식으로 열처리를 하였다. 단일 perovskite상의 결정화 온도는 $600^{\circ}C$였다. Pb를 10 wt% 과잉 첨가한 박막의 최대 광투과율은 520nm에서 약 84%로 광학적 특성이 우수하였으며, 유전상수는 약 308의 값을 가졌고, 누설전류는 Pb를 0, 5 wt% 과잉 첨가한 PLZT 박막보다 낮은 값을 가졌다.

Corrosion behavior of SA508 low alloy steels exposed to aerated boric acid solutions

  • Lim, Yun Soo;Hwang, Seong Sik;Kim, Dong Jin;Lee, Jong Yeon
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1222-1230
    • /
    • 2020
  • The corrosion rates of the reactor pressure vessel materials of SA508 Grade 3 were measured using a weight loss method in aerated boric acid solutions to simulate the evaporation of leaked PWR primary water in an ambient environment. The corrosion behavior and products were examined using X-ray diffraction and electron microscopy. SA508 showed typical general corrosion characteristics. The corrosion rate increased steadily as the boron concentration was increased. As the immersion time elapsed, the corrosion rate slowly or rapidly decreased according to the oxidation reaction of iron. The corrosion rate showed a complicated pattern depending on the temperature; it increased gradually and then rapidly decreased again when reaching a certain transition temperature. The corrosion products of SA508 were found to be FeO(OH), Fe2O3, and Fe3O4. As the boron concentration decreased and the temperature was increased, the formation of Fe3O4 was more favorable as compared to the formation of FeO(OH) and Fe2O3. Consequently, the changes of the corrosion rate and behavior were closely related to the oxidation reaction of iron on the surface. The corrosive damage to SA508 appears to be most severe when the oxidation reaction is such that Fe2O3 forms as a corrosion product.

냉방설비 성능개선 및 에너지 절약을 위한 응결수 활용성 분석 (An analysis on the utility of congealing water to improve efficiency of the air cooling equipment and save energy)

  • 박근수;박영호;유정범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.974-981
    • /
    • 2007
  • Seoul Metro has operated the air cooling equipment established in a machine room of a station building to improve our services focused on our customers who use Seoul Metro during the summer season. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. One of them is loss of efficiency in the air conditioner. The leading cause of this problem is that we use an underground type of the cooling tower. As the machine room of a station building is located in the underground of inner city because of the nature of the subway, it is difficult to establish the cooling tower on the ground. The underground structure of the No. $1{\sim}4$ subway line is unsuitable for the location requirements of the underground type of the one because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. Accordingly, the efficiency of the air conditioning is getting lower and lower. Another problem is too wasteful with water. Each station uses the water over 30 tons every day with waterworks to replenish the cooling tower such as a evaporation, a scattering and a distribution of water. Nevertheless, the more an air conditioner increase, the more the use of water supply increase. For this reason, we can't help wasting an enormous amount of water and discharging the congelation of a low temperature(about $15^{\circ}C$) occurred in a heat exchanger inside an air conditioner. The purpose of this study is to analyze the utility of congealing water to improve efficiency of the air cooling equipment and save energy as a supplementary water for the cooling tower.

  • PDF

Chemisorption of CO on ultrathin epitaxial Ni films n Cu(001) surface

  • E.K. Hwang;J.J. Oh;Lee, J.S.;Kim, S.K.;Kim, J.S.;Kim, J.S.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.182-182
    • /
    • 1999
  • The chemisorption effect of CO on the Ni/Cu(001) surface was investigated using LEED(Low Energy Electron Diffraction) and EELS(Electron Energy Loss Spectrscopy0 under the UHV conditions. after mounting the Cu(001) single crystal in the UHV chamber (base pressure 1$\times$10-10Torr), a clean surface was obtained after a few cycles of repeated Ar+ ion sputtering and annealing at about 40$0^{\circ}C$. The epitaxial thin Ni films were formed on the Cu(001) by evaporation from 99.999% Ni block. The pseudomorphic growth and the orderness of the thin Ni films were monitored by c(2$^{\circ}C$2) LEED pattern. CO adlayers on Ni epitaxial thin films were prepared by dosing pure CO has through a leak valve. After CO adsorpton at room temperature, two pairs of peaks were observed by EELS, whose relative intensities are changed as the film thickness is varied and time is elapsed. These two pair of peaks are likely related to different bonding sites (-top and bridge sites) of C-Ni as well as C-O vibration. Experimental results and qualitative interpretation of the spectra wille be discussed. The possibility of using EELS in combination with probe species (CO) to investigate the nature of thin film growth is mentioned. We will report the experimental result of O2 dosage on Ni film and interaction of CO and O2.

  • PDF

Electrical, Electronic Structure and Optical Properties of Undoped and Na-doped NiO Thin Films

  • Denny, Yus Rama;Lee, Kangil;Seo, Soonjoo;Oh, Suhk Kun;Kang, Hee Jae;Yang, Dong-Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.193.1-193.1
    • /
    • 2014
  • This study was to investigate the electronic structure and optical properties of Na doped into NiO thin film using XPS and REELS. The films were grown by electron beam evaporation with varying the annealing temperature. The relationship between the electrical characteristics with the local structure of NiO thin films was also discussed. The x-ray photoelectron results showed that the Ni 2p spectra for all films consist of Ni 2p3/2 which indicate the presence of Ni-O bond from NiO phase and for the annealed film at temperature above $200^{\circ}C$ shows the coexist Ni oxide and Ni metal phase. The reflection electron energy loss spectroscopy spectra showed that the band gaps of the NiO thin films were slightly decreased with Na-doped into films. The Na-doped NiO showed relatively low resistivity compared to the undoped NiO thin films. In addition, the Na-doped NiO thin films deposited at room temperature showed the best properties, such as a p-type semiconducting with low electrical resistivity of $11.57{\Omega}.cm$ and high optical transmittance of ~80% in the visible light region. These results indicate that the Na doping followed by annealing process plays a crucial in enhancing the electrical and optical properties of NiO thin films. We believe that our results can be a good guide for those growing NiO thin films with the purpose of device applications, which require deposited at room temperature.

  • PDF

감마선 조사가 현미의 수화속도 및 호화양상에 미치는 영향 (Effect of Gamma Irradiation on Water Uptake Rate and Gelatinization of Brown Rice)

  • 이유석;서정식;이주운;변명우
    • 한국식품과학회지
    • /
    • 제36권6호
    • /
    • pp.900-904
    • /
    • 2004
  • 현미의 수화속도를 개선하여 조리적성을 향상시키기 위해 0, 1, 3, 5kGy로 감마선을 조사한 후 수분흡수속도, 이화학적 특성 및 호화특성을 조사하였다. 현미의 수분흡수량은 수침온도 ($20-50^{\circ}C$)와 감마선 조사선량이 증가할 수록 증가하는 경향을 나타내었다. 수침온도 $50^{\circ}C$ 이상에서는 0 kGy와 1 kGy의 수분 흡수량은 큰 차이가 없었지만 5 kGy 조사구는 수침액 중에 가용성성분의 용출로 인해 오히려 수분흡수량이 감소하는 경향을 나타내었다. Amylograph에 의해 측정된 peak viscosity, setback, breakdown 및 consistency는 감마선 조사선량이 증가하면서 유의적으로 감소하는 경향을 보였다. Thermogravimetric analyzer에 의한 열중량분석 결과는 감마선 조사에 의해 고온 ($300^{\circ}C$ 이상)에서의 수분증발이 촉진되는 것으로 조사되었다.

미소 유량 측정을 위한 마이크로 전자 유량 센서의 제작 (Fabrication of a Micro Electromagnetic Flow Sensor for Micro Flow Rate Measurement)

  • 윤현중;김순영;양상식
    • 센서학회지
    • /
    • 제9권5호
    • /
    • pp.334-340
    • /
    • 2000
  • 본 논문에서는 패러데이의 전자기 유도 법칙을 응용한 마이크로 전자 유량 센서를 제작하였다. 마이크로전자 유량 센서는 열 발생이 없고 빠른 응답 속도를 가지고 있고 압력 손실이 없는 장점을 가지고 있다. 전도성 유체가 영구 자석 자장 내의 유로를 통과할 때, 유속에 비례하는 유도 기 전력이 발생하게 되는데, 발생된 기 전력은 유로 벽에 제작된 전극으로 검출된다. 마이크로 전자 유량 센서는 유로를 가지고 있는 두 장의 실리콘 웨이퍼 기판과 전극, 그리고 두 개의 영구 자석으로 구성되어 있다. 두 장의 실리콘 웨이퍼 기판을 이방성 식각 공정으로 유로를 제작하고, Cr/Au를 증착하여 전극을 제작한다. 제작된 마이크로 전자 유량 센서에 유량을 변화시킬 때, 발생되는 기 전력을 측정한다.

  • PDF

은행엽(銀杏葉)의 가토(家兎) 피부(皮膚) 접촉성염증(接觸性炎症) 유발(誘發) 독성물질(毒成物質)에 관(關)한 연구(硏究) (Studies on toxic substances of Gingko leaves inducing contact dermatitis in rabbit)

  • 백병걸;김병수;김선희;안병준
    • 대한수의학회지
    • /
    • 제31권3호
    • /
    • pp.319-327
    • /
    • 1991
  • Gingko biloba is one of the oldest trees on earth. It can be traced 300 million years or more into past. In recent years, this tree has become increasingly popular because of its longevity. Amount of comsumption of Gingko leaves in Korea is increased to produce drugs for blood circulating system's disorder. The workers who work at the company of product drug with Gingko leaves complain pruritus at belt position of west, however toxic substance from extracts of Gingko biloba was carried out to determine what kind of the toxic substance from extract could induce a contact dermatitis by means of histopathological study. Dried leaves of Korean G. biloba were exhaustively extracted with chloroform. The aqueous chloroform residue was extracted with hexane. After evaporation, the hexane extract was passed through a silica gel column chromatography, it was separated into 9 fractions by means of gradient solvent (benzene: acetone/ 98~93 : 2~7%). The 4th and 7th fraction were idendified as bilibol and gingkolic acid by silica gel thin layer chromatography and NMR spectrophotometer. The 4th and 7th fractions of Korean Gingko leaves have an irritant substances which can be induced ear swelling and increased thickness of stratum cornium of rabbit ear exposed with the fractions (3 time/3 day, $100{\mu}l$ of 50mg/ml ethyl alcohol). In the 4th fraction, the substance have induced the surface of ear to swell and mass of unknown cell like inflammatory cell were infiltrated within the stratum corneum, and the 7th fraction have the surface of ear to loss the hairs, and sebaceous gland and follicle of hair were infiltrated with inflammatory cells. and other fractions at all did not induced a certain contact dermatitis and also Deutschen drug of Gingko (named as Gerigeron) have induced the contact dermatitis such as dematitis of Korean Gingko extract.

  • PDF