A Verification Study on the Temperature reduction Effect of Water Mist Injection

  • Kim, Jeong-Ho;Lee, Myung-Hun;Yoon, Yong-Han
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.5-14
    • /
    • 2015
  • Purpose: Recently, according to climate changes, human health is exposed to danger over the world and they influence all fields of human society. Due to these climate changes, humans can be exposed to more frequent and extreme scorching heat and cold wave than the present. As precautions against these urban higher temperature and dryness, diverse methods are being sought. Among them, as measures to form cold islands, the evaporative cooling effect realistic to social and economic conditions was examined. Method: This study was conducted to analyze effects of temperature reduction and cooling according to injection quantity of minute water particles by using a blast sprayer as one of alternatives of alleviation of urban climate changes in outside space in summer. For this, through temperature difference in accordance with the injection quantity per hour of a day, a time zone representing the value of the highest temperature change was analyzed. Also, by analyzing temperature difference according to the injection quantity per daytime insolation, relation of amounts of insolation and evaporation was investigated. Temperature difference in accordance with distances at the highest temperature with the highest value in temperature changes was analyzed. Result: At the study result, about temperature, as injection quantity increase, temperature reduction was significant statistically at the highest temperature with the most insolation. A factor with the highest influence was judged to be the increase of the injection quantity. According to the injection quantity, it was predicted that $3.1^{\circ}C$ temperature reduction of a daily average in case of 0.16L/min, $3.5^{\circ}C$ temperature reduction of a daily average in case of 0.32L/min, and $4.4^{\circ}C$ temperature reduction of a daily average in case of 0.48L/min.

An Experimental Study on the Performance of Outdoor Heat Exchanger for Heat Pump Using $CO_{2}$ ($CO_{2}$이용 열펌프의 실외열교환기 성능에 관한 실험적 연구)

  • Chang Young Soo;Lee Min Kyu;Ahn Young San;Kim Young Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2005
  • The purpose of this study is to investigate the performance of outdoor heat exchanger for heat pump using carbon dioxide. Two types of fin and tube heat exchangers (2 rows for type A and 3 rows for B) are tested. Both heat exchangers have counter-cross flow and 1-circuit arrangement. Test results such as heat transfer rate, pressure drop characteristics and temperature distribution in the heat exchanger are shown with respect to mass flow rate of refrigerant and frontal air velocity For cooling mode, the minimum temperature difference between air and refrigerant of type B is smaller than that of type A by $1^{circ}C$, but the pressure loss of air side is much higher for type B by $29\%$. It is found that a large temperature gradient of carbon dioxide during gas cooling Process Promotes thermal conduction through tube wall and fins which results in degradation of heat transfer performance. For heating mode operation, type B heat exchanger shows higher heat transfer performance compared to type A. However, because pressure loss of refrigerant side of type B is much greater than that of type A, the refrigerant outlet pressure of type B becomes lower than that of type A.

Recovery of Silver and Nitric Acid in the Liquid Waste Resulted from the Mediated Electrochemical Oxidation Process (전기화학적 매개산화공정 폐액에서 은 및 질산의 회수)

  • 최왕규;김영민;이근우;박상윤;오원진
    • Resources Recycling
    • /
    • v.7 no.3
    • /
    • pp.17-26
    • /
    • 1998
  • A study on the recovery of silver and nitric acid in the liquid waste resulted from the mediated electrochemical oxidation(MEO) process was conducted. The removal of silver in the concentrated nitric acid solutions was carried out by the electrodeposition. The removal efficiency more than 98% could be obtained in nitric acid concentrations less than 3 M with the current efficiency of nearly 100%. The experimonts on the evaporation for the recovery of nitric acid were performed as well. At the evaporation factor of 25., the degree of nitric acid recovery in 3.5 M nitric acid solution containing 0.5 to 1.0 mol% NaNO, was 80~90% resulting in 2.8~3.1 M nitric acid. The design factors and operating conditions of the distillation tower were analyzed by using MEH model derived by Maphtali-Sandholm with the throughput of 4 kg/hr for the enrichment of dilute nitric acid solution recovered by evaporation to reuse in the MEO process. The distillation column composed of eleven theoretical stages having the overall tray efficiency of 70% are needed to obtain 1.03 kg/h of 12M nitric acid and 2.97 kg/h of water with feed being introduced to the column at tray 6 from the bottom at the reflux ratio of 0.25, the reboiler with the heat load of 2.7 kW, and the condenser with the cooling load of 0.5 kW.

  • PDF

열처리 조건에 따른 Rubrene 박막의 결정 특성 변화 연구

  • Yun, Yeong-Un;Kim, Song-Hui;Lee, Han-Ju;Kim, Tae-Dong;Lee, Gi-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.124-124
    • /
    • 2009
  • We observed the changes of crystal structure of Rubrene (5,6,11,12-tetraphenylnaphthacene) polycrystal thin films at various in situ substrate temperature and process by scanning electron microscope(SEM), x-ray diffraction (XRD) and near-field microwave microprobe (NFMM). Amorphous rubrene thin film was initially obtained on 200 nm thick $SiO_2/Si$ substrate at 35 $^{\circ}C$ in a vacuum evaporation but in situ long time postannealing at the temperature 80 $^{\circ}C$ transformed the amorphous phase into crystalline. Four heating conditions are followed : (a) preheating (b) annealing (c) preheating, annealing (d) preheating, cooling(35 $^{\circ}C$), annealing. We have obtained the largest polycrystal disk in sample (c). But the highest crytallity and conductivity of the rubrene thin films were obtained in sample (d).

  • PDF

Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression (2유체 미세 물분무 소화노즐의 분무유동 특성)

  • Kim, Bong-Hwan;Choi, Hyo-Sung;Kim, Dong-Keon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

Fabrication of He-Ne ellipsometer and in-situ measurement of effective density variation of $TiO_2$thin films (보급형 He-Ne 타원해석기의 제작과 $TiO_2$ 박막 유효밀도 변화의 in-situ 측정)

  • 김상준;방현용;김상열
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4A
    • /
    • pp.432-437
    • /
    • 1999
  • We have fabricated an in situ ellipsometer operating at He-Ne wavelength. It can be applied to the real-time, in-situ tracking of the ellisometric change which occurs during various sample treatments. As a rotating analyzer type, all optical elements and related parts are designed to share a common hollow-axis configuration, and hence the ellipsometer is compact in shape and simple in design. It is mountable on the spare ports of vacuum chamber with ease. Using this ellipsometer, we observed the effective density variation of previously grown $TiO_2$ thin films by using electron beam evaporation. The packing density of the as-grown film was 82%. When exposed to atomsphere, the micro-void of the film was filled with water vapor. This water-filled $TiO_2$ thin film was subject to heating/cooling cycles in vacuum and the ellipsometric variation versus temperature and cycling number was measured in real time using this in situ He-Ne ellipsometer.

  • PDF

A study on the Water Mist Fire Suppression Performance (미세 물 분무 소화 성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.61-65
    • /
    • 2002
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility. The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was concluded to be cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

  • PDF

Performance Analysis of R744 (Carbon Dioxide) Transcritical Refrigeration System Using Internal Heat Exchanger (내부 열교환기를 이용한 R744용 초임계 냉동사이클의 성능 분석)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.459-465
    • /
    • 2009
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system. These internal heat exchangers(liquid-suction or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as gas cooler pressure and evaporation temperatures, superheat in the evaporator and temperature of gas cooler outlet, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R744, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative capacity index) of this system. With a thorough grasp of these effect, it is necessary to design the R744 compression refrigeration cycle using internal heat exchanger.

A Study on the Fire Suppression Characteristics Using a Water Mist (물분무에 의한 화재제어 특성에 관한 연구)

  • 김성찬;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.261-267
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water droplet, droplet evaporation, and combustion of pool fire. The predicted temperature fields of smoke layer are compared with that of measured data. Numerical results agree with the experimental results within 5$^{\circ}C$ in the case without water mist In the case of fire suppression with water mist, numerical results dose not predict well lot temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with that of measured data. The reason of the discrepancy between predicted and measured data is due to the variation of turning rate during the injection of water mist. The effect of burning rate on the fire suppression is left as future study.

Performance evaluation of PF-condenser adapted to Large Size air-conditioner (대형 에어컨에 적용된 PF열교환기의 성능평가)

  • Cho, J.P.;Choi, Y.H.;Kim, J.H.;Kim, N.H.;Kim, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.1-6
    • /
    • 2000
  • In this study, We evaluated the Performance of PFC and the system performance of large size air-conditioner applying to outdoor condenser. PFC can meet the same cooling capacity in 40.42% of volume to fin-tube condenser. Although the fin-tube condenser requires 3600g of refrigerant charging, PFC requires 1700g, 1800g, 1900g, 2000g refrigerant charging for each 2.0mm, 2.5mm, 3.0mm and 3.5mm fin pitches. Difference of condensing and evaporation pressure is the biggest point 2.0mm fin pitch and the smallest point 2.5mm fin pitch.

  • PDF