• 제목/요약/키워드: evaluation dimension

검색결과 596건 처리시간 0.026초

Preliminary Evaluation of the Activity Concentration Limits for Consumer Goods Containing NORM

  • Jang, Mee;Chung, Kun Ho;Ji, Young Yong;Lim, Jong Myung;Kang, Mun Ja;Choi, Guen Sik
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.101-104
    • /
    • 2016
  • Background: To protect the public from natural radioactive materials, the 'Act on safety control of radioactive rays around living environment" was established in Korea. There is an annual effective dose limit of 1 mSv for products, but the activity concentration limit for products is not established yet. Materials and Methods: To suggest the activity concentration limits for consumer goods containing NORM, in this research, we assumed the "small room model" surrounding the ICRP reference phantom to simulate the consumer goods in contact with the human bodies. Using the Monte Carlo code MCNPX, we evaluate the effective dose rate for the ICRP reference phantom in a small room with dimension of phantom size and derived the activity concentration limit for consumer goods. Results and Discussion: The consumer goods have about 1600, 1200 and $19000Bq{\cdot}kg^{-1}$ for $^{226}Ra$, $^{232}Th$ and $^{40}K$, and the activity concentration limits are about six times comparing with the values of building materials. We applied the index to real samples, though we did not consider radioactivity of $^{40}K$, indexes of the some samples are more than 6. However, this index concept using small room model is very conservative, for the consumer goods over than index 6, it is necessary to reevaluate the absorbed dose considering real usage scenario and material characteristics. Conclusion: In this research, we derived activity concentration limits for consumer goods in contact with bodies and the results can be used as preliminary screening tool for consumer goods as index concept.

인상채득 후 시간경과와 반복주입에 따른 부가중합형 실리콘 인상재의 체적변화 (Evaluation of the Time and Pouring Frequency Dependent Dimensional Stability of Additional Silicone Impression Materials.)

  • 최미라
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.239-248
    • /
    • 2007
  • The accuracy and dimensional stability of rubber impression materials are very important for the fitness of the final restoration. The purpose of this investigation was to evaluate the effects of the storage time and pouring frequency of the additional silicone materials on dimensional stability. Total 30 impressions were made of tooth prepared single crown. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines. Two additional silicone materials(examixfine, aquasil) were included. 15 specimens were made of each impression material and poured by type IV stone over times(1hour, 24hours, 72hours) after mixing. 5 impressions poured after 1 hour were used for second pouring after 24hours and third pouring after 72hours. The same examiner measured each specimen 3 times after lazer scanning. All statistical tests were performed with the level of significance set at 0.05. The results indicated that significant difference at any measuring point of stone dies except the buccolingual and mesiodistal lines of the specimen made at 1hour after mixing with examixfine when measurements at 1hour, 24hours and 72hours were campared. There were significant difference between two impression materials and at every measuring point of stone dies made at second and third pouring. The length of measuring point increased significantly as time passed by and increase of the pouring frequency. However, this results are clinically acceptable except the dies of the third pouring. Under the conditions of this study, the shrinkage rate of the additional silicone rubber impression materials significantly increased as time passed by and increase of the pouring frequency.

일측성 구순열 환자에서 3차원 수치사진측량 스캔과 직접계측 방법의 비교 (Comparison of the 3D Digital Photogrammetry and Direct Anthropometry in Unilateral Cleft Lip Patients)

  • 석효현;권근용;백승학;최태현;김석화
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.11-15
    • /
    • 2013
  • Background: In cleft lip patients, the necessity of a thorough preoperative analysis of facial deformities before reconstruction is unquestioned. The surgical plan of cleft lip patient is based on the information gained from our preoperative anthropometric evaluation. A variety of commercially available three-dimensional (3D) surface imaging systems are currently introduced to us in plastic surgery for these use. However, few studies have been published on the soft tissue morphology of unrepaired cleft infants described by these 3D surface imaging systems. Methods: The purpose of this study is to determine the accuracy of facial anthropometric measurements obtained through digital 3D photogrammetry and to compare with direct anthropometry for measurement in unilateral cleft lip patients. We compared our patients with three measurements of dimension made on both sides: heminasal width, labial height, and transverse lip length. Results: The preoperative measurements were not significantly different in both side of labial height and left side of heminasal width. Statistically significant differences were found on both side of transverse lip length and right side of heminasal width. Although the half of preoperative measurements were significantly different, trends of results showed average results were comparable. Conclusion: This is the first study in Korea to simultaneously compare digital 3D photogrammetry with traditional direct anthropometry in unilateral cleft lip patients. We desire this study could contribute the methodological choice of the many researchers for proper surgical planning in cleft lip reconstruction field.

외부부착 보강된 교량 바닥판 균열폭의 반경험적인 예측 (Semi-Empirical Prediction of Crack Width of the Strengthened Bridge Deck with External Bonding Plastic)

  • 심종성;오홍섭
    • 콘크리트학회논문집
    • /
    • 제14권2호
    • /
    • pp.231-238
    • /
    • 2002
  • 콘크리트 교량 바닥판은 건조수축 및 온도변화 등에 의하여 초기 1차균열이 발생하고, 사용기간 동안 반복되는 차량하중의 크기와 철근 간격 등에 의하여 초기 균열이 이방향 균열로 점차 발전하게 된다. 그러나 현재 사용되고 있는 대부분의 균열 예측식이 일방향 부착-슬립이론에 기초하고 있기 때문에 철근과 보강재의 간격에 따라 변화되는 교량 바닥판의 균열폭을 예측하고 보강된 바닥판의 사용성을 평가하기에는 많은 어려움이 있다. 따라서 본 연구에서는 시험결과에 기초하여 성능향상된 바닥판의 균열 메카니즘을 구명하였으며, 이로부터 사용성을 평가할 수 있는 새로운 균열예측식을 제안하였다. 제안된 균열예측식은 기존 균열식에 비하여 예측결과가 우수한 것으로 나타났으나, 철근 항복 이후 철근과 보강재의 변형률이 급격히 증가할 때 오차범위가 커지는 것으로 나타나 추가적인 연구가 필요한 것으로 판단된다. 따라서 보다나은 균열예측을 위해서는 피로 하중하에서의 철근 항복이후에 대한 추가적인 연구가 필요한 것으로 판단된다.

교합 붕괴 환자의 수직고경거상을 동반한 완전 구강회복 증례 (Full mouth prosthodontic reconstruction on patient with occlusion collapse & decreased vertical dimension)

  • 유현진;최민호;김창현;박영록;강동완
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.115-124
    • /
    • 2003
  • One of the important things in the full mouth reconstruction is the determination of therapeutic position. Centric jaw relation is used as a therapeutic position for the full mouth reconstruction. There are several techniques associated with recording this position. Five clinically acceptable techniques are as follows: 1) Swallowing or free closure, 2) Chin point guidance, 3) Bimanual method 4) Myo-monitor technique, 5) Anterior deprogrammer. Centric relation obtained utilizing the anterior acrylic resin platform in this case. Another important thing in full mouth reconstruction is provisional restoration. Provisional restorations are an excellent diagnostic instrument, especially in full remain esthetics, phonetics, function, parafunction, and dysfunction after evaluation and acceptance through clinical trial with the provisional restorations should be accurately transferred to the final restorations to ensure the same clinical success. Especially, anterior guidance should be accurately transferred to the final restorations. An accurate anterior guidance is critical for optimal esthetics, phonetics, comfort, function, stress minimization, and longevity of teeth and restorations. To record optimum anterior guidance, customized anterior guide table is used in this case. Considering previously mentioned points, we did successive treatment. And it resulted in a better situation esthetically and functionally. Followings are what we cared in treating a patient in this case. 1) Accurate centric relation recording 2) Accurate transference of anterior guidance to the final restorations.

Evaluation of the reproducibility of various abutments using a blue light model scanner

  • Kim, Dong-Yeon;Lee, Kyung-Eun;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.328-334
    • /
    • 2018
  • PURPOSE. To evaluate the reproducibility of scan-based abutments using a blue light model scanner. MATERIALS AND METHODS. A wax cast abutment die was fabricated, and a silicone impression was prepared using a silicone material. Nine study dies were constructed using the prepared duplicable silicone, and the first was used as a reference. These dies were classified into three groups and scanned using a blue light model scanner. The first three-dimensional (3D) data set was obtained by scanning eight dies separately in the first group. The second 3D data set was acquired when four dies were placed together in the scanner and scanned twice in the second group. Finally, the third 3D data set was obtained when eight dies were placed together in the scanner and scanned once. These data were then used to define the data value using third-dimension software. All the data were then analyzed using the non-parametric Kruskal-Wallis H test (${\alpha}=.05$) and the post-hoc Mann-Whitney U-test with Bonferroni's correction (${\alpha}=.017$). RESULTS. The means and standard deviations of the eight dies together were larger than those of the four dies together and of the individual die. Moreover, significant differences were observed among the three groups (P<.05). CONCLUSION. With larger numbers of abutments scanned together, the scan becomes more inaccurate and loses reproducibility. Therefore, scans of smaller numbers of abutments are recommended to ensure better results.

Development of Basic Pattern of Wedding Dress I - Focused on Torso Pattern for Top Dresses -

  • Kwon, Sookhee
    • 한국의류산업학회지
    • /
    • 제20권4호
    • /
    • pp.439-448
    • /
    • 2018
  • This thesis intends to suggest a new wedding dress pattern through researches on history and changes of wedding dress, researches on silhouette and details and analyses of existing basic patterns. In this study, to develop torso patterns of top dresses selected as preferred designs through literature reviews and company surveys, dress form sizes suitable for standard sizes were selected and study basic patterns were made using draping techniques. The study finds characteristics of body type dimension that is changed when wearing brassiere (hereinafter, 'bra') for wedding dress through customer surveys for development of basic patterns of wedding dress. That is, wearing wedding bra was used for the purpose of increasing the bust size and we will evaluate later whether this increase helps completeness of aesthetic impression through wearing evaluation. As the result, it was found out that top torso pattern wearing wedding bra made wearers feel more comfortable and in the aspect of aesthetic impression, it provided impacts on women's beautiful silhouettes. The effects of whether a bra is used or not on changes in patterns were reviewed through the degree of polymerization of finished patterns. When a bra for dresses was worn, the waist front length increased by1.7cm, the bust circumference increased by 2.1cm, and the amount of dart increased by 1.5cm in the patterns. A new torso pattern for top dresses, which will solve problems evaluated in each of the above from the aspect of composition of pattern by a method through analysis of existing basic patterns and multi-dimensional cut patterns wearing wedding bra, will be suggested.

Study on Improving Oriental Medicine Statistical System for Multidimensional Statistical Data

  • Yea, Sang-Jun;Kim, Chul;Kim, Jin-Hyun;Jang, Hyun-Chul;Kim, Sang-Kyun;Song, Mi-Young
    • International Journal of Contents
    • /
    • 제7권3호
    • /
    • pp.13-18
    • /
    • 2011
  • Oriental medicine statistics are essential in research planning, research evaluation, and policy decision based on objective data. However, integrated administration of such statistics is not presently possible in the oriental medicine field, which has been slow in incorporating information communication technology. In an effort to address this problem, the Korea Institute of Oriental Medicine (KIOM) developed an oriental medicine statistical system in 2009, and the system has been offered in the traditional medicine information portal of OASIS. However, according to a 2010 survey targeting OASIS users, those surveys reported that needs for a system where various statistical data can be extracted via an interactive approach to multidimensional data. As a result of an analysis of the functions of the existing system, it was found that it is necessary to array and arithmetically analyze Stats Value, Drill Up & Drill Down, and Pivot. To this end, the existing DB schema should be redesigned. Based on our analysis result, we redesigned the database into a structure that is applicable to the reverse pivot algorithm. We used J2EE/JSP and a Flex framework to design and develop an oriental medicine statistical system that can provide multidimensional statistical data. Considering that the improved oriental medicine statistical system is planned to be offered by OASIS of KIOM, utilization and value of oriental medicine statistical data are expected to be enhanced.

파이로 테크닉 점화기의 노화 성능 평가 (Evaluation of the Aging Effects on the Performance of the Pyrotechnic Igniter)

  • 장승교;류병태
    • 한국추진공학회지
    • /
    • 제1권2호
    • /
    • pp.91-102
    • /
    • 1997
  • 점화기의 성능에 미치는 노화의 영향을 알아보기 위하여 12년, 15년, 16년 경과된 활성 모타로부터 점화기를 분해하여 점화제의 특성 값을 측정하고 점화기의 연소 시험을 하였다. 점화제인 B/$KNO_3$ 펠렛의 수분 함량, 외형 치수, 분쇄 강도, 열 분해 특성, 발열량 등을 측정한 결과, 노화 기간에 비례하여 분쇄 강도는 다소 증가하였고 발열량은 감소하였으나 그 외의 특성 값들은 변화가 없었다. 밀폐 용기 시험과 비활성 모타 연소 시험 결과, 노화된 점화제의 연소 속도는 약 10% 증가하였고, P-t 곡선의 압력을 적분한 값 $P_t$는 약 15% 감소하였다. 연소 속도는 점화제에 균열이 발생할 경우 증가하고 $P_t$는 폭발 열량에 비례하여 감소함을 추론할 수 있었다.

  • PDF

양극산화와 열수처리한 순수 니오비움 금속의 생체활성 평가 (Evaluation of Biocompatibility of Anodized and Hydrothermally Treated Pure Niobium Metal)

  • 원대희;최운재;이민호;배태성
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.79-88
    • /
    • 2005
  • This study was performed to investigate the surface properties of electrochemically oxidized pure niobium by anodic oxide and hydrothermal treatment technique. Niobium specimens of $10\times10mm$ in dimension were polished sequentially from #600, #800, #1000 emery paper. The surface pure niobium specimens were anodized in an electrolytic solution that was dissolved calcium and phosphate in water. The electrolytic voltage was set in the range of 250 V and the current density was 10 $mA/cm^2$. The specimen was hydrothermal treated in high-pressure steam at 300$^{\circ}C$ for 2 hours using an autoclave. Then, specimens were immersed in the Hanks' solution with pH 7.4 at 37$^{\circ}C$ for 30 days. The surface of specimen was characterized by scanning electron microscope(SEM), energy dispersive X-ray microanalysis(EDX), potentiostat/galvanostat test, and cytotoxicity test. The results obtained was summarized as follows; According to the result of measuring corrosion behavior at 0.9% NaCl, corrosion resistance was improved more specimens treated with anodic oxide than in hydrothermal treated ones. The multi-porous oxide layer on surface treated through anodic oxidation showed a structure that fine pores overlap one another, and the early precipitation of apatite was observed on the surface of hydrothermal treated samples. According to the result of EDX after 30 days deposition in Hanks' solution, Ca/P was 1.69 in hydrothermal treated specimens. In MTT test, specimens treated through anodic oxidation and hydrothermal treated ones showed spectrophotometer similar to that of the control group. Thus no significant difference in cytotoxicity was observed (P>0.05).

  • PDF