• 제목/요약/키워드: evacuation time

검색결과 485건 처리시간 0.023초

Evacuation Safety Assessment of Elderly and Children in High-rise Hotels in China

  • Yuanyuan Zhang;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.227-236
    • /
    • 2024
  • Chinese high-rise hotels are large in size, densely populated, and have a lot of combustibles. Once a fire occurs, the fire and smoke spread rapidly, and once a fire accident occurs, it is easy to cause a large number of deaths. Fires have a greater impact on special populations such as elderly and children who move slowly. At present, research mainly focuses on the impact of high-rise building structures on evacuation consequences, but there is very little research on the safety evacuation consequences of elderly people and children in high-rise hotels. This paper focuses on the elderly and children living in high-rise hotels in China. We studied three scenarios in which the elderly and children were placed on high floors, middle floors, and low floors. For the above three scenarios, use pathfinder software for simulation, According to the simulation results, when the elderly and children are mainly concentrated in the lower floors (2nd and 3rd floors), the evacuation time is the shortest, 147 seconds. The evacuation time for the elderly and children on the middle floor (6th and 7th floors) is the longest, at 191.5 seconds. Compared to being placed on high floors, safely staying on low floors for all ages reduces evacuation time by 44.5 seconds and improves evacuation efficiency by 23.24%. The final safety evacuation plan is that in daily safety management, hotels should arrange elderly and children occupants on lower floors as much as possible to reduce the total evacuation time and improve personnel evacuation efficiency. This has great guiding significance in the safety management of high-rise hotels.

사무용 건물의 화재 대피 시뮬레이터 개발에 관한 연구 (A study on the simulator development for fire evacuation of office buildings)

  • 박양수;임동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.543-545
    • /
    • 1999
  • In case of fire in the high-rise buildings, the appropriate and safe evacuation plans for the building residents are very important to minimize the number of casualties. Since the evacuation time usually depends on the floor plans of the buildings, the evacuation plans should be considered while the architectural design is done. Conventionally, the calculation of the evacuation time in the case of fire breakout is based on the approximate mathematical equations which are prone to error. In this study, the simulator model is developed to help the architectural designers to access the more accurate evacuation time and find out the floor plans which offers the most safe evacuation plans for the residents in case of fire.

  • PDF

화재 대피 시뮬레이션 소프트웨어 개발에 관한 연구 (A study on the development of the simulation software for the fire evacuation)

  • 김영헌;임동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.201-205
    • /
    • 2002
  • In case of fire in the buildings, the appropriate and safe evacuation plans for the building residents are very important to minimize the number of casualties. Since the evacuation time usually depends on the stairs and passages of design of the building, the evacuation plans should be considered while the architectural design is done. Conventionally, the calculation of the evacuation time in the case of fire breakout is based on the approximate mathematical equations which are prone to error. In this study, the simulation software is developed to help the architectural designers to access the more accurate evacuation time and find out the floor plans which offers the most sage evacuation plans for the residents in case of fire.

  • PDF

건축물의 피난계획에 관한 기초적 연구 (A Basic Study on the Evacuation Plans of Buildings)

  • 고치원
    • 한국화재소방학회논문지
    • /
    • 제14권4호
    • /
    • pp.1-6
    • /
    • 2000
  • With the "Fire Protection Building Plan" of the Building Center of Japan as a sample, actual evacuation plans used for large scaled and multi-storied buildings are analyzed. Sufficient number of samples were classified into 6 categories. For room evacuation, time to pass through the exit was the most critical point for larger spaces and movement time in the room was the key for smaller evacuation object zone and less number of evacuees. Seen from the location of fire breakout point, it was witnessed that the numbers of crowding at the exits of the fire escape staircase are serious for floor level evacuation. For vertical traffic line, it was actually proved that time to fire escaping floor is problem of higher buildings. It was also proved that special evacuation methods are in practical use in many buildings in japan.

  • PDF

대규모 실내경기장의 성능위주 방재계획에 관한 연구 (A Study on Perfomance Based Evacuation Plan for a Large Indoor-Arena)

  • 최용석;김형근;이규일
    • 설비공학논문집
    • /
    • 제23권10호
    • /
    • pp.687-698
    • /
    • 2011
  • In this study, it was analyzed by a numerical analysis that plan/design considerations for ensuring the spectator safety of large arena audiences in a fire emergency evacuation plan. The latest issue, the 'performance-based design', fire and evacuation plan is important. But nowadays 'Specification-based design' is in common. In evacuation simulation, congestion of exit and aisle is ignored because only evacuation time of large-space is mainly analyzed. In smoke flow,'smoke filling effect' tends to be overrated. From now on, when design a field house, it is needed not 'smoke filling effect' and 'large-space evacuation' analysis, but analyzing 'whole building evacuation time' for ensuring fire evacuation safety of spectator.

A Study on Securing Safety for High Rise Building Fires - Applying Active Fire Escape Systems -

  • Myung Sik, Lee;Sung Jae, Han
    • 국제초고층학회논문집
    • /
    • 제11권3호
    • /
    • pp.227-240
    • /
    • 2022
  • Under the Korean Enforcement Decree of the Building Act, all high story apartment houses more than 5 stories high are mandated to install a fire evacuation system to ensure safe evacuation from fire accidents and providing quick and easy bidirectional escape route when main entrance is blocked by flame or toxic smoke. However, the current fire evacuation system shows a lack of understanding from residents and thus is widely ignored for having insufficient safety functions, especially vis-à-vis fire emergencies. Studies have found that an alternative evacuation method, the escapable fire evacuation system, has been analyzed for safety evaluation compared with the conventional passive fire escape system and can bring efficient and safer solutions, providing high rise residents escape from fire accidents. Evaluation for safety evacuation has been performed by the Fire Dynamics Simulation and applying Pathfinder simulation. This resulted in providing appropriate escape routes within the safety escape time and allowed for people in high rise building fires to get to safety.

피난 모델을 이용한 대형할인매장의 화재시 피난에 관한 연구 (A Study on the Evacuation of People used the evacuation model on Fire in Shopping Mall)

  • 이수경;이상준
    • 한국화재소방학회논문지
    • /
    • 제14권4호
    • /
    • pp.17-22
    • /
    • 2000
  • 대형 할인 마트의 인명 안전 설계를 위해 대상 건물을 선정, 피난로의 피난시간을 계산해 보았다. 피난계산은 두 가지 방법으로 하였는데, 하나는 Computer 피난 모델인 EXODUS이고, 다른 하나는 일본의 피난계산법이다. 연구방법은 모델의 특성연구, 실제 대상 및 시나리오 선정, 그리고 피난 계산을 하였다. 연구결과, 대상 건물은 매우 높은 피난시간이 계산되어 설계된 피난로는 설정된 인구 이상의 용량을 피난시킬 수 없는 부적절한 것임을 알 수 있었다.

  • PDF

대학교육시설(大學敎育施設)의 복도(複道).계단(階段) 폭(幅)과 보행자(步行者) 밀도(密度)가 피난시간(避難時間)에 미치는 영향(影響)에 관한 연구 (A Study on the Evacuation Time According to the Width of Corridor, Stair and Density of Evacuee in University Education Facilities)

  • 이정수;문재호
    • 교육시설
    • /
    • 제17권1호
    • /
    • pp.13-20
    • /
    • 2010
  • The aims of this study are to verify the relationships of evacuee speed and affections to the evacuation time according to the width of corridor and stairs in university education facilities. To achieve these purposes, the present conditions of university education facilities were analyzed, and the evacuation experiments were executed in relation to the width of corridor and stairs. The results of this study are as follows ; (1) The deviations of numbers of residents per stair is very high, and the number and width of stairs, corridors are only depend on the minimum guidelines of building code, not considering the residents' evacuation. (2) The width of corridor and stairs are affects on the evacuation speed and time. The rate of decreasing speed is large in stairs, and also the possibility of danger is increasing depend on the speed and density.

업무용 빌딩의 피난 성능 검토에 관한 연구 (A Study on the Evacuation Performance Review for the Office Buildings)

  • 오혁진;백승태;김우석;이수경
    • 한국화재소방학회논문지
    • /
    • 제17권3호
    • /
    • pp.1-6
    • /
    • 2003
  • 본 연구에서는 특정의 업무용 건축물에 대해서 화재 및 피난 시나리오를 선정하여 FAST 3.1.7(전실화재 예측), SIMULEX 32-bit(피난시간의 예측), JASMINE 3.25d(특정시간까지의 연기 유동성 평가)등의 S/W를 이용하여 이를 평가했으며 그 결과는 다음과 같다. Scenario #1 결과, 화재실에서 전실화재가 발생하지 않았고, 층 피난시간은 25.2 sec로 나타났으며 이때까지의 FAST 3.1.7결과에서 연기층은 2.4m를 기록, 연기유동성 평가에서도 재실자들은 연기의 피해(가시거리, 독성)없이 피난이 완료될 것으로 나타났다. Scenario #2 결과, 화재실에서 6 min 33.2 sec에 전실화재가 발생했으며, 수계산에 의한 피난시간은 5 min 23sec로 나타났다. 본 대상건물에 대해서 선정한 Scenario #1, #2 모두 인명안전설계는 적정하게 설계되었다고 판단된다.

대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석 (Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons)

  • 오수철;공하성
    • 문화기술의 융합
    • /
    • 제8권5호
    • /
    • pp.641-651
    • /
    • 2022
  • 이 연구는 숙박시설이 있는 특정소방대상물 수용인원의 산정 방법에 따라 피난가능시간을 기준으로 피난시뮬레이션을 실시하여 고시원 화재 발생 시 계단 폭의 변화에 따른 피난소요시간을 비교·분석하였다. 현재 숙박시설로 분류하는 고시원(바닥면적 합계 500m2 이상)은 소방시설법, 건축법, 주차장법이 정하는 맹점을 이용, 적은 면적의 대지 위에 고층으로 건축물을 신축하여, 적지 않은 양의 호실을 만들어 대다수의 고시원이 학생과 고시생을 위한 곳이 아닌 변형된 숙박시설의 형태로 변질되어가고 있다. 이는 건축주의 영업이익에 부합하므로 지속적인 증가 추세를 보일 것으로 예상된다. 고시원 피난 시간의 골든타임 확보는 우리 사회의 경제적 약자에 속하는 고시원 재실자의 최후의 보루로 본 연구가 사회적 안전망 구축을 위한 관계법령의 개정 논의에 시발점이 되길 바라며, 피난시뮬레이션 분석의 결과 피난훈련이 실행된 집단과 피난계단의 폭을 200cm로 확장한 경우에 피난소요시간이 가장 적게 나타났으며, 기존 건물의 계단 폭의 변화 없이 피난시뮬레이션을 실시한 피난소요시간이 648.4초와 시나리오 6을 비교하면 최대166.3초가 단축되는 결과를 보였다. 이와 같은 분석 결과를 통하여 고시원의 피난안전성 개선을 위해 피난계단의 폭을 다중이용업소의 안전관리에 관한 특별법의 안전시설 등 종류에 추가하여 관련 법령의 개정에 활용할 수 있는 근거를 마련했다는 점에서 의의가 있다.