• Title/Summary/Keyword: etched surface

Search Result 753, Processing Time 0.028 seconds

Comparison of sandblasted and acid-etched surface implants and new hydrophilic surface implants in the posterior maxilla using a 3-month early-loading protocol: a randomized controlled trial

  • Kim, Hyeong Gi;Yun, Pil-Young;Kim, Young-Kyun;Kim, Il-hyung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.3
    • /
    • pp.175-182
    • /
    • 2021
  • Objectives: In this prospective randomized controlled trial, we measured the primary and secondary stability of two surface-treated implants placed in the posterior maxilla, applied 3-month loading protocols, and compared and analyzed the short-term outcomes of the implants. Patients and Methods: From June 2018 to June 2019, patients with a residual bone height of 4 mm in the posterior maxilla were enrolled and randomly divided into two groups to place SA implants (Osstem Implants, Korea) in Group A and NH implants (Hiossen, USA) in Group B. Finally, 14 implants placed in 13 patients in Group A and 17 implants placed in 14 patients in Group B were analyzed. The measured primary and secondary stability of each implant was represented by implant stability quotient (ISQ), and treatment outcomes were evaluated. Results: Group A consisted of patients with an average age of 62.2 years (range, 48-80 years), and Group B consisted of patients with an average age of 58.1 years (range, 35-82 years). Primary stability was 73.86±6.40 and 71.24±5.32 in Groups A and B, respectively (P=0.222). Secondary stability was 79.07±5.21 in Group A and 78.29±4.74 in Group B (P=0.667). A steep increase in ISQ during the healing period was observed in Group B, though it was not significant (P=0.265). The mean follow-up period was 378.5±164.6 days in Group A and 385.3±167.9 days in Group B. All implants in each group met the success criteria, and the success rate was 100%. Conclusion: Two surface-treated implants placed in the posterior maxilla with greater than 4 mm alveolar bone height exhibited successful one-year treatment outcomes if a primary stability of 65 or higher ISQ was obtained and a 3-month early loading protocol was applied.

The Effect of Surface Sealing on the Microleakage of Class V Composite Resin Restorations (제V급 복합레진 수복물의 표면전색이 미세변연누출에 미치는 효과)

  • Youn, Yeon-Hee;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.359-369
    • /
    • 2007
  • This in vitro study was performed to assess the effect of surface sealing on the microleakage of class V composite resin restorations that underwent several aging treatments. Class V cavities were prepared on the buccal surface of 100 sound extracted premolars and restored with a hybrid light-cured composite resin according to the manufacturer's instructions. They were randomly divided into two groups consisting of 50 samples: group I, without surface sealing, and group II, in which margins were etched and surface sealant was applied. After thermocycling, each group was divided into five subgroups, respectively, to represent the five aging treatments: group A = no further treatment (only thermocycling), B = toothbrushing, C = load cycling, D = toothbrushing followed by load cycling, and E = aging treatment in deionized water for six months. Microleakage was assessed by examining the penetration of 2% methylene blue dye. The following results were obtained: 1. At occlusal and cervical margins in groups without surface sealing, there was no significant difference in microleakage after the several aging treatments (p>0.05). 2. The occlusal margins of groups with surface sealing showed no significant differences after the several aging treatments (p>0.05). 3. In the cervical margins of groups with surface sealing, microleakage significantly increased after load cycling or aging in deionized water for six months (p<0.05). 4. The no-further-treatment group and the toothbrushing group with surface sealing showed less microleakage than the corresponding groups without surface sealing (p<0.05). 5. The surface-sealed groups with load cycling or aging in deionized water showed no significant difference in microleakage to the corresponding groups without surface sealing (p>0.05). In conclusion, the results of this study suggest that the surface sealant infiltrating through the gap of the cervical margin exerted a positive effect on microleakage at the initial stage, but the effect was not sufficient to overcome the stress generated by the cuspal flexure during occlusal loading and water absorption.

  • PDF

EFFECTS OF ACID ETCHING TIMES ON ENAMEL SURFACE MORPHOLOGY AND SHEAR BOND STRENGTH OF ORTHODONTIC ATTACHMENT TO ENAMEL (산부식시간이 법랑질 표면 부식형태와 교정장치의 전단접착강도에 미치는 영향에 관한 연구)

  • Nahm, Dong-Seok;Suhr, Cheong-Hoon;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.771-779
    • /
    • 1997
  • The purpose of this in vitro study was to evaluate the effects of different acid etching times on the enamel surface morphology, shear bond strength and debonding failure mode of orthodontic attachment. Ninety six extracted human mandibular premolars were divided into eight groups of twelve teeth. The buccal surfaces were etched with $37\%$, phosphoric acid for 5, 10, 15, 30, 45, 60, 90 and 120 seconds, respectively. Two teeth from each group were used for scanning electron microscope examination. On the etched buccal surfaces of remaining teeth, orthodontic attachments(lingual buttons) were bonded with light cured orthodontic adhesive. Twenty foot hours after bonding, a Instron universal testing machine was used to determine shear bond strength of orthodontic attachment to enamel. After debonding, bases of orthodontic attachments and enamel surfaces were examined under stereoscopic microscope to determine failure mode. Statistical analysis of the data was carried out with one nay ANOVA and Duncan's multiple range test The results were as follows; 1. There was no statistically significant difference in shear bond strengths between the various etching times(p<0.05). 2. The failure modes of orthodontic attachments had some differences. In 5, 10 and 15 seconds etching groups, the percentage of adhesive/enamel interface failure was higher than that of adhesive/attachment interface failure. On the contrary, in 30, 45, 60, 90 and 120 seconds etching groups, the results were reversed. 3. The etching patterns of enamel surfaces had a great variation. So, we could not find any correlation between etching pattern and bond strength. 4. The findings in this study indicate that in vitro reduction of the etching me to 5 seconds maintains clinically acceptable bond strength. However, further study is required to determine the cause of failure mode in 5, 10 and 15 seconds groups.

  • PDF

Effect of Er:YAG lasing on the dentin bonding strength of two-step adhesives (2단계 접착제의 상아질 결합강도에 대한 Er:YAG 레이저 조사 영향)

  • Song, Byeong-Choon;Cho, Young-Gon;Lee, Myung-Seon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.409-418
    • /
    • 2011
  • Objectives: The purpose of this study was to compare the microshear bond strength (${\mu}$SBS) and bonding interfaces of two-step total-etching and self-etching adhesive systems to three etch types of dentin either the acid etched, laser etched or laser and acid etched. Materials and Methods: The occlusal dentinal surfaces of thirty human molars were used. They were divided into six groups: group 1, 37% $H_3PO_4$ + Single Bond 2 (3M ESPE); group 2, Er:YAG laser (KEY Laser 3, KaVo) + Single Bond 2; group 3, Er:YAG laser + 37% $H_3PO_4$ + Single Bond 2; group 4, Clearfil SE Primer + Bond (Kuraray); group 5, Er:YAG laser + Clearfil SE Bond; group 6, Er:YAG laser + Clearfil SE Primer + Bond. The samples were subjected to ${\mu}$SBS testing 24 hr after bonding. Also scanning microscopic evaluations were made on the resin-dentin interfaces of six specimens. Results: The ${\mu}$SBS of group 2 was significantly lower than that of groups 1 and 3 in Single Bond 2 (p < 0.05). There were significant differences among the uSBS of groups 4, 5, and 6 in Clearfil SE Bond (p < 0.05). Very short and slender resin tags were observed in groups 2 and 5. Long and slender resin tags and lateral branches of tags were observed in groups 3 and 6. Conclusions: Treatment of dentin surface using phosphoric acid or self-etching primer improved the adhesion of Er:YAG lased dentin.

SHEAR BOND STRENGTH OF REPAIRED COMPOSITE RESIN RESTORATIONS (수리된 복합레진 수복물의 전단결합강도 연구)

  • Choi, Soo-young;Jeong, Sun-Wa;Hwang, Yun-Chan;Kim, Sun-Ho;Yun, Chang;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.569-576
    • /
    • 2002
  • This study was peformed to evaluate the interfacial shear bond strength of base (direct and indirect) and repair composites with aging and surface treatment methods. Direct composite resin specimens ($Charisma^{\circledR}$, Heraeus Kulzer, Germany) were aged for 5 min, 1 hour, 24 hours, and 1 week in $37^{\circ}C$ distilled water before surface treatment, and then divided into five groups Group 1, grinding; Group 2, grinding and application of bonding agent, Group 3, grinding, etching with 37% phosphoric acid for 30sec, and application of bonding agent, Group 4, grinding, etching with 37% phosphoric acid for 30sec, silane treatment, and application of bonding agent ; Group 5, grinding, etching with 4% hydrofluoric acid for 30sec. silane treatment, and application of bonding agent. Indirect composite resin specimens ($Artglass^{\circledR}$, Heraeus Kulzer, Germany) were aged for 1 week in $37^{\circ}C$ distilled water and divided into seven groups Group 1 - Group 5, equal to Charisma specimens; Group 6, grinding, etching with 37% phosphoric acid for 60sec, silane treatment, and application of bonding agent; Group7, grinding, etching with 4% hydrofluoric acid for 60 sec, silane treatment, and application of bond-ing agent. The repair material($Charisma^{\circledR}$) was then added on the center of the surface (5 mm in diameter. 5 mm in height). The shear bond strength was tested and the data was analyzed using one-way ANOVA and the Student- Newman-Keuls test. The following conclusions were drawn. 1 The shear bond strength of $Charisma^{\circledR}$ specimens aged for 1 hour was significantly higher in Group 2 and Group 5 than in Group 1 (p<0.05), and that of $Charisma^{\circledR}$ specimens aged for 1 week was signifi-cantly higher in Group 3 and Group 5 than in Group 1 (p<0.05). No significant difference was found in the bond strength of specimens aged for 5 min and 24 hours. 2. In Group 2 of the $Charisma^{\circledR}$ specimens, there was significant difference between the bond strength of 24 hours and that of 1 week (p<0.05). 3. In Group 4 of the $Charisma^{\circledR}$ specimens, the shear bond strength of specimens aged for 24 hours was significantly higher than the others(p<0.05) 4. There was no significant difference between the shear bond strength of the $Artglass^{\circledR}$ specimens, 5. Most of the $Charisma^{\circledR}$ specimens showed cohesive fractures. Artglass^{\circledR}$ specimens that were etched with acid (phosphoric or hydrofluoric) for 30 sec showed more cohesive fractures.

Alternative Pretreatment Methods for Resin Infiltration in Primary Anterior Teeth (유전치 Resin Infiltration을 위한 표면처리 방법의 대안)

  • Lee, Eungyung;Shin, Jonghyun;Kim, Jiyeon;Jeong, Taesung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.2
    • /
    • pp.179-184
    • /
    • 2018
  • Resin infiltration has been used as a treatment option for the management of early caries lesions recently. However, the etching procedure with hydrochloric acid might be somewhat stressful for the clinicians due to safety problem especially for young children, leading to less utility. This study aims at searching for some alternative surface pretreatment methods of resin infiltration for the early caries lesions in primary anterior teeth by comparing penetration depth of various methods. No significant difference was found in penetration ratio between etched surface with 15% hydrochloric acid and 35% phosphoric acid. However, the penetration ratio was significantly higher in groups pretreated either with dental pumice or abrasive metal strip (p < .05). By the result of this study, etching with phosphoric acid as an alternative of hydrochloric acid was thought clinically acceptable as a pretreatment method for resin infiltration in early caries lesions for primary anterior teeth. It was notable that surface conditioning with dental pumice or metal strip before etching was effective in increasing the penetration. This procedural modification might be much more correspondent with minimally invasive concept and hopefully contribute to increased safety and utility in pediatric dentistry.

Fabrication of Microwire Arrays for Enhanced Light Trapping Efficiency Using Deep Reactive Ion Etching

  • Hwang, In-Chan;Seo, Gwan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.454-454
    • /
    • 2014
  • Silicon microwire array is one of the promising platforms as a means for developing highly efficient solar cells thanks to the enhanced light trapping efficiency. Among the various fabrication methods of microstructures, deep reactive ion etching (DRIE) process has been extensively used in fabrication of high aspect ratio microwire arrays. In this presentation, we show precisely controlled Si microwire arrays by tuning the DRIE process conditions. A periodic microdisk arrays were patterned on 4-inch Si wafer (p-type, $1{\sim}10{\Omega}cm$) using photolithography. After developing the pattern, 150-nm-thick Al was deposited and lifted-off to leave Al microdisk arrays on the starting Si wafer. Periodic Al microdisk arrays (diameter of $2{\mu}m$ and periodic distance of $2{\mu}m$) were used as an etch mask. A DRIE process (Tegal 200) is used for anisotropic deep silicon etching at room temperature. During the process, $SF_6$ and $C_4F_8$ gases were used for the etching and surface passivation, respectively. The length and shape of microwire arrays were controlled by etching time and $SF_6/C_4F_8$ ratio. By adjusting $SF_6/C_4F_8$ gas ratio, the shape of Si microwire can be controlled, resulting in the formation of tapered or vertical microwires. After DRIE process, the residual polymer and etching damage on the surface of the microwires were removed using piranha solution ($H_2SO_4:H_2O_2=4:1$) followed by thermal oxidation ($900^{\circ}C$, 40 min). The oxide layer formed through the thermal oxidation was etched by diluted hydrofluoric acid (1 wt% HF). The surface morphology of a Si microwire arrays was characterized by field-emission scanning electron microscopy (FE-SEM, Hitachi S-4800). Optical reflection measurements were performed over 300~1100 nm wavelengths using a UV-Vis/NIR spectrophotometer (Cary 5000, Agilent) in which a 60 mm integrating sphere (Labsphere) is equipped to account for total light (diffuse and specular) reflected from the samples. The total reflection by the microwire arrays sample was reduced from 20 % to 10 % of the incident light over the visible region when the length of the microwire was increased from $10{\mu}m$ to $30{\mu}m$.

  • PDF

A STUDY ON THE MICROSTRUCTURE OF IPS EMPRESS CERAMICS ACCORDING TO THE HEAT TREATMENT AND SPRUE TYPE (주입선 및 열처리에 따른 IPS Empress 도재의 미세구조에 관한 연구)

  • Dong, Jin-Keun;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.772-785
    • /
    • 1998
  • This study was undertaken to clarify the microstructure of the different IPS Empress ingots by etching and to observe the change of leucite crystal structure according to subsequent heat treatment and the crystal distribution according to sprue types(${\phi}2.8mm$, single sprue; ${\phi}1.8mm$, double sprue) by scanning electron microscopy. IPS Empress T1, O1 ingots used for staining technique, and Dentin(A2) ingots used for layering technique were selected for this study. To observe the microstructures of these ingots before pressing, the specimens were prepared in splinters($3{\times}3{\times}3mm$) taken from the original ingots. And to estimate crystal distribution and microstructural change by sprue type and subsequent heat treatment. the specimens($3{\times}3{\times}3mm$) were heat-pressed through the two types of sprues with different diameters and numbers, and all specimens were fired according to the recommended firing schedule. The observed surface was ground with waterproof papers($#800{\sim}#1800$) on the grind polisher and was cleaned ultrasonically. All specimen were etched with 0.5% hydrofluoric acid. After etching, the surface was treated by ion sputter coating for SEM observation at an accelerating voltage of 20kV. In all specimens, the central area of ground surface was observed because there was less difference in microstructure between the peripheral area and the central area. The results were as follows ; 1. In the microstructure according to the ingot type, there was a wide difference between the staining (T1,O1) and layering(Dentin A2) ingots, but there was not a considerable difference between the T1 ingot and the O1 ingot for staining technique. 2. In all specimens, the crystal dispersion of IPS Empress ceramic using double sprue was significantly more scattered than that of IPS Empress ceramic using single sprue. The degree of scattering was strongest in the Dentin(A2) specimen and weakest in the O1 ingot. 3. In the microstructural change according to the subsequent heat treatment, all of ingots had some microcracks in the inside of the leucite crystal and the glass matrix after pressing. The inner splinters of the leucite crystal became smaller, and more microcracks occurred in the glass matrix due to increasing heat treatment times. 4. The size of leucite crystals varied from $1{\mu}m\;to\;5{\mu}m$. The mean size of mature crystals was about $5{\mu}m$. The form of the crystal was similar to a circle when it was smaller and similar to an ellipse when it was larger.

  • PDF

Evaluation of at Rest Lateral Stress Coefficient Influenced by Particle Condition (입자의 조건에 따른 정지토압계수 평가)

  • Lee, Jung-Hwoon;Lee, Dong-Ryeol;Yun, Tae-Sup;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.8
    • /
    • pp.21-29
    • /
    • 2012
  • At-rest lateral stress coefficient that is used for the evaluation of geotechnical structures such as foundations and retaining walls plays a significant role in the analysis and design, as a state variable of in-situ stress condition. In the widely applied Jaky's Ko equation stress condition can be inferred from the internal friction angle obtainable from the laboratory experimentation whereas the eguation mares it challenging to evaluate the influences and criteria of particle characteristics which is essential for the application of friction angles in practices. Thus, this study experimentally explored the behaviors of Ko depending on the relative density, particle shape, and surface roughness effect during a range of loading stages. The Ko values of Jumumjin sand, glass beads, and etched glass beads were measured using a customized Ko device housing strain gauges during loading-unloading-reloading steps, and the effect of dominant factors on Ko is analyzed. Results show that the high Ko prevails for both round and angular specimens with low relative density and the surface roughness has a nominal effect. The angular particles exhibit low Ko for specimens with similar relative density. The characteristics of relevance between Ko and friction angles with varying relative density are also investigated based on the experimental results using empirical correlations and previously reported values.

THE STUDY OF FRACTURE STRENGTH OF PORCELAIN LAMINATE VENEER WITH VARIOUS LINGUAL EXTENTION LENGTH WHEN LNCISAL RESTORING (Porcelain Laminate veneer 절연 피복시 설측 연장 길이에 따른 파절강도의 연구)

  • Park, Johng-Han;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.746-754
    • /
    • 1996
  • The purpose of this study was to evaluate the fracture strength of porcelain laminate veneer with various lingual extention length when incisal restoring. Sixty recently extracted, intact maxillary incisors were used and stored in a physiologic saline solution from the time of extraction. Seating form was preparation at the labial surface of each tooth with a water-cooled round diamond bur. Standard block was formed with 32 gauge and 24 gauge wax at tooth labial and lingual surface. Lingual extention length differed according to each group. (group I : 0.5mm, group II : 1 mm, group III : 2mm, group IV : 0mm) All tooth specimens were impressioned with examix(GC Inc., Japan). Refractory cast were maked with refractory die material(Ceramco Inc., U.S.A.) Laminate porcelain (Ceramco II Veneer porcelain, Ceramco Inc., U.S.A.) was condensed in refractory die cast and baked according to the manufacturer's recommendations. Each surface was contoured with low speed diamond bur according to guide block. All porcelain specimens were sandblasted and ultrasonically cleaned in distlled water for 3 minutes. Then, all porcelain specimen were etched with 8% hydrofluoric acid for 5 minutes. Sixty specimens were bonded with composite resin cement(Choice Porcelain Veneer System, Bisco Inc., U.S.A.) according to manufacture's directions. The fracture loads of the specimen were measured by Instron universal testing machine. The mean values of fracture loads for the groups were statistically compared by Duncan's multiful range test. The result were as follows : Mean fracture strengths of each group were 86.95Mpa in no lingual extention group, 44.98Mpa in 0.5mm lingual extention group, 27.47Mpa in 1mm lingual extention group, 19.61Mpa in 2mm lingual extention group. There was a statistically significant difference between all group(p<0.01).

  • PDF