• Title/Summary/Keyword: error protection

Search Result 361, Processing Time 0.034 seconds

Optimizing the Circuit for Finding 2 Error Positions of 2 Error Correcting Reed Solomon Decoder (리드솔로몬 복호기에서 2개의 오류시, 오류위치를 찾는 최적화 방법)

  • An, Hyeong-Keon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.1C
    • /
    • pp.8-13
    • /
    • 2011
  • In this paper, we show new method to find error locations of 2 eight bit symbol errors for 2 error correcting Reed-Solomon decoder. New design is much faster and has much simpler logic circuit than the former design method. This optimization was possible by partitioning the 8 bit operations into 4 bit arithgmatic and logic operations. This Reed Solomon decoder can be used for data protection of almost all digital communication and consumer electronic devices.

The relationship between human factor and error for behavior of manufacturing industry employee (제조업근로자의 행동에 대한 인적요인 및 오류관계 연구)

  • Yoon, Yong-Gu
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.107-119
    • /
    • 2007
  • The purpose of this article is to examine the relationship between unsafe behavior, human factor and human error. For the object, several correlation analyses for those three elements were implemented. Several hypotheses for the relationship between them was suggested. The suggested hypotheses were verified by a comprehensive survey received from 132 safety manager of manufacturing industry. The conclusions were proven from the hypotheses verificaiton as belows; 1) The dependent relation items between unsafe behavior and human factor are dress protection tool, machine(equipment) and working rule have a dependent relation. 2) The dependent relation items between human factor and human error are uncommunication, control, slaps, fatigue, education, system, unmonitoring, failure. 3) The dependent relation items between human error and unsfafe behavior are decline and product/working method,failure and uncommunication have a dependent relation.

  • PDF

Examination with Transmission Line Distance Relay Setting Rule Considering Error (오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰)

  • Cho, Seong-Jin;Choi, Myeong-Song;Hyun, Seung-Ho;Kim, Joung-Wook;Lee, Joo-Wang;Cho, Bum-Sub;Yoo, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

AN IV CATHETER FRAGMENTS DURING MDCT SCANNING OF HUMAN ERROR: EXPERIMENTAL AND REPRODUCIBLE MICROSCOPIC MAGNIFICATION ANALYSIS

  • Kweon, Dae-Cheol;Lee, Jong-Woong;Choi, Ji-Won;Yang, Sung-Hwan;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.195-199
    • /
    • 2011
  • The use of intravenous catheters are occasionally complicated by intravascular fragments and swelling of the catheter fragments. We present a patient in whom an intravenous catheter fragments was retrieved from the dorsal metacarpal vein following its incidental CT examination detection. The case of demonstrates the utility of microscopy and multi-detector CT in localizing small of subtle intravenous catheter fragments as a human error. A case of IV catheter fragments in the metacarpal vein, in which reproducible and microscopy data allowed complete localization of a missing fragments and guided surgery with respect to the optimal incision site for fragments removal. These reproducible studies may help to determine the best course of action and treatment for the patient who presents with such a case.

Availability Analysis of SRAM-Based FPGAs under the protection of SEM Controller (SEM Controller에 의해 보호되는 SRAM 기반 FPGA의 가용성 분석)

  • Ryu, Sang-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.601-606
    • /
    • 2017
  • SRAM-based FPGAs mainly used to develop and implement high-performance circuits have SRAM-type configuration memory. Soft errors in memory devices are the main threat from a reliability point of view. Soft errors occurring in the configuration memory of FPGAs cause FPGAs to malfunction. SEM(Soft Error Mitigation) Controllers offered by Xilinx can mitigate the influence of soft errors in configuration memory. SEM Controllers use ECC(Error Correction Code) and CRC(Cyclic Redundancy Code) which are placed around the configuration memory to detect and correct the errors. The correction is done through a partial reconfiguration process. This paper presents the availability analysis of SRAM-based FPGAs against soft errors under the protection of SEM Controllers. Availability functions were derived and compared according to the correction capability of SEM Controllers of several different families of FPGAs. The result may help select an SRAM-based FPGA part and estimate the availability of FPGAs running in an environment where soft errors occur.

Performances of wireless ATM cell transmission with partial concatenated coding (무선 ATM셀 전송을 위한 부분 연쇄 부호화 기법의 성능분석)

  • 이진호;김태중;이동도;안재영;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.9
    • /
    • pp.2014-2026
    • /
    • 1997
  • In this paper, the performances of wireless asynchronous transfer mode (ATM) cell transmission in mobile work are analyzed. We adopt 16Star QAM as amodulation technique in wireless channel and considered Reed-Solomon, convolutional, and concatenated coding to improve the error rate performances, and also proposed the Partial Concatenated Coding (PCC) technique as UEP(unequal error protection) code for efficient transmission of ATM cell in the air interface. We consider Doppler's effect, Rician fading, and diversity technique of maximal-ratio combining (MRC) for mobile channel model. For performance measure, we analyze bit error rate, ATM cell loss probability, ATM cell error probability, and network performances of ATM cell transmission delay and throughput. The numerical results show that the adoption of PCC is a prospective way for the evolution of future wireless ATM network on mobile environment.

  • PDF

Mid-Term Performance of Clinical LINAC in Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.43-52
    • /
    • 2019
  • Background: The mid-term performance of clinical linear accelerator (LINAC) during volumetric modulated arc therapy (VMAT) treatment period is not performed in clinical practice and usually replaced with one-time plan quality assurance (QA). In this research we aim to monitor daily reproducibility of VMAT delivery from tracking individual leaf movement error and dosimetric error to evaluate the mid-term quality of the machine used. Materials and Methods: First, multileaf collimator (MLC) information was imported into MATLAB program to determine which of the MLC leaves in the leaf bank had the maximum RMS position error (maxRMS). We estimated where the maximum positional errors (maxPE) of the chosen leaf occur along its path length and tracked its daily variations over the entire treatment period. Secondly, picture information of dosimetric error from portal dosimetry was imported into MATLAB where representative high gamma index region (HGR) was determined as HGR with length of > 1 cm and their centers were daily tracked. Results and Discussion: The maxPEs in the brain and tongue cases were distributed broader than in other cases, but all data were found located within ${\pm}0.5mm$. From first day to last day all of five cases show the similar visual pattern of HGRs and Centers of the longest HGRs remained within ${\pm}1mm$ of that in first day. These findings prove excellent mid-term performance of the LINAC used in VMAT treatments over a full course of treatment. Conclusion: Tracking the daily location changes of leaf movement and dosimetric error can be a good indicator of predicting the daily quality like stability and reproducibility of beam delivering in VMAT treatment.

Numerical Algorithm for Distance Protection and Arcing Fault Recognitior (고장거리계산과 아크고장 판별 알고리즘)

  • Radojevic, Zoran;Park, K.W.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.163-165
    • /
    • 2002
  • In this paper a new numerical algorithm for fault distance calculation and arcing fault recognition based on one terminal data and derived in lime domain is presented. The algorithm is derived for the case of most frequent single-phase line to ground fault. The faulted phase voltage at the fault place is modeled as a serial connection of fault resistance and arc voltage. The fault distance and arc voltage amplitude are estimated using Least Error Squares Technique. The algorithm can be applied for distance protection, intelligent autoreclosure and for fault location. The results of algorithm tested through computer simulation are given.

  • PDF

DEVELOPMENT OF POINT KERNEL SHIELDING ANALYSIS COMPUTER PROGRAM IMPLEMENTING RECENT NUCLEAR DATA AND GRAPHIC USER INTERFACES

  • Kang, Sang-Ho;Lee, Seung-Gi;Chung, Chan-Young;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.215-224
    • /
    • 2001
  • In order to comply with revised national regulationson radiological protection and to implement recent nuclear data and dose conversion factors, KOPEC developed a new point kernel gamma and beta ray shielding analysis computer program. This new code, named VisualShield, adopted mass attenuation coefficient and buildup factors from recent ANSI/ANS standards and flux-to-dose conversion factors from the International Commission on Radiological Protection (ICRP) Publication 74 for estimation of effective/equivalent dose recommended in ICRP 60. VisualShieid utilizes graphical user interfaces and 3-D visualization of the geometric configuration for preparing input data sets and analyzing results, which leads users to error free processing with visual effects. Code validation and data analysis were performed by comparing the results of various calculations to the data outputs of previous programs such as MCNP 4B, ISOSHLD-II, QAD-CGGP, etc.

  • PDF

Motor Protection and Control with Digital Protective Relays (디지털 보호 계전기를 이용한 모터 보호 및 제어)

  • 이성환;안인석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.178-178
    • /
    • 2000
  • In this paper, intelligent methods using digital protection relay in power management and control system is developed in order to protect power systems by means of timely fault detection during operation and control at starting for induction motor which have various load environments and capacities in power systems. The digital protective relay was designed with DSP CPU(TMS320C31) to Protect and measure more quickly and precisely. The test result on the basis of KEMCl120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within $\pm$5%. Also, we can control motors at starting according to starting types with simple method as programmable sequence editor. So we can improve the demerits of high cost and much manhour for rework.

  • PDF