• 제목/요약/키워드: equivalent viscous damping ratio

검색결과 41건 처리시간 0.018초

Vibration control parameters investigation of the Mega-Sub Controlled Structure System (MSCSS)

  • Limazie, Toi;Zhang, Xun'an;Wang, Xianjie
    • Earthquakes and Structures
    • /
    • 제5권2호
    • /
    • pp.225-237
    • /
    • 2013
  • Excessive vibrations induced by earthquake excitation and wind load are an obstacle in design and construction of tall and super tall buildings. An innovative vibration control structure system (Mega-Sub Controlled Structure System-MSCSS) was recently proposed to further improve humans comfort and their safeties during natural disasters. Preliminary investigations were performed using a two dimensional equivalent simplified model, composed by 3 mega-stories. In this paper, a more reasonable and realistic scaled model is design to investigate the dynamical characteristics and controlling performances of this structure when subjected to strong earthquake motion. The control parameters of the structure system, such as the modulated sub-structures disposition; the damping coefficient ratio (RC); the stiffness ratio (RD); the mass ratio of the mega-structure and sub-structure (RM) are investigated and their optimal values (matched values) are obtained. The MSCSS is also compared with the so-called Mega-Sub Structure (MSS) regarding their displacement and acceleration responses when subjected to the same load conditions. Through the nonlinear time history analysis, the effectiveness and the feasibility of the proposed mega-sub controlled structure system (MSCSS) is demonstrated in reducing the displacement and acceleration responses and also improving human comfort under earthquake loads.

Cyclic testing of chevron braced steel frames with IPE shear panels

  • Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • 제19권5호
    • /
    • pp.1167-1184
    • /
    • 2015
  • Despite considerable life casualty and financial loss resulting from past earthquakes, many existing steel buildings are still seismically vulnerable as they have no lateral resistance or at least need some sort of retrofitting. Passive control methods with decreasing seismic demand and increasing ductility reduce rate of vulnerability of structures against earthquakes. One of the most effective and practical passive control methods is to use a shear panel system working as a ductile fuse in the structure. The shear Panel System, SPS, is located vertically between apex of two chevron braces and the flange of the floor beam. Seismic energy is highly dissipated through shear yielding of shear panel web while other elements of the structure remain almost elastic. In this paper, lateral behavior and related benefits of this system with narrow-flange link beams is experimentally investigated in chevron braced simple steel frames. For this purpose, five specimens with IPE (narrow-flange I section) shear panels were examined. All of the specimens showed high ductility and dissipated almost all input energy imposed to the structure. For example, maximum SPS shear distortion of 0.128-0.156 rad, overall ductility of 5.3-7.2, response modification factor of 7.1-11.2, and finally maximum equivalent viscous damping ratio of 35.5-40.2% in the last loading cycle corresponding to an average damping ratio of 26.7-30.6% were obtained. It was also shown that the beam, columns and braces remained elastic as expected. Considering this fact, by just changing the probably damaged shear panel pieces after earthquake, the structure can still be continuously used as another benefit of this proposed retrofitting system without the need to change the floor beam.

Hysteretic behaviors of pile foundation for railway bridges in loess

  • Chen, Xingchong;Zhang, Xiyin;Zhang, Yongliang;Ding, Mingbo;Wang, Yi
    • Geomechanics and Engineering
    • /
    • 제20권4호
    • /
    • pp.323-331
    • /
    • 2020
  • Pile foundation is widely used for railway bridges in loess throughout northwestern China. Modeling of the loess-pile interaction is an essential part for seismic analysis of bridge with pile foundation at seismically active regions. A quasi-static test is carried out to investigate the hysteretic behaviors of pile foundation in collapsible loess. The failure characteristics of the bridge pile-loess system under the cyclic lateral loading are summarized. From the test results, the energy dissipation, stiffness degradation and ductility of the pile foundation in loess are analyzed. Therefore, a bilinear model with stiffness degradation is recommended for the nonlinearity of the bridge pier-pile-loess system. It can be found that the stiffness of the bridge pier-pile-loess system decreases quickly in the initial stage, and then becomes more slowly with the increase of the displacement ductility. The equivalent viscous damping ratio is defined as the ratio of the dissipated energy in one cycle of hysteresis curves and increases with the lateral displacement.

Experimental study on seismic performance of steel reinforced concrete T-shaped columns

  • Liu, Zuqiang;Zhou, Chaofeng;Xue, Jianyang;Leon, Roberto T.
    • Steel and Composite Structures
    • /
    • 제36권3호
    • /
    • pp.339-353
    • /
    • 2020
  • This study investigates the seismic performance of steel reinforced concrete (SRC) T-shaped columns under low cyclic loading tests. Based on test results of ten half-scale column specimens, failure patterns, hysteretic behavior, skeleton curves, ultimate strength, ductility, stiffness degradation and energy dissipation capacity were analyzed. The main variables included loading angles, axial compression ratios and steel ratios. The test results show that the average values of the ductility factor and the equivalent viscous damping coefficient with respect to the failure of the columns were 5.23 and 0.373, respectively, reflecting good seismic performance. The ductility decreased and the initial stiffness increased as the axial compression ratio of the columns increased. The strength increased with increasing steel ratio, as expected. The columns displaced along the web had higher strength and initial stiffness, while the columns displaced along the flange had better ductility and energy dissipation capacity. Based on the test and analysis results, a formula is proposed to calculate the effective stiffness of SRC T-shaped columns.

Minimization of Modeling Error of the Linear Motion System with Voice Coil Actuator

  • Hwang, Jin-Dong;Kwak, Yong-Kil;Jung, Hong-Jung;Kim, Sun-Ho;Ahn, Jung-Hwan
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권1호
    • /
    • pp.54-61
    • /
    • 2008
  • This paper presents a method for reducing modelling error in the linear motion system with voicecoil actuator (VCA). A model of linear motion system composed of a mechanism and control was prepared to verify the proposed method. In modeling of the system, the damping coefficient obtained experimentally is applied to the model in order to consider the effect of the viscous friction for the moving part in VCA. The response velocity of VCA for duty ratio of PWM signal was analyzed in the time domain. Consequently, the relation between velocity and duty ratio was obtained. The result from the experiment showed an error of 9% when compared with that of simulation. In order to reduce the modeling error, impedance variation according to input frequency was analyzed, and equivalent impedance with multi-frequency was applied to the control part. As a result, the modeling error decreased to 5%.

Numerical and analytical investigation of cyclic behavior of D-Shape yielding damper

  • Kambiz Cheraghi;Mehrzad TahamouliRoudsari;Sasan Kiasat;Kaveh Cheraghi
    • Structural Engineering and Mechanics
    • /
    • 제89권4호
    • /
    • pp.411-420
    • /
    • 2024
  • The purpose of this research was to investigate the cyclic behavior of the D-shaped dampers (DSD). Similarly, at first, the numerical model was calibrated using the experimental sample. Then, parametric studies were conducted in order to investigate the effect of the radius and thickness of the damper on energy dissipation, effective and elastic stiffness, ultimate strength, and equivalent viscous damping ratio (EVDR). An analytical equation for the elastic stiffness of the DSD was also proposed, which showed good agreement with experimental results. Additionally, approximate equations were introduced to calculate the elastic and effective stiffness, ultimate strength, and energy dissipation. These equations were presented according to the curve fitting technique and based on numerical results. The results indicated that reducing the radius and increasing the thickness led to increased energy dissipation, effective stiffness, and ultimate strength of the damper. On the other hand, increasing the radius and thickness resulted in an increase in EVDR. Moreover, the ratio of effective stiffness to elastic stiffness also played a crucial role in increasing the EVDR. The thickness and radius of the damper were evaluated as the most effective dimensions for reducing energy dissipation and EVDR.

나선철근으로 횡구속된 정사각형 RC 기둥의 내진성능 (Seismic Performance of Square RC Column Confined with Spirals)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권5호
    • /
    • pp.88-97
    • /
    • 2012
  • 본 연구에서는 비내진 교각의 내진성능과 휨-전단 거동을 파악하고자 형상비 4.5인 정사각형의 중실 및 중공단면 철근콘크리트 교각실험체를 제작하여 일정한 축력하에서 변위비 등급을 증가시켜 가면서 횡하중을 가력하는 실험을 수행하였다. 본 연구는 철근콘크리트 교각의 한정연성 내진설계를 위한 실험적 기초자료의 제공과 함께 성능단계별 교각성능 및 손상평가를 위한 정량적 수치와 경향을 제공하기 위한 것이며, 파괴거동, 극한변위, 극한드리프트비율, 변위연성도, 응답수정계수, 등가점성감쇠비, 잔류변형지수, 유효강성, 철근 변형률 등의 주요 내진성능 인자들에 대한 분석결과와 비선형 해석 결과를 나타내었다.

파형강관 내부 구속 중공 철근 콘크리트 기둥의 내진 성능 (Seismic Performance of Internally Confined Hollow RC Column with Corrugated Steel Tube)

  • 한택희;김종민;강준석;강영종
    • 한국방재학회 논문집
    • /
    • 제8권2호
    • /
    • pp.31-38
    • /
    • 2008
  • 파형강관으로 내부 구속된 중공 철근콘크리트 기둥(파형강관 내부 구속 중공 RC 기둥, ICH RC-CT column ; Internally Confined Hollow RC column with a Corrugated Steel Tube)의 내진 성능 평가 실험을 수행하였다. 준정적 실험을 통하여 ICH RC-CT 기둥과 일반 중실 RC 기둥의 내진 성능을 비교 평가 하였다. 각각의 기둥 시험체에 대해 하중과 변위의 관계를 측정하였으며, 이를 바탕으로 연성도, 소산에너지, 등가 감쇠비, 손상 지수가 계산되었다. 실험 결과 ICH RC-CT 기둥은 중실 RC 기둥에 비해 작은 에너지 소산능력을 보여주었으나, 에너지 연성도와 등가 점성 감쇠비 측면에서는 거의 대등한 성능을 보여주었다.

장방형 띠철근을 이용한 팔각형 플레어 RC 기둥의 내진성능 (Seismic Performance of Octagonal Flared RC Columns using Oblong Hoops)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.1-9
    • /
    • 2015
  • 횡방향철근은 기둥의 소성힌지구간에 충분한 구속효과, 축방향철근의 좌굴방지와 연성거동을 확보하기 위해 적용된다. 기둥에서 사각형 후프 띠철근과 보강 띠철근의 조립 및 배근방법은 시공이 까다롭고 많은 횡방향철근량이 요구된다. 본 논문에서, 이러한 문제점들을 해결하기 위하여 장방형 단면과 플레어 기둥의 횡구속을 위한 장방형 후프 띠철근을 사용한 새로운 횡구속 방법이 제안되었다. 개발된 장방형 후프 띠철근 상세는 장방형 단면과 플레어 기둥의 시공성과 경제성을 향상시켜줄 수 있는 하나의 대안으로서 적용 가능한 것으로 판단된다. 본 연구의 최종목적은 철근콘크리트 교각의 시공성 향상을 위한 장방형 후프 띠철근 상세의 제시와 실험적 기초자료의 제공과 함께 하중단계별 성능 및 손상평가를 위한 정량적 수치와 경향을 제공하기 위한 것이며, 극한변위, 극한드리프트비율, 변위연성도, 응답수정계수, 등가점성감쇠비, 잔류변형지수, 유효강성 등의 주요 내진성능평가 변수들에 대한 분석결과를 나타내었다.

Investigations of different steel layouts on the seismic behavior of transition steel-concrete composite connections

  • Qi, Liangjie;Xue, Jianyang;Zhai, Lei
    • Advances in concrete construction
    • /
    • 제8권3호
    • /
    • pp.173-185
    • /
    • 2019
  • This article presents a comparative study of the effect of steel layouts on the seismic behavior of transition steel-concrete composite connections, both experimental and analytical investigations of concrete filled steel tube-reinforced concrete (CFST-RC) and steel reinforecd concrete-reinforced concrete (SRC-RC) structures were conducted. The steel-concrete composite connections were subjected to combined constant axial load and lateral cyclic displacements. Tests were carried out on four full-scale connections extracted from a real project engineering with different levels of axial force. The effect of steel layouts on the mechanical behavior of the transition connections was evaluated by failure modes, hysteretic behavior, backbone curves, displacement ductility, energy dissipation capacity and stiffness degradation. Test results showed that different steel layouts led to significantly different failure modes. For CFST-RC transition specimens, the circular cracks of the concrete at the RC column base was followed by steel yielding at the bottom of the CFST column. While uncoordinated deformation could be observed between SRC and RC columns in SRC-RC transition specimens, the crushing and peeling damage of unconfined concrete at the SRC column base was more serious. The existences of I-shape steel and steel tube avoided the pinching phenomenon on the hysteresis curve, which was different from the hysteresis curve of the general reinforced concrete column. The hysteresis loops were spindle-shaped, indicating excellent seismic performance for these transition composite connections. The average values of equivalent viscous damping coefficients of the four specimens are 0.123, 0.186 and 0.304 corresponding to the yielding point, peak point and ultimate point, respectively. Those values demonstrate that the transition steel-concrete composite connections have great energy dissipating capacity. Based on the experimental research, a high-fidelity ABAQUS model was established to further study the influence of concrete strength, steel grade and longitudinal reinforcement ratio on the mechanical behavior of transition composite connections.