• Title/Summary/Keyword: equivalent test

Search Result 1,960, Processing Time 0.029 seconds

Analysis on the Running Stability of Rolling-stock according to Wheel Profile Wear (차륜답면형상 마모에 따른 차량 주행안정성 영향 분석)

  • Hur, Hyun-Moo;You, Won-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.5
    • /
    • pp.551-558
    • /
    • 2011
  • To analyze the effect of wear of wheel profile on the running stability of rolling-stock, theoretical and experimental studies were conducted on the profiles used in conventional lines. In experiment using 1/5 scale model to verify the results of the theoretical analysis, the test results of the critical speed for worn wheel profile samples show similar trend. In case of the conical type wheel profile(Profile 40), the equivalent conicity is increased with flange wear. But in case of the arc type wheel profile(Profile 20h), the equivalent conicity is decreased with flange wear. And the critical speed of the bogie was inverse proportion to the equivalent conicity. It is shown that the variation of the critical speed with the wheel wear could be changed according to the design concept and wear pattern of wheel profile. Results of the theoretical and experimental studies are discussed here.

Tie Line Constrained Equivalent Assisting Generator Model (TEAG) Considering Forced Outage Rates of Transmission Systems

  • Park, Jaeseok;Tran, Trung-Tinh;Sungrok Kang;Park, Dongwook;Jaeyoung Yoon;Seungil Moon;Roy Billinton
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.2
    • /
    • pp.91-99
    • /
    • 2004
  • This paper illustrates a tie line constrained equivalent assisting generator (TEA G) model considering forced outage rates of transmission systems for reliability evaluation of interconnected power systems. Interconnections between power systems can provide improved levels of reliability. It is expected that the TEAG model developed in this paper will prove useful in the solution to problems related to the effect of transmission system uncertainties in the reliability evaluation of interconnected power systems. The characteristics and concept of this TEAG considering transmission systems are described in detail by sample studies on a simple test system.

A Reduced Equivalent Line Constant of the Catenary System (전차선로 시스템의 축약 등가 선로정수에 관한 연구)

  • 이한민;오광해;이장무;박현준;장길수;권세혁
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.8
    • /
    • pp.421-431
    • /
    • 2004
  • Line constants are composed by impedances and susceptances. A paper which was published estimated only impedances of line constants. Therefore, this paper estimates susceptances as well as impedances of equivalent five-conductors model using the reduced equivalent method. In order to verify estimated line constants, we measured line constants of real railway system. And we compared calculated results with measured data on 60Hz∼3000Hz. For the other verification, the calculation results from the proposed model and the measurement data from the test are compared focused on the amplification of harmonic current in the paper.

A study on the estimation of an equivalent system of a local vibration system of a huge structure and the Optimum Structural Modification Method (거대 구조물의 국부진동계의 등가계 산출과 이를 이용한 최적구조변경법)

  • 황문주;박석주;이기문
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.364-369
    • /
    • 1997
  • It is very difficult to execute the vibration analysis of a huge structure, which takes up much time and expense. In this paper we intend to make the equivalent system of a local vibration system of a huge structure with a view to improving the dynamic characteristics and reducing time and expense. First of all, upper deck structure model is maded. And we perform the vibration analysis by the Substructure Synthesis Method and execute the exciting test for the upper deck structure model, and observe the coincidences of two results to confirm the reliability of the analyzing tools used. To make the equivalent system, we give boundary condition to sub-structure that want to be modified and execute the Sensitivity Analysis Method and the Optimum Structural Modification Method. And we execute the structural modification of the equivalent system.

  • PDF

Antimutagenic Effects of Persimmon Leaf Tea Extract (PLTE) in Mice Using Micronucleus Induction (MN) Test (마우스 소핵(Micronuclei, MN) 시험방법을 이용한 감잎차 추출물의 돌연변이 억제효과)

  • 송현순;이현걸;강명희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.5
    • /
    • pp.881-887
    • /
    • 2000
  • The antimutagenic effects of persimmon leaf tea extract (PLTE) at concentration levels consumed by human were examined in mice using micronuleus induction with MMC(mitomycin C) or 4-NQO (4-nitroquinoline-1-oxide). When mice received oral gavage of 10 equivalent to PLTE 24 hr and 6 hr before, and 5 equivalent to PLTE 6 hr before and 3 hr after intraperitoneal injection of MMC, a significant decrease in the frequency of micronuclei were observed. The induction of micronuclei by 4-NQO was suppressed by oral dosage of PLTE at 5 equivalent to PLTE 6 hr before and 3 hr after, 10 equivalent to PLTE 3 hr before and 3 hr after intraperitoneal injection of MMC. Though the components of PLTE have not been analyzed so far, our present results suggest the existence of several bio-antimutagens and/or desmutagens in PLTE, beside catechin, well-known antimutagen.

  • PDF

A generalized Hollander-Proschan test for NBUE alternative based on U-statistics approach

  • Hassan, M.KH.
    • International Journal of Reliability and Applications
    • /
    • v.16 no.2
    • /
    • pp.113-122
    • /
    • 2015
  • In this paper, we introduce U-statistics approach to generalized Hollander-Proschan test for new better than used (NBUE) alternative. We prove, the proposed test is equivalent to test was introduced by Anis and Mitra (2011) and includes test was introduced by Hollander Proschan (1975). Also, the asymptotic properties are studied. The powers of our test are estimated. The Pitman asymptotic efficiencies of proposed test are also calculated. Finally, the test is applied to some real data.

An Investigation of Dissipation Analysis for Dilatometer & New Interpretation Method (딜라토메터 소산시험 해석에 대한 고찰 및 새로운 해석법)

  • 김영상
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.365-368
    • /
    • 2003
  • Despite of the simple equipment and operation, DMT has been widely used to obtain various soil parameters and those parameters have been successfully applied to geotechnical design practice. Among them, the estimation of horizontal coefficient of consolidation is so useful that many researchs recently have been carried out. However, simulation of the penetration of the DMT blade is complex due to the inherent difficulty on analyzing a plane strain deformation of the soil around blade. Therefore, empirical and semi-empirical methods that use the theoretical solution developed fur piezocone with some assumptions have been used to estimate the coefficient of consolidation from Dilatometer dissipation test. In this paper, coefficients of consolidation c$\_$h/ which were obtained using equivalent radius that is same area with the DMT blade and optimization technique are compared with those obtained from Oedometer test and other interpretation methods. It was found that a new method used in this study can give more precise horizontal coefficient of consolidation than other methods do.

  • PDF

Chloride-Penetration Analysis in Cracked Early-Age Concrete (균열을 갖는 초기재령 콘크리트의 염화물 침투 해석)

  • 송하원;박상순;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.635-640
    • /
    • 2001
  • In this study, a mathematical model is established for prediction of chloride penetration in unsaturated cracked early-age concrete. The model is combined with models for thermo-hygro dynamic coupling of cement hydration, moisture transport and micro-structure development. Chloride permeability and water permeability at cracked early-age concrete specimens are evaluated using a rapid chloride permeability test and a low-pressure water permeability test, respectively. Then, a homogenization technique is introduced into the model to determine equivalent diffusion coefficient and equivalent Permeation coefficient. Increased chloride transport due to cracks at the specimen could be predicted fairly well by characterizing the cracks using proposed model. Proposed model is verified by comparing diffusion analysis results with test results.

  • PDF

A Study on the Exhaust System Model for Thermal Stress Analysis of Exhaust Manifold (배기매니폴드의 열응력 해석을 위한 배기계 모델 구성에 관한 연구)

  • Choi, Bok-Lok;Lee, Kyung-Woo;Chang, Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.7-13
    • /
    • 2010
  • In this study, we investigated the efficient FE modelling techniques for thermal stress analysis of the exhaust manifold subject to thermo-mechanical cyclic loadings. At first, full engine model was considered to identify the critical locations and their results were compared to failure site shown by the engine bench test. And the equivalent system model was proposed based on the mechanical behavior of the full engine model. The weak areas of both FE models show a good agreement with the experimental crack location. As a result, a simplified modelling methodology was verified to estimate the thermo-mechanical behaviors of the exhaust manifold under thermal shock test condition.

Dynamic Characteristics Analysis of Linear Induction Motor (유도형 리니어모터의 동특성 해석)

  • Jang, S.M.;Chang, K.W.;Lee, S.H.;Jung, S.S.;Park, Y.T.;Kim, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.626-628
    • /
    • 2000
  • This paper treats the dynamic analysis and test results of Linear Induction Motor. The dynamic analysis is performed by the d,q axis equivalent-circuit model. Equivalent-circut parameters are obtained with no-load, lock test and field analysis. As a results, simulation results are compared with that of dynamic test.

  • PDF