• Title/Summary/Keyword: equivalent static load method

검색결과 93건 처리시간 0.021초

단순 해석 모델을 이용한 밸브지지대 내진 성능 평가 (Seismic Performance Evaluation of Valve Support using Simplified FE Model)

  • 김상영;금동엽;김형은;김대진;김준호;홍성경;최원목;석창성
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.60-65
    • /
    • 2017
  • In this study, a simplified FE model for evaluating seismic performance of valve support was suggested and an apparatus for a real structure testing was developed. The seismic performances of three different types of valve supports were evaluated by the real structure testing. By comparing the results between the real structure testing and FEA using the simplified FE model, it was verified that the suggested simplified FE model can be utilized for comparative evaluation of seismic performance of valve supports.

Study on wind-induced vibration response of Jiayuguan wooden building

  • Teng Y. Xue;Hong B. Liu;Ting Zhou;Xin C. Chen;Xiang Zhang;Zhi P. Zou
    • Wind and Structures
    • /
    • 제37권3호
    • /
    • pp.245-254
    • /
    • 2023
  • In this paper, the wind-induced response of Jiayuguan wooden building (world cultural heritage) in Northwest China was studied. ANSYS finite element software was used to establish four kinds of building models under different working conditions and carry out modal analysis. The simulation results were compared with the field dynamic test results, obtaining the model which reflects the real vibration characteristics of the wooden tower. Time history data of fluctuating wind speed was obtained by MATLAB programming. Time domain method and ANSYS were used to analyze the wind-induced vibration response time history of Jiayuguan wooden building, obtaining the displacement time history curve of the structure. It was suggested that the wind-induced vibration coefficient of Jiayuguan wooden building is 1.76. Through analysis of the performance of the building under equivalent static wind load, the maximum displacement occurs in the three-story wall, gold column and the whole roof area, and the maximum displacement of the building is 5.39 cm. The ratio of the maximum stress value to the allowable value of wood tensile strength is 45 %. The research results can provide reference for the wind resistant design and protection of ancient buildings with similar structure to Jiayuguan wooden tower.

SPR 접합법을 이용한 Al-5052 인장-전단 시험편의 피로강도 (Fatigue Strength of Al-5052 Tensile-Shear Specimens using a SPR Joining Method)

  • 이만석;김택영;강세형;김호경
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.9-14
    • /
    • 2014
  • Self-piercing riveting(SPR) is a mechanical fastening technique which is put pressure on the rivet for joining the sheets. Unlike a spot welding, SPR joining does not make the harmful gas and $CO_2$ and needs less energy consumption. In this study, static and fatigue tests were conducted using tensile-shear specimens with Al-5052 plates for evaluation of fatigue strength of the SPR joints. During SPR joining process for the specimen, using the current sheet thickness and a rivet, the optimal applied punching force was found to be 21 kN. And, the maximum static strength of the specimen produced at the optimal punching force was 3430 N. During the fatigue tests for the specimens, interface failure mode occurred on the top substrate close to the rivet head in the most high-loading range region, but on the bottom substrate close to the rivet tail in the low -loading range region. There was a relationship between applied load amplitude $P_{amp}$ and lifetime of cycle N for the tensile-shear, $P_{amp}=3395.5{\times}N^{-0.078}$. Using the stress-strain curve of the Al-5052 from tensile test, the simulations for fatigue specimens have been carried out using the implicit finite element code ABAQUS. The relation between von-Mises equivalent stress amplitude and number of cycles was found to be ${\sigma}_{eq}=514.7{\times}N^{-0.033}$.

전산플랫폼을 이용한 초고층구조물의 감쇠장치 최적화 설계 (Optimization Design of Damping Devices for a Super-Tall Building Using Computational Platform)

  • 정보라;이상현;정란;최현철
    • 한국전산구조공학회논문집
    • /
    • 제28권2호
    • /
    • pp.145-152
    • /
    • 2015
  • 본 연구에서는 파라매트릭 모델링 기법을 통해 다양한 대안을 고려할 수 있도록 개발된 StrAuto(이하 전산플랫폼)을 이용하여 감쇠장치에 따른 감쇠비 증가 효과와 풍하중 저감효과를 평가하였다. 비정형 초고층구조물의 수많은 구조시스템 대안 선정을 지원하는 전산플랫폼은 설계자 또는 엔지니어에게 초기 대안을 결정하는데 있어 유용한 도구가 된다. 감쇠장치의 용량 및 추가 요구감쇠비의 크기를 산정하는 과정에서 중요한 원 구조물의 감쇠비에 대한 추정은 풍하중에 대한 실계측 자료를 기반으로 수행된 국내외 관련 연구의 결과를 사용하였다. 감쇠장치는 층간 설치형 수동형 감쇠장치와 질량형 능동형 감쇠장치 두 가지 유형을 고려하였다. 감쇠장치에 의해 추가되는 감쇠비는 FEMA에서 제안한 식을 이용하여 등가 정적 해석을 수행하여 산정하였다. 전산 플랫폼 내부에 감쇠장치의 용량을 최적화하는 알고리즘을 내장함으로써 최적의 감쇠장치 설계안을 자동적으로 도출할 수 있다. 감쇠장치 설치에 따른 물량저감 효과는 풍하중 저감계수로 평가될 수 있으며, 455m 높이의 초고층구조물을 대상으로 제안한 방법의 유효성을 검증하였다. 제안한 방법을 사용하여 비선형 시간이력 해석을 통해 얻어진 지붕층 변위와 층별 전단력을 근사적으로 추정할 수 있음을 확인하였다.

Continuous force excited bridge dynamic test and structural flexibility identification theory

  • Zhou, Liming;Zhang, Jian
    • Structural Engineering and Mechanics
    • /
    • 제71권4호
    • /
    • pp.391-405
    • /
    • 2019
  • Compared to the ambient vibration test mainly identifying the structural modal parameters, such as frequency, damping and mode shapes, the impact testing, which benefits from measuring both impacting forces and structural responses, has the merit to identify not only the structural modal parameters but also more detailed structural parameters, in particular flexibility. However, in traditional impact tests, an impacting hammer or artificial excitation device is employed, which restricts the efficiency of tests on various bridge structures. To resolve this problem, we propose a new method whereby a moving vehicle is taken as a continuous exciter and develop a corresponding flexibility identification theory, in which the continuous wheel forces induced by the moving vehicle is considered as structural input and the acceleration response of the bridge as the output, thus a structural flexibility matrix can be identified and then structural deflections of the bridge under arbitrary static loads can be predicted. The proposed method is more convenient, time-saving and cost-effective compared with traditional impact tests. However, because the proposed test produces a spatially continuous force while classical impact forces are spatially discrete, a new flexibility identification theory is required, and a novel structural identification method involving with equivalent load distribution, the enhanced Frequency Response Function (eFRFs) construction and modal scaling factor identification is proposed to make use of the continuous excitation force to identify the basic modal parameters as well as the structural flexibility. Laboratory and numerical examples are given, which validate the effectiveness of the proposed method. Furthermore, parametric analysis including road roughness, vehicle speed, vehicle weight, vehicle's stiffness and damping are conducted and the results obtained demonstrate that the developed method has strong robustness except that the relative error increases with the increase of measurement noise.

원자력 발전소용 버터플라이밸브의 내진해석 (Theoretical Seismic Analysis of Butterfly Valve for Nuclear Power Plant)

  • 한상욱;안준태;이경철;한승호
    • 대한기계학회논문집A
    • /
    • 제36권9호
    • /
    • pp.1009-1015
    • /
    • 2012
  • 밸브는 지진하중 하에서 구조안전성이 요구되는 원자력 발전소 파이프 라인 시스템에 설치되는 중요한 장비 중 하나이다. 밸브의 성능향상을 위한 형상최적설계에서 지진하중조건을 고려한 밸브의 구조안전성 검증이 반드시 필요하다. 최근, 이론적인 내진검증 기법과 절차가 체계화되어 있어 지진하중하에서 설계조건을 만족하는 대상체의 적절한 설계변수가 이론적으로 얻어지고 있다. 본 연구에서는 원자력 발전소용 200A 버터플라이밸브를 대상으로 KEPIC MFA 에서 제시하고 있는 이론적인 정적내진해석과 동적내진해석 절차를 통하여 내진검증을 수치해석기법과 실험을 병행하여 수행하였다. 자중, 운전조건 및 안전정지지진하중 조건을 모두 고려한 정적내진해석을 통해 밸브의 스템과 바디 접촉부에 작용하는 최대 작용응력이 135MPa 으로 도출되었다. 또한 동적내진해석시 적용한 응답스펙트럼 해석법과 모드조합법으로 계산된 최대응력은 183MPa 이었다. 이는 밸브 소재의 허용강도 대비 안전계수가 1.7 및 1.3 수준임을 확인하였다.

국내산 목재-콘크리트 복합적층재의 정적 휨 강도성능 (Static Bending Strength Performance of Domestic Wood-Concrete Hybrid Laminated Materials)

  • 변진웅;조영준;이제룡;박한민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.48-56
    • /
    • 2016
  • 이 연구에서는 환경부하가 적은 산림훼손지 생태복원용 단위격자틀을 개발하기 위하여 콘크리트와 국내산 침엽수 4종과 활엽수 3종을 각각 복합적층한 7종류의 목재-콘크리트 복합적층재를 제작하였고, 정적 휨 강도성능에 미치는 수종의 밀도의 영향을 조사하였다. 목재-콘크리트 복합적층재의 휨 탄성계수는 전반적으로 수종의 밀도에 비례하여 증가하였고, 대부분 콘크리트에 비해 높은 휨 탄성계수를 나타내어 복합적층에 의한 밀도감소와 탄성계수향상의 효과가 나타났다. 휨 탄성계수 실측치는 각 라미나의 탄성계수로부터 등가단면법을 이용하여 계산한 예측치보다 약간 낮은 값을 나타내었고, 그 차이는 10% 미만인 것이 확인되었다. 목재-콘크리트 복합적층재의 휨 비례한도 응력은 콘크리트보다 1.2-1.6배의 높은 값을 나타내었다. 목재-콘크리트 복합적층재의 휨 강도는 전반적으로 수종의 밀도에 비례하여 증가하였고, 복합적층에 의해 콘크리트의 그것보다 현저한 강도향상을 나타내어 목재-콘크리트 복합적층재는 환경부하가 적으면서 내구성을 지닌 생태복원용 재료로 응용가능 할 것으로 판단된다.

지반가속도에 의한 철근콘크리트 전단벽의 비선형 지진응답 및 파괴거동 (Nonlinear Seismic Response and Failure Behavior of reinforced Concrete Shear Wall Subjected to Base Acceleration)

  • 유영화;신현목
    • 한국지진공학회논문집
    • /
    • 제3권3호
    • /
    • pp.21-32
    • /
    • 1999
  • 지진가속도에 의한 부재의 지진거동 특성은 실험적인 방법 또는 등가의 정적실험으로부터 추정되어 온 것이 대부분이다 본 연구에서는 지진가속도에 의한 철근콘크리트 전단벽체의 지진응답 및 파괴거동 특성을 유한요소법을 사용한 해석적인 기법에 의해서 예측하였다 콘크리트 부재에서 균열은 필연적으로 발생하게 되며 이로 인한 부재의 강도 및 강성의 감소 철근의 항복 및 하중의 반복성으로 인한 균열의 개폐등이 수반된다 본 연구에서는 이와 같은 콘크리트와 철근의 비선형 특성을 고려한 이축응력상태에 대한 재료모델과 동적해석 알고리즘을 범용 수치해석기법인 유한요소법을 사용하여 해석프로그램으로 구현하였다 지진가속도를 받는 전단벽을 대상으로 지진응답 및 파괴거동등을 본 연구의 해석적인 방법으로 예측하였으며 그 결과를 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.

  • PDF

A Magnetic Energy Recovery Switch Based Terminal Voltage Regulator for the Three-Phase Self-Excited Induction Generators in Renewable Energy Systems

  • Wei, Yewen;Kang, Longyun;Huang, Zhizhen;Li, Zhen;Cheng, Miao miao
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1305-1317
    • /
    • 2015
  • Distributed generation systems (DGSs) have been getting more and more attention in terms of renewable energy use and new generation technologies in the past decades. The self-excited induction generator (SEIG) occupies an important role in the area of energy conversion due to its low cost, robustness and simple control. Unlike synchronous generators, the SEIG has to absorb capacitive reactive power from the outer device aiming to stabilize the terminal voltage at load changes. This paper presents a novel static VAR compensator (SVC) called a magnetic energy recovery switch (MERS) to serve as a voltage controller in SEIG powered DGSs. In addition, many small scale SEIGs, instead of a single large one, are applied and devoted to promote the generation efficiency. To begin with, an expandable mathematic model based on a d-q equivalent circuit is created for parallel SEIGs. The control method of the MERS is further improved with the objective of broadening its operating range and restraining current harmonics by parameter optimization. A hybrid control strategy is developed by taking both of the stand-alone and grid-connected modes into consideration. Then simulation and experiments are carried out in the case of single and double SEIG(s) generation. Finally, the measurement results verify that the proposed DGS with SVC-MERS achieves a better stability and higher feasibility. The major advantages of the mentioned variable reactive power supplier, when compared to the STATCOM, include the adoption of a small DC capacitor, line frequency switching, simple control and less loss.

Evaluation of wind loads and wind induced responses of a super-tall building by large eddy simulation

  • Lu, C.L.;Li, Q.S.;Huang, S.H.;Tuan, Alex Y.;Zhi, L.H.;Su, Sheng-chung
    • Wind and Structures
    • /
    • 제23권4호
    • /
    • pp.313-350
    • /
    • 2016
  • Taipei 101 Tower, which has 101 stories with height of 508 m, is located in Taipei where typhoons and earthquakes commonly occur. It is currently the second tallest building in the world. Therefore, the dynamic performance of the super-tall building under strong wind actions requires particular attentions. In this study, Large Eddy Simulation (LES) integrated with a new inflow turbulence generator and a new sub-grid scale (SGS) model was conducted to simulate the wind loads on the super-tall building. Three-dimensional finite element model of Taipei 101 Tower was established and used to evaluate the wind-induced responses of the high-rise structure based on the simulated wind forces. The numerical results were found to be consistent with those measured from a vibration monitoring system installed in the building. Furthermore, the equivalent static wind loads on the building, which were computed by the time-domain and frequency-domain analysis, respectively, were in satisfactory agreement with available wind tunnel testing results. It has been demonstrated through the validation studies that the numerical framework presented in this paper, including the recommended SGS model, the inflow turbulence generation technique and associated numerical treatments, is a useful tool for evaluation of the wind loads and wind-induced responses of tall buildings.