• Title/Summary/Keyword: equivalent form

Search Result 492, Processing Time 0.028 seconds

Value Numbering for Java Bytecodes Optimization in CTOC (CTOC에서 자바 바이트코드 최적화를 위한 Value Numbering)

  • Kim, Ki-Tae;Kim, Ji-Min;Kim, Je-Min;Yoo, Weon-Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.6 s.44
    • /
    • pp.19-26
    • /
    • 2006
  • Redundant expressions must be eliminated in order to apply optimization for expressions in SSA Form from CTOC. This paper applied VN(Value Numbering) for this purpose. In order to carry out VN, SSAGraph must be first generated to maintain the information in the SSA Form, equivalent nodes must be found and SCC(Strongly Connected Component) generated. Equivalent nodes are assigned with an identical valnum through SCC. We could confirm elimiations for many nodes that added at SSA Form process after VN. The valnum can be applied in optimization and type inference.

  • PDF

Equivalent Circuit Modeling of Rosen-type Multilayer Piezoelectric Transformer (Rosen형 적층 압전변압기의 등가회로 모델링)

  • Shin, Hoon-Beom;Lee, Yong-Kuk;Yu, Young-Han;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1099-1105
    • /
    • 2006
  • In this paper, the equivalent circuit model of a Rosen-type multilayer piezoelectric transformer(MPT) has been proposed based on the Mason's equivalent circuit model and the principle of single layer piezoelectric plate. From the piezoelectric direct and converse effects, the symbolic expressions between the electric inputs and outputs of the MPT have been derived from the equivalent circuit model. A simplified equivalent circuit model of the MPT whose driving part has a single input form has been proposed. The symbolic expressions of the driving part have been derived from the simplified equivalent circuit model and the model was compared with the multi-input equivalent circuit model through the simulation. In the comparisons between the simulation results and the experimental data, output voltage is 630 Vp-p in case of 11-layered MPT and 670 Vp-p for 13-layered MPT over the experiment range. As the load resistance increases, output voltage increases and saturates over $300k{\Omega}$ and the resonant frequency changes from 102 kHz to 103 kHz. The simulation and the experimental results agree well over different load resistances and frequencies.

Study on the analysis of impulse test wave in the short coil (layer)of transformer winding (변압기 권선(층간)단락시의 충격파시험파형분석에 관한 연구)

  • 박민호
    • 전기의세계
    • /
    • v.25 no.5
    • /
    • pp.75-78
    • /
    • 1976
  • The most difficult problem encountered in impulse test of transformer is the determination of exact fauly for coil layer short. This paper is to establish one of improved standards in the above case by means of wave form analysis, based on the equivalent circuits and experimental investigation. During the fault occurs, the local oscillation in fault circuit is applicable where as the reflection wave is utilized to the main circuit. The result current wave form at neutral impeadance point is similar to the wave form by impulse test and has the singular wave form respectively.

  • PDF

Determination of Equivalent Roughness for Estimating Flow Resistance in Stabled Gravel-Bed River: I. Theory and Development of the Model

  • Park, Sang-Woo;Lee, Sin-Jae;Jang, Suk-Hwan
    • Journal of Environmental Science International
    • /
    • v.17 no.11
    • /
    • pp.1203-1210
    • /
    • 2008
  • Flow resistance in a natural stream is caused by complex factors, such as the grains on the bed, vegetation, and bed-form, reach profile. Flow resistance in a generally stable gravel bed stream is due to protrudent grains from bed. Therefore, the flow resistance can be calculated by equivalent roughness in gravel bed stream, but estimation of equivalent roughness is difficult because nonuniform size and irregular arrangement of distributed grain on natural stream bed. In previous study, equivalent roughness is empirically estimated using characteristic grain size. However, application of empirical equation have uncertainty in stream that stream bed characteristic differs. In this study, we developed a model using an analytical method considering grain diameter distribution characteristics of grains on the bed and also taking into account flow resistance acting on each grain. Also, the model consider the protrusion height of grain.

S-Domain Equivalent System for Electromagnetic Transient Studies PART 2 : Frequency Dependent Network Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART 2 :주파수 의존 교류 시스템 등가)

  • Wang Yong P;Lee Hyun J;Chong Hyeng H;An Byung C;Kim Hae J
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.283-285
    • /
    • 2004
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. This paper presents the formulation for developing 1 & 2 port Frequency Dependent Network Equivalent (FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 & 2 Port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 & 2 port (FDNE) developed with Norton Equivalent network.

  • PDF

Experimental Study on the Probability-based Equivalent Linearization of a Friction Damper-Brace System (마찰감쇠기-가새 시스템의 확률분포 기반 등가선형화에 관한 실험적 연구)

  • Kang, Kyung-Soo;Park, Ji-Hun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.4 s.109
    • /
    • pp.394-403
    • /
    • 2006
  • A new equivalent linearization technique is proposed for a friction damper-brace system (FDBS) idealized as a elastoplastic system. The equivalent linearization technique utilizes secant stiffness and dissipated energy defined by the probability distribution of the extremal displacement of the FDBS. In addition, a conversion scheme is proposed so that an equivalent linear system is designed first and converted to the FDBS. For comparative study, an existing model update technique based on system identification is modified in a form appropriate to update single element. For the purpose of verification, shaking table tests of a small scale three-story shear building model, in which a rotational FDBS is installed, are conducted and equivalent linear systems are obtained using the proposed technique and the model update technique. Complex eigenvalue analysis is conducted for those equivalent linear systems, and the natural frequencies and modal damping ratios are compared with those obtained from system identification. Additionally, RMS and peak responses obtained from time history analysis of the equivalent linear systems are compared with measured ones.

The Quantitative Evaluation of Catchment Plan-Form Elongation (집수평면의 신장도에 대한 정량적 평가)

  • Kim, Joo-Cheol;Lee, Sang-Jin;Noh, Joon-Woo
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • In this study the concepts on the elongation, compactness and equivalent ellipse of catchment plan-forms are applied to the real basins considering their theoretical frameworks. The catchment plan-forms and corresponding equivalent ellipses, obtained from GIS, are inspected on downstream directions. As a result the catchment plan-forms seem to be the population of the basin shapes which come from the random interaction between two conjectures on Hack's law being controversial recently. The ratio of the maximum and minimum inertia moments of the catchment plan-form Ri is more sensitive to evaluate the elongation of the basin shapes than the ratio of the main channel length and diameter of circle which has the same area as the catchment plan-form E. The catchment plan-forms compactness measures show distinct aspects according to their different definitions. These results are caused by the difficulties to quantification of the shapes and the composite consideration with more than two compactness measures and the fractal analysis are therefore required to recover them.

  • PDF

The Informal Knowledge of Elementary School Students about the Concepts of Fraction (분수 개념에 관한 초등학생의 비형식적 지식)

  • Hong, Eun-Suk;Kang, Wan
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.12 no.1
    • /
    • pp.59-78
    • /
    • 2008
  • The purpose of this study was to research and analyze students' informal knowledge before they learned formal knowledge about fraction concepts and to see how to apply this informal knowledge to teach fraction concepts. According to this purpose, research questions were follows. 1) What is the students' informal knowledge about dividing into equal parts, the equivalent fraction, and comparing size of fractions among important and primary concepts of fraction? 2) What are the contents to can lead bad concepts among students' informal knowledge? 3) How will students' informal knowledge be used when teachers give lessons in fraction concepts? To perform this study, I asked interview questions that constructed a form of drawing expression, a form of story telling, and a form of activity with figure. The interview questions included questions related to dividing into equal parts, the equivalent fraction, and comparing size of fractions. The conclusions are as follows: First, when students before they learned formal knowledge about fraction concepts solve the problem, they use the informal knowledge. And a form of informal knowledge is vary various. Second, among students' informal knowledge related to important and primary concepts of fraction, there are contents to lead bad concepts. Third, it is necessary to use students' various informal knowledge to instruct fraction concepts so that students can understand clearly about fraction concepts.

  • PDF

A new finite element procedure for fatigue life prediction of AL6061 plates under multiaxial loadings

  • Tarar, Wasim;Herman Shen, M.H.;George, Tommy;Cross, Charles
    • Structural Engineering and Mechanics
    • /
    • v.35 no.5
    • /
    • pp.571-592
    • /
    • 2010
  • An energy-based fatigue life prediction framework was previously developed by the authors for prediction of axial, bending and shear fatigue life at various stress ratios. The framework for the prediction of fatigue life via energy analysis was based on a new constitutive law, which states the following: the amount of energy required to fracture a material is constant. In the first part of this study, energy expressions that construct the constitutive law are equated in the form of total strain energy and the distortion energy dissipated in a fatigue cycle. The resulting equation is further evaluated to acquire the equivalent stress per cycle using energy based methodologies. The equivalent stress expressions are developed both for biaxial and multiaxial fatigue loads and are used to predict the number of cycles to failure based on previously developed prediction criterion. The equivalent stress expressions developed in this study are further used in a new finite element procedure to predict the fatigue life for two and three dimensional structures. In the second part of this study, a new Quadrilateral fatigue finite element is developed through integration of constitutive law into minimum potential energy formulation. This new QUAD-4 element is capable of simulating biaxial fatigue problems. The final output of this finite element analysis both using equivalent stress approach and using the new QUAD-4 fatigue element, is in the form of number of cycles to failure for each element on a scale in ascending or descending order. Therefore, the new finite element framework can provide the number of cycles to failure at each location in gas turbine engine structural components. In order to obtain experimental data for comparison, an Al6061-T6 plate is tested using a previously developed vibration based testing framework. The finite element analysis is performed for Al6061-T6 aluminum and the results are compared with experimental results.