• Title/Summary/Keyword: equal order element

Search Result 76, Processing Time 0.024 seconds

Mechanical Splicing Characteristic of the Threaded Bar according to the Contact Conditions of the Transverse Rib (마디접촉조건에 따른 나사철근의 기계식 이음 특성)

  • Kim, J.M.;Choi, S.W.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.28 no.3
    • /
    • pp.145-153
    • /
    • 2019
  • The objective of this study is to analyze the mechanical splicing characteristic of the threaded bar according to the contact conditions of the transverse rib. In order to consider the contact conditions of the rib, selection of the main variables including the gap of the core diameter ($l_c$), rib angle (${\theta}$), and the number of contacts ($C_N$) of transverse rib was done. So as to analyze the splicing characteristic of the D51 threaded bar, a finite element (FE) simulation of the tensile test was conducted using the designed D51 threaded bar and coupler. Through FE simulation results, it was verified that the mechanical slicing characteristics varied based on the main design variables ($l_c$, ${\theta}$, and $C_N$). It was further confirmed that it was important to determine the $C_N$ in consideration of $l_c$. Additionally, the tensile test results of the D25 and D51 threaded bar combined with the couplers were similar to FE simulation results. Furthermore, to quantitatively evaluate FE simulation and test results, the calculation equation for the contacted projection area ratio (R) of the transverse rib was proposed. To secure a mechanical splicing joint of the threaded bar, it was established that the R calculated using the proposed equation had to be greater or equal to 40%.

Developing Algorithm of Automated Generating Schematic Diagram for One-dimensional Water Quality Model using Korean Reach File (한국형 Reach File을 이용한 1차원 수질모델 모식도 자동생성 알고리듬 개발)

  • Park, Yong Gil;Kim, Kye Hyun;Lee, Chol Young;Lee, Sung Joo
    • Spatial Information Research
    • /
    • v.21 no.6
    • /
    • pp.91-98
    • /
    • 2013
  • Government introduces a Total Maximum Daily Loads(TMDL) which can be implemented for total pollutant amounts in 2004. Normally, the local governments have been calculated the amounts of pollutant discharge of each watershed using a water quality model. However, among the input data to use the water quality model, creating a schematic diagram of the stream or the modeling usually requires considerable amount of time and efforts due to the manual work. Therefore, this study tried to develop an algorithm which automates the creation of a schematic diagram for water quality modeling using the Korean Reach File capable of river network analysis. Further, this study creates a schematic diagram with the shape of a stream utilizing GIS capabilities. The diagram can be easily analyzed with overlapping various spatial information such as pollution sources and discharge points. This study mainly has automated element segmentation algorithm to divide streamflows into equal distance using line graphic data of Koran Reach File. Also, automated attribute input algorithm has also been developed to enable to insert element order and type into elements using point graphic data of Korean Reach File. For the verification of the developed algorithm, the algorithm was applied to kyungan stream basin to see the acceptable results. To conclude, it was possible to automate generating of schematic diagram of water quality model and it is expected to be able to save time and cost required for the water modeling. In future study, it is necessary to develop an automatic creation system of various types of input data for water quality modeling and this will lead to relatively easier and simple water quality modeling.

A Study on a Classical Construction Paradigm in Modern Fashion (현대 패션에 나타난 고전적 조형 패러다임에 관한 연구)

  • Kim Hye-Young;Lee Shin-Young
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.6 s.59
    • /
    • pp.960-976
    • /
    • 2005
  • Classicism pursued beauty comprised of a perfect form, and beauty was perceived as a state of sufficiency. Accordingly, a completed and permanent beauty was sought after; as a result, a perfect and flawless form became the mainstream, and there was an effort to visualize the eternal proportional perfection. In classicism, forms were perfectly embodied with systematic inevitability and absolute inflexibility, by which an extremely clear aspect appeared. This study analyzes a classical construction paradigm in modern fashion according to the five categories: 'Harmony and order by numerical proportion', 'Clear form', 'Simplification of form and two-dimensional Seh-form', 'Completed contracture structure', and 'Pluralistic unification', and the respective formative characteristics are as follows. First, in terms of the formative aspect of modern fashion,'Harmony and order by numerical proportion' results from thorough observance of extreme and golden section (proportion of 5 :8) which was an aesthetic standard of beautiful body in classicism. Second, 'Clear form' appears in clothes as individual clearness of structural elements expressing each part of body, and shows a well-established form possible to be grasped with equal and clear contour line. Third,'Simplification of form and two-dimensional Seh-form' comes out as form composition, single line, single layer structure, two-dimensional form and arrangement of elements of clothes through the front viewpoint caused by 2D diagramming work while fashion-designing and producing. Also, it is seen that two-dimensional proportion which is composed of sections through various harmonious lines and sides according to the simple two-dimensional compatibility principle is accomplished. Fourth, 'Completed contracture structure' emerges as an expression of stationariness, in other words, fixation of an overall impression. This is a tendency that the overall form is grasped as a fixedly intact shape without a big change of the silhouette of clothes. Fifth, 'Pluralistic unification' means that it respectively emphasizes all the parts composing clothes by making them individually independent at the same time as each element is inclusively shown with the harmony of the overall silhouette of clothes and many other details. This study examined classical formative characteristics through a theoretical research on a formative paradigm revealing the classical style. Also, the significance of classical or rational value of art was illuminated by observing what characteristics a classical formation paradigm shows in modern fashion. As a result, classical characteristics in modern fashion prove that classicism is not a merely past construction style separated from the present but a construction paradigm deeply involved in our reason system.

  • PDF

The moment generated by the torque of the orthodontic rectangular wire : Three-dimensional finite element analysis (교정용 각형선재에 부여된 torque가 브라켓에 발생시키는 모멘트에 관한 유한요소법적 분석)

  • Ha, Do-Won;Kim, Young-Suk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.335-346
    • /
    • 2001
  • The purpose of this study was to investigate the ideal clinical torque(In the SWA rectangular wire, the torque by the angle between the plane part and twisted part to move the tooth) of the orthodontic rectangular wire which produce the proper labiolingual movement of the single tooth during finishing stage of the orthodontic treatment. The clinical torque is the sum of the play and the active torque which generates the moment at the bracket. The play is calculated by the formula and the active torque is calculated by the computer aided three-dimensional finite element method. The finite element model was consist of the three brackets which formed a row and 3 kinds of orthodontic rectangular wire(stainless steel, TMA, NiTi) which inserted in brackets. Both sides of the model were twisted and the moment generated in the center bracket was calculated. The sizes of seven wires which were used commonly were .016'X.022', .017'X.022', .017'X.025', .018'X.025', .019'X.025', .020'X.025', .021'X.025'. In 018' bracket, 016'X.022', .017'X.022', .017'X.025' wires were inserted and in 022' bracket, all the sizes of wires except .016'X.022' were inserted and tested. The following conclusions could be drawn from this study. 1. The moments generated on the same size of the wires by the same active torque were equal regardless of the bracket slot size. 2. The moments were increased with the size of the wires. The moment generated on the .021'X.025' wire was about 1.75 times as large as that on the .016'X.022' wire regardless of the material. 3. The moments were increased in the order of the NiTi, TMA stainless steel. The moment of the TMA wire was 0.35 times as small as that of the stainless steel wire and the moment of the NiTi was0.16 times as small as that of the stainless steel wire. 4. The moment was decreased as the interbracket distance was increased. 5. To get a desired moment with the specific size and material of the wire on the specific bracket slot, the formula and the results were displayed.

  • PDF

A Biomechanical Modeling of Human Pharyngeal Muscular Dysfunction by Using FEM(Finite Element Method) (유한요소법을 이용한 인두의 기능이상에 대한 생체역학적 모델)

  • Kim Sung Jae;Bae Ha Suk;Choi Byeong Cheol;Kim Sung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.6 s.81
    • /
    • pp.515-522
    • /
    • 2003
  • Pharynx is a system transporting foods by peristaltic motion(contraction and expansion movement! into the esophagus and functioning as airway passages. In this study, structural changes of pharyngeal dysfunction are analyzed by biomechanical model using CT and FEM(finite clement method). Loading condition was assumed that equal pressure was loaded sequentially to inside of pharyngeal tissue. In order to analyze the pharyngeal muscular dysfunction by biomechanical model. the pharyngeal dysfunctions was classified into 3 cases. Taking into account the clinical complication by neuromuscular symptoms such as pharyngeal dysfunction after stroke. we assumed that a change of material property is caused by muscular tissue stiffness. A deformation of cross sectional area of the pharynx is analyzed increasing the stiffness $25\%,\;50\%,\;75\%$ in each case on the basis of stress-strain relationship. Based on three-dimensional reconstruction of pharyngeal structure using limited factor - techniques and the optimization procedure by means of inverse dynamic approach. the biomechanical model of the human pharynx is implemented. The results may be used as clinical index illustrating the degree of pharyngeal muscular dysfunction. This study may be used as useful diagnostic model in discovering early deglutitory impediment caused by physiological or pathological pharyngeal dysfunction.

A Study on the Nurse's Due Care in Medical Malpractice (의료과오시(醫療過誤時) 간호사의(看護師)의 주의의무(注意義務)에 관한 연구(硏究))

  • Kang, Sun-Joo
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.1
    • /
    • pp.113-136
    • /
    • 1999
  • There are some new trends in judgments concerning medical malpractice. which include emphasis on medical professionals' explanation duty in order to materialize patient's rights of self-determination. Now, patient is not a mere subject of medical and nursing care any more, but a subject, participating in medical practice on equal terms with medical professionals. Legal accountability is no limited to nurses in advanced practice: it is a recognized fact of life for every practicing nurse. whether she is an RN employed as a staff nurse in a hospital, a Certified Nurse-Midwife in independent practice or a patient's home. Therefore, it is essential for nurses to be as familiar as possible with the legal guidelines that govern their patient care responsibilities. However there are only a few studies focused on nursing negligence. To define nurse's civil liability in medical malpractice, it is necessary to indentify both legal nursing behaviors and nurse's due care in those nursing behaviors. So this paper focused on nurse's due care, especially in nursing malpractice. To clarify nurses' due care. chapter II has focused on nursing behavior and the scope of nursing practice based on the medical law and health care related study results. Chapter III deals with the content and scope of nurse's due care. Generally. negligence is defined as not doing something which a resonable person. guided by those ordinary considerations which or dinarily regulate human affairs. would do. or doing something which a resonable and prudent man would not do. Next. it describes how we can set the standard of due care in nursing practice. There is objective factors and subjective factors. And we also discuss about the limitation of due care in nursing practice. Finally. chapter IV deals with the case studies related to nursing negligence in the situation of determination. Now', patient is not a mere subject of medical and nursing care any more, but a subject participating in medical practice on equal terms with medical professionals. Legal accountability is not limited to nurses in advanced practice; it is a recognized fact of life for every practicing nurse. whether she is an RN employed as a staff nurse in a hospital. a Certified Nurse-Midwife in independent practice or a patient's home. Therefore, it is essential for nurses to be as familiar as possible with the legal guidelines that govern their patient care responsibilities. However. there are only a few studies focused on nursing negligence. To define nurse's civil liability in medical malpractice, it is necessary to identify both legal nursing behaviors and nurse's due care in those nursing behaviors. So this paper focused on nurse's intravenous injection. post operation nursing care. blood transfusion. and patient nursing care. The result of this paper is as follows. First. there are several cases dealing with nurse's negligence in nursing practice. however, those cases didn't judge nurse's due care based on individual -specific standard but general-objective standard. Second, there is a tendency to put an emphasis on the principal of belief to distinguish who has the liability in the case of medical malpractice among medical care team. So nurses shoud practice nursing care more actively to protect themselves and patients because there is an effort to form professional nurse system and the scope of nursing practice will be deeper and broader. Third, standard of care is a necessary element in establishing negligence. If a nurse is able to meet the standard of care, no breach will be found.

  • PDF