• Title/Summary/Keyword: environmental simulation

Search Result 3,788, Processing Time 0.043 seconds

A Numerical Simulation of Air Pollutant Concentration Considering Land and Sea Breeze in Ulsan Area (해륙풍을 고려한 울산지역 대기오염물질농도의 수치모의)

  • 이화운;원경미;정우식;오은주;김민선;도우곤
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.933-943
    • /
    • 2002
  • The urban pollution if affected by local environmental, so it is necessary to consider area characteristics such as emission source and meteorological phenomena, in studying urban air pollution. Ulsan is laocated on south-east coast and has many industrial facilities, so many people have concerned about air pollution. This study contain conducting numerical simulation of air pollutant concentration considered land and sea breeze in Ulsan area with the numerical model.

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

A Study of Life Cycle Assessment in Shipyards Layout using a Discrete Event Simulation Engine (이산 사건 시뮬레이션 엔진을 이용한 조선소 레이아웃의 전과정평가 적용 연구)

  • Lee, Dong-Kun;Nam, Seung-Hoon;Shin, Jong-Gye
    • Journal of the Korea Society for Simulation
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • In recent days, global shipbuilding companies have been showing great interest in eco-friendly ship products and trying to reduce environmental pollution - harmful gas and dust in shipbuilding process. Following this trend, Life Cycle Assessment (LCA) was carried out to an application of shipyards layout. LCA is a technique used to assess environmental impacts during the life cycle of products and systems. Until now, LCA has been used through ISO 14040 in somewhat limited industries, such as Building Life Cycle Assessment. Thus, this study analyzes the shipyard layout planning framework and builds life cycle inventory along with the simulation model structure to evaluate environmental impacts.

Evaluation of Ensemble Approach for O3 and PM2.5 Simulation

  • Morino, Yu;Chatani, Satoru;Hayami, Hiroshi;Sasaki, Kansuke;Mori, Yasuaki;Morikawa, Tazuko;Ohara, Toshimasa;Hasegawa, Shuichi;Kobayashi, Shinji
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.3
    • /
    • pp.150-156
    • /
    • 2010
  • Inter-comparison of chemical transport models (CTMs) was conducted among four modeling research groups. Model performance of the ensemble approach to $O_3$ and $PM_{2.5}$ simulation was evaluated by using observational data with a time resolution of 1 or 6 hours at four sites in the Kanto area, Japan, in summer 2007. All groups applied the Community Multiscale Air Quality model. The ensemble average of the four CTMs reproduced well the temporal variation of $O_3$ (r=0.65-0.85) and the daily maximum $O_3$ concentration within a factor of 1.3. By contrast, it underestimated $PM_{2.5}$ concentrations by a factor of 1.4-2, and did not reproduce the $PM_{2.5}$ temporal variation at two suburban sites (r=~0.2). The ensemble average improved the simulation of ${SO_4}^{2-}$, ${NO_3}^-$, and ${NH_4}^+$, whose production pathways are well known. In particular, the ensemble approach effectively simulated ${NO_3}^-$, despite the large variability among CTMs (up to a factor of 10). However, the ensemble average did not improve the simulation of organic aerosols (OAs), underestimating their concentrations by a factor of 5. The contribution of OAs to $PM_{2.5}$ (36-39%) was large, so improvement of the OA simulation model is essential to improve the $PM_{2.5}$ simulation.

Construction of Oil-Spill Warning System based on Remote Sensing/Numerical Model and Its Application to the Natural Resource Damage Assessment and Restoration System

  • Goto, Shintaro;Kim, Sang-Woo
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.243-248
    • /
    • 1999
  • From the lessons after the Nakhodka oil-spill in Jan. 1997, oil slick detection by using remote sensing data and assimilating the data to the simulation program is important for monitoring the oil-drift pattern. For this object, we are going to construct the oil-spill warning system for estimating the oil-drift pattern using remotesensing/numerical simulation Model. Additionally we plan to use this system for restorating oil-spill damage domestically, such as estimating the ecological damage and making the priority fur restorating the oil-spilled shoreline. This report is intended to summarize the role of geo-informatics in the oil spill accident by not only paying attention to the effect of information provision/information management via the map, but also reporting the interim result in part based on the details discussed in the processes of recovery support and environmental impact assessment during the Nakhodka's accident.

  • PDF

An impact of meteorological Initial field and data assimilation on CMAQ ozone prediction in the Seoul Metropolitan Area during June, 2007 (기상 모델의 초기장 및 자료동화 차이에 따른 수도권 지역의 CMAQ 오존 예측 결과 - 2007년 6월 수도권 고농도 오존 사례 연구 -)

  • Lee, Dae-Gyun;Lee, Mi-Hyang;Lee, Yong-Mi;Yoo, Chul;Hong, Sung-Chul;Jang, Kee-Won;Hong, Ji-Hyung
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.609-626
    • /
    • 2013
  • Air quality models have been widely used to study and simulate many air quality issues. In the simulation, it is important to raise the accuracy of meteorological predicted data because the results of air quality modeling is deeply connected with meteorological fields. Therefore in this study, we analyzed the effects of meteorological fields on the air quality simulation. This study was designed to evaluate MM5 predictions by using different initial condition data and different observations utilized in the data assimilation. Among meteorological scenarios according to these input data, the results of meteorological simulation using National Centers for Environmental Prediction (Final) Operational Global Analysis data were in closer agreement with the observations and resulted in better prediction on ozone concentration. And in Seoul, observations from Regional Meteorological Office for data assimilations of MM5 were suitable to predict ozone concentration. In other areas, data assimilation using both observations from Regional Meteorological Office and Automatical Weather System provided valid method to simulate the trends of meteorological fields and ozone concentrations. However, it is necessary to vertify the accuracy of AWS data in advance because slightly overestimated wind speed used in the data assimilation with AWS data could result in underestimation of high ozone concentrations.

Influences of Ice Microphysical Processes on Urban Heat Island-Induced Convection and Precipitation (얼음 미시물리 과정이 도시 열섬이 유도하는 대류와 강수에 미치는 영향)

  • Han, Ji-Young;Baik, Jong-Jin
    • Atmosphere
    • /
    • v.17 no.2
    • /
    • pp.195-205
    • /
    • 2007
  • The influences of ice microphysical processes on urban heat island-induced convection and precipitation are numerically investigated using a cloud-resolving model (ARPS). Both warm- and cold-cloud simulations show that the downwind upward motion forced by specified low-level heating, which is regarded as representing an urban heat island, initiates moist convection and results in downwind precipitation. The surface precipitation in the cold-cloud simulation is produced earlier than that in the warm-cloud simulation. The maximum updraft is stronger in the cold-cloud simulation than in the warm-cloud simulation due to the latent heat release by freezing and deposition. The outflow formed in the boundary layer is cooler and propagates faster in the cold-cloud simulation due mainly to the additional cooling by the melting of falling hail particles. The removal of the specified low-level heating after the onset of surface precipitation results in cooler and faster propagating outflow in both the warm- and cold-cloud simulations.

Development of a system dynamics computer model to simulate the operational effects of the new environmental technology certification system (환경신기술인증제도의 운영효과를 모의하기 위한 시스템다이내믹스 컴퓨터 모델의 개발)

  • Kim, Taeyoung;Park, Suwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.105-114
    • /
    • 2020
  • In this study, based on the System Dynamics (SD) methodology, the interrelationship between the factors inherent in the operation of the New Technology Certification System (NTCS) in Korea was identified by a causal map containing a feedback loop mechanism in connection with 'new technology development investment', 'commercialization of new technology', and 'sales by new technology'. This conceptualized causal map was applied to the simulation of the operations of the New Excellent Technology and Environmental Technology Verification System (NET&ETV) run by the Ministry of Environment among various NTCSs in Korea. A SD computer simulation model was developed to analyze and predict the operational performance of the NET&ETV in terms of key performance indices such as 'sales by new technology'. Using this model, we predicted the future operational status the NET&ETV and found a policy leverage that greatly influences the operation of the NET&ETV. Also the sensitivity of the key indicators to changes in the external variables in the model was analyzed to find policy leverage.

The Analysis of Optimal Site Condition for Photovoltaic System and Green Roof Planting through Sunlight Component Simulation of Rooftop Area (옥상공간의 태양광 자원 해석을 통한 PV 시스템 및 녹화식재에 대한 적지조건분석)

  • Kim, Tae Han;Park, Dae Keun;Kwan, Ji Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.4
    • /
    • pp.27-40
    • /
    • 2013
  • These day morden cities have serious climatic problems due to enviornmental load caused by excessive development of urbanization. As technological improvement to answer to various ecological disasters and climate changes are also called on the field of construction, inter-disciplinary studies linked to the estabilishment of sustainable energy generation systems and enviornmental control is needed in a consilient point of view. This study aims to analyse optimal site conditions for photovoltaic system and green roof planting through solar radiation simulation in a integrated perspective. In so doing, it seeks to proffer basic study for developing a sound use of roof area that is sustainable in environmental and resources aspects. A computer simulation showed that, in the case of total seasonal solar radiation, summer season resulted 312.5kWh in 35% of total annual solar radiation. This season indicated the lowest radiation rate of the year for direct sunlight in 45.8% of total seasonal solar radiation. Due to such solar radiation simulation, at the largest optimal planting area, Glechoma hederacea var. longituba secured $719.16m^2$ of gross roof area.