이상적인 음료수 공급을 위한 수질관리에 관한 연구 (Study on the Water Management to get High Quality of Drinking Water)

  • 김형석;신현덕;박경석
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF

1차소성 폐도자기로부터 알루미나 회수 (Recovery of Alumina from the First Calcined Waste Pottery)

  • 김재용;서완주;이진수;박수길;엄명헌
    • 환경위생공학
    • /
    • 제15권1호
    • /
    • pp.62-68
    • /
    • 2000
  • This study was investigated to the recovery of alumina from the first calcined waste pottery using alkaline sintering. This study was based on calcination result of a commercial ${\alpha}-Al2_O_3$ with NaOH powder. $NaAlO_2$ was formed by calcination of ${\alpha}-Al_2O_3$ with NaOH and conversion of $NaAlO_2$ from ${\alpha}-Al_2O_3$ was 91.4% at calcination condition ; weight ritio of $NaOH/{\alpha}-Al2_O_3$ 1.5, $800^{\circ}C$, and 90min. The first calcined waste porrery from the manufacturing Procedure of H Ltd. was grinded to 170/270mesh by a ball mill and calcined over $500^{\circ}C$ with NaOH powder. The calcined sample was dissolved in $25^{\circ}C$ water and sodiumaluminosilicate solid was formed. After filtration, the contained aluminum was leached out by dissolving sodiumaluminosilicate solid in 1N HCl. We estimated the efficiency of Al extraction from waste pottery by ICP analysis and NaOH was added to the filtrate and then aluminum compound was precipitated with $Al(OH)_3$ and recovered. The investigation was carried out with the variables ; the calcination temperature($500-900^{\circ}C$), the calcination time(30~90min), and the weight ratio of NaOH/waste pottery(0.5~1.5). The treatment efficiency of the waste pottery and the recovery of Al as 97.9%, 91.9% were obtained under the optimum conditions as followed ; the weight ratio of NaOH/waste pottery was 1.5 and the calcination conditions were $900^{\circ}C$ and 60min.

  • PDF

대기오염에 의한 치과위생사의 자각증상 특성 (A Sbjective Symptom on Outdoor Air Quality in Dental Hygienist)

  • 지동하;최미숙;손부순
    • 환경위생공학
    • /
    • 제22권2호
    • /
    • pp.1-8
    • /
    • 2007
  • This research is based on self-filling survey which 656 dental hygienists who work in, seoul, the metropolitan area, jeon-buk area participated on July 2006 through August 2006. This survey was analyzed the relationship between the subjective symptoms(6 types) and outdoor air quality($O_3,\;NO_2,\;CO,\;SO_2,\;PM_{10}$) As follows analyzed results. The health condition of dental hygienists were "Feel Good" more than 50% in last month. The experience the symptoms level is higher then non-experience level in "Dry eye, itch, smarting", "Headaches", "Fatigue and sleepiness", "Red eye", "Hypersensitivity", "Dorsalgia, omarthralgia, cervicodynia". We anticipated that the more experience the subjective symptom the more likely it is that outdoor air quality will be high rate level. But we could not find the uniformity in metropolitan-area and seoul-area. In the case of jeonbuk area, the group's pollution density levels which experienced the subjective symptom were appeared high rate than inexperienced group except $SO_2$. It probably comes from sensibility for an air pollution in this area. Dental hygienists who work in jeonbuk area have an unusual sensibility for an air pollution because outdoor air quality of jeonbuk area was rule good rather than others area. especially $SO_2$ was revealed out even though low rate level in inexperienced group it is that the number of cars in jeonbuk area is increasing rapidly.

혼합응집제에 의한 자연유기물질 제거에 미치는 영향 인자 (Influencing Factors on NOM Removal using Blended Coagulants)

  • 명복태;우달식;최종헌;문철훈;이윤진;조영태;조관형;남상호
    • 환경위생공학
    • /
    • 제16권3호
    • /
    • pp.96-103
    • /
    • 2001
  • This study was carried out to investigate the major factors for the removal of NOMs (Natural Organic Matters) by alum ferric chloride and blended coagulants that consisted of alum and ferric chloride. Investigated factors were pH, the dosage of coagulant, alkalinity, hardness and bloc strength. The particle size contained in the test water came from the Han River was also measured. DOC(Dissolved Organic Carbon) removal at pH 6 was two to three times higher than at pH 8.5. The blended coagulant showed 9 to 10 percent higher DOC removal efficiency and 2 to 4 percent higher turbidity under the same condition. Alkalinity consumption of alum, ferric chloride and blended coagulant was 81%, 90% and 86% of theoretical value, respectively. The limit concentration of alkalinity to avoid pin floe was 10 mg $CaCO_3/L$ when alum was used. Hardness had no apparent effect on coagulation. The residual turbidity and $UV_{254}$ showed a tendency of increasing with floc strength($sec^{-1}$) increase. The order of floe strength was the following; alum >blended coagulant > ferric chloride. The particle counter test showed 89 percent of the small particle size(SPS, $1~5{\;}{\mu}textrm{m}$) and 11 percent of the medium to large particle size(M.LPS, $5~125{\;}{\mu}textrm{m}$). At PH7.85, the particle removal efficiencies of SPS($1~5{\;}{\mu}textrm{m}$) and M.LPS($5~125{\;}{\mu}textrm{m}$) in the coagulation process were 81% and 95%, respectively.

  • PDF

악취성분중 황화합물에 대한 기기분석법의 적용 (Application of Analytical Instrument Method for Determining Level of Malodorous Sulfur Compounds.)

  • 유병태;최종욱;조기찬;이충언;김건흥
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.117-123
    • /
    • 1999
  • The analytical instrument method was applied to analyze malodorous sulfur compounds emitted from industrial fields. Six factories and two sites which release malodorous substances into ambient air were selected to determine the level of hydrogen sulfide($H_2S$), methylmercaptan(MeSH), dimethyl sulfide($Me_2S$), and dimethyl disulfide($Me_2S_2$) using automated thermal desorption system (STD400) and GC-FPD in summer and fall seasons of 1999. The Air sampler for ATD400 uses a small pump to draw sample and a mass flow controller to adjust sample amount without using a dilution apparatus. The trap temperature of ATD400 reached to $-80^{\circ}$ by supplying liquid nitrogen and $H_2S$ can be analyzed under this condition. The recovery rates of $H_2S$, MeSH, $Me_2S$, and $Me_2S_2$ of odorous sulfur compounds standard were shown 98.2%, 93.6%, 98.2%, 99.4% respectively. The concentrations of $Me_2S$ at outside boundary of G market, L factory, and J factory were 0.018ppm, 0.021ppm, 0.032ppm in summer, respectively. The concentration of $H_2S$ at Nanjido landfill was 1.167ppm in summer, but that of $H_2S$ was not detected in fall because of soil covering. The concentration of H2S and $Me_2S_2$ at inside of Chonggye stream were 0.564ppm and 1.045ppm in summer, while those of H2S and Me2S2 were 0.285ppm and 0.465ppm in fall, respectively.

  • PDF

유기용제 측정용 흡착관 개발을 위한 AC 및 ACF의 흡착특성 (Desorption characteristics of Activated Carbon and Activated Carbon Fiber by Development of Sorbent Tube for Measurement of Organic Solvent)

  • 원정일;김기환;신창섭
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.99-109
    • /
    • 2002
  • Charcoal $tube/CS_2$ method are more popularly used than any other in the measurement of the working environment for the exposure evaluation of organic solvent, but it is some weak points that the lower accuracy can be obtained on the polar materials and within the range of the low concentration. Thus solvent desorption method has been developed to make accuracy higher and to overcome some weak points. However, because of high price of adsorption tube for thermal desorption and the short of study on its application to the working environment, it is not popularly used in the domestic industrial hygiene fields. This dissertation aims to develop thermal desorption and adsorption tubes for measuring organic solvents in the working environment, by comparing and analyzing breakthrough condition and adsorption capacity with ACF. Specific surface area of ACF used in this study is wider than the one of AC and micropore of ACF related with adsorption has been developed, and adsorption velocity and adsorption amount are very excellent by linking a pore of surface and an inside well into micropore. 1. Result of analysis on physical characteristics of adsorbent, the specific surface area of ACF was 1.3 times higher than that of AC. Distribution ratio of micropore related to adsorption was 94% on ACF and AC. Result of SEM, micropore of the AC is opened to the surface. In contrast, ACF shows that extremely fast adsorption speed. Because of micropore are exposed on the surface and penetrate through each other. 2. Breakthrough characteristics of adsorbents was not different from slop of breakthrough curve. The effluent concentration reaches 10% of initial concentration($C_{out}/C_{in}=0.1$, break point) of ACF was 30~316min longer than that of AC. Therefore, the adsorption capacities of ACF was 1.1~4.6 times higher than that of AC. ACF can be used as a proper adsorbent for measurement of organic solvent.

안양천 수계의 저서무척추동물 군집구조 (Community Structure of Benthic Macroinvertebrates in the Water System of Anyang Stream in Korea)

  • 배경석;윤종철;이순희;조석주
    • 환경위생공학
    • /
    • 제19권3호
    • /
    • pp.40-51
    • /
    • 2004
  • Community structure of benthic macroinvertebrates in the water system of Anyang Stream was analyzed from August, 2002 to April, 2003. Species number of benthic macroinvertebrates was 78 species, 33 families, 11 orders, 5 classes in 3 phyla. They were collected 49 species at 1st survey, 51 species at End survey and 53 species at 3rd survey, respectively. Species numbers at each tributary were 43 species at the Wanggok Stream, 44 species at the Mokgam Stream, 33 species at the Ohjeon Stream and 26 species at the Hakeu Stream, while it was only 9 species at the Dangjeong Stream. Species number of the main course of Anyang Stream was 24 species. Dominant species of benthic macroinvertebrates at the Wanggok, Ohjeon and Hakeu Stream were Baetis fuscatus, Alainites muticus, Physa acuta and chironominae sp. They were mainly intermediate and tolerant species. Dominant species and subdominant species of the Dangjeong Stream were Limnodrilus socialis, Psychoda KUa and Telmatoscopus KUa as indicator species for severe sewage pollution. Dominant species at Geumjeong-dong and KUa bridge in the main course of Anyang Stream were Physa acuta, Limodrilus gotoi, Chironominae sp., Species diversity indices at the Mokgam Stream were $high(3.53\~4.28\;range)$ and those of the Hakeu, Wanggok and Ohjeon Stream were some what high$(2.00\~3.13\;and\;2.34\~3.10\;range)$. But, species diversity indices in the Dangjeon Stream were low$(1.36\~1.70\;range)$ too. and those of the main course of Anyang Stream were low$(0.86\~1.79\;range)$ too. Species richness indices in the Wanggok and Mokgam Stream were very high$(3.55\~4.02\;and\;2.96\~5.31\;range)$ and those of Geumjeong-dong and Kia bridge in the main course of Anyang Stream were low$(0.89\~1.98\;range)$. Stream bed and riparian bank of middle reach in the Wanggok Stream were good condition and water was clean. The Mokgam Stream had various microhabitats, good water weed area, hetero geneous substrates and etc.. And, stream bed in the Hakeu Stream was in good condition. So, above streams should be continuously in good ecological condition and useful area for citizens.

촉매첨가에 의한 병원폐플라스틱의 열분해 처리에 관한 연구 (A Study on Hospital Wasted Plastic by the Pyrolysis over Catalyst)

  • 윤오섭;김수생
    • 한국환경보건학회지
    • /
    • 제13권2호
    • /
    • pp.51-63
    • /
    • 1987
  • We identified pyrolysis condition, effect of catalyzer and pyrolysis mechanism through contact decomposed method by adding Bentonite in waste plastic of hospital solid waste. The result from this study were summarized as the followings: 1. The optimum fuel oil were obtained when hospital wasted plastic (P.P) and Bentonite were mixed in the ratio of 30:1. 2. Maximum absorption wave of hospital wasted plastic (P.P) appeared at 2900cm$^{-1}$, 1480cm$^{-1}$, 1360cm$^{-1}$ and 1180 cm$^{-1}$ by FT-IR and the plastics were identified and confirmed. 3. Reaction temperature of hospital wasted plastic started at 360$\circ$C, proceed rapidly at 437.5$\circ$C and finished at 481$\circ$C. The residue was 0.729%. When bentonire was added started at 318$\circ$C, proceed rapidly at 399.5$\circ$C and finished at 449.3$\circ$C, the residue being 4.23%. 4. Pyrolysis products of hospital wasted plastic were about 90 kinds. The Main components were 2-Heptene-3-ethyl-4-trimethyl (27.4%), 1-Heptene-2-isobutyl-6-methyl (8.6%) and 1-Heptene decene (7.7%). There was little component difference at different temperature. This is the result from stability of decomposition product. 5. Pyrolysis efficiency increased by the addition Bentonire. 6. Some of the Environmental and Sanitary problems could be solved by the pyrolysis of hospital wasted plastic and the decomposed products were to be used as fuel oil.

  • PDF

학교 급수위생에 관한 연구 (A Survey of Sanitation of the Water Supply System in Schools)

  • 권은미
    • 한국환경교육학회지:환경교육
    • /
    • 제3권1호
    • /
    • pp.125-129
    • /
    • 1992
  • The purpose of this study was to investigate the condition of school water supply systems and to provide a way to supply safe and sanitary water in schools. In 1991 present, 56.9% of schools in the whole nation are provided with water supply system. And in urban schools, the percentage of small water supply system was larger than that in city. In the survey on water quality of supply water in Seoul city, the items violating the water quality standard were total bacteria, Zinc and Manganse. For supply the safe drinking water changing the old water mains and executing periodical water quality surveys are needed in addition regulations on school supply water and sanitation are also necessary to the drinking water management in schools.

  • PDF

시유의 유통기간 결정에 관한 학문적 고찰 (Scientific Consideration in Determining Shelf Life of Market Milk)

  • 최석호
    • Journal of Dairy Science and Biotechnology
    • /
    • 제22권1호
    • /
    • pp.27-35
    • /
    • 2004
  • The shelf lift of market milk should be determined based on the flavor which is influenced by environmental and sanitary conditions of dairy farm, milk processing plant, and storage and transportation facility as well as compositional quality, such as protein and fat, of the milk itself. The legal shelf life of market milk is often limited by microbiological quality, e.g. total bacterial count, coliform count, and food poisoning bacteria. The bacteria involved with milk spoilage and poisoning are originated from bacteria contaminating milk after pasteurization or spores surviving the heat treatment of pasteurization. The important factors which influence the shelf life of market milk are microbiological quality of raw milk, pasteurization condition, post-pasteurization contamination, and temperature during storage and transportation. The organoleptic quality and shelf life of market milk should be further improved by satisfying the consumer's taste, which depends on somatic cell count and bacterial count of milk, feed quality, foreign substance in milk, and physical treatment during processing and transportation.