• Title/Summary/Keyword: environmental parameter

Search Result 1,621, Processing Time 0.029 seconds

Improvement of Analytical Probabilistic Model for Urban Storm Water Simulation using 3-parameter Mixed Exponential Probability Density Function (3변수 혼합 지수 확률밀도함수를 이용한 도시지역 강우유출수의 해석적 확률모형 개선)

  • Choi, Daegyu;Jo, Deok Jun;Han, Suhee;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.345-353
    • /
    • 2008
  • In order to design storage-based non-point source management facilities, the aspect of statistical features of the entire precipitation time series should be considered since non-point source pollutions are delivered by continuous rainfall runoffs. The 3-parameter mixed exponential probability density function instead of traditional single-parameter exponential probability density function is applied to represent the probabilistic features of long-term precipitation time series and model urban stormwater runoff. Finally, probability density functions of water quality control basin overflow are derived under two extreme intial conditions. The 31-year continuous precipitation time series recorded in Busan are analyzed to show that the 3-parameter mixed exponential probability density function gives better resolution.

Design of a Compensation Algorithm for Thermal Infrared Data considering Environmental Temperature Variations (주변 환경 온도 변화를 고려한 열화상 온도 데이터의 보정 알고리즘 설계)

  • Song, Seong-Ho
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.261-266
    • /
    • 2021
  • This paper suggests design methodology for thermal infrared data correction algorithms considering environmental temperature variations. First, a thermal infrared measurement model is suggested by a parameter-dependent first-order input-output equation using the relationship between infrared measurement data and model environmental parameters. In order to compensate the influence of environmental temperatures on infrared data, a compensation function is identified. Through experiments, the proposed algorithm is shown to reduce the influence of environmental temperatures on the infrared data effectively.

Adequacy Evaluation of Fish Intake Parameter used for Human Health Risk Assessment to Derive Freshwater Quality Criteria in Korea (국내담수지역 인체위해성기반 준거치 산정에 활용되는 어류섭취량인자 타당성 평가)

  • An, Youn-Joo;Nam, Sun-Hwa
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.3
    • /
    • pp.364-370
    • /
    • 2011
  • Water quality criteria for human health protection are derived based on the human health risk assessment. Water quality criteria in Korean freshwater bodies have been derived according to the equations developed by the US Environmental Protection Agency. The equations include the fish intake parameter, which is very important factor that significantly influences on the criteria derivation. So far, several fish intake values were used in human health risk assessment for water quality standards and effluent standards. However, these values are not consistent and they refer to various sources. Therefore, there is a need to suggest the most appropriate value of fish intake parameter to derive freshwater quality criteria in Korea. In this study, national and international fish intake values were widely collected and evaluated to select the adequate value of fish intake parameter that can be applied in Korea. The USEPA presented fish intake parameter as the 17.5 g/day for general adults and sport fishers and 142.4 g/day for subsistence fishers. In Korean reports, wide range values of 2 to 67.7 g/day were suggested as fish intake value. These values included finfish and shellfish intakes in common but had various habits. This study found that the 52.4 g/day suggested in Korean Exposure Factors Handbook published by the Ministry of Environment in 2007 seemed to be the suitable fish intake parameter to derive the freshwater quality criteria in Korea. The value is based on water corrected intakes of finfish and shellfish present in freshwater and coastal areas. We expect that this report can be useful to select suitable fish intake value in human health risk assessment for establishing freshwater quality standard in Korea.

Establishment of Rainfall and Contaminants Runoff Modeling System for the Joman River Watershed Using SWMM (SWMM을 이용한 조만강 유역 강우-오염물 유출모델링시스템 구축)

  • Lee, Yong-Chin;Yoon, Young-Sam;Lee, Nam-Joo
    • Journal of Environmental Science International
    • /
    • v.18 no.9
    • /
    • pp.983-992
    • /
    • 2009
  • The purpose of the present study is to analyze pollutant runoff characteristics from non-point sources in Joman River basin. The present study contains analyzed results of rainfall and SS, BOD, COD, TN, TP runoff from Joman River basin. This study contains a sensitivity analysis of parameters that affect the simulation results of rainfall and pollutants runoff. Result of the sensitivity analysis shows that proportion of watershed and impervious areas is the most sensitive to peak discharge and total flowrate for rainfall runoff and that WASHPO is the most sensitive parameter for pollutants runoff. For parameter estimation and verification, flowrate and water quality is measured at the Kangdong Bridge in Haeban stream. A single rainfall event is use to perform parameter estimation and verification. Results of the present study show that total pollutant loads of Joman River basin is 11,600 ton of SS, 452 ton of BOD, 1,084 ton of COD, 515 ton of TN, and 49 ton of TP, respectively. In addition, it is found that contribution ratio of non point source and total source is 89% of SS, 63% of BOD, 61% of COD, 21% of TN, and 32% of TP, respectively.

On the Surface Moisture Availability Parameters to Estimate the Surface Evaporation (증발량 추정을 위한 지표면 가용 수분 계수)

  • 황병화;황수진
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.427-435
    • /
    • 1995
  • In order to discuss the differences among the SMP(Surface Moisture Availability Parameter), by previous researchers on the basis of their own theoretical and empirical background, we assessed the SMP according to the soil types and volumetric soil water contents. The results are as follows. There are differences among all the five SMAPs. There's a tendency that the larger grain size, the higher value of parameters. And they divided into two groups for their value: one group has parameters with exponential function and the other with cosine and linear function. The maximum difference between the two groups appears when the volumetric soil water contents are 0.07m3m-3 for sand, 0.l1m3m-3 for loam, 0.12 for clay, and 0.13m3m-3 for silt loam. So, these differences must be considered when we estimate the surface evaporation rate. From field data, the paddy field soil around Junam reservoir is classified as a silt has high wetness, 0.56. So, the parameter obtained from the field measurement is much higher than that of Clapp and Hornberger(1978)'s Table. This study treated the SMP for a certain point of time in winter season. But if we measured the soil water contents continuously, we could obtain better time-dependent parameter. Key words : SMAP(Surface Moisture Availability Parameter), Paddy field, Volumetric soil water content, Evaporation, Capillary potential.

  • PDF

Nonlinear Regression on Cold Tolerance Data for Brassica Napus

  • Yang, Woohyeong;Choi, Myeong Seok;Ahn, Sung Jin
    • Journal of the Korean Data Analysis Society
    • /
    • v.20 no.6
    • /
    • pp.2721-2731
    • /
    • 2018
  • This study purposes to derive the predictive model for the cold tolerance of Brassica napus, using the data collected in the Tree Breeding Lab of Gyeongsang National University during July and August of 2016. Three Brassica napus samples were treated at each of low temperatures from $4^{\circ}C$ to $-12^{\circ}C$ by decrement of $4^{\circ}C$, step by step, and electrolyte leakage levels were measured at each stage. Electrolyte leakages were observed tangibly from $-4^{\circ}C$. We tried to fit the six nonlinear regression models to the electrolyte leakage data of Brassica napus: 3-parameter logistic model, baseline logistic model, 4-parameter logistic model, (4-1)-parameter logistic model, 3-parameter Gompertz model, and (3-1)-parameter Gompertz model. The baseline levels of the electrolyte leakage estimated by these models were 4.81%, 4.07%, 4.19%, 4.07%, 4.55%, and 0%, respectively. The estimated median lethal temperature, LT50, were $-5.87^{\circ}C$, $-6.31^{\circ}C$, $-6.05^{\circ}C$, $-6.35^{\circ}C$, $-4.98^{\circ}C$, and $-5.15^{\circ}C$, respectively. We compared and discussed the measures of goodness of fit to select the appropriate nonlinear regression model.

Base Flow Estimation in Uppermost Nakdong River Watersheds Using Chemical Hydrological Curve Separation Technique (화학적 수문곡선 분리기법을 이용한 낙동강 최상류 유역 기저유출량 산정)

  • Kim, Ryoungeun;Lee, Okjeong;Choi, Jeonghyeon;Won, Jeongeun;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.489-499
    • /
    • 2020
  • Effective science-based management of the basin water resources requires an understanding of the characteristics of the streams, such as the baseflow discharge. In this study, the base flow was estimated in the two watersheds with the least artificial factors among the Nakdong River watersheds, as determined using the chemical hydrograph separation technique. The 16-year (2004-2019) discontinuous observed stream flow and electrical conductivity data in the Total Maximum Daily Load (TMDL) monitoring network were extended to continuous daily data using the TANK model and the 7-parameter log-linear model combined with the minimum variance unbiased estimator. The annual base flows at the upper Namgang Dam basin and the upper Nakdong River basin were both analyzed to be about 56% of the total annual flow. The monthly base flow ratio showed a high monthly deviation, as it was found to be higher than 0.9 in the dry season and about 0.46 in the rainy season. This is in line with the prevailing common sense notion that in winter, most of the stream flow is base flow, due to the characteristics of the dry season winter in Korea. It is expected that the chemical-based hydrological separation technique involving TANK and the 7-parameter log-linear models used in this study can help quantify the base flow required for systematic watershed water environment management.