• Title/Summary/Keyword: environmental cleaner

Search Result 146, Processing Time 0.025 seconds

A Study on the Aerobic Digestion Treatment of Night soil (분뇨의 호기성 소화처리에 관한 고찰)

  • 육찬남
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.77-82
    • /
    • 1996
  • Environmental issues are getting imrx>rtant and the polluted environment is now c considered as one of the serious social problems which we have to face. As a result, most people hate an night soil-treating establishment to be built near their village. This paper is intended to reveal the present situation of Sanitary Environment Bureau in Iksan City and its treatment of night soil. The conclusions are as follows 1. The mean quantity of treated night soil per day was approximately 126kl In 1995, and the treated quantity per month was largest in the months from May to August, but smallest in January and February. The quantity of the largest month doubled the one of the smallest, and it is considered to be because the microorganisms are more active in the warm season than in the cold season, being a a ble to process more night soil. 2. The after-treatment sewage water is regarded as being in an optimalcondition because the examination of the water discharged from the establishment revealed the result of BOD 16.67mg/l and SS 14.78mg/l in 1995. 3. The expense for treating human waste was ₩19,582 in Iksan Sanitary Environment Bureau and it was considerably lower than the average expense through the nation, i.e. ₩22,000-25,000. But the cost should be expanded for keeping outworn equipments from the old age. 4. It is desirable for the Bureau to open the establishment so that any adult or student can come into it and watch all the treating processes. It will help the citizens understand the need for the establishment in spite of its nasty and ugly impression. Other cities or countries have to follow this model and try to provide their citizens with a cleaner environment by investing more fund technology for it.

  • PDF

Comparing School Lunch Program Served at Dining Room with Program at Classroom for Sanitation and Contentment at One Middle School (중학교 학교급식의 식당과 교실 배식의 급식만족도와 위생상태 비교)

  • Song, Hyun-Jung;Moon, Hyun-Kyung
    • Korean Journal of Community Nutrition
    • /
    • v.15 no.3
    • /
    • pp.369-378
    • /
    • 2010
  • School lunch programs at middle schools have increased in quantity. However, the quality of them is in fact not enough to reach the satisfactory standard, especially in the aspect of environment of school meals. It is true that there seems to be little attention to the environment. In this study, degree of satisfaction about school lunch program was surveyed for students in one middle school. Focus of survey was sanitary condition about the dining room and classroom where they have lunch. First, in order to investigate the degree of satisfaction about their dining place, questionnaire was sent out to the students at one middle school in Seoul. Questionnaire was made with reference to previous research. Second, for the study on environmental sanitation, dropping bacteria (general bacteria) is measured in three parts of dining place (entrance, serving table, dining table). Petriplate film was exposed to the responsible places for 15 minutes and then cultivated at the temperature of $32^{\circ}C$ for 48 hours before counting the number of bacteria formed. For the statistical analysis, SPSS 12.0 was used. The results of the study show that students had more satisfaction in dining room service than in classroom service. Important factors for the meal program such as "taste of food", "amount of food per student", "state of keeping warm", "appearance of food", "diversity of menu", and "kindliness of feeding staff" had more points in dining room than in classroom. For the environmental and sanitary aspect, the result of dropping bacteria (general bacteria) in dining room and classroom showed that table (5.00) and fooddistribution corner (8.67) of dining room were cleaner than those of classroom (P < 0.05). Making a good environment for school feeding will have a positive effect on the improvement of satisfaction and sanitation of school feeding. There should be expansion of dining room service for the students.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

A Study on the Strategies for the Reduction of Port Pollution (환경의 환경오염 저감방안에 관한 연구)

  • Song, Gye-Eui;Han, Chul-Hwan
    • Journal of Korea Port Economic Association
    • /
    • v.23 no.1
    • /
    • pp.95-113
    • /
    • 2007
  • Recently, International institution such as IMO and major maritime countries have introduced various regulations and steps to reduce port pollution. However, recognition of environmental pollution from ports is not sufficient for Korean policy makers and port communities. The purpose of this paper is to examine solutions to port pollution problems and suggests some implications to Korean ports to become a green port. To this aim, necessity of regulation on environmental pollution from port operation; literature survey on port's environmental pollution; current conditions of international port pollution; various regulations and policies governing major ports are conducted in this paper. Our main findings are as follows; first, air pollution from ship can be reduced by providing electric power at docks while at berth, Second, in case of cargo-handling equipment, retire old equipment and switch to cleaner fuel such as low-sulfur fuel and diesel emulsions. Third, offering incentives for the installation of pollution controls and minimizing idling by enforcing idling limits or by installing idle shutoff controls can be recommended for reduction of air pollution of truck and rail at ports.

  • PDF

Study on Practical Evaluation for Sustainability in Textile and Fashion Companies (섬유·패션기업의 지속가능성 실천 평가 연구)

  • Syn, Hye-Young;Geum, Key-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.2
    • /
    • pp.137-146
    • /
    • 2014
  • The practice of sustainability is an important subject to integrate into the management, product planning, manufacturing by textile and fashion companies as well as consumption by end-users. This study shows an evaluation scale designed to assess the practical cases in order to suggest efficient and systematic methods to fulfill the practice of sustainability in textile and fashion companies. First, companies should practice environmental sustainability to use eco-friendly material and cleaner production, protect the environment, and save natural resources. Second, social sustainability is required to fulfill social responsibility and ethical needs. Third, companies should perform various innovative activities, transparency in management, fair competition and economic contribution in the local community in order to maintain economic sustainability to survive in industry. Finally, cultural sustainability should be fulfilled by textile and fashion companies as part of the intellectual-cultural industry in a way that increases the importance of ethnic and cultural diversity. Textile and fashion companies should fulfill four environmental, social, and economic cultural sustainable subjects in a balanced method to accomplish sustainability. The concerns and practices of environmental sustainability are comparatively highly rated due to the analysis of the evaluation scale. However, cultural sustainability (a need of the times) is poorly rated and needs more attention. Therefore, the evaluation scale can be used as a standard tool to fulfill the sustainability of companies and brands from the viewpoint of improving poor and insufficiently sustainable items as well as balancing sustainability management.

Undrained shear strength and microstructural characterization of treated soft soil with recycled materials

  • Al-Bared, Mohammed A.M.;Harahap, Indra S.H.;Marto, Aminaton;Abad, Seyed Vahid Alavi Nezhad Khalil;Ali, Montasir O.A.
    • Geomechanics and Engineering
    • /
    • v.18 no.4
    • /
    • pp.427-437
    • /
    • 2019
  • Waste materials are being produced in huge quantities globally, and the usual practice is to dump them into legal or illegal landfills. Recycled tiles (RT) are being used in soil stabilisation which is considered as sustainable solution to reduce the amount of waste and solve the geotechnical problems. Although the stabilisation of soil using RT improved the soil properties, it could not achieve the standard values required for construction. Thus, this study uses 20% RT together with low cement content (2%) to stabilise soft soil. Series of consolidated undrained triaxial compression tests were conducted on untreated and RT-cement treated samples. Each test was performed at 7, 14, and 28 days curing period and 50, 100, and 200 kPa confining pressures. The results revealed an improvement in the undrained shear strength parameters (cohesion and internal frication angle) of treated specimens compared to the untreated ones. The cohesion and friction angle of the treated samples were increased with the increase in curing time and confining pressure. The peak deviator stress of treated samples increases with the increment of either the effective confining pressures or the curing period. Microstructural and chemical tests were performed on both untreated and RT-cement treated samples, which included field emission scanning electron microscopic (FESEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and energy dispersive X-ray spectrometer (EDX). The results indicated the formation of cementation compounds such as calcium aluminium hydrate (C-A-H) within the treated samples. Consequently, the newly formed compounds were responsible for the improvement observed in the results of the triaxial tests. This research promotes the utilisation of RT to reduce the amount of cement used in soil stabilisation for cleaner planet and sustainable environment.

Lung Function of Grain Millers Exposed to Grain Dust and Diesel Exhaust in Two Food Markets in Ibadan Metropolis, Nigeria

  • Iyogun, Kemi;Lateef, Suraju A.;Ana, Godson R.E.E.
    • Safety and Health at Work
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2019
  • Background: Despite growing concern over occupational exposure to particulate matter (PM) such as grain dust and diesel exhaust, information about the exposure level and health implications among workers in small-scale milling enterprises in developing countries like Nigeria has not been adequately documented. The purpose of this study was to assess the level of exposure to grain dust and diesel exhaust and effect on lung function among grain millers in food markets in Ibadan metropolis, Nigeria. Methods: The study adopted descriptive cross-sectional design with a comparative approach. Sixteen grain milling shops each were randomly selected from two major food markets in Ibadan metropolis for indoor $PM_{10}$ and $PM_{2.5}$ monitoring. Seventy-two respondents each were proportionately selected from grain millers and shop owners for forced expiratory volume in one second and peak expiratory flow rate tests. Results: The $PM_{2.5}$ concentrations for both market locations ranged between 1,269.3 and $651.7{\mu}g/m^3$, while $PM_{10}$ concentrations were between 1,048.2 and $818.1{\mu}g/m^3$. The recorded concentrations exceeded the World Health Organization guideline limit of $50{\mu}g/m^3$ and $25{\mu}g/m^3$ for $PM_{2.5}$ and $PM_{10}$, respectively. As compared with control group (2.1 L), significantly lower forced expiratory volume in one second value (1.61 L) was observed among the exposed group (p < 0.05). Likewise, significantly lower peak expiratory flow rate value (186.7 L/min) was recorded among the exposed group than the control group (269.51 L/min) (p < 0.05). Conclusion: Exposure to grain dust and diesel exhaust accentuated respiratory disorders with declines in lung functions amongst grain millers. Improved milling practices and engaging cleaner milling facilities should be adopted to minimize exposure and related hazards.

Mixotrophic Cultivation of a Native Cyanobacterium, Pseudanabaena mucicola GO0704, to Produce Phycobiliprotein and Biodiesel

  • Kim, Shin Myung;Bae, Eun Hee;Kim, Jee Young;Kang, Jae-Shin;Choi, Yoon-E
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.10
    • /
    • pp.1325-1334
    • /
    • 2022
  • Global warming has accelerated in recent decades due to the continuous consumption of petroleum-based fuels. Cyanobacteria-derived biofuels are a promising carbon-neutral alternative to fossil fuels that may help achieve a cleaner environment. Here, we propose an effective strategy based on the large-scale cultivation of a newly isolated cyanobacterial strain to produce phycobiliprotein and biodiesel, thus demonstrating the potential commercial applicability of the isolated microalgal strain. A native cyanobacterium was isolated from Goryeong, Korea, and identified as Pseudanabaena mucicola GO0704 through 16s RNA analysis. The potential exploitation of P. mucicola GO0704 was explored by analyzing several parameters for mixotrophic culture, and optimal growth was achieved through the addition of sodium acetate (1 g/l) to the BG-11 medium. Next, the cultures were scaled up to a stirred-tank bioreactor in mixotrophic conditions to maximize the productivity of biomass and metabolites. The biomass, phycobiliprotein, and fatty acids concentrations in sodium acetate-treated cells were enhanced, and the highest biodiesel productivity (8.1 mg/l/d) was achieved at 96 h. Finally, the properties of the fuel derived from P. mucicola GO0704 were estimated with converted biodiesels according to the composition of fatty acids. Most of the characteristics of the final product, except for the cloud point, were compliant with international biodiesel standards [ASTM 6761 (US) and EN 14214 (Europe)].

Evaluation of Indoor Mold Exposure Level in dwelling Using DNA-Based Mold Assessment Method (DNA 기반 곰팡이 평가기법을 활용한 주택의 실내 곰팡이 노출수준 평가)

  • Hwang, Eun-Seol;Seo, Sung Chul;Lee, Ju-Yeong;Ryu, Jung-min;Kwon, Myung-Hee;Chung, Hyen-Mi;Cho, Yong-Min;Lee, Jung-Sub
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.4
    • /
    • pp.382-392
    • /
    • 2018
  • Objective: Allergic diseases such as asthma due to fungal exposure in houses have increased, and proper management is urgent. Mold can grow in the air, floor, walls, and other areas according to environmental conditions, and there are many limitations to the conventional methodology for examining fungal exposure. For this reason, the degree of fungal contamination is being evaluated by ERMI (Environmental Relative Moldiness Index), a quantitative analysis method proposed by the EPA. In this study, we compared ERMI values between water-damaged dwellings and non-damaged ones to evaluate the effectiveness of Korean ERMI values. We also explored the association of ERMI values with the level of airborne mold and characteristics of dwellings. Methods: Floor dust was collected after installing a Dustream collector on the suction port of a vacuum cleaner. The collected samples were filtered to remove only 5 mg of dust, and DNA was extracted using the FastDNA SPIN KIT protocol. Results: The ERMI values were found to be 19.6 (-6.9-58.8) for flooded houses, 7.5 (-29.2-48.3) for leaks/condensation, and 0.8 (-29.2-37.9) for non-damaged dwellings. The airborne concentration of mold for flooded, leakage or condensed, and non-damaged houses were $684CFU/m^3$, $566CFU/m^3$, and $378CFU/m^3$, respectively. The correlation between ERMI values and the levels of airborne mold was low (R = 0.038), but a weakly significant association of the ERMI values with the concentration of particulate matter ($PM_{10}$) was observed as well(R=0.231,P<0.05). Conclusions: Our findings show that the reference value using ERMI can be used to distinguish water-damaged and non-damaged dwellings. It is believed that ERMI values could be a promising tool for assessing long-term fungal exposure in dwellings.

The effects of a newsletter on bedding control on house dust mite allergen concentrations in childcare centers in Korea

  • Kim, Jeonghoon;Jeong, Kyoung Yong;Kwon, Ho-Jang;Yang, Heasuk;Yum, Hye Yung;Lee, Seon Ah;Kim, Chae-Bong;Kim, Hyunjung;Lim, Wan Ryung;Hong, Soyoung;Kim, Kyoosang
    • Environmental Analysis Health and Toxicology
    • /
    • v.30
    • /
    • pp.8.1-8.8
    • /
    • 2015
  • Objectives Bedding in childcare centers (CCCs) can hold house dust mite (HDM) allergens. This study examined whether HDM allergen levels can be reduced through the distribution of an educational newsletter on bedding control to parents of CCC children in Korea. Methods All 38 CCCs were measured for Der 1 (sum of Der f 1 and Der p 1) concentrations on classroom floors and bedding before the intervention. Educational newsletters on children's bedding control were sent to 21 CCCs by mail, and teachers were asked to distribute the newsletters to the parents of the children (intervention group). The remaining 17 CCCs were not sent newsletters (control group). The measurement of Der 1 concentrations in 38 CCCs was repeated after the intervention. Dust samples were collected with a vacuum cleaner and analyzed using enzyme-linked immunosorbent assay methods. Results The Der 1 concentrations on the bedding were significantly higher than those on the floors in 38 CCCs at baseline (p < 0.05). Although changes of the Der 1 concentrations for the control group (n=17) were not significant, Der 1 concentrations for the intervention group (n=21) decreased significantly from 2077.9 ng/g dust to 963.5 ng/g dust on the floors and from 3683.9 ng/g dust to 610.4 ng/g dust on bedding (p < 0.05). Conclusions The distribution of educational newsletters on bedding control to parents may be an effective means of controlling HDMs in CCCs.