• Title/Summary/Keyword: environment units

Search Result 998, Processing Time 0.024 seconds

Evaluation on Noise Level of One-Room Type Multi-Family Housing Around Campus (대학주변 원룸형 다가구주택의 소음측정평가)

  • Choi, Yoon-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.95-100
    • /
    • 2003
  • The purpose of this study is to evaluate the noise environment of one-room type multi-family housing around the campus. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the 26th${\sim}$28th of November 2002. The results are as follows. 1) Outdoor noise levels of 6 subject buildings were distributed 52.8${\sim}$65.3dB(A) and were inappropriate to the standard for environmental noise, 55dB(A). 2) Indoor noise level of 6 subject house units were measured 27.5${\sim}$63.5dB(A). These values were higher than the indoor noise standard (40dB(A)) except subject house D(average 37.6dB(A)). 3) It was found that the differences of indoor noise levels between subject house units were caused by resident's living factor, characteristics of window, and existence of balcony.

  • PDF

Development of Guidelines for Indoor Environment in Apartment Remodeling Projects (아파트 리모델링의 실내환경 계획지침 개발)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The final aim of this study was to propose guidelines for the indoor environment of apartment remodeling projects. The first task of this study was to understand the major elements and the actual condition of the remodeling for apartment unit by carrying out in-depth interviews on residents and specialists. The open-access interviews were conducted with interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment units. The second task was to evaluate the actual condition of the indoor environment and to analyze the main factors that affect the indoor environment in remodeled apartment units. Field measurements were carried out in twenty apartment units occupied after remodeling, recording indoor environment elements (indoor temperature, globe temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, illumination, and equivalent noise level). Moreover, resident interviews and researcher observations were carried out to determine the contents of the remodeled unit and to investigate the architectural and living factors(like ventilation characteristics, etc.) related to the indoor environment. The results are as follows. The remodeling elements generally included the changing of lighting fixtures and finishing materials in all the spaces, the integration of the balcony into the children's room, the installation of furniture in the kitchen and the entrance, the changing storage furnitures and equipments in the bathroom. The average levels of each unit of relative humidity, $CO_2$, TVOC, HCHO, equivalent noise level, and illumination were proved to be on the whole in inadequate condition. The factors that affect these indoor elements were classified as remodeling factors (remodeling amounts, extent balcony integration, and lighting fixture exchange), ventilation characteristics, and living factors. According to these results, this research proposed the guidelines for the indoor environment in apartment remodeling projects.

Trend Changes of Spatial Configuration in Housing Units of Korean Apartments in the 2000s (2000년대 한국 아파트 단위세대의 공간구성 동향 변화)

  • Park, Joon Young;Jeong, Sang Kyu;Cheong, So Yi;Park, Woo Jang
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.21-27
    • /
    • 2012
  • This study aims at finding the trend changes of spatial configuration in housing units of Korean apartments in the 2000s. Among the housing units in the apartments built by large construction companies, we have selected ones with small and regular sizes, $59m^2$ and $84m^2$ respectively, and investigated the number of bays, the location of wet zone and the spatial flexibility in the housing units selected for analysis. In conclusion, the number of bays in the housing unit has gradually increased, after allowing for the structural change of the balcony in the legal. It is estimated that the trend has came from the intent to increase the numbers of the externally exposed surfaces of the balcony, ensure a good view, lighting, ventilation and spatial flexibility. The location of wet zone, water-needed space such as a bathroom or a kitchen, has changed in the direction to facilitate the expansion and modification of space. Variable range of space has gradually expanded by using the balcony and wet zone as much as possible. In order to configure more effectively spaces in housing environments, the future study should be implemented to develop tools for realizing sustainable housing environment at the levels of not only the housing unit. but also the entire building, housing site, and city.

A Study on Estimation of Construction Wastes Units in Urban Development (도시개발지구내 건설폐기물 발생원단위 특성연구)

  • Kim, Sang-Keun;Chung, Ha-Ik;Kwon, Ki-Bum;Yu, Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1452-1455
    • /
    • 2008
  • In order to establish active and effective recycling plans on construction wastes, the study seeks to built unit generation data per construction waste types on each sector, prepare units data on urban construction waste generation and serve as meaningful data on the establishment of policies on construction waste recycling targeting urban regions. The significance of the study is on the establishment of construction waste recycling plan prior to generation, not as complementary measures on construction waste generated.

  • PDF

Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the Top Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Opened - (공동주택의 하절기 자연환기 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석)

  • Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature, globe temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample units on the condition that all the openings of the units are opened. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained three brief results as follows. Indoor air temperature difference between the two sample units shifts a day. Indoor air temperature at the top floor unit is $0{\sim}1.8^{\circ}C$ higher than that of the middle floor unit from 12:00 p.m. to 12:00 a.m. and $0{\sim}2.8^{\circ}C$ lower from 12:00 a.m. to 12:00 p.m. The evaluation of the indoor thermal comfort index and the globe temperature shows similar results as the indoor air temperature measuring. Results of this experiment verified the actual existence of indoor air temperature difference between the top floor unit and the middle one and this difference comes from the heat storage of the roof.

Study of the Propagation Model considering Refractive Channel Environment between Korea and Japan (한일간 대기굴절 채널환경을 고려한 전파모델 연구)

  • Lee, Kyung-Ryang;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.1
    • /
    • pp.49-54
    • /
    • 2013
  • Japan and South Korea since 2004 until now for the broadcast channel interference, by measuring the ongoing conflict are expected to prepare for the future, but Korea's preparation are not enough. In this study, it is pointed that cause of the interference through channel environmental analysis, and effective application of propagation prediction model was carried out between neighboring countries. Between Korea and Japan, radio duct occurs on hold due to changes in the refractive gradient, and comfirmed occurrence of broadcasts interference. The results are presented that 1% time variable, -91.80 [N-units/km], 10% time variable, -43.92 [N-units/km], 50% time variable, -586.19 [N-units/km], for effective refractive gradient. Proposed refractive gradient could contribute to actual radio propagation prediction.

Analysis on Living Factor and Actual State of Indoor Thermal Environment in Apartment Units during Winter (아파트의 겨울철 실내온열환경 실태와 생활요인 분석)

  • Choi, Yoon-Jung;Jeong, Youn-Hong
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.97-105
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor thermal environment in apartment units and to analyze the relationship between the living factors and indoor thermal elements. The field surveys consisted of measurements of physical elements and observations of living factors. In addition, the residents of 20 apartment units were interviewed to survey their subjective response. Field surveys were carried out from January to March 2007. Measuring elements were air temperature, globe temperature, and relative humidity. The results showed that the average of indoor temperature for the houses was $21.2{\sim}27.2^{\circ}C$, while 4 houses exceeded the comfort zone. The average of globe temperature for the houses was $21.3{\sim}27.5^{\circ}C$, while 6 houses exceeded the comfort zone. The mean relative humidity was $19.5{\sim}58.8%$, which is a relatively dry condition. The residents' average clothing value was $0.39{\sim}0.89$ clo(average 0.68 clo). The average thermal sensation vote on each room was $4.2{\sim}4.8$, which is 'neutral' to 'slightly warm'. Living factors had significant effect on indoor temperature in regression analysis were ventilation time(outdoor air exchange), opening time of door through balcony, and gas cooker use time.

Factors Influencing Developmental Care Performance among Neonatal Intensive Care Units Nurses (신생아집중치료실 간호사의 발달지지간호 수행 영향요인)

  • Hong, Hyemi;Son, Hyun-Mi
    • Child Health Nursing Research
    • /
    • v.26 no.2
    • /
    • pp.131-139
    • /
    • 2020
  • Purpose: This study was conducted to identify factors related to developmental care performance among neonatal intensive care units (NICU) nurses. Methods: The participants were 139 nurses who had provided care to premature infants for more than 6 months and were recruited from the NICU of 8 hospitals. Data were collected from September 1 to December 1, 2017 through questionnaires that encompassed developmental care performance, developmental care perceptions, and the nursing work environment. Results: More than half (51.8%) of the participants responded that they had never received developmental care education, and for 89.6% of those who had received developmental care education, it was a one-time event. The average developmental care performance of NICU nurses was 0.81, with a range of 0.5~1 point. Multiple regression analysis, demonstrated that the nursing work environment (β=.27, p=.001) and developmental care perceptions (β=.23, p=.004) influenced developmental care performance, with a total explanatory power of 14%. Conclusion: Based on these results, developmental care education for the NICU nurses must be provided systematically. In addition, strategies to improve nurses' perceptions of developmental care and to provide appropriate support for the nursing work environment can promote developmental care performance.

Noise Levels in Intensive Care Units and Patient's Perception (중환자실 소음도와 소음에 대한 환자의 인지)

  • Kim, Min Young;Park, Ui-Jun
    • Journal of Korean Critical Care Nursing
    • /
    • v.8 no.1
    • /
    • pp.41-49
    • /
    • 2015
  • Purpose: The purpose of this study was to measure the noise levels in intensive care units (ICUs) and to analyze the causes of the noise and patient perceptions of the noise. Methods: Noise levels were recorded in adult ICUs for 24 h over a week from the patients' bedside with a sound level meter. Noise sources were categorized into three groups: medical equipment, health care providers, and the environment. Noises from the environment were recorded in an empty ICUs side room. Perceptions of the noise of 125 patients admitted to the ICUs were recorded using a questionnaire. Results: The mean level of noise in the ICUs was 58.5 dBA (range: 34.2-80.2 dBA). The causes of noise higher than 70 dBA were nebulizers and infusion/syringe pumps among medical equipment, and drawer slamming, phone ringing, and stripping packages of medical fluids among environmental noises. According to the questionnaire, 64.0% of the patients responded that the ICUs were noisy and that they suffered from sleep disturbance because of the noise. Conclusion: Noise is considerably high in ICUs and is an annoying factor for the patients. Most noise sources are adjustable, and we should try to reduce noise whenever possible to make the ICUs environment more pleasant.

Analysis on Living Factor and Present Condition of Indoor Thermal Environment in Apartment Units during Winter (아파트의 겨울철 실내온열환경 실태와 생활요인 분석)

  • Choi, Yoon-Jung;Jeong, Youn-Hong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.281-284
    • /
    • 2008
  • The purposes of this study were to make clear the present condition of indoor thermal environment in apartment units and to analyze the relation of the living factors with indoor thermal elements. The field surveys consisted of measurements on physical elements and observations on living factors and interview on resident's subjective responses were carried out in 20 apartment units. The field surveys were carried out during the $January{\sim}March$ 2007. Measuring elements were air temperature, globe temperature, and relative humidity. As results, the averages of indoor temperature each houses were $21.2{\sim}27.2^{\circ}C$, the number of houses exceed the comfort zone were 4. The averages of globe temperature each houses were $21.3{\sim}27.5^{\circ}C$, 6 houses exceeded the comfort zone. The means of relative humidity were $19.5{\sim}58.8%$, relatively dry condition. The clothing value of residents were $0.39{\sim}0.89$ clo(average 0.68 clo). The average of thermal sensation ratings each room were $4.2{\sim}4.8$, 'neutral'$\sim$'slightly warm'. The results of regression analysis on relations of living factors with the thermal elements are as follow; ventilation time(outdoor air exchange), door opening time with balcony, and gas cooker use time had significant effect on indoor temperature.

  • PDF