• Title/Summary/Keyword: entrance zone

Search Result 81, Processing Time 0.024 seconds

Improvement of the Ventilation Equipment in a Waste Bunker For a Municipal Waste Incinerator (자원회수시설용 폐기물 벙커의 환기설비설계 개선에 관한 연구)

  • Lee, Tae-Gu;Moon, Jung-Hwan;Hur, Jin-Huek;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.51-59
    • /
    • 2007
  • The waste bunker usually consists of waste entrance zone and waste pit. In this paper, the distributions of air flow, $NH_3$ concentration and $H_2S$ concentration in a waste bunker were investigated to prevent an odor generated in a waste pit from dispersing to the waste entrance zone by numerical method. Four cases were considered such that 1) the waste incinerators is operated, 2) the waste incinerators is stopped, 3) the waste incinerator is operated and the direction of a supply diffuser is $45^{\circ}$ upward, 4) the waste incinerator is stopped and the direction of a supply diffuser is $45^{\circ}$ upward. In case of 1), the fresh air from the waste entrance zone is exhausted smoothly to the main exhaust grill of the waste pit. It means that an odor dispersion to the waste entrance zone will not occur. However in case of 2), the induction of fresh air is so small and the supply air with an odor in waste pit can flow to the waste entrance zone. Therefore, an odor will be dispersed to the waste entrance zone. This paper shows the solution that the supply diffuser with the direction of $45^{\circ}$ upward is chosen. As a result in case of 3) and 4), an odor dispersion to the waste entrance zone does not occurred and on odor is exhausted smoothly to the auxiliary exhaust grill.

A simulation analysis on the effect of counterbeam lighting for the tunnel entrance zones (터널 입구부 카운터빔조명의 효과에 대한 시뮬레이션 연구)

  • Lee, Young-Q;Lee, Seung-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.4
    • /
    • pp.377-385
    • /
    • 2007
  • Drivers passing through a tunnel fare some difficulties caused by the visual differences between outside and inside of the tunnel. The blackhole phenomenon at a tunnel entrance lone severely decreases the driver's visibility during the daytime. A counterbeam lighting is generally recommended for the prevention of it. This paper simulates an entrance zone with a blackhole phenomenon to verify the effect of counterbeam lighting. Even though the tunnel lighting is important, It Is not easy to consider many lighting alternatives at the stage of tunnel design due to the complexity of tunnel renditions. This paper is expected to contribute improving the visibility in tunnels, especially at the entrance zone.

  • PDF

Tunnel Lighting Control System using Fuzzy Reasoning (퍼지추론을 적용한 터널 조명제어시스템)

  • Lee, Jung-Eun;Choi, Hong-Kyoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1140-1145
    • /
    • 2014
  • Tunnel lighting is composed of entrance zone, interior zone and exit zone by KS C 3703. We have to consider adaptation at entrance zone and exit zone lighting to prevent deteriorate visibility like black hole and white hole phenomenon. So External luminance, vehicle velocity and traffic volume should be considered in threshold zone lighting and vehicle speed and traffic volume should be considered in interior zone lighting. But existing tunnel lighting system is not good at visibility and economic because that is only controled by external luminance. So in this paper, We improve visibility and economic of tunnel lighting system using fuzzy reasoning according to external luminance, vehicle velocity, traffic volume.

A Study on the Circulation System of Elementary School Complex (초등학교 복합시설 동선계획에 관한 연구)

  • Lee, Jin-Kyoung;Kim, Chan-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.6
    • /
    • pp.12-21
    • /
    • 2008
  • The purpose of this study was to research on relationship between the circulation system of students and resident users in elementary school complex. 4 elementary schools in Seoul were chosen for this study. The method of this study is a plan analysis, an on-the-spot survey, and user behavior observation. The circulation system of students and resident users at school zone(outside) and Community school were observed. The following is the main results of this study. First, circulation systems are mixed between public zone and student zone in Community school. Therefore these zones shall be planed separated. Second, resident users tend to go directly to the facilities gathered together. Therefore main entrance has to be located closely to the facilities gathered together. In accordance with this results, both the main entrance of Community school and the students facilities have to be considered when planing the circulation system in school from now on.

A Study on the Laboratory Function and Spatial Organization for Laboratory Medicine - Focused on the Tertiary Level General Hospitals having more than 1000 Beds (진단검사의학과의 검사기능과 공간구성에 관한 연구 - 1000병상급 종합병원을 중심으로)

  • Choi, Changdae;Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.37-53
    • /
    • 2017
  • Purpose: As the structure of the disease has been changed and the infectious disease has been increased, the demand for diagnostic examination has been increasing. So, the department of laboratory medicine in hospital has playing the important role accounting for about nineteen percent of total medical expenses in korea. This study is to investigate the laboratory function and spatial composition of the department and figure out the space area and space organization. Methods: Explore the literature review to identify the laboratory function. Limit to five cases of tertiary level general hospital having about a thousand bed and analyze the space layout and floor area to confirm the spatial composition. Classify the exam function and check the spatial composition and spatial organization. Results: This study allows 5 conclusions to be summarized. Laboratory medicine divided into nine part in regulation, but in space allocated into core lab, emergency lab and six part lab. Total laboratory area is $2,036m^2$ in average, and is composited with 60% for lab, 17% for office and 20% for public. Lab area per a bed presents $1.88m^2$. Microbiolgy and molecular lab area are getting large. Laboratory space organized into the four zone, like an entrance zone, core zone, rear zone and peripheral zone. Emergency and transfusion lab are allocated in entrance zone, hematology chemistry and immunology in core lab, microbiology and molecular lab in rear, support offices in peripheral zone. The most important point was to check the spatial composition of the Laboratory Medicine according to the inspection function. Implications: This study can be used as a useful data in planning and designing a Laboratory Medicine Department.

A Study on the Facilities Layout of Lower Floor and Space Characteristics Through Analysis of Newly Established Schools in Chungbuk since 2010 (충북의 2010년 이후 신설된 학교 분석을 통한 저층부 배치 시설 및 공간 특성 연구)

  • Kang, Hye-Jin;Jung, Jin-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.22 no.2
    • /
    • pp.3-13
    • /
    • 2015
  • The policy of the Ministry of education through the social awareness and issues are being changed. Accordingly, in response to the school building which also has to be changed. This study is Low-floor(1~2 floor) for high accessibility, important management and a lot of locomotion. This study is analysis by floor of newly established schools in Chungbuk. Facility and space on the possible low-floor situated are classified administrative zone, health zone, student support + local exchange zone, STEAM(creativity, personality) supporting zone. The administrative area includes administration office, principal's office and board rooms. The administrative zone is located against schoolyard. Because it is possible visual control of schoolyard. also it controls visitor access so it is placed near main entrance. Health zone is located near a special class, counseling center and wee class for emergency situation. and is located near schoolyard for visual control. Student support + local exchange area includes library and computer lab, audio-visual room, auditorium or gymnasium. It put more emphasis resident welfare, culture and education. So it opens for local residents. It is located center of few stories or near entrance. STEAM(creativity, personality) supports science lab, art room, family room. It is possible such a theory class, experience class and indoor and outdoor class. It is located few floors. This study is used as a reference for school building projects planing.

Safety Evaluation of the Lighting at the Entrance of a Very Long Road Tunnel: A Case Study in Ilam

  • Mehri, Ahmad;Hajizadeh, Roohalah;Dehghan, Somayeh Farhang;Nassiri, Parvin;Jafari, Sayed Mohammad;Taheri, Fereshteh;Zakerian, Seyed Abolfazl
    • Safety and Health at Work
    • /
    • v.8 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Background: At the entrance of a tunnel, reflection of sunlight from the surrounding environment and a lack of adequate lighting usually cause some vision problems. The purpose of this study was to perform a safety evaluation of lighting on a very long road in Ilam, Iran. Methods: The average luminance was measured using a luminance meter (model S3; Hagner, Solna, Sweden). A camera (model 108, 35-mm single-lens reflex; Yashica, Nagano, Japan) was used to take photographs of the safe stopping distance from the tunnel entrance. Equivalent luminance was determined according to the Holliday polar diagram. Results: Considering the average luminance at the tunnel entrance ($116.7cd/m^2$) and using Adrian's equation, the safe level of lighting at the entrance of the tunnel was determined to be 0.7. Conclusion: A comparison between the results of the safe levels of lighting at the entrance of the tunnel and the De Boer scale showed that the phenomenon of black holes is created at the tunnel entrance. This may lead to a misadaptation of the drivers' eyes to the change in luminance level at the entrance of the tunnel, thereby increasing the risk of road accidents in this zone.

Analysis of the Stability and Behavior of a Calcareous Rock Slope During Construction of a Tunnel Entrance (터널출입구 시공에 따른 석회암 사면의 안정성 및 거동 분석)

  • Song, Young-Suk;Yun, Jung-Mann
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.283-292
    • /
    • 2013
  • A calcareous rock slope failed during excavation of the slope for construction of a tunnel entrance. The slope is located at the construction site for widening highway in Yeongwol, Korea. Field surveys, laboratory tests, and numerical analyses were performed to determine the reason for the slope failure. The numerical analysis revealed that the safety factor of the slope before construction of the entrance was less than 1, and that this decreased after construction. After construction of the entrance, the sliding zone of the slope increased and slope stability decreased because the shear strain and plastic zone in the slope over the tunnel entrance showed an increase relative to the lower part of the slope. To enhance the stability of the slope for construction of the tunnel entrance, countermeasures such as rock bolts, rock anchors, and FRP (Fiber glass Reinforced Plastic) grouting were adopted in light of the field conditions. Serial field monitoring performed to confirm the reinforcing effects of the adopted countermeasures revealed a small amount of horizontal deformation of the slope soils, most of the elastic deformation that can regain its former value. In addition, the axial forces of the rock bolt and anchor were more strongly affected by slope excavation during construction of the tunnel entrance than by tunnel excavation or the rainy season, and the axial forces tended to converge after excavation of the tunnel. Therefore, we can confirm that the slope is currently safe.

Application Techniques of 2D-Resistivity Structure for Estimation of Inferred Fracture Zone in Weathered Slope (풍화사면에서의 추정파쇄대 평가를 위한 2차원 전기비저항 구조도 적용 기법)

  • Kim, Jae-Hong;Park, Chal-Sook;Lee, Hyun-Jae;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.323-330
    • /
    • 2009
  • Electrical resistivity survey is applied for estimation of inferred fault and fractured zone in civil engineering and environment field. While 15 m diameter and 3 lines tunnels are excavated. It is recognized that core stone and fractured zone is existed in the weathered slope of the entrance to a tunnel. To make confirmation geological characteristics, dipole-dipole electric resistivity survey was carried out in weathered slope of the entrance to a tunnel. Core stone distribution and fracture zone characteristics are estimated by reverse analysis and 2D-resistivity structure using FDM.

A Study on the Guideline of Spatial Composition and Circulation in Triages and Entrances Area in Emergency Departments for Efficient Infection Control (응급부 진입구역과 환자분류구역의 감염관리를 위한 환자동선과 공간구성 계획에 대한 연구)

  • Kang, Jeeeun;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.1
    • /
    • pp.41-49
    • /
    • 2019
  • Purpose: After Mers breakout in 2015, major hospital in Korea have been renovated the emergency department to make a separate infection control zone for high-risk patient with potential infection and to improve a triage area and an entrance area for efficient patient evaluation. However, there are no specific design standards to reinforce infection control for patients and staffs safety. Therefore, it is important to establish of initial design factors in the triage and entrance area as a guideline. Methods: 5 cases which had been recently renovated are selected to analyze patient circulation and spatial composition in a triage area and an entrance area. The partial floor plans of each case are represented as bubble diagrams to help understanding of different patient circulation flows. Based on this analysis, significant design factors which should be considered in planning stage for infection control have been extracted. Results: 13 design factors are established. Using these design factors, patient circulation diagram is generated to provide an optimized suggestion for efficient infection control. Implications: This suggestion provides basic databases to start to establish design guideline in the triage area and the entrance area to minimize infection spreading in the emergency department.