• Title/Summary/Keyword: enhanced receiver tube

Search Result 2, Processing Time 0.016 seconds

Thermal performance investigation of enhanced receiver tube for concentrated solar collector

  • Mohammed Al-Harrasi;Afzal Husain;M. Zunaid
    • Advances in Energy Research
    • /
    • v.8 no.3
    • /
    • pp.137-144
    • /
    • 2022
  • This study presents an experimental investigation of conventional and enhanced receiver tube performance for the application of a concentrated parabolic trough collector (CPC). The CPC system is fabricated and tested for the conventional and enhanced receiver tubes. The experiments were performed on both tubes for the change of flow rates. The temperature rise of the tube surface, as well as working fluid, were monitored for varying flow rates. The results were compared and discussed in view of enhanced CPC system performance. The results exhibited that the temperature rise of the working fluid passing through the tube was more in the case of the enhanced tube compared to the conventional receiver tube under the same flow rates.

A Study on Dose Reduction in Infant Skull Radiography (유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구)

  • Ahn, Byoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.387-392
    • /
    • 2017
  • When an infant has visited a hospital due to skull fracture, the rupture of a blood vessel, or skin wounds on the head resulted from an incident, accident, traffic accident, or disease, he/she becomes to undergo anterior/posterior and lateral skull imaging, which is a head test at the department of radiology. In the head test, if the adult skull imaging grid is applied to the imaging, the secondary radiation will be removed to enhance the contrast of the image. However, among the radiation exposure conditions, the tube voltage should be enhanced by 8~10 kVp leading to an increase in the patient exposure. The present study was conducted under assumption that if the same images can be obtained from infant skull imaging without using the skull imaging grid, the exposure dose will be reduced and the artifacts due to grid cut off can be prevented. The researcher measured the radiation dosage using a radiation meter and conducted the subjective evaluation (ROC, receiver operating characteristic) among medical image evaluation methods. Based on the results, when the images were taken without using the grid, the exposure dose was reduced by 0.019 mGy in the anterior/posterior imaging and by 0.02 mGy in the lateral imaging and the image evaluation score was higher by 4 points. In conclusion, if the images of the skulls of infants that visited the hospital are taken with out using the grid, the exposure dose can be reduced, the image artifacts due to grid cut off can be prevented, and the lifespan of the X-ray tube will be extended.