• Title/Summary/Keyword: engineering technology

Search Result 92,854, Processing Time 0.125 seconds

Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

A Study on the Calculation of Nonpoint Source EMCs using SWMM in Transportation Area (강우유출모형을 활용한 교통지역 비점오염원 EMCs 산정 연구)

  • Kwon, Heongak;Im, Toehyo;Lee, Jaewoon;Jeong, Hyungi;Lee, Chunsik;Cheon, Seuk
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.193-202
    • /
    • 2015
  • In this study, a long term monitering of nonpoint source pollution runoff is conducted at the area of transportation related and EMCs(Event Mean Concentrations) in terms of water quality items, such as BOD, $COD_{Mn}$, SS, T-N and T-P are determined for each not only runoff event and but also observation site. On the other hands, SWMM(Storm Water Management Model) model is constructed using the data collected in the transportation areas selected. Model calibration and verification of SWMM is carried out based on the data collected. And simulated EMCs was compared with observed EMCs by monitoring and prior studies. SWMM applicability estimation was Using the compared result. The results of simulation showed that BOD 5.787 ~ 14.475 mg/L, $COD_{Mn}$ 12.946 ~ 59.611 mg/L, SS 13.742 ~ 46.208 mg/L, T-N 2.037 ~ 5.213 mg/L, T-P 0.117 ~ 0.415 mg/L. And a differential between simulated EMCs and observed EMCs is too low so comparing result show high fit(BOD 4.27 %, $COD_{Mn}$ 4.87%, SS 2.31%, T-N 5.78%, T-P 14.45%). A results of compared with the prior studies, BOD and T-P are included range of prior studies, $COD_{Mn}$ and SS are lower than range of prior studies, T-N is higher than range of prior studies. Differential between simulated EMCs and prior studies EMCs was showing for survey seasonal and changing land-use, so from now on, EMCs of using the internal representatives value will be calculated by more monitoring toward various precipitation events.

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF

Changes in Soil Physical Properties of Peatmoss Containing Root Media as Influenced by Container Size and Packing Density (용기 크기와 충전밀도 차이에 따른 피트모스 혼합상토의 물리성 변화)

  • Park, Eun Young;Choi, Jong Myung;Lee, Dong Hoon
    • Horticultural Science & Technology
    • /
    • v.31 no.5
    • /
    • pp.558-564
    • /
    • 2013
  • The objective of this research was to secure the fundamental information in changes of soil physical properties as influenced by the compaction of root media during container filling. Three root media were formulated by blending peatmoss (PM) with expanded rice hull (PM + ERH, 8:2, v/v), carbonized rice hull (PM + CRH, 6:4) and ground and aged pine bark (PM + GAPB, 8:2). Based on the optimum bulk density, the amount of root media filled into 6.0, 7.5, 8.5, 10.5 and 12.5 cm were adjusted to 90, 100, 110, 120, and 130%, then the changes in total porosity (TP), container capacity (CC), and air-filled porosity (AFP) were measured. The TP decreased significantly as the packing amount of three root media were elevated in all sizes of container. The TP did not show significant differences among the root media in small sizes of containers, but showed significant differences when sizes of containers became larger. As packing amount of three root media were elevated, the CCs in all sizes of containers were decreased. The PM + CRH had the lowest CC among three root media in containers smaller than 8.5 cm, but had the highest CC in those larger than 10.5 cm. These results indicated that the decreases in CC were influenced by the sizes of containers as well as kinds of root media. The elevation of packing amount in three root media diminished significantly the AFP. The AFP in PM + GAPB medium was two times as high as those of PM + ERH or PM + CRH when equal packing densities were applied in all sizes of containers. As the container sizes became larger in three root media, the extents in decreasing of CC were distinct than those of AFP. Above results indicate that elevation in packing amount of three root media decreased significantly the TP, CC and AFP, but these were influenced differently by sizes of containers and kinds of root media. The results would be useful for expectation in the changes of physical properties in various sizes of containers filled with peatmoss based root media.

Dust Spatial Distribution and Emission of Tunnel Ventilated Windowless Broiler Building (터널환기 무창육계사의 분진크기별 분포와 배출농도에 관한 연구)

  • Choi, H.C.;Yeon, G.Y.;Spmg, J.I.;Kang, H.S.;Kwon, D.J.;Yoo, Y.H.;Yang, C.B.;Chun, S.S.;Kim, Y.K.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.115-122
    • /
    • 2006
  • This study investigated the spatial distribution of dust originating from tunnel-ventilated windowless broiler building measuring 12 m wide, 61 m long, with a side wall height of 3 m and a capacity of 16,982 birds. Dust concentrations in terms of total suspended particles (TSP), and particulate matter of sizes $10\;{\mu}m$(PM10), $2.5\;{\mu}m$(PM2.5), and $1\;{\mu}m(PM1)$ were measured at 30 minutes interval by using GRIMM Aerosol Monitor (GRIMM AEROSOL). The spatial distribution of dust showed the lower dust concentration in the inlet than in the outlet of the tunnel ventilation, and dust concentration decreasing as the dust size decreased, as follows: $317.9\;{\mu}g/m^3$ TSP; $74.7{\mu}m/m^3$ PM10; $9.7\;{\mu}g/m^3$ PM2.5; and $6.2\;{\mu}g/m^3$ PM1 in the inlet; and $2,678.5\;{\mu}g/m^3$ TSP; $555.5\;{\mu}g/m^3$ PM10; $33.3\;{\mu}g/m^3$ PM2.5; and $10.2\;{\mu}g/m^3$ PM1 in the outlet. The dust concentration emitted from the tunnel ventilated fan was $446.6\;{\mu}g/m^3$ TSP; $129.1\;{\mu}g/m^3$ PM10; $15.8\;{\mu}g/m^3$ PM2.5; and $6.1\;{\mu}g/m^3$ PM1 in the 3 meters from the fan and $25.1\;{\mu}g/m^3$ TSP; $8.8\;{\mu}g/m^3$ PM10; $5.6\;{\mu}g/m^3$ PM2.5; and $4.9\;{\mu}g/m^3$ PM1 in the 50 meters from the fan.

  • PDF

Growth of Red-leaf Lettuce and Changes in Soil Solution Chemical Properties of Coir-dust Containing Root Media Influenced by Application Rates of Pre-planting Fused-Superphosphate (코이어 더스트 혼합상토에 용과린의 시비수준에 의한 적축면 상추의 생장과 근권부 화학성 변화)

  • Kim, Chang Hyeon;Choi, Jong Myung;Lee, Dong Hoon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.658-667
    • /
    • 2015
  • This research was conducted to investigate the influence of various levels of fused superphosphate as pre-planting fertilizer on the growth of red-leaf lettuce and changes in the chemical properties of the soil solution in three root media, namely coir-dust plus expanded rice hull (8:2, v/v; CD+ERH), carbonized rice hull (6:4; CD+CRH), or ground and aged pine bark (8:2; CD+GAPB). The amounts of fused superphosphate (FSP) incorporated into the three root media during formulation were controlled from 0 to $6.0g{\cdot}L^{-1}$ in $1.5g{\cdot}L^{-1}$ increments. The root media containing fertilizers were packed into 300 mL plastic pots and seedlings of red-leaf lettuce at the 3rd leaf stage were transplanted. After transplanting, the crops were fed with a solution of neutral fertilizer ($100mg{\cdot}L^{-1}$). The growth of red-leaf lettuce was investigated 5 weeks after transplanting and soil solutions were extracted and analyzed every week for pH, EC, and concentrations of macro-nutrients. The elevation of application rates of FSP in the three root media resulted in better growth, and the crops grown in CD+ERH and CD+GRPB had greater fresh and dry weights than those in CD+CRH when compared among the treatments of equal amounts of FSP. The pH and $PO_4{^{-3}}$ concentrations in the soil solution of CD+CRH at 3 weeks after transplant were in the ranges of 4.0 to 4.8 and 20 to $100mg{\cdot}L^{-1}$, respectively. These were lower pH and higher $PO_4{^{-3}}$ concentrations than those in CD+ERH and CD+GAPB. The $K^+$ concentrations were higher in CD+CRH than those in the other two root media, and the elevation of FSP application rates resulted in higher $Ca^{+2}$, $Mg^{+2}$ and $SO_4{^{-2}}$ concentrations in soil solution of the three root media. The $NO_3$-N concentrations in soil solution rose continuously during crop cultivation, implying that the leaching percentage was elevated. The soil solution EC varied, showing the same tendencies as the $NO_3$-N concentrations. The above results indicated that the CD+ERH and CD+GRPB media performed better than CD+CRH, and optimum application rates of FSP in the three root media were 4.5 to $6.0g{\cdot}L^{-1}$ for pot cultivation of red-leaf lettuce.

Development of Pharmaceutical Dosage Forms with Biphasic Drug Release using Double-Melt Extrusion Technology (이중 고온용융 압출 성형된 이중 방출능을 가지는 제형의 개발)

  • Kim, Dong-Wook;Kang, Chin-Yang;Kang, Changmin;Park, Jun-Bom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.228-234
    • /
    • 2016
  • The aim of this study was to develop pharmaceutical dosage forms with a bi-phasic drug using a double extrusion approach. Hot melt extrusion was performed using a co-rotating twin-screw extruder. The. 1st melt extrusion was performed using polymer with a relatively higher Tg, such as HPMC and the 2nd melt extrudate was obtained using the 1st extrudate and polymers with a lower Tg, such as HPMC-AS and PEO. In addition, the formulation with all the content in the same proportion as the double extudate was produced using single extrusion for comparison. Physical characterization was performed on the formulations employing differential scanning calorimetry (DSC). In vitro release tests were studied using a USP Type-I apparatus at $37{\pm}0.5^{\circ}C$ and 100 rpm. The similarity factor (f2) was also used to check the difference statistically. The DSC results indicated that the crystallinity of ibuprofen was changed to an amorphous state after extrusion in both double and single melt extrusion. Double melt extrudate with ibuprofen showed the desired release in acidic media (pH 1.2) in the first two hours and basic (pH 6.8) during six hours. Double melt extrudate with glimepiride showed faster release in 60 min of over 80%, whereas the single extrudate with glimepiride showed retarded release due to the interaction with HPMC. The similarity factor(f2) value was 28.5, which demonstrates that there were different drug release behavior between the double and single extrusion. Consequently, the double melt extrudated formulation was robust and gave the desired drug release pattern.

A Study on Applicability of Stabilizing Pile to Foundation Soil of Slope with Various Strength Parameters (사면하부지반의 강도정수에 따른 억지말뚝 적용성 연구)

  • Lee, Seung-Hyun;Jang, In-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.331-337
    • /
    • 2016
  • Several foundation soil conditions below a homogeneous sand slope were assumed and slope stability analyses were conducted to determine the soil condition, in which a stabilizing pile can be used to increase the factor of safety against sliding. The assumed heights of the sand slope were 5m and 10m. For a 5m slope height, a stabilizing pile can be used in the foundation soil with a $15^{\circ}$ internal friction angle and a cohesion of 10kPa. For a 10m slope height, a stabilizing pile can be used in the foundation soil with a $20^{\circ}$ internal friction angle and a cohesion of 10kPa and a stabilizing pile can be used in the foundation soil with a $0^{\circ}$ internal friction angle and 40kPa, 45kPa and 50kPa of cohesion. According to the analysis results of stabilizing pile-reinforced foundation soil, the length of the stabilizing pile and magnitude of the maximum bending moment were strongly affected by the internal friction angle of the foundation soil. The lengths of stabilizing pile, for an internal friction angle of $0^{\circ}$ were 4.6, 8.0 times greater than those with an internal friction angle of $5^{\circ}$. The magnitude of the maximum bending moment of the stabilizing pile for an internal friction angle of $0^{\circ}$ was 24.6 times greater than that for an internal friction angle of $5^{\circ}$. Practically, a stabilizing pile cannot be used for foundation soil with an internal friction angle of $0^{\circ}$. Considering the results derived from this study, the effects of a stabilizing pile can be maximized for soft foundation soil that is embanked with a slow construction speed.

The Study On Quality Control of Magnetic Resonance Imaging System (자기공명영상장치의 정도관리에 관한 연구)

  • Jeong, Cheon-Soo;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.178-186
    • /
    • 2009
  • The quality control is needed to ensure the accuracy of medical information and achieved by evaluating the performance of and maintaining the system and practicing various measurements and evaluations. The Korean Institute for Accreditation of Medical Image, therefore, have held educational program for quality control of special medical equipments. The major of programs participants, however, are radiology specialists with only small number of radiological technologists from some hospitals, furthermore, the follow-up education and the share of information between participants and non-participants are insufficient in general, thus, the knowledge level of radiological technologists, regardless of their participation, is relatively low. This study carried out the questionnaire research for the 500 radiological technologists registered in Korean Society of MRI Technology, on the basis of 2008, and performed analysis for five months from May to Oct., 2008. The questionnaires were delivered by post to each radiological technologists and the response rate was 36%(n=180). The results of this revealed that the 86.7% of respondents felt the necessity of inspection on quality management, while only the 27.8% completed the educational program for manager of special medical equipment. and only the half(53.9%) had the knowledge about inspection on quality management. The completion of educational program had no correlations with sex, age, size of occupying hospital, the number of radiological technologists in occupying site and MRI laboratory, career year of general radiologist and in MRI laboratory, and the presence of biomedical engineering department in occupying hospital. The 78.0% of participants at the educational program for quality management held by the Korean Institute for Accreditation of Medical Image had the knowledge about inspection on quality management(p<.05) whereas the 43.9% of the hospitals held such program and the 54.4% of radiological technologists from those hospitals had related knowledge, which indicated that such programs held by hospitals had not effects on the knowledge level of radiological technologists. This indicates also that the contents, methods, and other conditional factors of educational programs are important for the outcome of them.