• 제목/요약/키워드: engineering technique

검색결과 22,315건 처리시간 0.044초

이차원 비정렬 격자계에서의 보존적 중첩 격자 기법 (CONSERVATIVE OVERSET MESH TECHNIQUE ON 2-D UNSTRUCTURED MESHES)

  • 정승문;권오준;강희정
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.27-32
    • /
    • 2008
  • In the present study, a conservative overset mesh technique has been developed on 2-D unstructured meshes. A new domain connection technique between independent mesh blocks was proposed to satisfy the conservation of mass, momentum, or energy in entire computational domain. The present technique was applied to several classical computational problems to validate the superiority of the conservative method to the non-conservative method.

  • PDF

이차원 비정렬 격자계에서의 보존적 중첩 격자 기법 (CONSERVATIVE OVERSET MESH TECHNIQUE ON 2-D UNSTRUCTURED MESHES)

  • 정문승;권오준;강희정
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.27-32
    • /
    • 2008
  • In the present study, a conservative overset mesh technique has been developed on 2-D unstructured meshes. A new domain connection technique between independent mesh blocks was proposed to satisfy the conservation of mass, momentum, or energy in entire computational domain. The present technique was applied to several classical computational problems to validate the superiority of the conservative method to the non-conservative method.

  • PDF

수압 측정에 기반하는 요류검사의 정확도 검증 (Accuracy Validation of Urinary Flowmetry Technique Based on Pressure Measurement)

  • 최성수;이인광;김군진;강승범;박경순;이태수;차은종;김경아
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.198-204
    • /
    • 2008
  • Uroflowmetry is a non-invasive clinical test useful for screening benign prostatic hyperplasia(BPH) common in the aged men. The current standard way to obtain the urinary flow rate is to continuously acquire the urine weight signal proportional to volume over time. The present study proposed an alternative technique measuring pressure to overcome noise problems present in the standard weight measuring technique. Experiments were performed to simultaneously acquire both weight and pressure changes during urination of 9 normal men. Noise components were separated from volume signals converted from both weight and pressure signals based on the polynomial signal model. Signal-to-noise ratio was defined as the ratio of the energies between signal and noise components of the measured volume changes, which was 8.5 times larger in the pressure measuring technique, implying that cleaner signal could be obtained, more immune to noisy environments. When four important diagnostic parameters were estimated, excellent correlation coefficients higher than 0.99 were resulted with mean relative errors less than 5%. Therefore, the present pressure measurement seemed valid as an alternative technique for uroflowmetry.

A review of the application of acoustic emission technique in engineering

  • Gholizadeh, S.;Leman, Z.;Baharudin, B.T.H.T.
    • Structural Engineering and Mechanics
    • /
    • 제54권6호
    • /
    • pp.1075-1095
    • /
    • 2015
  • The use of acoustic emission (AE) technique for detecting and monitoring damages and the progress on damages in different structures is widely used and has earned a reputation as one of the most reliable and well-established technique in non-destructive testing (NDT). Acoustic Emission is a very efficient and effective technology used for fracture behavior and fatigue detection in metals, fiberglass, wood, composites, ceramics, concrete and plastics. It can also be used for detecting faults and pressure leaks in vessels, tanks, pipes, as well as for monitoring the progression of corrosion in welding. This paper reviews major research developments over the past few years in application of acoustic emission in numerous engineering fields, including manufacturing, civil, aerospace and material engineering.

Synthesis of four-bar linkage motion generation using optimization algorithms

  • Phukaokaew, Wisanu;Sleesongsom, Suwin;Panagant, Natee;Bureerat, Sujin
    • Advances in Computational Design
    • /
    • 제4권3호
    • /
    • pp.197-210
    • /
    • 2019
  • Motion generation of a four-bar linkage is a type of mechanism synthesis that has a wide range of applications such as a pick-and-place operation in manufacturing. In this research, the use of meta-heuristics for motion generation of a four-bar linkage is demonstrated. Three problems of motion generation were posed as a constrained optimization probably using the weighted sum technique to handle two types of tracking errors. A simple penalty function technique was used to deal with design constraints while three meta-heuristics including differential evolution (DE), self-adaptive differential evolution (JADE) and teaching learning based optimization (TLBO) were employed to solve the problems. Comparative results and the effect of the constraint handling technique are illustrated and discussed.

Fast Response Technique 2 Quadrant DC Motor Speed Control

  • W. Piyarat;V. Tipsuwanporn;W. Sawangsinkasikit;Lee, M. lajindarairerk;P. Thepsatorn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.244-247
    • /
    • 1999
  • This paper presents a methodology of the technique for controlling DC motor drive by implementation of 2-quadrant operating mode which can ensure the torque controlling and speed with response time less than 2 seconds at all loading conditions. By implementation of BRM technique, energy is fed with definite values of BRM 256 bits, with different patterns of high accuracy, and fixing scan time at 0.667 ms, the ripple is less than 1%, thus high efficiency can be achieved, from the consequence of the accuracy of energy feeding at low current. The stability of the whole system can be determined from circle criterion by root locus method . The instant reverse direction of rotation can be done by decreasing the energy to the lowest level while motor is running with no load and variable load at the speed about 100-120 rpm and 50-60 rpm.

  • PDF

Surface Plasmon Resonance Immunosensor for Detection of Legionella pneumophila

  • Oh, Byung-Keun;Lee, Woochang;Bae, Young-Min;Lee, Won-Hong;Park, Jeong-Woo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권2호
    • /
    • pp.112-116
    • /
    • 2003
  • An immunosensor based on surface plasmon resonance (SPR) onto a protein G layer by Self-assembly technique was developed for detection of Legionella pneumophila. The protein G layer by self-assembly technique was fabricated on a gold (Au) surface by adsorbing the 11-mercaptoundecanoic acid (MUA) and an activation process for the chemical binding of the free amino (-NH$_2$) of protein G and 11-(MUA) using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDAC) in series. The formation of the protein G layer by self-assembly technique on the Au Substrate and the binding of the antibody and antigen in series were confirmed by SPR spectroscopy. The Surface topographies of the fabricated thin films on an Au substrate were also analyzed by using an atomic force microscope (AFM). Consequently, an immunosensor for the detection of L. pneumophila using SPR was developed with a detection limit of up to 10$^2$CFU per mL.

Study on Advanced Frequency Estimation Technique using Gain Compensation

  • Park, Chul-Won;Shin, Dong-Kwang;Kim, Chul-Hwan;Kim, Hak-Man;Kim, Yoon-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.439-446
    • /
    • 2011
  • Frequency is an important operating parameter for the protection, control, and stability of a power system. Thus, it must be maintained very close to its nominal frequency. Due to the sudden change in generation and loads or faults in a power system, however, frequency deviates from its nominal value. An accurate monitoring of the power frequency is essential for optimum operation and prevention of wide area blackout. Most conventional frequency estimation schemes are based on the DFT filter. In these schemes, the gain error could cause defects when the frequency deviates from the nominal value. We present an advanced frequency estimation technique using gain compensation to enhance the DFT filter-based technique. The proposed technique can reduce the gain error caused when the frequency deviates from the nominal value. Simulation studies are performed using both the data from EMTP-RV software and the user-defined arbitrary signals to demonstrate the effectiveness of the proposed algorithm. Results show that the proposed algorithm achieves good performance under both steady state tests and dynamic conditions.

Adaptive p-finite element method for wind engineering

  • Selvam, R. Panneer;Qu, Zu-Qing
    • Wind and Structures
    • /
    • 제5권2_3_4호
    • /
    • pp.301-316
    • /
    • 2002
  • An important goal of computational wind engineering is to impact the design process with simulations of flow around buildings and bridges. One challenging aspect of this goal is to solve the Navier-Stokes (NS) equations accurately. For the unsteady computations, an adaptive finite element technique may reduce the computer time and storage. The preliminary application of a p-version as well as an h-version adaptive technique to computational wind engineering has been reported in previous paper. The details on the implementation of p-adaptive technique will be discussed in this paper. In this technique, two posteriori error estimations, which are based on the velocity and vorticity, are first presented. Then, the polynomial order of the interpolation function is increased continuously element by element until the estimated error is less than the accepted. The second through sixth orders of hierarchical functions are used as the interpolation polynomials. Unequal order interpolations are used for velocity and pressure. Using the flow around a circular cylinder with Reynolds number of 1000 the two error estimators are compared. The result show that the estimated error based on the velocity is lower than that based on the vorticity.

Electro-Micromechanical 시험법을 이용한 Electrospun PVDF Fiber 및 CNT 강화 Epoxy 복합재료의 비파괴 감지능 평가 (Nondestructive Sensing Evaluation of Electrospun PVDF Fiber and Carbon Nanotube/Epoxy Composites Using Electro-Micromechanical Technique)

  • 정진규;김성주;박종만
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.153-156
    • /
    • 2005
  • Nondestructive sensing of electrospun PYDF web and multi-wall carbon nanotube (MWCNT)/epoxy composites were investigated using electro-micromechanical technique. Electrospinning is a technique used to produce micron to submicron diameter polymeric fibers. Electrospun PVDF web was also evaluated for the sensing properties by micromechanical test and by measurement electrical resistance. CNT composite was especially prepared for high volume contents, 50 vol% of reinforcement. Electrical contact resistivity on humidity sensing was a good indicator for monitoring as for multifunctional applications. Work of adhesion using contact angle measurement was studied to correlate acid-base surface energy between carbon fiber and CNF composites, and will study furher for interfacial adhesion force by micromechanical test.

  • PDF